Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
País como assunto
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Biol Blood Marrow Transplant ; 26(10): 1784-1802, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32653624

RESUMO

Bone health disturbances commonly occur after hematopoietic cell transplantation (HCT) with loss of bone mineral density (BMD) and avascular necrosis (AVN) foremost among them. BMD loss is related to pretransplantation chemotherapy and radiation exposure and immunosuppressive therapy for graft-versus-host-disease (GVHD) and results from deficiencies in growth or gonadal hormones, disturbances in calcium and vitamin D homeostasis, as well as osteoblast and osteoclast dysfunction. Although the pathophysiology of AVN remains unclear, high-dose glucocorticoid exposure is the most frequent association. Various societal treatment guidelines for osteoporosis exist, but the focus is mainly on menopausal-associated osteoporosis. HCT survivors comprise a distinct population with unique comorbidities, making general approaches to bone health management inappropriate in some cases. To address a core set of 16 frequently asked questions (FAQs) relevant to bone health in HCT, the American Society of Transplant and Cellular Therapy Committee on Practice Guidelines convened a panel of experts in HCT, adult and pediatric endocrinology, orthopedics, and oral medicine. Owing to a lack of relevant prospective controlled clinical trials that specifically address bone health in HCT, the answers to the FAQs rely on evidence derived from retrospective HCT studies, results extrapolated from prospective studies in non-HCT settings, relevant societal guidelines, and expert panel opinion. Given the heterogenous comorbidities and needs of individual HCT recipients, answers to FAQs in this article should be considered general recommendations, with good medical practice and judgment ultimately dictating care of individual patients. Readers are referred to the Supplementary Material for answers to additional FAQs that did not make the core set.


Assuntos
Doença Enxerto-Hospedeiro , Transplante de Células-Tronco Hematopoéticas , Densidade Óssea , Transplante de Células-Tronco Hematopoéticas/efeitos adversos , Humanos , Estudos Prospectivos , Estudos Retrospectivos , Estados Unidos
2.
J Orthop Surg Res ; 14(1): 182, 2019 Jun 17.
Artigo em Inglês | MEDLINE | ID: mdl-31208448

RESUMO

BACKGROUND: Metal sensitivity as a cause for painful joint replacement has become increasingly prevalent; however, there is a lack of reported clinical outcome data from total knee arthroplasty patients with metal allergies. The purpose of this study was to determine whether patients presenting with a painful total knee arthroplasty with a positive metal sensitivity have improved outcomes following revision to a hypoallergenic implant. METHODS: A retrospective review was conducted for patients that underwent a revision total knee arthroplasty after metal sensitivity testing over a 3-year period from January 1, 2015, to December 31, 2017. Based on the results of sensitivity testing, patients underwent revision total knee arthroplasty to a hypoallergenic component or a standard component. Following revision, patients returned to the clinic at an interval of 6 weeks, 5 months, and 12 months for functional, pain, and satisfaction assessment. Outcomes were compared within and between sensitivity groups. RESULTS: Of the included patients, 78.3% (39/46) were positive for metal sensitivity. The most common metal sensitivity was to nickel (79.5%, 32/39). Both non-reactive and reactive patients significantly improved in range of motion after revision arthroplasty. The reactive group saw a 37.8% decrease in pain at 6 weeks post-revision (p < 0.001) Whereas, the non-reactive group only saw a moderate, non-significant improvement in pain reduction at 6 weeks post-revision (27.0%; p = 0.29). Frequency of pain experienced did not vary significantly between groups. Maximum metal lymphocyte transformation test (LTT) sensitivity score did not correlate with pain level at the time of revision (R2 = 0.02, p = 0.38) or percent improvement after revision (R2 = 0.001, p = 0.81). Overall, all patients reported being very satisfied after revision total knee arthroplasty; there was no difference between positive and negative sensitivity groups (W = 62, p = 0.89). CONCLUSIONS: Patients presenting with a painful knee arthroplasty and positive metal LTT have improved pain scores, walking function, and range of motion following revision to a hypoallergenic component. This study also provides a treatment algorithm for patients presenting with a painful knee replacement, in order to provide effective and timely diagnosis and management.


Assuntos
Artroplastia do Joelho/efeitos adversos , Hipersensibilidade/complicações , Prótese do Joelho/efeitos adversos , Metais/efeitos adversos , Reoperação , Artroplastia do Joelho/estatística & dados numéricos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reoperação/estatística & dados numéricos , Estudos Retrospectivos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa