Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
2.
J Chromatogr B Analyt Technol Biomed Life Sci ; 877(14-15): 1465-71, 2009 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-19346171

RESUMO

Telcagepant (MK-0974) is a novel oral calcitonin gene-related peptide (CGRP) receptor antagonist and is currently under clinical development. Results from phases II and III clinical trials have suggested that telcagepant is effective for migraine treatment. A reliable and high throughput protein precipitation (PPT) method for determination of telcagepant in human plasma using liquid chromatography coupled with atmospheric pressure chemical ionization (APCI) tandem mass spectrometry has been developed. Clinical samples, internal standard (IS) and acetonitrile are transferred into 96-well plates using a robotic liquid handling system. An aliquot of 10 microL supernatant is directly injected into the LC-MS/MS system where separation is performed on a FluoPhase RP (150 x 2.1mm, 5 microm) column with an isocratic mobile phase (60% acetonitrile with 0.1% formic acid and 40% water with 0.1% formic acid) at 0.2 mL/min. The interfering 3S-diastereomer of telcagepant, which is observed in clinical samples, is chromatographically resolved from telcagepant. The PPT procedure significantly reduces the time required for sample processing and the assay is sufficiently sensitive for detection using both API 4000 and API 3000 mass spectrometers. The linear calibration range is 5-5000 nM using 200 microL of plasma. Assay intraday validation was conducted using six calibration curves derived from six lots of human control plasma. Calibration standard accuracy did not deviate by more than 3% and 6% of nominal values, and precision did not exceed 4% coefficient of variation (CV) and 10% CV, respectively on the API 4000 and API 3000. Several clinical phases IIb and III studies have been successfully supported with this assay.


Assuntos
Azepinas/sangue , Cromatografia Líquida de Alta Pressão/métodos , Imidazóis/sangue , Espectrometria de Massas em Tandem/métodos , Humanos , Transtornos de Enxaqueca/sangue , Transtornos de Enxaqueca/tratamento farmacológico
3.
J Pharmacol Toxicol Methods ; 57(1): 61-9, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-17651990

RESUMO

INTRODUCTION: A Tecan-based enzyme inhibition assay has been developed for the determination of atorvastatin-derived 'active' and 'total' (active inhibitors plus atorvastatin lactone and other potential inhibitors following base hydrolysis) 3-hydroxy-3-methylglutaryl-Coenzyme A (HMG-CoA) reductase inhibitor concentrations in human plasma. Atorvastatin is an inhibitor of HMG-CoA reductase, which is a key rate-limiting enzyme in the cholesterol biosynthesis. Previously, atorvastatin-derived HMG-CoA reductase inhibitors were measured via enzyme inhibition assays by manual operation. METHODS: In this work, an enzyme assay procedure based on 8-tip Tecan robotics and set-up in a 96-well plate format with customized hardware is presented. Following protein precipitation of the plasma sample, an aliquot of the resulting supernatant is mixed with HMG-CoA reductase and (14)C-labeled HMG-CoA prior to incubation. The product, (14)C-mevalonic acid, is lactonized, separated from unreacted (14)C-substrate, and counted in a liquid scintillation counter. Plasma HMG-CoA reductase inhibitor concentrations are measured against atorvastatin as the standard. Tecan Genesis 150 and 200 robotic workstations were used for the protein precipitation, enzyme incubation, and product separation. RESULTS: The standard calibration range for the assay was 0.4-20 ng eq/mL. Intra-day precision (%CV) data for the calibration standard and quality control (QC) samples (n=5 replicates) were both

Assuntos
Ácidos Heptanoicos/análise , Ácidos Heptanoicos/sangue , Hidroximetilglutaril-CoA Redutases/metabolismo , Inibidores de Hidroximetilglutaril-CoA Redutases/sangue , Pirróis/análise , Pirróis/sangue , Atorvastatina , Ácidos Heptanoicos/química , Humanos , Indicadores e Reagentes , Estrutura Molecular , Pirróis/química , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa