RESUMO
Herein, a new, direct paper-based fluorimetric method is described for the quantitative determination of glutathione (GSH) molecules in nutritional supplements. Briefly, the proposed analytical method is based on the fluorescence emission resulting from the direct and selective chemical reaction of GSH molecules with the derivatization reagent that is o-phthalaldehyde (OPA) in acidic conditions at room temperature. The intensity of the emitted fluorescence on the surface of the analytical paper devices after irradiation with a lamp at 365 nm is proportional to the concentration of GSH and is measured using a smartphone as the detector. This methodology, which is suitable for measurements in laboratories with limited resources, does not require specialized instrumentation or trained personnel. The protocol governing the proposed method is simple and easily applicable. Essentially, the chemical analyst should adjust the value of pH on the surface of the paper by adding a minimal amount of buffer solution; then, after adding a few microliters of the derivatization reagent, wait for the surface of the paper to dry and, finally, add the analyte. Subsequently, the irradiation of the sensor and the measurement of the emitted fluorescence can be recorded with a mobile phone. In the present study, several parameters affecting the chemical reaction and the emitted fluorescence were optimized, the effect of interfering compounds that may be present in dietary supplements was examined, and the stability of these paper sensors under different storage conditions was evaluated. Additionally, the chemical stability of these paper devices in various maintenance conditions was studied, with satisfactory results. The detection limit calculated as 3.3 S/N was 20.5 µmol L-1, while the precision of the method was satisfactory, ranging from 3.1% (intra-day) to 7.3% (inter-day). Finally, the method was successfully applied to three different samples of dietary supplements.
Assuntos
Suplementos Nutricionais , Fluorometria , Glutationa , Papel , o-Ftalaldeído , o-Ftalaldeído/química , Suplementos Nutricionais/análise , Fluorometria/métodos , Glutationa/análise , Glutationa/química , Espectrometria de Fluorescência/métodosRESUMO
A simple, equipment-free, direct fluorometric method, employing paper-based analytical devices (PADs) as sensors, for the selective determination of quinine (QN) is described herein. The suggested analytical method exploits the fluorescence emission of QN without any chemical reaction after the appropriate pH adjustment with nitric acid, at room temperature, on the surface of a paper device with the application of a UV lamp at 365 nm. The devices crafted had a low cost and were manufactured with chromatographic paper and wax barriers, and the analytical protocol followed was extremely easy for the analyst and required no laboratory instrumentation. According to the methodology, the user must place the sample on the detection area of the paper and read with a smartphone the fluorescence emitted by the QN molecules. Many chemical parameters were optimized, and a study of interfering ions present in soft drink samples was carried out. Additionally, the chemical stability of these paper devices was considered in various maintenance conditions with good results. The detection limit calculated as 3.3 S/N was 3.6 mg L-1, and the precision of the method was satisfactory, being from 3.1% (intra-day) to 8.8% (inter-day). Soft drink samples were successfully analyzed and compared with a fluorescence method.
Assuntos
Papel , Quinina , Fluorometria , Bebidas Gaseificadas , Fatores de TempoRESUMO
In this communication, we describe the first analytical method for the determination of free histidine in hair care products (shampoos and conditioners). Cation-exchange chromatography combined with postcolumn derivatization and fluorimetric detection enabled the accurate (recovery: 83.5-114.8%) and precise (2.4-5.6% RSD) determination of free histidine without matrix interferences at concentration levels down to 1.5 mg kg-1. Real commercially available samples were found to contain the amino acid at levels ranging between 70 and 535 mg kg-1.
Assuntos
Preparações para Cabelo , Histidina , Humanos , Cromatografia Líquida de Alta Pressão/métodos , Fluorometria , Indicadores e ReagentesRESUMO
A high-throughput fluorimetric assay for histidine was developed, using a 96-well plates platform. The analyte reacts selectively with o-phthalaldehyde under mild alkaline conditions to form a stable derivative. Instrumental-free detection was carried out using a smartphone after illumination under UV light (365 nm). The method was proved to be linear up to 100 µM histidine, with an LLOQ (lower limit of quantification) of 10 µM. The assay was only prone to interference from glutathione and histamine that exist in the urine samples at levels that are orders of magnitude lower compared to histidine. Human urine samples were analyzed following minimum treatment and were found to contain histidine in the range of 280 to 1540 µM. The results were in good agreement with an HPLC corroborative method.
Assuntos
Ensaios de Triagem em Larga Escala , Histidina , Smartphone , Fluorometria/métodos , Histidina/urina , Humanos , o-Ftalaldeído/químicaRESUMO
Histidine (His) is an essential amino acid that plays an important biological role and associated with various pathological conditions. A simple and reliable method for the determination of endogenous histidine in human saliva was optimized and validated. The analyte was separated from the saliva matrix by cation exchange chromatography and detected fluorimetrically (λex/λem = 360/440 nm) after online, specific post-column derivatization (PCD) reaction with o-phthalaldehyde. The chemical and instrumental variables of the post-column reaction were optimized using Box-Behnken experimental design to achieve maximum sensitivity. Method validation was carried out employing the total-error concept. Histidine could be analyzed reliably in the range of 0.5-5.0 µΜ, with an LOD (S/N = 3) of 50 nM. Monte Carlo simulations and capability analysis were used to investigate the ruggedness of the PCD reaction. The sampling strategy, sample preparation and stability were also investigated. Seventeen saliva samples were successfully analyzed with histidine levels being in the range of 2.7-19.5 µΜ.
Assuntos
Histidina , Saliva , Cromatografia Líquida de Alta Pressão/métodos , Histidina/análise , Humanos , Projetos de Pesquisa , o-Ftalaldeído/químicaRESUMO
A fast and green ultra-high-performance liquid chromatographic method was developed for the determination of ibuprofen in milk-containing simulated gastrointestinal media to monitor the dissolution of three-dimensional printed formulations. To remove interfering compounds, protein precipitation using methanol as a precipitation reagent was performed. The separation of the target analyte was performed on a C18 column using a mobile phase consisting of 0.05% v/v aqueous phosphoric acid solution: methanol, 25:75% v/v. Method validation was conducted using the total error concept. The ß-expectation tolerance intervals did not exceed the acceptance criteria of ±15%, meaning that 95% of future results will be included in the defined bias limits. The relative bias ranged between â1.1 and +3.2% for all analytes, while the relative standard deviation values for repeatability and intermediate precision were less than 2.8% and 3.9%, respectively. The achieved limit of detection was 0.01 µg/ml and the lower limit of quantitation was established as 2 µg/ml. The proposed method was simple, and it required reduced organic solvent consumption following the requirements of Green Analytical Chemistry. The method was successfully employed for the determination of ibuprofen in real biorelevant media obtained from dissolution studies.
Assuntos
Ibuprofeno , Leite , Animais , Leite/química , Ibuprofeno/análise , Solubilidade , Metanol , Limite de Detecção , Cromatografia Líquida , Cromatografia Líquida de Alta Pressão/métodosRESUMO
A salting-out homogeneous liquid-liquid microextraction was proposed for the quantification of four azole drugs in human urine prior to high-performance liquid chromatography analysis. The procedure involved the mixing of the sample with acetonitrile in appropriate volumes followed by the addition of sodium sulfate solution in order to facilitate phase separation. The parameters influencing the extraction performance were studied and optimized using a two-step experimental design. The analytical procedure was thoroughly validated using the accuracy profiles as a graphical decision-making tool. The ß-expectation tolerance intervals did not exceed the acceptance criteria of ±15% meaning that 95% of future results will be included in the defined bias limits. The limits of detection of the procedure were satisfactory, ranging between 0.01 and 0.03 µg/mL. The mean analytical bias in the spiking levels was satisfactory and ranged between -10.3 and 4.2% while the relative standard deviation was lower than 5.6%. Monte-Carlo simulations followed by capability analysis were employed to investigate the ruggedness of the sample preparation protocol. The developed method offers advantages compared to previously reported approaches for the same type of analysis including extraction efficiency and scaling down of the sample volume and extraction time.
Assuntos
Microextração em Fase Líquida , Azóis , Cromatografia Líquida de Alta Pressão/métodos , Humanos , Limite de Detecção , Microextração em Fase Líquida/métodos , Extração Líquido-Líquido , Cloreto de Sódio/químicaRESUMO
A novel, rapid, and facile method for the colorimetric determination of calcium using micro-analytical paper-based devices (µ-PADs) was developed. The proposed analytical method utilizes the color differences developing, after the addition of calcium, on the surface of the devices because of the complexation reaction of calcium with Methylthymol Blue (MTB) at room temperature, in alkaline pH. The devices were manufactured with chromatographic paper, using wax barriers, and the analytical protocol was easily implemented without the need of any experimental apparatus except for a simple imaging device. The user must regulate the pH, add the solutions on the paper, and measure the color intensity of the formed Ca(II)-MTB complex with a flatbed scanner. The experimental conditions for optimum color development, the possible interfering substances, and the reliability of the paper devices in different preserving conditions were optimized, with satisfactory results. The method exhibited acceptable detection limits (2.9 mg L-1) with sufficiently good precision, which varied from 4.2% (intra-day) to 6.4% (inter-day). Saliva samples from healthy volunteers were successfully analyzed, and the calcium levels were calculated in the range of 30.71 to 84.15 mg L-1.
Assuntos
Cálcio , Colorimetria , Humanos , Cálcio/análise , Saliva/química , Reprodutibilidade dos Testes , PapelRESUMO
Herein, we report a new automated flow method based on zone fluidics for the simultaneous determination of homocysteine and homocysteine thiolactone using fluorimetric detection (λext = 370 nm/λem = 480 nm). Homocysteine thiolactone is hydrolyzed on-line in alkaline medium (1 mol L−1 NaOH) to yield homocysteine, followed by reaction with o-phthalaldehyde in a single step. Derivatization is rapid without the need of elevated temperatures and stopped-flow steps, while specificity is achieved through a unique reaction mechanism in the absence of nucleophilic compounds. Mixtures of the analytes can be analyzed quantitatively after specific separation with fluorosurfactant-capped gold nanoparticles that are selectively aggregated by homocysteine, leaving the thiolactone analogue in solution. As low as 100 nmol L−1 of the analyte(s) can be quantified in aqueous solutions, while concentrations > 2 µmol L−1 can be analyzed in artificial and real urine matrix following 20-fold dilution. The percent recoveries ranged between 87 and 119%.
Assuntos
Ouro , Nanopartículas Metálicas , Homocisteína/análogos & derivados , HidróliseRESUMO
In this study, the development, validation, and application of a new liquid chromatography post-column derivatization method for the determination of Colistin in human urine samples is demonstrated. Separation of Colistin was performed using a core-shell C18 analytical column in an alkaline medium in order (i) to be compatible with the o-phthalaldehyde-based post-column derivatization reaction and (ii) to obtain better retention of the analyte. The Colistin derivative was detected spectrofluorometrically (λext/λem = 340/460 nm) after post-column derivatization with o-phthalaldehyde and N-acetyl cysteine. The post-column derivatization parameters were optimized using the Box-Behnken experimental design, and the method was validated using the total error concept. The ß-expectation tolerance intervals did not exceed the acceptance criteria of ±15%, meaning that 95% of future results would be included in the defined bias limits. The limit of detection of the method was adequate corresponding to 100 nmol·L-1. The mean analytical bias (expressed as relative error) in the spiking levels was suitable, being in the range of -2.8 to +2.5% for both compounds with the percentage relative standard deviation lower than 3.4% in all cases. The proposed analytical method was satisfactorily applied to the analysis of the drug in human urine samples.
Assuntos
Colistina , Acetilcisteína , Cromatografia Líquida de Alta Pressão/métodos , Colistina/urina , Humanos , o-FtalaldeídoRESUMO
In the present research, a zone fluidics-based automated sensor for the analysis of captopril in in vitro dissolution samples is reported. Captopril is reacted under flow conditions with Ni(II) (10 mmol L-1) in alkaline medium (0.15% v/v NH3) to form a stable derivate, which is monitored spectrophotometrically at 340 nm. The chemical and instrumental parameters were carefully investigated and optimized. The validation of the developed method was performed in the range of 5 to 120% of the expected maximum concentration using the accuracy profiles as a graphical decision-making tool. The ß-expectation tolerance intervals did not exceed the acceptance criteria of ±10%, which means that 95% of future results will be encompassed in the defined bias limits. The variation of the relative bias ranged between -2.3% and 3.5% and the RSD values for repeatability and intermediate precision were lower than 2.3% in all cases. The limit of detection (LOD), and the lower and the upper limit of quantification (LLOQ, ULOQ) were satisfactory and found to be 1%, 5% and 120% (corresponding to 0.6, 2.78 and 66.67 µg mL-1 in dissolution medium). The developed method was successfully applied for the analysis of captopril in dissolution tests of two commercially available batches.
Assuntos
Captopril/química , Técnicas de Química Analítica/instrumentação , Automação , SolubilidadeRESUMO
The first dispersive liquid liquid microextraction scheme followed by liquid chromatography-post column derivatization for the determination of the antiviral drug rimantadine in urine samples is demonstrated. The effect of the type and volume of organic extraction solvent, type and volume of disperser solvent, sample pH, ionic strength, extraction time, and centrifugation speed on the extraction efficiency were studied. Rimantadine and the internal standard (amantadine) were chromatographed using a reversed phase monolithic stationary phase with a mixture of equal volumes of methanol and phosphate buffer (pH = 3) as mobile phase. On-line post-column derivatization of the analyte was performed using a "two-stream" manifold with o-phthalaldehyde and N-acetyl-cysteine at alkaline medium. Under the optimized extraction conditions, the enrichment factor of rimantadine was 58. The linear range was 5-100 µg/L with correlation coefficient r of 0.9984 while the limit of detection achieved was 0.5 µg/L. The within-day and between-day precision for the tested concentration levels were less than 14.3% and the mean recoveries obtained from the spiked samples were ranged between 87.5 and 113.9%. The main advantages of the proposed method are the simplicity of operation, rapidity, low cost, and low limit of detection of the analyte.
Assuntos
Microextração em Fase Líquida , Rimantadina/urina , Cromatografia Líquida de Alta Pressão/instrumentação , Voluntários Saudáveis , Humanos , Microextração em Fase Líquida/instrumentaçãoRESUMO
In the present study we report the reaction between homocysteine and o-phthalaldehyde under flow conditions. Homocysteine reacts on-line with the derivatization reagent in a strong alkaline medium and in the absence of nucleophilic reagents to yield a fluorescent derivative (λex /λem = 370/480 nm). The reaction variables were investigated using the concept of zone fluidics. Selectivity factors against other compounds were calculated at 10-fold excess. The findings formed the basis of an automated proposed method that was found to be linear in the range 0.1-1.5 µmol L-1 , with a limit of detection of 20 nmol L-1 and relative standard deviation < 0.5% (within-day) and 3.2% (between-day). The method proved to be rapid, offering a practical sampling rate of 24 h-1 and accurate following application to an artificial urine matrix with minimum dilution.
Assuntos
Homocisteína , o-Ftalaldeído , Cromatografia Líquida de Alta Pressão , Fluorometria , Indicadores e ReagentesRESUMO
Undoubtedly, sample preparation is one of the most important steps in the analytical process [...].
Assuntos
Microextração em Fase Sólida/métodos , Animais , Extratos Vegetais/isolamento & purificação , Plantas/química , Reprodutibilidade dos Testes , Manejo de EspécimesRESUMO
In-tube solid phase microextraction is a cutting-edge sample treatment technique offering significant advantages in terms of miniaturization, green character, automation, and preconcentration prior to analysis. During the past years, there has been a considerable increase in the reported publications, as well as in the research groups focusing their activities on this technique. In the present review article, HPLC bioanalytical applications of in-tube SPME are discussed, covering a wide time frame of twenty years of research reports. Instrumental aspects towards the coupling of in-tube SPME and HPLC are also discussed, and detailed information on materials/coatings and applications in biological samples are provided.
Assuntos
Cromatografia Líquida de Alta Pressão , Microextração em Fase Sólida , Cromatografia Líquida de Alta Pressão/instrumentação , Cromatografia Líquida de Alta Pressão/métodos , Cromatografia Líquida de Alta Pressão/tendências , Humanos , Espectrometria de Massas , Farmacologia Clínica/instrumentação , Farmacologia Clínica/métodos , Microextração em Fase Sólida/instrumentação , Microextração em Fase Sólida/métodos , Microextração em Fase Sólida/normas , Microextração em Fase Sólida/tendênciasRESUMO
In the present study, the determination of histidine (HIS) by an on-line flow method based on the concept of zone fluidics is reported. HIS reacts fast with o-phthalaldehyde at a mildly basic medium (pH 7.5) and in the absence of additional nucleophilic compounds to yield a highly fluorescent derivative (λex/λem = 360/440 nm). The flow procedure was optimized and validated, paying special attention to its selectivity and sensitivity. The LOD was 31 nmol·L-1, while the within-day and day-to-day precisions were better than 1.0% and 5.0%, respectively (n = 6). Random urine samples from adult volunteers (n = 7) were successfully analyzed without matrix effect (<1%). Endogenous HIS content ranged between 116 and 1527 µmol·L-1 with percentage recoveries in the range of 87.6%-95.4%.
Assuntos
Histidina/urina , Urina/química , Adulto , Cromatografia Líquida de Alta Pressão , Feminino , Fluorometria , Humanos , Limite de Detecção , Masculino , Voluntários , o-Ftalaldeído/químicaRESUMO
An automated flow method for the determination of hydrazine based on the concept of zone-fluidics has been developed. The analyte reacts under flow conditions with p-dimethylamino benzaldehyde (25 mmol L-1) in micellar medium (100 mmol L-1 SDS) to form a stable derivative (460 nm). Micelles mediated catalysis excludes the use of highly acidic environment typical for this kind of reaction. Following careful examination of chemical and instrumental variables, the method allows the determination of hydrazine at the low micromolar level (0.3-10 µmol L-1) in water samples. Real sample analyses (drinking and boiler feed water) resulted in satisfactory results in terms of accuracy with the percent recoveries being in the range of 82-114%.
Assuntos
Hidrazinas/análise , Poluentes Químicos da Água/análise , Benzaldeídos/química , Catálise , Confiabilidade dos Dados , Limite de Detecção , Micelas , Dodecilsulfato de Sódio/química , Temperatura , Fatores de Tempo , Água/químicaRESUMO
A zone-fluidics (ZF) based automated fluorimetric sensor for the determination of pharmaceutically active adamantine derivatives, i.e., amantadine (AMA), memantine (MEM) and rimantadine (RIM) is reported. Discrete zones of the analytes and reagents (o-phthalaldehyde and N-acetylcysteine) mix and react under stopped-flow conditions to yield fluorescent iso-indole derivatives (λex/ λem = 340/455 nm). The proposed ZF sensor was developed and validated to prove suitable for quality control tests (assay and content uniformity) of commercially available formulations purchased from the Greek market (EU licensed) and from non-EU web-pharmacies at a sampling rate of 16 h-1. Interestingly, a formulation obtained through the internet and produced in a third-non-EU-country (AMA capsules, 100 mg per cap), was found to be out of specifications (mean assay of 85.3%); a validated HPLC method was also applied for confirmatory purposes.
Assuntos
Amantadina/isolamento & purificação , Fluorometria/métodos , Memantina/isolamento & purificação , Rimantadina/isolamento & purificação , Amantadina/química , Cromatografia Líquida de Alta Pressão , Indicadores e Reagentes/química , Indóis/química , Memantina/química , Microfluídica , Rimantadina/químicaRESUMO
High performance liquid chromatography coupled with post-column derivatization is used for increasing the sensitivity and selectivity of the desirable analytes after the chromatographic separation. The transformation of the analytes can be conducted through the addition of a suitable reagent in the eluted stream or the ultraviolet irradiation of the eluted analytes, forming detectable derivatives for ultraviolet or fluorescence detectors. This review focuses on the developed methods using high performance liquid chromatography coupled with post-column derivatization for the determination of substances in food samples during the last two decades. The significance of the determination of each analyte in foods and the existing guidelines in each case are discussed. Preparation of the samples and the analytical methods are commented. For each analyte, official methods and commercially available systems and reagents are mentioned, as well.
Assuntos
Cromatografia Líquida de Alta Pressão , Análise de Alimentos , Cromatografia Líquida de Alta Pressão/métodos , Análise de Alimentos/métodosRESUMO
Clomipramine (CLP) is a tricyclic antidepressant drug, and its determination in biological samples is of high importance in clinical and forensic evaluations to assure appropriate drug concentrations. In the present study, benzoic acid was employed as a pH-switchable hydrophilicity solvent (SHS) for the microextraction of CLP from authentic human urine samples prior to its determination by high performance liquid chromatography-ultraviolet detection (HPLC-UV). The microextraction protocol was based on the phase transition of the SHS through pH alteration that resulted in its rapid dispersion and simultaneous phase separation. The obtained solid was collected in a syringe filter, dissolved in methanol, and analyzed. The main parameters that affected the efficiency of the microextraction procedure were studied and optimized to ensure high extraction efficiency for CLP and the analytical method was validated. Under optimum conditions, good linearity was observed between 0.05 and 5.0 µg mL-1. The limit of detection and limit of quantification were found to be 0.015 and 0.05 µg mL-1, respectively. The RSD values for intra-day repeatability and inter-day precision were 2.4-8.9 % and 1.7-9.1 %, respectively. The relative recovery values were within 90.0 and 110.0 % in all cases, demonstrating good method accuracy. The proposed SHS microextraction showed cost-efficiency, handling simplicity, and rapidity resulting in enhanced sample throughput. Moreover, the proposed method exhibited a green character and good applicability based on its evaluation by Green Analytical Procedure Index and Blue Applicability Grade Index.