Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
J Biomech Eng ; 145(1)2023 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-35993786

RESUMO

Head injuries account for 15%-20% of all military injuries and pose a high risk of causing functional disability and fatality. Blunt ballistic impacts are one of the threats that can lead to severe head injuries. This review aims to examine the mechanisms and injury risk assessment associated with blunt ballistic head injury (BBHI). The review further discusses research methods and instrumentation used in BBHI studies, focusing on their limitations and challenges. Studies on the mechanisms of focal and diffuse brain injuries remain largely inconclusive and require further effort. Some studies have attempted to associate BBHIs with head mechanics, but more research is required to establish correlations between head mechanics and injury severity. Limited access to experimental models and a lack of instrumentation capable of measuring the mechanics of brain tissue in situ are potential reasons for the lack of understanding of injury mechanisms, injury correlations, and injury tolerance levels specific to this loading regime. Targeted research for understanding and assessing head injuries in blunt ballistic impacts is a necessary step in improving our ability to design protection systems to mitigate these injuries.


Assuntos
Traumatismos Craniocerebrais , Traumatismos Craniocerebrais/prevenção & controle , Desenho de Equipamento , Humanos , Medição de Risco
2.
Ann Biomed Eng ; 51(8): 1816-1833, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37095278

RESUMO

Headforms are widely used in head injury research and headgear assessment. Common headforms are limited to replicating global head kinematics, although intracranial responses are crucial to understanding brain injuries. This study aimed to evaluate the biofidelity of intracranial pressure (ICP) and the repeatability of head kinematics and ICP of an advanced headform subjected to frontal impacts. Pendulum impacts were performed on the headform using various impact velocities (1-5 m/s) and impactor surfaces (vinyl nitrile 600 foam, PCM746 urethane, and steel) to simulate a previous cadaveric experiment. Head linear accelerations and angular rates in three axes, cerebrospinal fluid ICP (CSFP), and intraparenchymal ICP (IPP) at the front, side, and back of the head were measured. The head kinematics, CSFP, and IPP demonstrated acceptable repeatability with coefficients of variation generally being less than 10%. The BIPED front CSFP peaks and back negative peaks were within the range of the scaled cadaver data (between the minimum and maximum values reported by Nahum et al.), while side CSFPs were 30.9-92.1% greater than the cadaver data. CORrelation and Analysis (CORA) ratings evaluating the closeness of two time histories demonstrated good biofidelity of the front CSFP (0.68-0.72), while the ratings for the side (0.44-0.70) and back CSFP (0.27-0.66) showed a large variation. The BIPED CSFP at each side was linearly related to head linear accelerations with coefficients of determination greater than 0.96. The slopes for the BIPED front and back CSFP-acceleration linear trendlines were not significantly different from cadaver data, whereas the slope for the side CSFP was significantly greater than cadaver data. This study informs future applications and improvements of a novel head surrogate.


Assuntos
Traumatismos Craniocerebrais , Pressão Intracraniana , Humanos , Cabeça/fisiologia , Fenômenos Biomecânicos , Aceleração , Cadáver , Encéfalo
3.
J Mech Behav Biomed Mater ; 142: 105859, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37071964

RESUMO

Advanced physical head models capable of replicating both global kinematics and intracranial mechanics of the human head are required for head injury research and safety gear assessment. These head surrogates require a complex design to accommodate realistic anatomical details. The scalp is a crucial head component, but its influence on the biomechanical response of such head surrogates remains unclear. This study aimed to evaluate the influence of surrogate scalp material and thickness on head accelerations and intraparenchymal pressures using an advanced physical head-brain model. Scalp pads made from four materials (Vytaflex20, Vytaflex40, Vytaflex50, PMC746) and each material with four thicknesses (2, 4, 6, and 8 mm) were evaluated. The head model attached to the scalp pad was dropped onto a rigid plate from two heights (5 and 19.5 cm) and at three head locations (front, right side, and back). While the selected materials' modulus exhibited a relatively minor effect on head accelerations and coup pressures, the effect of scalp thickness was shown to be major. Moreover, by decreasing the thickness of the head's original scalp by 2 mm and changing the original scalp material from Vytaflex 20 to Vytaflex 40 or Vytaflex 50, the head acceleration biofidelity ratings could improve by 30% and approached the considered rating (0.7) of good biofidelity. This study provides a potential direction for improving the biofidelity of a novel head model that might be a useful tool in head injury research and safety gear tests. This study also has implications for selecting appropriate surrogate scalps in the future design of physical and numerical head models.


Assuntos
Traumatismos Craniocerebrais , Couro Cabeludo , Humanos , Cabeça , Fenômenos Biomecânicos , Aceleração , Encéfalo
4.
Ann Biomed Eng ; 51(12): 2883-2896, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37773311

RESUMO

A surrogate model of the human calvarium can be used to assess skull-fracture-related head injuries without continuously requiring post-mortem human skulls. Skull simulants developed in the literature often require sophisticated manufacturing procedures and/or materials not always practical when factoring in time or expense considerations. This study's objective was to fabricate three exploratory surrogate models (1. pure epoxy prototype, 2. epoxy-chalk mix prototype, and 3. epoxy-chalk three-layered prototype) of the calvarium to mimic the calvarium's mechanical response at fracture using readily available and cost-effective materials, specifically epoxy and chalk. The surrogates and calvaria were subject to quasi-static and dynamic impact 4-point bending and their mechanical responses were compared statistically. Under quasi-static loading, all three surrogates showed a considerable number of differences in mechanical response variables to calvaria that was deemed significant (p < 0.05). Under dynamic impact loading, there was no sufficient evidence to reject that the average mechanical response variables were equal between the epoxy-chalk three-layered prototype and calvaria (p > 0.05). This included force and bending moment at fracture, tensile strain at fracture, tensile and compressive stress at fracture, tensile modulus, and tensile strain rate. Overall, our study illustrates two main remarks: (1) the three exploratory surrogate models are potential candidates for mimicking the mechanical response of the calvarium at fracture during impact loading and (2) employing epoxy and chalk, which are readily available and cost-effective has the potential to mimic the mechanical response of calvaria in impact loading.


Assuntos
Fraturas Ósseas , Humanos , Teste de Materiais , Estresse Mecânico , Crânio , Carbonato de Cálcio
5.
Ann Biomed Eng ; 49(4): 1199-1208, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33094418

RESUMO

Changes in stress transferred across articular joints have been described as a substantial factor in the initiation and progression of joint disease such as post-traumatic osteoarthritis and have thus been of interest to biomechanical researchers. However, to date, stress magnitudes within the menisci have not been successfully measured. In this study, a novel method for measuring stress within the menisci is presented. Small Fibre Bragg Grating (FBG) sensors were inserted inside menisci and used to measure mechanical stress during replicated gait cycles. In-vitro stress measurements within the menisci were preformed for healthy gait and gait following surgical damage to the joints. Together with our capability to reproduce in vivo motions accurately, the improvements in fibre optic technology have allowed for the first direct measurement of mechanical stress in menisci.


Assuntos
Tecnologia de Fibra Óptica , Marcha/fisiologia , Menisco/fisiologia , Animais , Fenômenos Biomecânicos , Feminino , Ovinos
6.
Ann Biomed Eng ; 49(5): 1288-1297, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33094417

RESUMO

Understanding stresses within the knee joint is central to understanding knee function, and the etiology and progression of degenerative joint diseases such as post-traumatic osteoarthritis. In this study, in vivo gait kinematics of four ovine subjects were recorded using a highly accurate Instrumented Spatial Linkage (ISL) as each subject walked on a standard treadmill. The subjects were then sacrificed, and the right hind limbs removed. Ten purpose-built Fibre Bragg Grating (FBG) sensors were positioned within each stifle joint and used to measured contact stresses on the articulating surface of the tibial plateau as the recorded gait was replicated using a 6-degrees-of-freedom parallel robotic system. This study provides the first accurate, direct measurement of stress in a joint during in vivo gait replication. It was hypothesized that the results would indicate a direct link between gait kinematics and measured stress values. Contrary to this expectation no direct link was found between individualistic differences in kinematics and differences in stress magnitudes. This finding highlights the complex multifactorial nature of stress magnitudes and distribution patterns across articular joints. The results also indicate that stress magnitudes within the knee joint are highly position dependent with magnitudes varying substantially between points only a few mm apart.


Assuntos
Cartilagem Articular/fisiologia , Marcha/fisiologia , Joelho de Quadrúpedes/fisiologia , Tíbia/fisiologia , Animais , Fenômenos Biomecânicos , Feminino , Ovinos , Estresse Mecânico
7.
Ann Biomed Eng ; 48(2): 695-708, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31677123

RESUMO

The relative velocity of the tibiofemoral surfaces during gait before and after partial-ACL and full MCL transection (p-ACL/MCL Tx) was examined in an ovine model (N = 5) and the relation between the variation in the relative sliding velocity component and gross morphological damage was investigated. We defined the in vivo kinematics of the tibiofemoral joints by using an instrumented spatial linkage and then determining the relative velocity components on the reconstructed femoral condyle surfaces. One major finding was that the magnitude of the relative velocity components was relatively high during the initial stance period of the gait and oscillated with a decaying envelope. Interestingly, for most subjects, the highest value of relative sliding velocity occurred during the stance phase, and not swing. The magnitude of the relative velocity components was increased in 3/5 subjects during stance after an injury. For the lateral compartment, there was a significant correlation (p value = 0.005) between the joint gross morphological damage and the increase in the maximum relative sliding velocity during stance. For the medial compartment, there was a trend (p value < 0.1) between the joint gross morphological score and the increase in the maximum relative sliding velocity during stance, 20 weeks after injury. In conclusion, a connection between an increase in the relative surface velocity and gross morphological damage might be due to an increase in the normal stress and the plowing friction between the surfaces.


Assuntos
Traumatismos do Joelho , Articulação do Joelho , Modelos Biológicos , Osteoartrite do Joelho , Animais , Fenômenos Biomecânicos , Feminino , Humanos , Traumatismos do Joelho/complicações , Traumatismos do Joelho/patologia , Traumatismos do Joelho/fisiopatologia , Articulação do Joelho/patologia , Articulação do Joelho/fisiopatologia , Osteoartrite do Joelho/etiologia , Osteoartrite do Joelho/patologia , Osteoartrite do Joelho/fisiopatologia , Ovinos
8.
Osteoarthr Cartil Open ; 2(4): 100109, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36474890

RESUMO

Objective: There is a high risk of developing osteoarthritis (OA) following traumatic injury to the knee. Severe ligament injuries can disrupt the integrity of the multicomponent knee at both biological and biomechanical levels. We hypothesize changes in cartilages stresses could lead to tissue damage and development of OA. Design: The in-vivo gait kinematics of the stifle (knee) joint of four adult female ovine subjects were recorded prior to and at ten-and-twenty weeks following partial ACL-MCL transection. The subjects were sacrificed and the experimental joint from each subject was mounted on a parallel robotic system programmed with the kinematic findings. Ten custom-built Fibre Bragg Grating optic sensors were arranged to measure contact stresses on the surface of the tibial plateau articular cartilage. These sensors provide the first accurate stress measurements in a joint during gait replication using the previously recorded in-vivo kinematics. The relationship between the results obtained and observed focal damage was assessed. Results: The locations on the tibial plateaus that experienced the greatest change in contact stresses corresponded with the locations of focal damage development. No direct link was detected between individual animal differences in kinematics and variations in stress magnitudes or the development of focal cartilage damage. Conclusions: The findings highlight the importance of mechanical stress determinants in the integrated set point for the knee (with individual variation), and how injury-related stress changes correlate with development of PTOA.

9.
Ann Biomed Eng ; 48(12): 2836-2845, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32342234

RESUMO

It has been hypothesized a change in stress on the cartilage of a joint is a significant factor in the initiation and progression of post-traumatic osteoarthritis. Without a reliable method for measuring stress, this hypothesis has largely gone untested. In this study, a novel, repeatable, and reliable method for measuring stress on the surface of articular cartilage in articular joints is presented. Small Fiber Bragg Grating (FBG) sensors capable of measuring normal stress between contact surfaces in diarthrodial joints were developed and validated. The small size of these sensors (diameter of 125-300 µm and sensing length of 1 mm) allows them to be inserted into the joint space without the removal of biomechanically relevant structures. In-vitro stresses on the surface of the cartilage for both healthy and surgically damaged joints were measured after implantation of the FBG sensors using in vivo generated gait kinematic data and a 6-degrees of freedom parallel robot. Along with our capability to reproduce in vivo motions accurately and the improvements in fiber optic technology, this study describes the first direct measurement of stress in a joint using in vivo gait kinematics.


Assuntos
Cartilagem Articular/fisiologia , Tecnologia de Fibra Óptica , Marcha/fisiologia , Articulação do Joelho/fisiologia , Animais , Fenômenos Biomecânicos , Feminino , Fêmur/fisiologia , Ovinos , Estresse Mecânico , Tíbia/fisiologia
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa