1.
Perfusion ; : 2676591241249612, 2024 Jun 11.
Artigo em Inglês | MEDLINE | ID: mdl-38860785

RESUMO

As survival after ECMO improves and use of ECMO support increases in both pediatric and adult population, there is a need to focus on both the morbidities and complications associated with ECMO and how to manage and prevent them. Infectious complications during ECMO often have a significant clinical impact, resulting in increased morbidity or mortality irrespective of the underlying etiology necessitating cardiorespiratory support. In this review article, we discuss the prevention, management, challenges, and differences of infectious complications in adult and pediatric patients receiving ECMO support.

2.
Perfusion ; : 2676591241246079, 2024 Apr 06.
Artigo em Inglês | MEDLINE | ID: mdl-38581646

RESUMO

Background: Nitric Oxide (NO) is a naturally occurring modulator of inflammation found in the human body. Several studies in the pediatric cardiothoracic surgery literature have demonstrated some beneficial clinical effects when NO is added to the sweep gas of the cardiopulmonary bypass circuit.Purpose: Our primary aim was to determine the safety of incorporating nitric oxide into the oxygenator sweep gas of the extracorporeal membrane oxygenation (ECMO) circuit. Secondarily, we looked at important clinical outcomes, such as survival, blood product utilization, and common complications related to ECMO.Methods: We performed a single center, retrospective review of all patients at our institution who received ECMO between January 1, 2017 and March 31, 2023. We began additing NO to the ECMO sweep gas in 2019. Results: There were no instances of clinically significant methemoglobinemia with the addition of NO to the sweep gas (0% vs 0%, p = 1). The median daily methemoglobin level was higher in those who received NO via the sweep gas when compared to those who did not (1.6 vs 1.1, p = <0.001). Conclusions: The addition of NO to the sweep gas of the ECMO circuit is safe.

4.
Artigo em Inglês | MEDLINE | ID: mdl-38299367

RESUMO

In this video tutorial, we present neck cannulation for venovenous extracorporeal membrane oxygenation using a crescent right atrial double lumen cannula in a 4-kg baby.