Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 109
Filtrar
1.
Biochem Biophys Res Commun ; 552: 17-22, 2021 05 07.
Artigo em Inglês | MEDLINE | ID: mdl-33740660

RESUMO

Serine proteases are fundamental components of biology, including innate immunity, which is systematically orchestrated in an orderly, balanced fashion in the healthy host. Such serine proteases are found in two well-recognized pathways of an innate immune network, coagulation and complement. Both pathways, if uncontrolled due to a variety of causes, are pathogenic in numerous diseases, including coagulation disorders and infectious diseases. Previous studies have reported sequence homologies, functional similarities and interplay between these two pathways with some implications in health and disease. The current study newly reveals that complement component factor B (Bf), the second component of the alternative complement pathway, has thrombin-like activity, which is supported by a characteristic homology of the trypsin-like domain of Bf to that of thrombin. Moreover, we newly report that the trypsin-like domain of Bf is closely related to Limulus clotting factor C, the LPS sensitive clotting factor of the innate immune system. We will also discuss potential implications of our findings in diseases.


Assuntos
Fator B do Complemento/genética , Trombina/genética , Tripsina/genética , Sequência de Aminoácidos , Animais , Sítios de Ligação/genética , Fator B do Complemento/classificação , Fator B do Complemento/metabolismo , Variação Genética , Humanos , Camundongos Endogâmicos C57BL , Camundongos Knockout , Filogenia , Homologia de Sequência de Aminoácidos , Trombina/metabolismo , Tripsina/metabolismo
2.
Haemophilia ; 27(6): e713-e720, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34455654

RESUMO

BACKGROUND: Laboratory diagnosis of von Willebrand Disease (VWD) is complex. Reliance on laboratory testing can be problematic as different VWD screening panels, assays and methodologies can produce analytic variability in test results. OBJECTIVES: To compare the degree of imprecision among the VWD assays and within the platelet binding activity (PBA) assays, to determine the consensus among the VWD assays for correct classification of sample results, and to determine consensus among laboratories' von Willebrand factor (VWF) multimer interpretations and final interpretations of the VWD panels. PATIENTS/METHODS: Proficiency testing results from the North American Specialized Coagulation Laboratory Association (NASCOLA) submitted by laboratories from 2010 to 2019 for all normal, type (T) 1 VWD and T2 VWD samples were analysed. RESULTS AND CONCLUSIONS: Imprecision was lowest for VWF antigen and highest for collagen binding activity (CBA) with median coefficient of variation (CV) of 12% (interquartile range (IQR) 7%) and 23% (IQR 21%) respectively. Within the VWF PBA assays, the gain-of-function mutant GP1b binding (VWF: GP1bM) methods had the least imprecision (CV 9%, IQR 10%). All assays, including the various PBA methods had excellent consensus. The majority of laboratories agreed that normal (median consensus-82%, IQR 16%) and T1 VWD (median consensus-100%, IQR 9%) samples had normal multimer distribution. Consensus among laboratories for final interpretations was excellent for normal samples (median 81%, IQR 8%), good for T1 VWD samples (median 59%, IQR 9%), and fair for T2 VWD samples (median 44%, IQR 21%). Consensus on final interpretation decreased as sample complexity increased.


Assuntos
Doenças de von Willebrand , Testes de Coagulação Sanguínea , Humanos , Laboratórios , América do Norte , Doenças de von Willebrand/diagnóstico , Fator de von Willebrand
3.
Am J Hematol ; 96(8): 968-978, 2021 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-33971046

RESUMO

During cardiac surgery with cardiopulmonary bypass (CPB), altered hemostatic balance may disrupt fibrin assembly, predisposing patients to perioperative hemorrhage. We investigated the utility of a novel device termed spectrally-encoded confocal microscopy (SECM) for assessing fibrin clot polymerization following heparin and protamine administration in CPB patients. SECM is a novel, high-speed optical approach to visualize and quantify fibrin clot formation in three dimensions with high spatial resolution (1.0 µm) over a volumetric field-of-view (165 × 4000 × 36 µm). The measurement sensitivity of SECM was first determined using plasma samples from normal subjects spiked with heparin and protamine. Next, SECM was performed in plasma samples from patients on CPB to quantify the extent to which fibrin clot dynamics and microstructure were altered by CPB exposure. In spiked samples, prolonged fibrin time (4.4 ± 1.8 to 49.3 ± 16.8 min, p < 0.001) and diminished fibrin network density (0.079 ± 0.010 to 0.001 ± 0.002 A.U, p < 0.001) with increasing heparin concentration were reported by SECM. Furthermore, fibrin network density was not restored to baseline levels in protamine-treated samples. In CPB patients, SECM reported lower fibrin network density in protaminized samples (0.055 ± 0.01 A.U. [Arbitrary units]) vs baseline values (0.066 ± 0.009 A.U.) (p = 0.03) despite comparable fibrin time (baseline = 6.0 ± 1.3, protamine = 6.4 ± 1.6 min, p = 0.5). In these patients, additional metrics including fibrin heterogeneity, length and straightness were quantified. Note, SECM revealed that following protamine administration with CPB exposure, fibrin clots were more heterogeneous (baseline = 0.11 ± 0.02 A.U, protamine = 0.08 ± 0.01 A.U, p = 0.008) with straighter fibers (baseline = 0.918 ± 0.003A.U, protamine = 0.928 ± 0.0006A.U. p < 0.001). By providing the capability to rapidly visualize and quantify fibrin clot microstructure, SECM could furnish a new approach for assessing clot stability and hemostasis in cardiac surgical patients.


Assuntos
Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Fibrina/ultraestrutura , Microscopia Confocal/métodos , Coagulação Sanguínea/efeitos dos fármacos , Feminino , Humanos , Masculino
4.
Semin Thromb Hemost ; 46(7): 845-849, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32877961

RESUMO

Over the past few months, Coronavirus Disease 2019 (COVID-19) has spread across much of the world leading to a pandemic. Many infected individuals do not experience signs or symptoms, or experience only mild symptoms, whilst a subset experience severe disease, which is often fatal. A number of laboratory tests have been found to be abnormal in hospitalized patients, and some studies suggest some of these tests can predict an unfavorable outcome. These include markers of acute phase reaction (elevated C-reactive protein, erythrocyte sedimentation rate, white blood cell count, fibrinogen, procalcitonin, factor VIII, von Willebrand factor), signs of tissue injury (elevated lactic dehydrogenase, alanine aminotransferase, cardiac troponins), changes in hemostasis and coagulation (elevated D-dimer, prolonged prothrombin time, decreased platelets, decreased antithrombin, elevated factor VIII and von Willebrand factor), and decreased lymphocytes. Additional studies are needed to confirm the most ideal panel of tests, and to confirm the efficiency of laboratory tests to predict clinical outcome, as well as the ideal anticoagulation management.


Assuntos
Técnicas de Laboratório Clínico/métodos , Infecções por Coronavirus/sangue , Infecções por Coronavirus/terapia , Pneumonia Viral/sangue , Pneumonia Viral/terapia , Anticoagulantes/sangue , Betacoronavirus , Transtornos da Coagulação Sanguínea/complicações , Transtornos da Coagulação Sanguínea/tratamento farmacológico , COVID-19 , Teste para COVID-19 , Infecções por Coronavirus/diagnóstico , Cuidados Críticos , Hematologia/normas , Humanos , Unidades de Terapia Intensiva , Pandemias , Prognóstico , Risco , SARS-CoV-2 , Resultado do Tratamento
5.
Am J Hematol ; 95(12): 1479-1485, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32780525

RESUMO

Coronavirus disease 2019 (COVID-19) may cause a hypercoagulable state. The D-dimer is frequently elevated in COVID-19, but other markers of coagulation activation, including the prothrombin fragment 1.2 (PF1.2) are poorly described. We studied hospitalized adults with COVID-19 and PF1.2 measurements performed at any time during hospitalization. We evaluated the relationship between PF1.2 and synchronously measured D-dimer. We utilized receiver operating characteristic (ROC) analysis to evaluate optimal thresholds for diagnosing thrombosis and multivariable logistic regression to evaluate association with thrombosis. A total of 115 patients were included [110 (95.7%) critically ill]. Both PF1.2 and D-dimer were moderately positively correlated (r = 0.542, P < .001) but significant discordance was observed in elevation of each marker above the laboratory reference range (59.0% elevated PF1.2 vs 98.5% elevated D-dimer). Median PF1.2 levels were higher in patients with thrombosis than those without (611 vs 374 pmol/L, P = .006). In ROC analysis, PF1.2 had superior specificity and conferred a higher positive likelihood ratio in identifying patients with thrombosis than D-dimer (PF1.2 threshold of >523 pmol/L: 69.2% sensitivity, 67.7% specificity; >924 pmol/L: 37.9% sensitivity, 87.8% specificity). In multivariable analysis, a PF1.2 >500 pmol/L was significantly associated with VTE [adjusted odds ratio (OR) 4.26, 95% CI, 1.12-16.21, P = .034] and any thrombotic manifestation (adjusted OR 3.85, 95% CI, 1.39-10.65, P = .010); conversely, synchronously measured D-dimer was not significantly associated with thrombosis. 90.6% of patients with a non-elevated PF1.2 result did not develop VTE. So, PF1.2 may be a useful assay, and potentially more discriminant than D-dimer, in identifying thrombotic manifestations in hospitalized patients with COVID-19.


Assuntos
COVID-19/sangue , Fragmentos de Peptídeos/sangue , SARS-CoV-2 , Trombose/sangue , Idoso , Biomarcadores/sangue , Estado Terminal , Feminino , Produtos de Degradação da Fibrina e do Fibrinogênio/análise , Hospitalização , Humanos , Masculino , Pessoa de Meia-Idade , Protrombina , Curva ROC , Sensibilidade e Especificidade , Tromboembolia Venosa/sangue
6.
Am J Hematol ; 95(12): 1522-1530, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32833259

RESUMO

Coagulopathy causes morbidity and mortality in patients with coronavirus disease 2019 (COVID-19) due to severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) infection. Yet, the mechanisms are unclear and biomarkers are limited. Early in the pandemic, we observed markedly elevated factor V activity in a patient with COVID-19, which led us to measure factor V, VIII, and X activity in a cohort of 102 consecutive inpatients with COVID-19. Contemporaneous SARS-CoV-2-negative controls (n = 17) and historical pre-pandemic controls (n = 260-478) were also analyzed. This cohort represents severe COVID-19 with high rates of ventilator use (92%), line clots (47%), deep vein thrombosis or pulmonary embolism (DVT/PE) (23%), and mortality (22%). Factor V activity was significantly elevated in COVID-19 (median 150 IU/dL, range 34-248 IU/dL) compared to contemporaneous controls (median 105 IU/dL, range 22-161 IU/dL) (P < .001)-the strongest association with COVID-19 of any parameter studied, including factor VIII, fibrinogen, and D-dimer. Patients with COVID-19 and factor V activity >150 IU/dL exhibited significantly higher rates of DVT/PE (16/49, 33%) compared to those with factor V activity ≤150 IU/dL (7/53, 13%) (P = .03). Within this severe COVID-19 cohort, factor V activity associated with SARS-CoV-2 load in a sex-dependent manner. Subsequent decreases in factor V were linked to progression toward DIC and mortality. Together, these data reveal marked perturbations of factor V activity in severe COVID-19, provide links to SARS-CoV-2 disease biology and clinical outcomes, and nominate a candidate biomarker to investigate for guiding anticoagulation therapy in COVID-19.


Assuntos
COVID-19/sangue , Fator V/análise , SARS-CoV-2 , Tromboembolia Venosa/sangue , Adulto , Idoso , Idoso de 80 Anos ou mais , COVID-19/mortalidade , COVID-19/terapia , Estudos de Coortes , Coagulação Intravascular Disseminada/sangue , Oxigenação por Membrana Extracorpórea , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Embolia Pulmonar/sangue , Respiração Artificial , Índice de Gravidade de Doença , Fatores Sexuais , Trombose Venosa/sangue
8.
Ann Hematol ; 98(3): 581-588, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30446804

RESUMO

The thrombopoietin receptor agonist romiplostim is used for the long-term treatment of chronic immune thrombocytopenia (ITP). ITP patients have an increased thrombotic risk, which could be exacerbated if romiplostim increased platelet hyperreactivity or caused spontaneous platelet aggregation. To investigate this possibility, this study examined platelet function in romiplostim-treated ITP patients and healthy subjects. Light transmission platelet aggregometry utilizing arachidonic acid, collagen, epinephrine, ristocetin, ADP, and saline (to assess spontaneous aggregation) was performed for each subject. In addition, the ADP AC50 (ADP concentration that induced half-maximal aggregation) was determined for each patient as a sensitive measurement of altered platelet reactivity. Fifteen ITP patients and 7 healthy subjects entered the study. All ITP patients had active disease and were receiving weekly romiplostim as the sole ITP-directed therapy. Platelet aggregation in response to the strong agonists arachidonic acid, collagen, and ristocetin was not significantly different between ITP patients and healthy subjects (P = 0.2442, P = 0.0548, and P = 0.0879, respectively). Platelet aggregation in response to weak agonists was significantly reduced in ITP patients compared with that in healthy subjects: median (range) aggregation to ADP, 45% (15-84%) versus 89% (70-95%) (P = 0.0010), and epinephrine, 21% (1.6-90%) versus 88% (79-94%) (P = 0.0085). The median AC50 of ADP was threefold higher in ITP patients versus that in healthy subjects (6.3 µM vs 2.1 µM) (P = 0.0049). Significant spontaneous aggregation was not observed in any patient. Platelets from romiplostim-treated ITP patients do not show evidence for spontaneous aggregation or hyperreactivity, but instead have a modestly reduced aggregation response to ADP and epinephrine.


Assuntos
Transtornos Plaquetários/induzido quimicamente , Púrpura Trombocitopênica Idiopática/tratamento farmacológico , Receptores Fc/uso terapêutico , Proteínas Recombinantes de Fusão/uso terapêutico , Trombopoetina/uso terapêutico , Difosfato de Adenosina/farmacologia , Adulto , Idoso , Ácido Araquidônico/farmacologia , Colágeno/farmacologia , Epinefrina/farmacologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Agregação Plaquetária/efeitos dos fármacos , Púrpura Trombocitopênica Idiopática/sangue , Receptores de Trombopoetina/agonistas , Proteínas Recombinantes de Fusão/efeitos adversos , Proteínas Recombinantes de Fusão/farmacologia , Ristocetina/farmacologia , Trombofilia/induzido quimicamente , Trombopoetina/efeitos adversos , Trombopoetina/farmacologia , Adulto Jovem
9.
Am J Hematol ; 94(6): 697-709, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-30916798

RESUMO

Two specific reversal agents for direct oral anticoagulants (DOACs) have been approved in the United States: idarucizumab for dabigatran reversal and andexanet alfa for apixaban and rivaroxaban reversal. Non-specific prohemostatic agents such as prothrombin complex concentrate (PCC) and activated PCC have also been used for DOAC reversal. The goal of this document is to provide comprehensive guidance from the Anticoagulation Forum, a North American organization of anticoagulation providers, regarding use of DOAC reversal agents. We discuss indications for reversal, provide guidance on how the individual reversal agents should be administered, and offer suggestions for stewardship at the health system level.


Assuntos
Anticorpos Monoclonais Humanizados/uso terapêutico , Anticoagulantes/efeitos adversos , Fator Xa/uso terapêutico , Proteínas Recombinantes/uso terapêutico , Anticoagulantes/uso terapêutico , Humanos , Guias de Prática Clínica como Assunto
10.
Clin Chem Lab Med ; 57(1): 115-126, 2018 12 19.
Artigo em Inglês | MEDLINE | ID: mdl-29668440

RESUMO

Quality in diagnostic testing represents a key target of laboratory medicine, for which an assurance around the quality of testing is expected from all involved in the process. Laboratories attempt to assure the quality of their testing by various processes, but especially by performance of internal quality control and external quality assessment (EQA). This is especially true for tests of hemostasis and coagulation. EQA in general provides information on test accuracy and on evaluation of long-term laboratory performance. EQA providers support laboratory performance by various means, including distribution of material for testing of analytes ("proficiency testing"), educational support through expert advice, distribution of publications or case series. Participation in EQA is often a laboratory accreditation requirement. This review aims to identify some of the strengths and weaknesses of EQA, and targets attempts towards harmonization of EQA practice, in order to achieve the best outcome for participant laboratories and, thus, for patients and their clinical care providers.


Assuntos
Hemostasia , Ensaio de Proficiência Laboratorial/normas , Garantia da Qualidade dos Cuidados de Saúde/normas , Coagulação Sanguínea , Humanos
11.
Platelets ; 29(6): 574-582, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-29863946

RESUMO

Platelet transmission electron microscopy (PTEM) is considered the gold standard test for assessing distinct ultrastructural abnormalities in inherited platelet disorders (IPDs). Nevertheless, PTEM remains mainly a research tool due to the lack of standardized procedures, a validated dense granule (DG) count reference range, and standardized image interpretation criteria. The aim of this study was to standardize and validate PTEM as a clinical laboratory test. Based on previously established methods, we optimized and standardized preanalytical, analytical, and postanalytical procedures for both whole mount (WM) and thin section (TS) PTEM. Mean number of DG/platelet (plt), percentage of plts without DG, platelet count (PC), mean platelet volume (MPV), immature platelet fraction (IPF), and plt light transmission aggregometry analyses were measured on blood samples from 113 healthy donors. Quantile regression was used to estimate the reference range for DG/plt, and linear regression was used to assess the association of DG/plt with other plt measurements. All PTEM procedures were standardized using commercially available materials and reagents. DG interpretation criteria were established based on previous publications and expert consensus, and resulted in improved operator agreement. Mean DG/plt was stable for 2 days after blood sample collection. The median within patient coefficient of variation for mean DG/plt was 22.2%; the mean DG/plt reference range (mid-95th %) was 1.2-4.0. Mean DG/plt was associated with IPF (p = .01, R2 = 0.06) but not age, sex, PC, MPV, or plt maximum aggregation or primary slope of aggregation (p > .17, R2 < 0.02). Baseline ultrastructural features were established for TS-PTEM. PTEM was validated using samples from patients with previously established diagnoses of IPDs. Standardization and validation of PTEM procedures and interpretation, and establishment of the normal mean DG/plt reference range and PTEM baseline ultrastructural features, will facilitate implementation of PTEM as a valid clinical laboratory test for evaluating ultrastructural abnormalities in IPDs.


Assuntos
Plaquetas/metabolismo , Microscopia Eletrônica de Transmissão/métodos , Valores de Referência , Humanos
12.
Semin Thromb Hemost ; 43(3): 270-276, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28052306

RESUMO

Argatroban and bivalirudin are parenteral direct inhibitors of the activity of thrombin, but, unlike heparin, can inhibit both soluble as well as clot-bound thrombin. These agents do not require antithrombin as a cofactor for activity. The parenteral direct thrombin inhibitors (DTIs) can be used in a variety of settings, including heparin-induced thrombocytopenia (HIT) or an allergy to heparin, and patients requiring anticoagulation for an invasive cardiovascular intervention. Both agents have a relatively short half-life in patients without organ system failure and are typically administered by continuous infusion. Argatroban is primarily eliminated by the liver, while bivalirudin is removed by a combination of proteolytic cleavage by thrombin and renal clearance mechanisms. Several laboratory tests are available for monitoring the anticoagulant effects of the DTIs: the activated partial thromboplastin time (aPTT) and the activated clotting time (ACT) are the most commonly used assays, but on occasion, the thrombin time may be useful. Other coagulation assays such as the dilute thrombin time (dTT), chromogenic anti-IIa assays, and the ecarin clotting time (ECT) can be used. The intensity of anticoagulation with DTIs depends on the indication for use. For patients with HIT, the target aPTT is 1.5 to 3.0 and 1.5 to 2.5 times the patient's baseline value for argatroban and bivalirudin, respectively. DTI anticoagulation used during percutaneous coronary intervention can be measured using ACT. Both DTIs may cause an elevation in the international normalized ratio depending on their plasma concentration. This article will review the use of parenteral DTIs and related laboratory assays for assessing the anticoagulant effect of these drugs.


Assuntos
Antitrombinas/uso terapêutico , Monitoramento de Medicamentos/métodos , Sistemas Automatizados de Assistência Junto ao Leito , Trombina/antagonistas & inibidores , Antitrombinas/administração & dosagem , Arginina/análogos & derivados , Hirudinas/administração & dosagem , Humanos , Infusões Parenterais , Tempo de Tromboplastina Parcial/métodos , Fragmentos de Peptídeos/administração & dosagem , Fragmentos de Peptídeos/uso terapêutico , Ácidos Pipecólicos/administração & dosagem , Ácidos Pipecólicos/uso terapêutico , Proteínas Recombinantes/administração & dosagem , Proteínas Recombinantes/uso terapêutico , Sulfonamidas , Trombina/metabolismo , Tempo de Trombina/métodos
13.
Am J Hematol ; 91(1): 46-9, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26492443

RESUMO

Factor V Leiden (FVLeiden ) is a common hereditary thrombophilia that causes activated protein C (APC) resistance. This review describes many of the most fascinating features of FVLeiden , including background features, mechanisms of hypercoagulability, the founder mutation concept, the "FVLeiden paradox," synergistic interaction with other thrombotic risk factors, the intertwined relationship between FVLeiden and APC resistance testing, and other, uncommon mutations implicated in causing APC resistance. In addition, there are several conditions where laboratory tests for APC resistance and FVLeiden are or can be discrepant, including lupus anticoagulants, anticoagulants such as direct thrombin inhibitors (dabigatran, argatroban, and bivalirudin) and rivaroxaban, as well as pseudohomozygous, pseudo-wildtype, liver transplant, and bone marrow transplant patients. The laboratory test error rate for FVLeiden is also presented.


Assuntos
Resistência à Proteína C Ativada , Fator V/genética , Resistência à Proteína C Ativada/sangue , Resistência à Proteína C Ativada/etiologia , Resistência à Proteína C Ativada/genética , Anticoagulantes/uso terapêutico , Coagulação Sanguínea , Testes de Coagulação Sanguínea , Análise Mutacional de DNA , Humanos , Lúpus Eritematoso Sistêmico/sangue , Lúpus Eritematoso Sistêmico/complicações , Mutação Puntual
14.
Am J Hematol ; 91(11): E464-E467, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27458812

RESUMO

Rivaroxaban and dabigatran are among the newest anticoagulants, and measuring their concentration in patients is a new challenge for clinical laboratories. We analyzed data from the ECAT proficiency program to determine how well the assays are performing in clinical laboratories internationally. Most laboratories received a passing grade (Z score <3) for the results of their dabigatran and rivaroxaban testing. Failing Z scores were not associated with any particular method. With dabigatran, some homemade calibrators gave higher results than the commercially available calibrators. There were no significant differences among the instruments or the 5 reagents in use, but results showed inter-laboratory variability that could have clinical significance. The 3 reagents with the lowest number of users had poor inter-laboratory precision. Ten different anti-Xa reagents were in use for rivaroxaban testing. One reagent gave lower results than other reagents at 100 ng/mL but not at 300 ng/mL. There were no significant differences among the different rivaroxaban calibrators or instruments. In conclusion, inter-laboratory precision could be improved for both dabigatran and rivaroxaban assays. Homemade dabigatran calibrators differed from commercially available calibrators, and there was a statistically significant difference between some of the rivaroxaban reagents. About 10% of results received failing Z scores or passed but fell in a range that require the laboratory to investigate for bias or other inaccuracy in their method. Am. J. Hematol. 91:E464-E467, 2016. © 2016 Wiley Periodicals, Inc.


Assuntos
Testes de Coagulação Sanguínea/normas , Serviços de Laboratório Clínico/normas , Dabigatrana/farmacologia , Rivaroxabana/farmacologia , Anticoagulantes/farmacologia , Antitrombinas , Calibragem , Inibidores do Fator Xa , Humanos , Indicadores e Reagentes , Variações Dependentes do Observador
15.
Semin Thromb Hemost ; 40(2): 254-60, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24497121

RESUMO

Between 2010 and 2012, North American Specialized Coagulation Laboratory Association (NASCOLA) distributed five proficiency testing challenges to evaluate laboratory testing for heparin-induced thrombocytopenia (HIT). Results (n = 355) were submitted from 43 unique laboratories for 10 samples (3 positive, 2 weak positive, and 5 negative). The vast majority of results were from commercial enzyme-linked immunosorbent assay (ELISA) methods, predominantly polyvalent assays. Laboratories performed well in the classification of clear negative and positive samples. All results (100%) submitted for the five negative samples (n = 173) and 97% of immunological results submitted for the three positive samples (n = 105) were correctly classified (the incorrect responses were two borderline classifications and, from a gel-agglutination method, one negative classification). There was more difficulty in the classification of the two weak positive samples (n = 70). In one survey, 61% of results from the weak positive sample were classified as positive, while 21% were called negative, 16% were called borderline, and 2% were called inconclusive. In a second survey, 16% of results from the weak positive sample were called positive, while 56% were called negative, and 28% were called borderline. Significant interlaboratory variation was observed for ELISA results, with coefficients of variation of about 20 to 30%. We conclude that there is variability in HIT laboratory testing and that identification of weak positive samples can be challenging.


Assuntos
Testes de Coagulação Sanguínea/normas , Heparina/efeitos adversos , Ensaio de Proficiência Laboratorial/estatística & dados numéricos , Trombocitopenia/diagnóstico , Anticoagulantes/efeitos adversos , Testes de Coagulação Sanguínea/métodos , Coleta de Dados/métodos , Coleta de Dados/estatística & dados numéricos , Ensaio de Imunoadsorção Enzimática/métodos , Ensaio de Imunoadsorção Enzimática/normas , Humanos , Ensaio de Proficiência Laboratorial/métodos , América do Norte , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Trombocitopenia/sangue , Trombocitopenia/induzido quimicamente
16.
Semin Thromb Hemost ; 40(2): 232-8, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24497117

RESUMO

We analyzed results from the External quality Control of diagnostic Assays and Tests program to assess current clinical laboratory practice and performance of different methods for factor XIII (FXIII) testing internationally. FXIII proficiency testing data from all eight surveys conducted in 2010 and 2011 were analyzed (1,283 results), comparing the three available methods for detecting FXIII deficiency, thus including clot-solubility qualitative activity, quantitative activity, and antigen. Clot-solubility qualitative assays detected a deficiency in only 16% (11/69) of samples with less than 2% FXIII. Assays using added thrombin detected more deficiencies (33%) than did assays without added thrombin (11%). The most commonly used quantitative activity method tended to produce higher results for low FXIII samples than other quantitative activity methods. Antigen results generally showed good accuracy compared with expected levels. The mean interlaboratory coefficients of variation showed wide variability, especially for samples with less than 10% FXIII activity. Laboratory self-classification of results (as normal vs. abnormal) was good, and was slightly better for specimens with ≤ 25% FXIII than for specimens with 26 to 70% or those with >70% FXIII. We conclude that quantitative activity assays perform better for detecting FXIII deficiency than clot solubility assays, although some quantitative activity assays overestimate low FXIII levels.


Assuntos
Técnicas de Laboratório Clínico/normas , Deficiência do Fator XIII/sangue , Deficiência do Fator XIII/diagnóstico , Fator XIII/análise , Técnicas de Laboratório Clínico/métodos , Humanos , Cooperação Internacional , Ensaio de Proficiência Laboratorial/métodos , Ensaio de Proficiência Laboratorial/estatística & dados numéricos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
17.
Am J Hematol ; 89(12): 1147-50, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25293789

RESUMO

Activated protein C resistance assays can detect factor V Leiden with high accuracy, depending on the method used. Factor Xa inhibitors such as rivaroxaban and direct thrombin inhibitors including dabigatran, argatroban, and bivalirudin can cause falsely normal results. Lupus anticoagulants can cause incorrect results in most current assays. Assays that include dilution into factor V-deficient plasma are needed to avoid interference from factor deficiencies or elevations, which can arise from a wide variety of conditions such as warfarin, liver dysfunction, or pregnancy. The pros and cons of the currently available assays are discussed.


Assuntos
Resistência à Proteína C Ativada/diagnóstico , Bioensaio/normas , Fator V/análise , Proteína C/metabolismo , Resistência à Proteína C Ativada/sangue , Adulto , Antitrombinas/química , Arginina/análogos & derivados , Benzimidazóis/química , Testes de Coagulação Sanguínea , Criança , Dabigatrana , Fator V/metabolismo , Fator Xa/metabolismo , Reações Falso-Positivas , Feminino , Hirudinas/química , Humanos , Inibidor de Coagulação do Lúpus/química , Morfolinas/química , Fragmentos de Peptídeos/química , Ácidos Pipecólicos/química , Gravidez , Proteínas Recombinantes/química , Rivaroxabana , Sulfonamidas , Tiofenos/química , Varfarina/química , beta-Alanina/análogos & derivados , beta-Alanina/química
19.
Xenotransplantation ; 21(5): 454-64, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25130043

RESUMO

BACKGROUND: Pig to baboon liver xenotransplantation typically results in severe thrombocytopenia and coagulation disturbances, culminating in death from hemorrhage within 9 days, in spite of continuous transfusions. We studied the contribution of anticoagulant production and clotting pathway deficiencies to fatal bleeding in baboon recipients of porcine livers. METHODS: By transplanting liver xenografts from α1,3-galactosyltransferase gene-knockout (GalT-KO) miniature swine donors into baboons as auxiliary organs, leaving the native liver in place, we provided the full spectrum of primate clotting factors and allowed in vivo mixing of porcine and primate coagulation systems. RESULTS: Recipients of auxiliary liver xenografts develop severe thrombocytopenia, comparable to recipients of conventional orthotopic liver xenografts and consistent with hepatic xenograft sequestration. However, baboons with both pig and native livers do not exhibit clinical signs of bleeding and maintain stable blood counts without transfusion for up to 8 consecutive days post-transplantation. Instead, recipients of auxiliary liver xenografts undergo graft failure or die of sepsis, associated with thrombotic microangiopathy in the xenograft, but not the native liver. CONCLUSION: Our data indicate that massive hemorrhage in the setting of liver xenotransplantation might be avoided by supplementation with primate clotting components. However, coagulation competent hepatic xenograft recipients may be predisposed to graft loss related to small vessel thrombosis and ischemic necrosis.


Assuntos
Transplante de Fígado/métodos , Hemorragia Pós-Operatória/prevenção & controle , Transplante Heterólogo/métodos , Animais , Animais Geneticamente Modificados , Biomarcadores/sangue , Fatores de Coagulação Sanguínea/metabolismo , Transfusão de Sangue , Rejeição de Enxerto , Sobrevivência de Enxerto , Papio , Complicações Pós-Operatórias/terapia , Hemorragia Pós-Operatória/etiologia , Hemorragia Pós-Operatória/mortalidade , Hemorragia Pós-Operatória/terapia , Suínos/genética , Trombocitopenia/etiologia , Trombocitopenia/terapia
20.
J Thromb Thrombolysis ; 38(3): 331-8, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24474086

RESUMO

Collectin kidney 1 (CL-K1) is a recently identified collectin that is synthesized in most organs and circulates in blood. CL-K1 is an innate immune molecule that may play a significant role in host defense. As some collectins also play a role in coagulation, we hypothesized that an effect of CL-K1 may be apparent in disseminated intravascular coagulation (DIC), a gross derangement of the coagulation system that occurs in the setting of profound activation of the innate immune system. DIC is a grave medical condition with a high incidence of multiple organ failure and high mortality and yet there are no reliable biomarkers or risk factors. In our present study, we measured plasma CL-K1 concentration in a total of 659 specimens, including 549 DIC patients, 82 non-DIC patients and 27 healthy volunteers. The median plasma CL-K1 levels in these cohorts were 424, 238 and 245 ng/ml, respectively, with no significant difference in the latter two groups. The incidence of elevated plasma CL-K1 was significantly higher in the DIC patients compared to the non-DIC patients, resulting in an odds ratio of 1.929 (confidence interval 1.041-3.866). Infection, renal diseases, respiratory diseases, and cardiac diseases were more frequently observed in the DIC group than in the non-DIC group. In the DIC group, vascular diseases were associated with elevated plasma CL-K1 levels while age and acute illness had little effect on plasma CL-K1 levels. Independent of DIC, elevated plasma CL-K1 levels were associated with respiratory disease and coagulation disorders. These results suggest that specific diseases may affect CL-K1 synthesis in an organ dependent manner and that elevated plasma CL-K1 levels are associated with the presence of DIC. Further investigations in cohorts of patients are warranted. We propose that elevated plasma CL-K1 may be a new useful risk factor and possibly biomarker for the prediction of developing DIC.


Assuntos
Colectinas/sangue , Coagulação Intravascular Disseminada/sangue , Fatores Etários , Idoso , Biomarcadores/sangue , Transtornos da Coagulação Sanguínea/sangue , Estudos de Coortes , Humanos , Masculino , Pessoa de Meia-Idade , Doenças Respiratórias/sangue , Fatores de Risco
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa