RESUMO
OBJECTIVES: Healthcare evolution requires optimisation of surgical training to provide safe patient care. Operating room performance after completion of proficiency based training in vascular surgery has not been investigated. DESIGN: A randomised controlled trial evaluated the impact of a Proficiency based Stepwise Endovascular Curricular Training program (PROSPECT) on the acquisition of endovascular skills and the transferability of these skills to real life interventions. MATERIALS: All subjects performed two endovascular interventions treating patients with symptomatic iliac and/or superficial femoral artery stenosis under supervision. Primary outcomes were technical performances (Global Rating Scale [GRS]; Examiner Checklist), operative metrics, and patient outcomes, adjusted for case difficulty and trainee experience. Secondary outcomes included knowledge and technical performance after 6 weeks and 3 months. METHODS: Thirty-two general surgical trainees were randomised into three groups. Besides traditional training, the first group (n = 11) received e-learning and simulation training (PROSPECT), the second group (n = 10) only had access to e-learning, while controls (n = 11) did not receive supplementary training. RESULTS: Twenty-nine trainees (3 dropouts) performed 58 procedures. Trainees who completed PROSPECT showed superior technical performance (GRS 39.36 ± 2.05; Checklist 63.51 ± 3.18) in real life with significantly fewer supervisor takeovers compared with trainees receiving e-learning alone (GRS 28.42 ± 2.15; p = .001; Checklist 53.63 ± 3.34; p = .027) or traditional education (GRS 23.09 ± 2.18; p = .001; Checklist 38.72 ± 3.38; p = .001). Supervisors felt more confident in allowing PROSPECT trained physicians to perform basic (p = .006) and complex (p = .003) procedures. No differences were detected in procedural parameters (such as fluoroscopy time, DAP, procedure time, etc.) or complications. Proficiency levels were maintained up to 3 months. CONCLUSIONS: A structured, stepwise, proficiency based endovascular curriculum including e-learning and simulation based training should be integrated early into training programs to enhance trainee performance.
Assuntos
Arteriopatias Oclusivas/cirurgia , Competência Clínica , Instrução por Computador , Educação de Pós-Graduação em Medicina/métodos , Procedimentos Endovasculares/educação , Artéria Femoral/cirurgia , Treinamento com Simulação de Alta Fidelidade , Artéria Ilíaca/cirurgia , Cirurgiões/educação , Lista de Checagem , Constrição Patológica , Currículo , Procedimentos Endovasculares/efeitos adversos , Humanos , Curva de Aprendizado , Duração da Cirurgia , Complicações Pós-Operatórias/etiologia , Método Simples-Cego , Análise e Desempenho de Tarefas , Fatores de Tempo , Resultado do TratamentoRESUMO
OBJECTIVE: Patient specific rehearsal (PsR) prior to endovascular aneurysm repair (EVAR) enables the endovascular team to practice and evaluate the procedure prior to treating the real patient. This multicentre trial aimed to evaluate the utility of PsR prior to EVAR as a pre-operative planning and briefing tool. MATERIAL AND METHODS: Patients with an aneurysm suitable for EVAR were randomised to pre-operative or post-operative PsR. Before and after the PsR, the lead implanter completed a questionnaire to identify any deviation from the initial treatment plan. All team members completed a questionnaire evaluating realism, technical issues, and human factor aspects pertinent to PsR. Technical and human factor skills, and technical and clinical success rates were compared between the randomised groups. RESULTS: 100 patients were enrolled between September 2012 and June 2014. The plan to visualise proximal and distal landing zones was adapted in 27/50 (54%) and 38/50 (76%) cases, respectively. The choice of the main body, contralateral limb, or iliac extensions was adjusted in 8/50 (16%), 17/50 (34%), and 14/50 (28%) cases, respectively. At least one of the abovementioned parameters was changed in 44/50 (88%) cases. For 100 EVAR cases, 199 subjective questionnaires post-PsR were completed. PsR was considered to be useful for selecting the optimal C-arm angulation (median 4, IQR 4-5) and was recognised as a helpful tool for team preparation (median 4, IQR 4-4), to improve communication (median 4, IQR 3-4), and encourage confidence (median 4, IQR 3-4). Technical and human factor skills and technical and initial clinical success rates were similar between the randomisation groups. CONCLUSION: PsR prior to EVAR has a significant impact on the treatment plan and may be useful as a pre-operative planning and briefing tool. Subjective ratings indicate that this technology may facilitate planning of optimal C-arm angulation and improve non-technical skills. TRIAL REGISTRATION: URL://www.clinicaltrials.gov. Unique identifier: NCT01632631.
Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/métodos , Procedimentos Endovasculares/métodos , Treinamento com Simulação de Alta Fidelidade , Modelagem Computacional Específica para o Paciente , Cirurgia Assistida por Computador/métodos , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aortografia/métodos , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Competência Clínica , Angiografia por Tomografia Computadorizada , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Humanos , Países Baixos , Equipe de Assistência ao Paciente , Segurança do Paciente , Estudos Prospectivos , Desenho de Prótese , Fatores de Risco , Stents , Cirurgia Assistida por Computador/efeitos adversos , Cirurgia Assistida por Computador/instrumentação , Inquéritos e Questionários , Fatores de Tempo , Resultado do TratamentoRESUMO
BACKGROUND: Internet and software-based platforms (e-learning) have gained popularity as teaching tools in medical education. Despite widespread use, there is limited evidence to support their effectiveness for surgical training. This study sought to evaluate the effectiveness of e-learning as a teaching tool compared with no intervention and other methods of surgical training. METHODS: A systematic literature search of bibliographical databases was performed up to August 2015. Studies were included if they were RCTs assessing the effectiveness of an e-learning platform for teaching any surgical skill, compared with no intervention or another method of training. RESULTS: From 4704 studies screened, 87 were included with 7871 participants enrolled, comprising medical students (52 studies), trainees (51 studies), qualified surgeons (2 studies) and nurses (6 studies). E-learning tools were used for teaching cognitive (71 studies), psychomotor (36 studies) and non-technical (8 studies) skills. Tool features included multimedia (84 studies), interactive learning (60 studies), feedback (27 studies), assessment (26 studies), virtual patients (22 studies), virtual reality environment (11 studies), spaced education (7 studies), community discussions (2 studies) and gaming (2 studies). Overall, e-learning showed either greater or similar effectiveness compared with both no intervention (29 and 4 studies respectively) and non-e-learning interventions (29 and 22 studies respectively). CONCLUSION: Despite significant heterogeneity amongst platforms, e-learning is at least as effective as other methods of training.
Assuntos
Educação a Distância/métodos , Educação Médica/métodos , Cirurgia Geral/educação , Internet , Competência Clínica/normas , Humanos , Ensaios Clínicos Controlados Aleatórios como Assunto , Projetos de Pesquisa , EnsinoRESUMO
BACKGROUND: Vascular surgical care has changed dramatically in recent years with little knowledge of the impact of system failures on patient safety. The primary aim of this multicentre observational study was to define the landscape of surgical system failures, errors and inefficiency (collectively termed failures) in aortic surgery. Secondary aims were to investigate determinants of these failures and their relationship with patient outcomes. METHODS: Twenty vascular teams at ten English hospitals trained in structured self-reporting of intraoperative failures (phase I). Failures occurring in open and endovascular aortic procedures were reported in phase II. Failure details (category, delay, consequence), demographic information (patient, procedure, team experience) and outcomes were reported. RESULTS: There were strong correlations between the trainer and teams for the number and type of failures recorded during 88 procedures in phase I. In 185 aortic procedures, teams reported a median of 3 (i.q.r. 2-6) failures per procedure. Most frequent failures related to equipment (unavailability, failure, configuration, desterilization). Most major failures related to communication. Fourteen failures directly harmed 12 patients. Significant predictors of an increased failure rate were: endovascular compared with open repair (incidence rate ratio (IRR) for open repair 0·71, 95 per cent c.i. 0·57 to 0·88; P = 0·002), thoracic aneurysms compared with other aortic pathologies (IRR 2·07, 1·39 to 3·08; P < 0·001) and unfamiliarity with equipment (IRR 1·52, 1·20 to 1·91; P < 0·001). The major failure total was associated with reoperation (P = 0·011), major complications (P = 0·029) and death (P = 0·027). CONCLUSION: Failure in aortic procedures is frequently caused by issues with team-working and equipment, and is associated with patient harm. Multidisciplinary team training, effective use of technology and new-device accreditation may improve patient outcomes.
Assuntos
Doenças da Aorta/cirurgia , Procedimentos Cirúrgicos Vasculares/normas , Adulto , Idoso , Idoso de 80 Anos ou mais , Competência Clínica/normas , Inglaterra , Falha de Equipamento/estatística & dados numéricos , Feminino , Humanos , Complicações Intraoperatórias/etiologia , Masculino , Erros Médicos/estatística & dados numéricos , Pessoa de Meia-Idade , Duração da Cirurgia , Medidas de Resultados Relatados pelo Paciente , Instrumentos Cirúrgicos/provisão & distribuição , Falha de TratamentoRESUMO
OBJECTIVES: The aim of this study was to establish a consensus on Fundamental Endovascular Skills (FES) for educational purposes and development of training curricula for endovascular procedures. The term "Fundamental Endovascular Skills" is widely used; however, the current literature does not explicitly describe what skills are included in this concept. Endovascular interventions are performed by several specialties that may have opposing perspectives on these skills. METHODS: A two round Delphi questionnaire approach was used. Experts from interventional cardiology, interventional radiology, and vascular surgery from the United States and Europe were invited to participate. An electronic questionnaire was generated by endovascular therapists with an appropriate educational background but who would not participate in subsequent rounds. The questionnaire consisted of 50 statements describing knowledge, technical, and behavioral skills during endovascular procedures. Experts received the questionnaires by email. They were asked to rate the importance of each skill on a Likert scale from 1 to 5. A statement was considered fundamental when more than 90% of the experts rated it 4 or 5 out of 5. RESULTS: Twenty-three of 53 experts invited agreed to participate: six interventional radiologists (2 USA, 4 Europe), 10 vascular surgeons (4 USA, 6 Europe), and seven interventional cardiologists (4 USA, 3 Europe). There was a 100% response rate in the first round and 87% in the second round. Results showed excellent consensus among responders (Cronbach's alpha = .95 first round; .93 second round). Ninety percent of all proposed skills were considered fundamental. The most critical skills were determined. CONCLUSIONS: A transatlantic multispecialty consensus was achieved about the content of "FES" among interventional radiologists, interventional cardiologists, and vascular surgeons from Europe and the United States. These results can serve as directive principles for developing endovascular training curricula.
Assuntos
Competência Clínica , Comportamento Cooperativo , Técnica Delphi , Educação de Pós-Graduação em Medicina/métodos , Procedimentos Endovasculares/educação , Cooperação Internacional , Cognição , Consenso , Currículo , Correio Eletrônico , Europa (Continente) , Humanos , Destreza Motora , Inquéritos e Questionários , Estados UnidosRESUMO
OBJECTIVE/BACKGROUND: To modify, content validate, and evaluate a teamwork assessment tool for use in endovascular surgery. METHODS: A multistage, multimethod study was conducted. Stage 1 included expert review and modification of the existing Observational Teamwork Assessment for Surgery (OTAS) tool. Stage 2 included identification of additional exemplar behaviours contributing to effective teamwork and enhanced patient safety in endovascular surgery (using real-time observation, focus groups, and semistructured interviews of multidisciplinary teams). Stage 3 included content validation of exemplar behaviours using expert consensus according to established psychometric recommendations and evaluation of structure, content, feasibility, and usability of the Endovascular Observational Teamwork Assessment Tool (Endo-OTAS) by an expert multidisciplinary panel. Stage 4 included final team expert review of exemplars. RESULTS: OTAS core team behaviours were maintained (communication, coordination, cooperation, leadership team monitoring). Of the 114 OTAS behavioural exemplars, 19 were modified, four removed, and 39 additional endovascular-specific behaviours identified. Content validation of these 153 exemplar behaviours showed that 113/153 (73.9%) reached the predetermined Item-Content Validity Index rating for teamwork and/or patient safety. After expert team review, 140/153 (91.5%) exemplars were deemed to warrant inclusion in the tool. More than 90% of the expert panel agreed that Endo-OTAS is an appropriate teamwork assessment tool with observable behaviours. Some concerns were noted about the time required to conduct observations and provide performance feedback. CONCLUSION: Endo-OTAS is a novel teamwork assessment tool, with evidence for content validity and relevance to endovascular teams. Endo-OTAS enables systematic objective assessment of the quality of team performance during endovascular procedures.
Assuntos
Procedimentos Endovasculares/normas , Equipe de Assistência ao Paciente/normas , Comunicação , Comportamento Cooperativo , Humanos , Segurança do Paciente/normas , Garantia da Qualidade dos Cuidados de Saúde/métodos , Reprodutibilidade dos TestesRESUMO
OBJECTIVES: Accurate assessment and credentialing of physicians is essential. Objective motion analysis of guide-wire/catheter manipulation to assess proficiency during endovascular interventions remains unexplored. This study aims to assess its feasibility and its role in evaluation of technical ability. MATERIALS AND METHODS: A semi-automated catheter-tracking software was developed which allows for frame-by-frame motion analysis of fluoroscopic videos and calculation 2D catheter tip path-length. 21 interventionalists (6 cardiologists, 8 interventional radiologists, 7 vascular surgeons; 14/21 had performed >500 endovascular procedures) performed an identical carotid artery stenting procedure (CAS) on a VIST simulator (Mentice, Gothenburg, Sweden). Operators were sub-divided into four categories according to CAS experience: 6 inexperienced (0 CAS-group A), 3 low-volume (1-20 CAS-group B), 5 moderate-volume (21-50 CAS-group C) and 7 high-volume (>50 CAS-group D) CAS experience. Total PL was calculated for each case and comparisons made between groups. PL was correlated with: quantitative, simulator-derived metrics and qualitative performance scores (generic and procedure-specific) derived from post-hoc video analysis by three blinded observers. RESULTS: Group D used 5160.3 (inter-quartile range- IQR 4046.4-7142.9) pixels of movement, compared to 6856.7 (5914.4-8106.9) for group A (p = 0.046); 10,905.1 (7851.1-14,381.5) for group B (p = 0.017); and 9482.6 (8663.5-13,847.6) for group C (p = 0.003). Statistically significant inverse correlations were seen between total PL and qualitative performance scores (rho = -0.519 for generic (p = 0.027) rho = -0.567 for procedure-specific (p = 0.014) scores). PL did not correlate with any of the simulator-derived metrics (errors, contrast volume, total procedure and fluoroscopy times, cine-loops used). CONCLUSION: Endovascular instrument video motion analysis is feasible and may represent a valuable tool for the objective assessment of endovascular skill.
Assuntos
Competência Clínica , Procedimentos Endovasculares/educação , Gravação de Videoteipe , Estudos de Viabilidade , Humanos , Projetos PilotoRESUMO
OBJECTIVES: This study aims to evaluate feasibility, face validity, influence on technical factors and subjective sense of utility of patient-specific rehearsal (PsR) prior to endovascular aortic aneurysm repair (EVAR). DESIGN: A prospective, multicentre pilot study. METHODS: Patients suitable for EVAR were enrolled and a three-dimensional (3D) model of the patient's anatomy was generated. Less than 24 h prior to the real case, rehearsals were conducted in the laboratory or clinical angiosuite. Technical metrics were recorded during both procedures. A subjective questionnaire was used to evaluate realism, technical and human factor aspects (scale 1-5). RESULTS: Ten patients were enrolled. In one case, the treatment plan was altered based on PsR. In 7/9 patients, the rehearsal significantly altered the optimal C-arm position for the proximal landing zone and an identical fluoroscopy angle was chosen in the real procedure. All team members found the rehearsal useful for selecting the optimal fluoroscopy angle (median 4). The realism of the EVAR procedure simulation was rated highly (median 4). All team members found the PsR useful to prepare the individual team members and the entire team (median 4). CONCLUSIONS: PsR for EVAR permits creation of realistic case studies. Subjective evaluation indicates that it may influence optimal C-arm angles and be valuable to prepare the entire team. A randomised controlled trial (RCT) is planned to evaluate how this technology may influence technical and team performance, ultimately leading to improved patient safety.
Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/métodos , Procedimentos Endovasculares/métodos , Cirurgia Assistida por Computador , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aortografia/métodos , Implante de Prótese Vascular/efeitos adversos , Competência Clínica , Simulação por Computador , Procedimentos Endovasculares/efeitos adversos , Europa (Continente) , Estudos de Viabilidade , Feminino , Humanos , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Modelos Cardiovasculares , Destreza Motora , Segurança do Paciente , Projetos Piloto , Estudos Prospectivos , Interpretação de Imagem Radiográfica Assistida por Computador , Índice de Gravidade de Doença , Cirurgia Assistida por Computador/efeitos adversos , Inquéritos e Questionários , Tomografia Computadorizada por Raios X , Resultado do TratamentoRESUMO
BACKGROUND: Recent advances in simulation science permit patient-specific rehearsal of endovascular stenting procedures. This study aimed to evaluate how effectively real interventions are replicated by patient-specific rehearsal technology, and to assess its value as a preparatory tool for the interventionalist and the operating team. METHODS: All patients deemed candidates for carotid artery stenting procedures with suitable computed tomography images were enrolled. Each team member rehearsed the virtual procedure in the laboratory, simulated operating theatre or angiography suite environment immediately before treating the real patient. Dexterity and qualitative metrics were recorded. Subjective questionnaires used a Likert scale from 1 (poor) to 5 (excellent). RESULTS: Of 18 patients, three were excluded. In 11 of 15 and 13 of 15 patients respectively endovascular tool use and fluoroscopy angles were identical during rehearsal and the real procedure. In a third of patients, the simulator did not adequately predict difficulties in cannulating the stenotic internal or common carotid arteries. The procedure realism, value in evaluating the case, increase in efficiency in tool use, and potential to increase communication, confidence and team performance were all rated highly (4 of 5). CONCLUSION: Patient-specific rehearsal was rated highly for both face and content validity. Access strategy, endovascular material use and angiographic imaging were all replicated effectively, although certain biomechanical vessel properties seemed to be replicated to a lesser degree. Patient-specific rehearsal constitutes a unique tool that may help tailor endovascular material choice, and optimize the preoperative preparation of the interventionalist and team.
Assuntos
Artéria Carótida Primitiva/cirurgia , Estenose das Carótidas/cirurgia , Simulação por Computador , Participação do Paciente , Stents , Interface Usuário-Computador , Idoso , Idoso de 80 Anos ou mais , Competência Clínica/normas , Procedimentos Endovasculares , Feminino , Humanos , Relações Interprofissionais , Masculino , Pessoa de Meia-Idade , Planejamento de Assistência ao Paciente , Equipe de Assistência ao Paciente/normas , Prática Psicológica , Desempenho Psicomotor , Inquéritos e QuestionáriosRESUMO
OBJECTIVE: The ability to perform patient-specific simulated rehearsal of complex endovascular interventions is a technological advance with potential benefits to patient outcomes. This study aimed to evaluate whether patient-specific rehearsal of a carotid artery stenting (CAS) procedure has an influence on tool selection and the use of fluoroscopy. METHODS: Following case note and computed tomography (CT) angiographic review of a real patient case, subjects performed the CAS procedure on a virtual reality simulator. Endovascular tool requirements and fluoroscopic angles were evaluated with a pre- and post-case questionnaire. Participants also rated the simulation from 1 (poor) to 5 (excellent). RESULTS: Thirty-three endovascular physicians with varying degrees of CAS experience were recruited: inexperienced (5-20 CAS procedures) n = 11, moderately (21-50 CAS procedures) n = 7 or highly experienced (>50 CAS procedures) n = 15. For all participants, 96 of a possible 363 changes (26%) were observed from pre- to post-case questionnaires. This was most notable for optimal fluoroscopy C-arm position 15/33 (46%), choice of selective catheter 13/33 (39%), choice of sheath or guiding catheter 11/33 (33%) and balloon dilatation strategy 10/33 (30%). Experience with the CAS procedure did not influence the degree of change significantly (p > 0.05), and all groups exhibited a considerable modification in tool and fluoroscopy preference. The model was considered realistic and useful as a tool to practice a real case (median score 4/5). CONCLUSION: Patient-specific simulated rehearsal of a complex endovascular procedure strongly influences tool selection and fluoroscopy preferences for the real case. Further research has to evaluate how this technology may transfer from in vitro to in vivo and if it can reduce the radiation dose and the number of endovascular tools used and improve outcomes for patients in the clinical setting.
Assuntos
Angioplastia com Balão/instrumentação , Estenose das Carótidas/terapia , Competência Clínica , Simulação por Computador , Modelos Cardiovasculares , Radiografia Intervencionista , Stents , Terapia Assistida por Computador , Adulto , Idoso , Estenose das Carótidas/diagnóstico por imagem , Catéteres , Desenho de Equipamento , Fluoroscopia , Humanos , Imageamento Tridimensional , Masculino , Prontuários Médicos , Pessoa de Meia-Idade , Interpretação de Imagem Radiográfica Assistida por Computador , Radiografia Intervencionista/instrumentação , Índice de Gravidade de Doença , Inquéritos e Questionários , Análise e Desempenho de Tarefas , Tomografia Computadorizada por Raios X , Interface Usuário-ComputadorRESUMO
Reduced training times, increasing complexity of endovascular and open vascular interventions and concerns for patient's safety have necessitated a modernisation in surgical training. A more strategic approach is required to facilitate the acquisition of surgical skills outside the operating room and to minimize the risks to patients as surgeons develop their technical expertise. Virtual reality simulation has been proposed as a means to train and objectively assess technical endovascular performance without risks to patient safety. This article reviews the evidence and the limitations for this adjunctive tool, the implementation in current training programmes and future applications to maintain the highest standards of care for treatment of vascular disease.
Assuntos
Simulação por Computador , Instrução por Computador , Educação de Pós-Graduação em Medicina/métodos , Procedimentos Endovasculares/educação , Internato e Residência , Salas Cirúrgicas , Procedimentos Cirúrgicos Vasculares/educação , Competência Clínica , Gráficos por Computador , Currículo , Humanos , Modelos Cardiovasculares , Modelos EducacionaisRESUMO
BACKGROUND: Mobile thoracic or abdominal aortic thrombi are a potential source of embolism to visceral organs or lower limbs. Detection levels of this type of aortic pathology after any embolic event have increased considerably. Nevertheless, therapeutic management of an intraluminal mobile thrombus of the aorta remains controversial. The aim of this study is to describe the treatment modalities for symptomatic mural aortic thrombi based on three cases diagnosed at our institution and to review the literature. METHODS: During the last decade, several patients with peripheral embolisation were diagnosed with an intraluminal mobile aortic thrombus. Three patients who were treated differently were selected and reviewed. In addition a literature search was performed on PubMed and Medline from their inception to the present for all English language articles using the following keywords: blue toe syndrome, peripheral arterial embolisation, mobile thrombus and aorta. The advantages and drawbacks of medical management, open and endovascular treatment are described. RESULTS: Three particular patients with embolisation due to a floating aortic thrombus were reviewed. The first patient underwent a thoracotomy with replacement of the descending thoracic aorta. Another case was treated successfully by implanting an endovascular stent graft in the descending thoracic aorta. The last patient was treated medically because of the involvement of the visceral vessels. When reviewing the literature, no randomised controlled trials were found but several case reports have described both open and endovascular techniques. No long-term follow up of this rare pathology is available. CONCLUSIONS: In the literature there is no consensus how to treat a symptomatic floating aortic thrombus. This report shows that therapeutic strategies are influenced by the localisation of the thrombus, the co-morbidities of the patient and the physician' s preferences. Endovascular treatment in combination with high dose statins has become the preferred treatment method although long-term data are lacking.
Assuntos
Doenças da Aorta/terapia , Embolia/terapia , Trombose/terapia , Anticoagulantes/uso terapêutico , Aorta Torácica/cirurgia , Doenças da Aorta/complicações , Implante de Prótese Vascular , Embolia/etiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Inibidores da Agregação Plaquetária/uso terapêutico , Stents , Toracotomia , Trombose/complicaçõesRESUMO
OBJECTIVES: To develop weighted error-based, generic and procedure-specific rating scales, to validate these scales for video-based assessment during virtual carotid artery stent (CAS) procedures and correlate them with simulator-derived metrics. METHODS: A questionnaire was developed to assess the technique during live CAS procedures. Errors were rated from 1 (unimportant) to 5 (life-threatening) by 28 highly experienced CAS (>50 CAS) physicians. Virtual CAS procedure was performed by 21 interventionalists with varied CAS experience. Fluoroscopy screen and hand movements were video-taped, and simulator-derived metrics recorded. Experienced CAS practitioners then rated the video-taped performances using weighted error, generic and procedure-specific rating scales. RESULTS: Of the 23 errors assessed, 12 were regarded as moderate (score 3), six serious (score 4) and four life-threatening (score 5). The generic rating scale was able to detect significant differences in performance between inexperienced and experienced CAS operators (score 25 vs. 32 respectively, P<0.01). All scoring systems demonstrated good inter-rater reliability (alpha=0.61-0.87). Significant correlations were observed between simulator-derived and video-based scores: weighted error-based score (r: 0.76, P<0.01), generic (r: 0.62, P<0.01) and procedure-specific (r: 0.76, P<0.01) rating scales. CONCLUSIONS: The generic endovascular rating scale differentiated between levels of CAS experience among skilled interventionalists and correlated to simulator-based error scoring.
Assuntos
Implante de Prótese Vascular/normas , Estenose das Carótidas/cirurgia , Competência Clínica/normas , Erros Médicos/prevenção & controle , Avaliação de Resultados em Cuidados de Saúde/métodos , Stents , Gravação em Vídeo/métodos , Humanos , Erros Médicos/estatística & dados numéricos , Inquéritos e Questionários , Interface Usuário-ComputadorRESUMO
OBJECTIVE: Carotid artery stenting (CAS) is an advanced endovascular intervention with a steep learning curve. Virtual reality (VR) simulation has been proposed as a means to train and objectively assess technical performance. AIM: To objectively assess psychomotor skills acquisition of experienced interventionalists attending a two-day CAS course, using a VR simulator. METHODS: Both cognitive and technical skills of 11 interventionalists were trained in a two-day course using didactic sessions, case reviews, supervised VR simulation and live-cases. Pre- and post-course skills were assessed through performance on the same CAS procedure using metrics derived from the simulator. RESULTS: Significant differences were noted between pre- and post-course performance for procedure (36 vs. 20min., p=0.005), X-ray (20 vs. 11min., p=0.016) and delivery-retrieval time of the embolic protection device (12 vs. 9min., p=0.007). Advancement of the guiding catheter without a leading wire occurred to a greater extent pre- versus post-course (199 vs. 152mm., p=0.050) as did spasm of the internal carotid artery (4 vs. 2, p=0.049). CONCLUSIONS: This study has objectively proven a benefit for experienced interventionalists to attend CAS courses for skills acquisition measured by a VR simulator. These data can be used to offer participants an insight into their skills and objectively audit course efficacy.
Assuntos
Angioplastia com Balão/educação , Estenose das Carótidas/terapia , Desempenho Psicomotor , Stents , Competência Clínica , Simulação por Computador , Currículo , Educação Médica Continuada , Avaliação Educacional , Humanos , Modelos Cardiovasculares , Interface Usuário-ComputadorRESUMO
OBJECTIVES: Post-operative haemorrhage is a recognised complication and independent predictor of outcome in complex vascular surgery. The off-license administration of activated Recombinant Factor VII (rFVIIa) to treat haemorrhage in other surgical settings has been investigated, but concerns over potential adverse events have limited its use in vascular surgery. This article reports rFVIIa's method of action and systematically reviews rFVIIa's role in complex vascular surgery. METHODS: A systematic literature search identified articles reporting on rFVIIa administration within vascular surgery patients. Patient-specific data regarding transfusion requirements was extracted and pooled statistical analysis performed. RESULTS: 15 articles reporting 43 patients were identified. RFVIIa has been administered in open and endovascular procedures and in both elective and emergency settings. Major aortic surgery accounted for 75% of cases. The range of rFVIIa administered as a cumulative dose was large, as was the variation in initial dose. Transfusion data from 9 patients was pooled and analysed. Significant differences were found between pre- and post- rFVIIa for packed red cell transfusions (mean 29.2 vs. 8.2, p=0.015). Intra-arterial thrombosis was reported in 3 cases. CONCLUSIONS: RFVIIa may reduce haemorrhage in selected vascular surgical patients. Randomized controlled trials are justified to definitively investigate its role within this setting.
Assuntos
Coagulantes/uso terapêutico , Fator VIIa/uso terapêutico , Hemorragia Pós-Operatória/prevenção & controle , Procedimentos Cirúrgicos Vasculares/efeitos adversos , Adulto , Idoso , Idoso de 80 Anos ou mais , Coagulantes/administração & dosagem , Coagulantes/efeitos adversos , Esquema de Medicação , Transfusão de Eritrócitos , Fator VIIa/administração & dosagem , Fator VIIa/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Hemorragia Pós-Operatória/etiologia , Hemorragia Pós-Operatória/mortalidade , Proteínas Recombinantes/administração & dosagem , Proteínas Recombinantes/efeitos adversos , Proteínas Recombinantes/uso terapêutico , Projetos de Pesquisa , Trombose/induzido quimicamente , Resultado do TratamentoRESUMO
AIM: The aim of this study was to describe the results and long-term follow-up of the Vanguard endovascular graft for infrarenal abdominal aortic aneurysm (AAA) repair. METHODS: Between February 1997 and October 1999, 76 patients were treated with a median aneurysm diameter of 52 mm (39-90 mm). All were followed up according to the Eurostar criteria. RESULTS: The primary technical success rate was 100%. Perioperative mortality was 1.3%. During follow-up (median 75 months, 6-112 months) 9 aneurysm related deaths occurred. A total of 79 late complications occurred in 45 patients (64%). Complications were noticed more frequently in the group of aneurysms larger than 5.5 cm (P=0.014). Patients who ultimately developed aneurysm rupture after endovascular repair had more postoperative complications compared to the majority who did not rupture their aneurysm. (P=0.001) Secondary interventions were mandatory in 23 patients, surgical conversion in 9. At 72 months this has resulted in an overall survival rate of 57%, an aneurysm rupture free survival of 88%, a conversion free survival of 95%, an endoleak free survival of 83% and a secondary intervention free survival of 82% (Kaplan Maier). CONCLUSION: The importance of life-long strict surveillance of patients treated with a Vanguard endograft was confirmed. Patients with graft-related complications should be treated accordingly.
Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Ruptura Aórtica/etiologia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Falha de Prótese , Stents , Idoso , Aneurisma da Aorta Abdominal/complicações , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/mortalidade , Ruptura Aórtica/diagnóstico por imagem , Ruptura Aórtica/mortalidade , Ruptura Aórtica/cirurgia , Aortografia , Bélgica , Implante de Prótese Vascular/efeitos adversos , Feminino , Seguimentos , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Reoperação , Estudos Retrospectivos , Fatores de Tempo , Tomografia Computadorizada por Raios XRESUMO
Ruptured abdominal aortic aneurysms are almost always a fatal condition. The incidence of ruptured aortic aneurysms (rAAA) is declining, the number of teams is increasing and there is an increased focus on patient safety resulting in limited real life training opportunities to maintain or improve the technical and human factor skills required to manage this acute aortic pathology. The availability and experience of the multidisciplinary team together with accessibility of appropriate resuscitation and efficient logistics all influence the modality of rAAA repair. A standardised patient's pathway for rAAA management and reliable multidisciplinary team are the keys to improve patient outcomes. Whole rEVAR team training using high fidelity simulation may be the one answer to allow clinicians to learn, practice, rehearse, improve and maintain team-based knowledge, technical and human factor skills and team attitudes to manage this challenging pathology.
Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Ruptura Aórtica/cirurgia , Implante de Prótese Vascular/educação , Educação Médica Continuada , Educação de Pós-Graduação em Medicina , Procedimentos Endovasculares/educação , Equipe de Assistência ao Paciente , Aneurisma da Aorta Abdominal/mortalidade , Ruptura Aórtica/mortalidade , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Competência Clínica , Simulação por Computador , Instrução por Computador , Comportamento Cooperativo , Educação Médica Continuada/métodos , Educação de Pós-Graduação em Medicina/métodos , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Humanos , Comunicação Interdisciplinar , Resultado do TratamentoRESUMO
The BRAVISSIMO study is a prospective, non-randomized, multi-center, multi-national, monitored trial, conducted at 12 hospitals in Belgium and 11 hospitals in Italy. This manuscript reports the findings up to the 12-month follow-up time point for both the TASC A&B cohort and the TASC C&D cohort. The primary endpoint of the study is primary patency at 12 months, defined as a target lesion without a hemodynamically significant stenosis on Duplex ultrasound (>50%, systolic velocity ratio no greater than 2.0) and without target lesion revascularization (TLR) within 12 months. Between July 2009 and September 2010, 190 patients with TASC A or TASC B aortoiliac lesions and 135 patients with TASC C or TASC D aortoiliac lesions were included. The demographic data were comparable for the TASC A/B cohort and the TASC C/D cohort. The number of claudicants was significantly higher in the TASC A/B cohort, The TASC C/D cohort contains more CLI patients. The primary patency rate for the total patient population was 93.1%. The primary patency rates at 12 months for the TASC A, B, C and D lesions were 94.0%, 96.5%, 91.3% and 90.2% respectively. No statistical significant difference was shown when comparing these groups. Our findings confirm that endovascular therapy, and more specifically primary stenting, is the preferred treatment for patients with TASC A, B, C and D aortoiliac lesions. We notice similar endovascular results compared to surgery, however without the invasive character of surgery.
Assuntos
Artéria Ilíaca , Doença Arterial Periférica/terapia , Stents , Adulto , Idoso , Idoso de 80 Anos ou mais , Ligas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Doença Arterial Periférica/patologia , RecidivaRESUMO
Despite many randomised controlled trials there are none that recommend carotid artery stenting (CAS) replaces carotid endarterectomy (CEA) for preventing stroke in patients with atherosclerotic carotid artery stenosis. CAS continues to be attractive due to its minimally-invasive nature and potential benefit in those patients at 'high risk' during open surgery. The belief that CAS will replace CEA is likely misplaced; a complimentary role for each mode of treatment is a more realistic vision for the future. Assessment of the existing data may provide useful information as to the subgroups that have most to benefit from each treatment type, therefore allowing a patient-specific approach to the management of individual lesions. This knowledge, coupled with further advances in the techniques of open and endovascular surgery, will progress the application of CAS and better its results.
Assuntos
Angioplastia/instrumentação , Doenças das Artérias Carótidas/terapia , Endarterectomia das Carótidas , Stents , Angioplastia/efeitos adversos , Doenças das Artérias Carótidas/cirurgia , Endarterectomia das Carótidas/efeitos adversos , Medicina Baseada em Evidências , Humanos , Seleção de Pacientes , Desenho de Prótese , Ensaios Clínicos Controlados Aleatórios como Assunto , Sistema de Registros , Medição de Risco , Fatores de Risco , Resultado do TratamentoRESUMO
INTRODUCTION: There is a learning curve in the acquisition of endovascular skills for the treatment of vascular disease. Integration of Virtual reality (VR) simulator based training into the educational training curriculum offers a potential solution to overcome this learning curve. However evidence-based training curricula that define which tasks, how often and in which order they should be performed have yet to be developed. The aim of this study was to determine the nature of skills acquisition on the renal and iliac modules of a commercially-available VR simulator. METHOD: 20 surgical trainees without endovascular experience were randomised to complete eight sessions on a VR iliac (group A) or renal (group B) training module. To determine skills transferability across the two procedures, all subjects performed two further VR cases of the other procedure. Performance was recorded by the simulator for parameters such as time taken, contrast fluid usage and stent placement accuracy. RESULTS: During training, both groups demonstrated statistically significant VR learning curves: group A for procedure time (p<0.001) and stent placement accuracy (p=0.013) group B for procedure time (p<0.001), fluoroscopy time (p=0.003) and volume of contrast fluid used (p<0.001). At crossover, subjects in group B (renal trained) performed to the same level of skill on the simulated iliac task as group A. However, those in group A (iliac trained) had a significantly higher fluoroscopy time (median 118 vs 72 secs, p=0.020) when performing their first simulated renal task than for group B. CONCLUSION: Novice endovascular surgeons can significantly improve their performance of simulated procedures through repeated practice on VR simulators. Skills transfer between tasks was demonstrated but complex task training, such as selective arterial cannulation in simulators and possibly in the real world appears to involve a separate skill. It is thus suggested that a stepwise and hierarchical training curriculum is developed for acquisition of endovascular skill using VR simulation to supplement training on patients.