Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Circ J ; 76(6): 1409-14, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22447013

RESUMO

BACKGROUND: Left ventricular (LV) hypertrophy is a powerful independent predictor of morbidity and mortality in hypertensive patients. Abnormal LV geometric patterns are also associated with hypertensive complications, and concentric hypertrophy is associated with the highest mortality in hypertensive patients. However, the relationship between geometric patterns and cardiac dysfunction is not fully established. We hypothesized that the Tei index, which is a measure of global cardiac function, is a feasible parameter for estimating cardiac dysfunction among the different LV geometric patterns in hypertensive patients. METHODS AND RESULTS: We enrolled 60 consecutive patients with untreated essential hypertension. Subjects were divided into 4 groups: normal geometry, concentric remodeling, eccentric hypertrophy and concentric hypertrophy. We measured ejection fraction, mitral E/A ratio, Tei index, ejection time, and isovolumic contraction and relaxation times. There were significant correlations between LV mass index and systolic blood pressure (P<0.01), ejection fraction (P<0.05), mitral E/A ratio (P<0.05) and Tei index (P<0.0001). In multiple regression analysis, only the Tei index independently correlated with LV mass index (P<0.01). Concentric hypertrophy significantly increased the Tei index compared with the other 3 groups. CONCLUSIONS: The Tei index provides a better marker for LV dysfunction by hypertensive hypertrophy than conventional parameters. LV function in concentric hypertrophy was most impaired among all the geometric patterns in untreated hypertensive patients.


Assuntos
Ecocardiografia Doppler , Hipertensão/complicações , Hipertrofia Ventricular Esquerda/diagnóstico por imagem , Contração Miocárdica , Volume Sistólico , Disfunção Ventricular Esquerda/diagnóstico por imagem , Função Ventricular Esquerda , Análise de Variância , Pressão Sanguínea , Eletrocardiografia , Feminino , Humanos , Hipertensão/fisiopatologia , Hipertrofia Ventricular Esquerda/etiologia , Hipertrofia Ventricular Esquerda/fisiopatologia , Japão , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Modelos Cardiovasculares , Valor Preditivo dos Testes , Fatores de Tempo , Disfunção Ventricular Esquerda/etiologia , Disfunção Ventricular Esquerda/fisiopatologia , Remodelação Ventricular
2.
J Echocardiogr ; 11(3): 97-9, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27278613

RESUMO

A 39-year-old male who had undergone tricuspid valve replacement for severe tricuspid regurgitation was admitted with palpitation and general edema. Two-dimensional (2D) echocardiography showed tricuspid prosthetic valve dysfunction. Additional three-dimensional (3D) transthoracic and transesophageal echocardiography (TEE) could clearly demonstrate the disabilities of the mechanical tricuspid valve. Particularly, 3D TEE demonstrated a mass located on the right ventricular side of the tricuspid prosthesis, which may have caused the stuck disk. This observation was confirmed by intra-operative findings.

3.
Int J Cardiol ; 168(2): 1280-5, 2013 Sep 30.
Artigo em Inglês | MEDLINE | ID: mdl-23269316

RESUMO

BACKGROUND: Recent evidence suggests that atrial fibrillation (AF) adversely affects endothelial function. The goal of this study was to assess endothelial function in patients with AF before and after restoration of sinus rhythm by catheter ablation (ABL). METHODS: Reactive hyperemia peripheral arterial tonometry (RH-PAT) measurements reflecting endothelial function were conducted with Endo-PAT2000 (Itamar Medical, Caesarea, Israel) in 27 patients with persistent AF before ABL and in 21 control subjects with sinus rhythm (SR). According to cardiac rhythm on the morning after ABL, patients were divided into two groups: day 1-restored SR group (n=19) and day 1-recurred AF group (n=8). Based on the cardiac rhythm at 6 months after ABL, the restored SR group was further subdivided into the month 6-maintained SR group (n=11) and the month 6-recurred AF group (n=6). RESULTS: Loge RH-PAT index (RHI) was significantly lower in the persistent AF group than in the control (SR) group (0.52 ± 0.20; 0.69 ± 0.24, p<0.01). Multivariate logistic regression analysis revealed that persistent AF was the only independent predictor of impaired endothelial function defined as loge RHI<0.6 (odds ratio, 4.96; 95% CI, 1.2 to 21.3; p<0.05). Loge RHI was significantly higher after ABL than before ABL (0.53±0.20; 0.73 ± 0.25; p<0.01) in the day 1-restored SR group. Loge RHI of the month 6-maintained SR group was comparable to that of the day 1-restored SR group. CONCLUSIONS: These results suggest that AF is associated with impairment of endothelial dysfunction and that this impairment is reversed by restoration of sinus rhythm.


Assuntos
Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/fisiopatologia , Endotélio Vascular/fisiopatologia , Frequência Cardíaca/fisiologia , Adulto , Idoso , Fibrilação Atrial/sangue , Estudos Transversais , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento , Ultrassonografia
4.
J Am Soc Echocardiogr ; 24(7): 768-74, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21555206

RESUMO

OBJECTIVE: An increase in the diastolic to systolic flow velocity ratio (D/S) in the proximal left internal thoracic artery (ITA) after coronary artery bypass grafting (CABG) enables noninvasive assessment of graft patency by transthoracic Doppler echocardiography (TTDE). The increase in the D/S can be less pronounced at a site distant from the anastomosis. We postulated that proximal ITA flow patterns differ between the left and right ITAs and that the increase in D/S is less pronounced in the right than in the left proximal ITA. METHODS: Proximal ITA flow was examined by TTDE in 129 consecutive patients after CABG of the left (75) or right (69) ITA to the left coronary artery. The mean D/S of the ITAs was compared with coronary angiography. RESULTS: The D/S was lower in the group with a patent right ITA than in the group with a patent left ITA (P < .05). The D/S of both the left and right ITAs negatively correlated with angiographic stenosis (r = 0.56 or 0.67, P < .001, respectively). The regression line was significantly shifted downward in the right ITA compared with the left ITA, according to analysis of covariance (P = .01). Graft stenosis was predicted by a D/S of <0.57 and <0.28 with an accuracy of 91% and 97% in the left and right ITAs, respectively. CONCLUSION: The patency of both left and right ITA grafts to the left coronary artery can be assessed using TTDE, but different cutoff values of D/S are required to diagnose severe ITA stenosis.


Assuntos
Estenose Coronária/cirurgia , Ecocardiografia Doppler/métodos , Oclusão de Enxerto Vascular/cirurgia , Anastomose de Artéria Torácica Interna-Coronária , Artéria Torácica Interna/diagnóstico por imagem , Grau de Desobstrução Vascular/fisiologia , Idoso , Velocidade do Fluxo Sanguíneo , Angiografia Coronária , Estenose Coronária/diagnóstico por imagem , Feminino , Seguimentos , Oclusão de Enxerto Vascular/diagnóstico por imagem , Humanos , Masculino , Artéria Torácica Interna/fisiopatologia , Artéria Torácica Interna/transplante
5.
Hypertens Res ; 33(11): 1167-73, 2010 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-20720552

RESUMO

Regional left ventricular (LV) systolic dysfunction has been identified in diastolic heart failure (DHF). However, the relationship between regional or global LV systolic function and heart failure symptoms in DHF has not been evaluated in detail. The present study evaluates such relationships in patients with systemic hypertension (HT) and DHF. We assessed LV systolic and diastolic function in 220 consecutive patients with systemic HT and in 30 normal individuals (Control) using Doppler echocardiography. Patients with HT were assigned to groups with DHF, asymptomatic diastolic dysfunction (ADD) and no diastolic dysfunction (Simple HT). Ejection fraction in DHF was significantly decreased (63±8%) compared with the Control, Simple HT and ADD groups (67±5, 66±7 and 68±8%, respectively). Isovolumetric contraction time in DHF (70±30 msec) was significantly increased compared with those in the ADD, Simple HT and Control groups (31±17, 31±15 and 30±19 msec, respectively). Mitral annular systolic velocities were significantly decreased in the DHF and ADD groups (6.4±1.5 and 7.2±1.3 cm sec⁻¹, respectively) compared with those in the Simple HT and Control groups (8.5±1.8 and 8.4±3.0 cm sec⁻¹, respectively), and in the DHF group compared with the ADD group. LV global systolic dysfunction has a significant role in the development of heart failure symptoms associated with DHF in patients with systemic HT.


Assuntos
Insuficiência Cardíaca Diastólica/etiologia , Hipertensão/complicações , Disfunção Ventricular Esquerda/complicações , Idoso , Ecocardiografia Doppler , Feminino , Insuficiência Cardíaca Diastólica/diagnóstico por imagem , Humanos , Hipertensão/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Contração Miocárdica , Volume Sistólico , Disfunção Ventricular Esquerda/diagnóstico por imagem
6.
J Cardiol ; 53(3): 437-46, 2009 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-19477388

RESUMO

OBJECTIVES: The purpose of this study was to re-assess the left ventricular (LV) systolic function in diastolic heart failure (DHF) using Doppler echocardiography. BACKGROUND: Systolic function in DHF is defined as the preserved LV ejection fraction (EF). EF may not fully reflect the systolic function in DHF, especially in the presence of abnormalities during the isovolumetric contraction time (ICT). METHODS: We examined LV systolic and diastolic function in 80 consecutive patients with DHF, 30 patients with asymptomatic diastolic dysfunction (ADD), and 30 normal subjects (Control). The LV and left atrial volumes, LV EF, LV ICT, and isovolumetric relaxation time (IRT), early diastolic mitral flow velocity, systolic mitral annular velocity (S'), and early diastolic mitral annular velocity were obtained. RESULTS: LV ICT in DHF (69+/-30 ms) was significantly increased compared to those with ADD (37+/-23 ms) and Control (35+/-26 ms) (P<0.0001). ICT in ADD was equal to that in Control. The LV end-diastolic volume index in DHF (49+/-14 ml/m(2)) was significantly increased compared to those with ADD (42+/-12 ml/m(2)) and Control (43+/-8 ml/m(2)) (P<0.05). S' in DHF (5.9+/-1.4 cm/s) and ADD (6.7+/-1.1 cm/s) was significantly decreased compared to that in Control (8.7+/-2.5 cm/s). CONCLUSIONS: Our results revealed that the major differences between ADD and DHF were global and longitudinal LV systolic dysfunction and LV enlargement. This study suggests that LV systolic dysfunction plays an important role in the development of DHF.


Assuntos
Ecocardiografia Doppler , Insuficiência Cardíaca Diastólica/diagnóstico por imagem , Insuficiência Cardíaca Diastólica/fisiopatologia , Volume Sistólico , Função Ventricular Esquerda , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Sístole , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa