Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31
Filtrar
1.
J Card Surg ; 36(9): 3271-3280, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34159641

RESUMO

BACKGROUND: There is a clinical need for additional remote tools to improve left ventricular assist device (LVAD) patient management. The aim of this pilot concept study was to assess the safety and feasibility of optimizing patient management with add-on remote hemodynamic monitoring using the CardioMEMS in LVAD patients during different treatment stages. METHODS: Ten consecutive patients accepted and clinically ready for (semi-) elective HeartMate 3 LVAD surgery were included. All patients received a CardioMEMS to optimize filling pressure before surgery. Patients were categorized into those with normal mean pulmonary artery pressure (mPAP) (≤25 mmHg, n = 4) or elevated mPAP (>25 mmHg, n = 6), and compared to a historical cohort (n = 20). Endpoints were CardioMEMS device safety and a combined endpoint of all-cause mortality, acute kidney injury, renal replacement therapy and/or right ventricular failure at 1-year follow-up. Additionally, we investigated hospital-free survival and improvement in quality of life (QoL) and exercise tolerance. RESULTS: No safety issues or signal interferences were observed. The combined endpoint occurred in 60% of historical controls, 0% in normal and 83% in elevated mPAP group. Post-discharge, the hospital-free survival was significantly better, and the QoL improved more in the normal compared to the elevated mPAP group. CONCLUSION: Remote hemodynamic monitoring in LVAD patients is safe and feasible with the CardioMEMS, which could be used to identify patients at elevated risk of complications as well as optimize patient management remotely during the out-patient phase with less frequent hospitalizations. Larger pivotal studies are warranted to test the hypothesis generated from this concept study.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Monitorização Hemodinâmica , Assistência ao Convalescente , Estudos de Viabilidade , Insuficiência Cardíaca/terapia , Hemodinâmica , Humanos , Alta do Paciente , Artéria Pulmonar , Qualidade de Vida
2.
Sensors (Basel) ; 21(3)2021 Jan 28.
Artigo em Inglês | MEDLINE | ID: mdl-33525556

RESUMO

Heart failure (HF) is a major health care issue, and the incidence of HF is only expected to grow further. Due to the frequent hospitalizations, HF places a major burden on the available hospital and healthcare resources. In the future, HF care should not only be organized solely at the clinical ward and outpatient clinics, but remote monitoring strategies are urgently needed to guide, monitor, and treat chronic HF patients remotely from their homes as well. The intuitiveness and relatively low costs of non-invasive remote monitoring tools make them an appealing and emerging concept for developing new medical apps and devices. The recent COVID-19 pandemic and the associated transition of patient care outside the hospital will boost the development of remote monitoring tools, and many strategies will be reinvented with modern tools. However, it is important to look carefully at the inconsistencies that have been reported in non-invasive remote monitoring effectiveness. With this review, we provide an up-to-date overview of the available evidence on non-invasive remote monitoring in chronic HF patients and provide future perspectives that may significantly benefit the broader group of HF patients.


Assuntos
Continuidade da Assistência ao Paciente/tendências , Insuficiência Cardíaca/terapia , Monitorização Fisiológica/métodos , Telemedicina/tendências , COVID-19 , Insuficiência Cardíaca/diagnóstico , Humanos , Pandemias , SARS-CoV-2 , Telemetria , Telenfermagem
3.
Sensors (Basel) ; 21(6)2021 Mar 12.
Artigo em Inglês | MEDLINE | ID: mdl-33809205

RESUMO

The large and growing burden of chronic heart failure (CHF) on healthcare systems and economies is mainly caused by a high hospital admission rate for acute decompensated heart failure (HF). Several remote monitoring techniques have been developed for early detection of worsening disease, potentially limiting the number of hospitalizations. Over the last years, the scope has been shifting towards the relatively novel invasive sensors capable of measuring intracardiac filling pressures, because it is believed that hemodynamic congestion precedes clinical congestion. Monitoring intracardiac pressures may therefore enable clinicians to intervene and avert hospitalizations in a pre-symptomatic phase. Several techniques have been discussed in this review, and thus far, remote monitoring of pulmonary artery pressures (PAP) by the CardioMEMS (CardioMicroelectromechanical system) HF System is the only technique with proven safety as well as efficacy with regard to the prevention of HF-related hospital admissions. Efforts are currently aimed to further develop existing techniques and new sensors capable of measuring left atrial pressures (LAP). With the growing body of evidence and need for remote care, it is expected that remote monitoring by invasive sensors will play a larger role in HF care in the near future.


Assuntos
Insuficiência Cardíaca , Doença Crônica , Insuficiência Cardíaca/diagnóstico , Humanos
4.
Sensors (Basel) ; 21(7)2021 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-33801573

RESUMO

The CardioMEMS pulmonary artery (PA) monitoring system placed in the left lower lobe pulmonary artery is capable of measuring pulmonary artery pressure remotely as a surrogate of intracardiac filling pressures and volume status. The technique is safe and reliable. By using remote PA monitoring for proactive medical interventions, there is a growing body of clinical evidence for a substantial, robust reduction in HF hospitalizations in various populations (clinical trial setting, post-marketing studies and real-world experiences). This review summarizes the clinical evidence, outlines future perspectives, and aims for remote patient care in heart failure using CardioMEMS.


Assuntos
Insuficiência Cardíaca , Monitorização Hemodinâmica , Doença Crônica , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Humanos , Artéria Pulmonar
5.
J Nucl Cardiol ; 26(3): 845-852, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-29116562

RESUMO

BACKGROUND: Myocardial perfusion imaging (MPI) using single-photon emission computed tomography (SPECT) is useful in the evaluation of cardiac allograft vasculopathy (CAV) in heart transplant (HTx) recipients. The current study evaluated the long-term prognostic value of stress SPECT MPI for predicting all-cause mortality and cardiac events in HTx recipients. METHODS: The study population consisted of 166 HTx recipients (mean age 54 ± 10 years, 84% male) who underwent exercise or dobutamine stress 99mTc-tetrofosmin SPECT MPI for the assessment of CAV. An abnormal SPECT MPI was defined as the presence of a fixed or a reversible perfusion defect. Endpoints were all-cause mortality, cardiac mortality, and non-fatal myocardial infarction (MI). RESULTS: MPI abnormalities were detected in 55 patients (33%), including fixed defects in 28 patients (17%), partially reversible in 17 patients (10%), and completely reversible defects in 10 patients (6%). During a median follow-up of 12.8 years (range 0-15, mean follow-up 9.5 years), 109 (66%) patients died (all-cause mortality), of which 67 (40%) were due to cardiac causes. A total of 5 (3%) patients experienced a non-fatal MI. HTx recipients with a normal stress 99mTc-tetrofosmin SPECT MPI had a significantly better prognosis as compared with those with an abnormal study, up to 5 years after the initial test. The presence of a reversible perfusion defect was a significant predictor of all-cause mortality, cardiac mortality, and major cardiac events, during the entire follow-up period. CONCLUSIONS: Stress 99mTc-tetrofosmin SPECT MPI provides valuable prognostic information for the prediction of long-term outcome in HTx recipients. Patients with a normal stress 99mTc-tetrofosmin SPECT MPI have a significantly better prognosis as compared with those with an abnormal study, up to 5 years after initial testing.


Assuntos
Cardiopatias/diagnóstico por imagem , Transplante de Coração , Imagem de Perfusão do Miocárdio , Compostos Organofosforados , Compostos de Organotecnécio , Compostos Radiofarmacêuticos , Tomografia Computadorizada de Emissão de Fóton Único , Adulto , Teste de Esforço , Feminino , Cardiopatias/etiologia , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Fatores de Tempo , Resultado do Tratamento
6.
J Nucl Cardiol ; 22(5): 888-900, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25537614

RESUMO

OBJECTIVE: Despite multiple studies on the diagnostic and prognostic use of dobutamine myocardial perfusion imaging (MPI), information on its long-term prognostic value is scarce. The aim of this study was to assess the value of this technique for the prediction of very long-term outcome. METHODS: A total of 721 patients with limited exercise capacity underwent dobutamine MPI for the evaluation of suspected or known coronary artery disease. 719 of 721 patients attended follow-up (99.7%). Twenty-eight patients who underwent early coronary revascularization were excluded from analysis. Endpoints were all-cause mortality, cardiac death, nonfatal infarction, and coronary revascularization. Kaplan-Meier survival curves were constructed, and univariate and multivariate analyses were performed to identify predictors of long-term outcome. RESULTS: The mean age of patients was 60 ± 11 years, and 61% were male. Myocardial perfusion abnormalities were present in 381 patients (55%) and included fixed defects in 190 patients (27%) and reversible defects in 191 patients (28%). During a median follow-up time of 14 years (range 0-16), 295 deaths occurred (43%), of which 158 were cardiac deaths (23%). Nonfatal myocardial infarction occurred in 35 (5%), and late coronary revascularization was performed on 133 patients (19%). An abnormal dobutamine MPI provided significant prognostic information for prediction of cardiac death, hard cardiac events, and MACE, after adjustment for significant clinical variables and stress test variables. CONCLUSIONS: Dobutamine MPI provides incremental prognostic information for the prediction of cardiovascular outcomes in patients with limited exercise capacity. The long-term prognosis of patients with limited exercise capacity who have an abnormal dobutamine MPI is significantly worse than those with a normal MPI.


Assuntos
Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Dobutamina/química , Imagem de Perfusão do Miocárdio/métodos , Idoso , Índice de Massa Corporal , Teste de Esforço , Feminino , Seguimentos , Coração/diagnóstico por imagem , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/diagnóstico por imagem , Revascularização Miocárdica , Miocárdio/patologia , Compostos de Organotecnécio/química , Prognóstico , Modelos de Riscos Proporcionais , Compostos Radiofarmacêuticos/química , Tecnécio/química , Tomografia Computadorizada de Emissão de Fóton Único , Resultado do Tratamento
7.
ESC Heart Fail ; 10(2): 884-894, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36460627

RESUMO

AIMS: Use of left ventricular assist devices (LVADs) in older patients has increased, and assessing outcomes in older LVAD recipients is important. Therefore, this study aimed to investigate associations between age and outcomes after continuous-flow LVAD (cf-LVAD) implantation. METHODS AND RESULTS: Cf-LVAD patients from the multicentre European PCHF-VAD registry were included and categorized into those <50, 50-64, and ≥65 years old. The primary endpoint was all-cause mortality. Among secondary outcomes were heart failure (HF) hospitalizations, right ventricular (RV) failure, haemocompatibility score, bleeding events, non-fatal thromboembolic events, and device-related infections. Of 562 patients, 184 (32.7%) were <50, 305 (54.3%) were aged 50-64, whereas 73 (13.0%) were ≥65 years old. Median follow-up was 1.1 years. Patients in the oldest age group were significantly more often designated as destination therapy (DT) candidates (61%). A 10 year increase in age was associated with a significantly higher risk of mortality (hazard ratio [HR] 1.34, 95% confidence interval [CI] [1.15-1.57]), intracranial bleeding (HR 1.49, 95% CI [1.10-2.02]), and non-intracranial bleeding (HR 1.30, 95% CI [1.09-1.56]), which was confirmed by a higher mean haemocompatibility score (1.37 vs. 0.77, oldest vs. youngest groups, respectively, P = 0.033). Older patients suffered from less device-related infections requiring systemic antibiotics. No age-related differences were observed in HF-related hospitalizations, ventricular arrhythmias, pump thrombosis, non-fatal thromboembolic events, or RV failure. CONCLUSIONS: In the PCHF-VAD registry, higher age was associated with increased risk of mortality, and especially with increased risk of major bleeding, which is particularly relevant for the DT population. The risks of HF hospitalizations, pump thrombosis, ventricular arrhythmia, or RV failure were comparable. Strikingly, older patients had less device-related infections.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Trombose , Humanos , Idoso , Coração Auxiliar/efeitos adversos , Resultado do Tratamento , Insuficiência Cardíaca/epidemiologia , Insuficiência Cardíaca/terapia , Arritmias Cardíacas , Sistema de Registros , Trombose/etiologia
8.
ESC Heart Fail ; 10(2): 1054-1065, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36547014

RESUMO

AIMS: Data on sex and left ventricular assist device (LVAD) utilization and outcomes have been conflicting and mostly confined to US studies incorporating older devices. This study aimed to investigate sex-related differences in LVAD utilization and outcomes in a contemporary European LVAD cohort. METHODS AND RESULTS: This analysis is part of the multicentre PCHF-VAD registry studying continuous-flow LVAD patients. The primary outcome was all-cause mortality. Secondary outcomes included ventricular arrhythmias, right ventricular failure, bleeding, thromboembolism, and the haemocompatibility score. Multivariable Cox regression models were used to assess associations between sex and outcomes. Overall, 457 men (81%) and 105 women (19%) were analysed. At LVAD implant, women were more often in Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) profile 1 or 2 (55% vs. 41%, P = 0.009) and more often required temporary mechanical circulatory support (39% vs. 23%, P = 0.001). Mean age was comparable (52.1 vs. 53.4 years, P = 0.33), and median follow-up duration was 344 [range 147-823] days for women and 435 [range 190-816] days for men (P = 0.40). No significant sex-related differences were found in all-cause mortality (hazard ratio [HR] 0.79 for female vs. male sex, 95% confidence interval [CI] [0.50-1.27]). Female LVAD patients had a lower risk of ventricular arrhythmias (HR 0.56, 95% CI [0.33-0.95]) but more often experienced right ventricular failure. No significant sex-related differences were found in other outcomes. CONCLUSIONS: In this contemporary European cohort of LVAD patients, far fewer women than men underwent LVAD implantation despite similar clinical outcomes. This is important as the proportion of female LVAD patients (19%) was lower than the proportion of females with advanced HF as reported in previous studies, suggesting underutilization. Also, female patients were remarkably more often in INTERMACS profile 1 or 2, suggesting later referral for LVAD therapy. Additional research in female patients is warranted.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Humanos , Masculino , Feminino , Coração Auxiliar/efeitos adversos , Resultado do Tratamento , Insuficiência Cardíaca/epidemiologia , Insuficiência Cardíaca/terapia , Sistema de Registros
9.
ASAIO J ; 68(7): 899-906, 2022 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-34643575

RESUMO

Iron deficiency (ID) is a common comorbidity in heart failure (HF). In these patients, intravenous iron administration can improve clinical outcomes and quality of life (QoL). However, data on ID are lacking in patients who have transitioned toward left ventricular assist device (LVAD) or heart transplantation (HTx). All patients who underwent LVAD (n = 84) surgery or HTx (n = 67) at our center between 2012 and 2019, aged ≥18 years with a follow-up of ≥3 months, were included. Retrospectively, the prevalence of ID up to 1 year preoperatively, and up to February 2020 postoperatively, as well as all iron administrations were assessed during this period. Iron status was assessed in 61% and 51% of the LVAD and HTx patients preoperatively, and 81% and 84%, respectively, postoperatively. Of these patients, 53% and 71% of the LVAD and HTx patients preoperatively were diagnosed with ID preoperatively, and 71% and 77%, respectively, postoperatively. ID was more frequently diagnosed >3 months postoperatively. Sixty-three percent of the LVAD (mostly intravenous) and 63% of the HTx patients (mostly oral) received iron administration. ID is highly prevalent pre- and post-LVAD and HTx. It is plausible that substitution can have similar QoL gains as in regular HF patients.


Assuntos
Insuficiência Cardíaca , Transplante de Coração , Coração Auxiliar , Deficiências de Ferro , Adolescente , Adulto , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/cirurgia , Transplante de Coração/efeitos adversos , Coração Auxiliar/efeitos adversos , Humanos , Ferro/uso terapêutico , Prevalência , Qualidade de Vida , Estudos Retrospectivos , Resultado do Tratamento
10.
Int J Cardiol ; 359: 39-45, 2022 07 15.
Artigo em Inglês | MEDLINE | ID: mdl-35439583

RESUMO

BACKGROUND: Significant aortic regurgitation at the time of left ventricular assist device (LVAD) implantation, requires concomitant aortic valve (AoV) replacement or repair. However, the impact of concomitant AoV surgery on morbidity remains unknown. Therefore, our aim is to determine the impact of concomitant AoV surgery on thromboembolic and bleeding events. METHODS: A retrospective IMACS registry study, including patients implanted from 2013 until September 2017. Differences between different concomitant AoV surgery modalities were analyzed. RESULTS: In total, 785 (5.1%) out of 15.267 patients (median age 58 IQR 49-66 years, 79% male) underwent concomitant AoV surgery (median age 63 IQR 54-69 years, 84% male); 386 (49%) patients received biological prostheses, 71 (9%) mechanical prostheses and 328 (42%) AoV repairs. In total, 54 (8%) patients with AoV surgery experienced a thromboembolic event and 1016 (9%) patients with no AoV surgery. Furthermore, concomitant AoV surgery was associated with an increased rate of all and nonsurgical bleedings. Following a multivariable Cox regression, concomitant AoV surgery remained an independent predictor for bleeding events. CONCLUSIONS: In LVAD patients undergoing concomitant AoV surgery, thromboembolic event rates were not higher, however both all and nonsurgical bleeding event rates were higher.


Assuntos
Insuficiência da Valva Aórtica , Insuficiência Cardíaca , Coração Auxiliar , Tromboembolia , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/diagnóstico , Insuficiência da Valva Aórtica/epidemiologia , Insuficiência da Valva Aórtica/cirurgia , Feminino , Coração Auxiliar/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Tromboembolia/diagnóstico , Tromboembolia/epidemiologia , Tromboembolia/etiologia , Resultado do Tratamento
11.
ESC Heart Fail ; 9(2): 1239-1247, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35174653

RESUMO

AIMS: The need for permanent pacemakers (PMs) after heart transplantation (HT) is increasing. The aim was to determine the influence of cardiac allograft vasculopathy (CAV), donor age, and other risk factors on PM implantations early and late after HT and its effect on survival. METHODS AND RESULTS: A retrospective, single-centre study was performed including HTs from 1984 to July 2018. Early PM was defined as PM implantation ≤90 days and late PM as PM > 90 days. Risk factors for PM and survival after PM were determined with (time-dependent) multivariable Cox regression. Out of 720 HTs performed, 62 were excluded (55 mortalities ≤30 days and 7 retransplantations). Of the remaining 658 patients, 95 (14%) needed a PM: 38 (6%) early and 57 (9%) late during follow-up (median 9.3 years). Early PM risk factors were donor age [hazard ratio (HR) 1.06, P < 0.001], ischaemic time (HR 1.01, P < 0.001), and in adults amiodarone use before HT (HR 2.02, P = 0.045). Late PM risk factors were donor age (HR 1.03, P = 0.024) and CAV (HR 3.59, P < 0.001). Late PM compromised survival (HR 2.05, P < 0.001), while early PM did not (HR 0.77, P = 0.41). CONCLUSIONS: Risk factors for early PM implantation were donor age, ischaemic time, and in adults amiodarone use before HT. Late PM implantation risk factors were donor age and CAV. Late PM diminished survival, which is probably a surrogate marker for underlying progressive cardiac disease.


Assuntos
Cardiopatias , Transplante de Coração , Marca-Passo Artificial , Adulto , Aloenxertos , Transplante de Coração/efeitos adversos , Humanos , Estudos Retrospectivos
12.
ESC Heart Fail ; 9(1): 353-362, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34862765

RESUMO

AIMS: Although diabetes mellitus (DM) is a common co-morbidity in chronic heart failure (HF) patients, European data on concurrent HF and DM treatment are lacking. Therefore, we have studied the HF treatment of patients with and without DM. Additionally, with the recent breakthrough of sodium-glucose cotransporter 2 (SGLT2) inhibitors in the field of HF, we studied the potential impact of this new drug in a large cohort of HF patients. METHODS AND RESULTS: A total of 7488 patients with chronic HF with a left ventricular ejection fraction <50% from 34 Dutch outpatient HF clinics between 2013 and 2016 were analysed on diabetic status and background HF therapy. Average age of the total population was 72.8 years (±11.7 years), and 64% of the patients were male. Diabetes was present in 29% of the patients (N = 2174). Diabetics had a worse renal function (mean estimated glomerular filtration rate 56 vs. 61 mL/min/1.73 m2 , P < 0.001). Renin-angiotensin system inhibitors were less often prescribed in diabetics compared with non-diabetics (79% vs. 82%, P = 0.001), while no significant differences regarding other guideline-recommended HF drugs were found. Target doses of beta-blockers (23% vs. 16%, P < 0.001), renin-angiotensin system inhibitors (47% vs. 43%, P = 0.009), and mineralocorticoid receptor antagonists (57% vs. 51%, P = 0.005) were more often prescribed in diabetics than non-diabetics. Based on the latest trials on SGLT2 inhibitors, 31-64% of all HF patients would fulfil the eligibility or enrichment criteria (with vs. without N-terminal prohormone BNP criterion). CONCLUSIONS: In this large real-world HF registry, a high prevalence of DM was observed and diabetics more often received guideline-recommended target doses. Based on current evidence, the majority of patients would fulfil the enrichment criteria of SGLT2 trials in HF and the impact of this new drug class will be large.


Assuntos
Diabetes Mellitus , Insuficiência Cardíaca , Idoso , Insuficiência Cardíaca/tratamento farmacológico , Insuficiência Cardíaca/epidemiologia , Humanos , Masculino , Antagonistas de Receptores de Mineralocorticoides/farmacologia , Antagonistas de Receptores de Mineralocorticoides/uso terapêutico , Volume Sistólico , Função Ventricular Esquerda
13.
Eur Heart J Case Rep ; 5(4): ytab112, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34268473

RESUMO

BACKGROUND: Pulmonary hypertension (PH) is most commonly caused by left-sided heart disease and may negatively affect the long-term prognosis and quality of life of patients with chronic heart failure (CHF). CardioMEMS (Micro-Electro-Mechanical-System) allows physicians to monitor pulmonary artery (PA) pressures remotely and optimize heart failure treatment based on haemodynamic parameters, which provides further insight into the effect of valvular interventions. CASE SUMMARY: We present a case of a 61-year-old male patient with an ischaemic cardiomyopathy, poor LV function, moderate to severe mitral regurgitation, and severe aortic valve regurgitation in refractory heart failure. Right heart catheterization and CardioMEMS monitoring revealed severe pulmonary hypertension with mean PA pressures of 55 mmHg and a mean pulmonary capillary wedge pressure of 21 mmHg despite up titration of heart failure medication and sildenafil. Pulmonary and systemic causes of pulmonary hypertension were excluded. After heart team consensus, the patient underwent transcatheter aortic valve implantation (TAVI) which resulted in normalization of PA pressures and a significant improvement of functional performance. DISCUSSION: To the best of our knowledge, this is the first case report describing the direct effects of TAVI on continuous PA pressures in a patient with poor LV function and severe aortic regurgitation. Elective TAVI appeared to be safe and very effective in reverting severe pulmonary hypertension. Most strikingly, drug interventions could not affect the elevated pulmonary pressures, but TAVI corrected the aortic valve insufficiency with normalization of left-sided pulmonary hypertension.

14.
Future Cardiol ; 17(5): 885-898, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-33410726

RESUMO

Aim: We aimed to assess the safety and feasibility of using CardioMEMS monitoring in patients before and after left ventricular assist device (LVAD) surgery. Patients & methods: Ten patients accepted for elective LVAD surgery were included, received a CardioMEMS at baseline and were categorized based on mean pulmonary artery pressure (mPAP) ≤25 mmHg (n = 4) or mPAP >25 mmHg [n = 6]) before LVAD surgery. Results: The combined end point of all-cause mortality, acute kidney injury and/or renal replacement therapy, and right ventricular failure occurred more often in patients with an mPAP >25 mmHg (83 vs 0%, p = 0.017). Conclusion: This pilot study demonstrates that combining CardioMEMS monitoring with LVAD therapy is safe and generates the hypothesis that patients with an mPAP >25 mmHg before LVAD surgery identify a very high-risk group for adverse clinical outcomes.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Insuficiência Cardíaca/terapia , Hemodinâmica , Humanos , Projetos Piloto , Estudos Retrospectivos , Resultado do Tratamento
15.
ESC Heart Fail ; 8(4): 2679-2689, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-33934556

RESUMO

AIMS: This study aimed to investigate the left ventricular (LV) remodelling and long-term prognosis of patients with new-onset acute heart failure (HF) with reduced ejection fraction who were pharmacologically managed and survived until hospital discharge. We compared patients with ischaemic and non-ischaemic aetiology. METHODS AND RESULTS: This cohort study consisted of 111 patients admitted with new-onset acute HF in the period 2008-2016 [62% non-ischaemic aetiology, 48% supported by inotropes, vasopressors, or short-term mechanical circulatory devices, and left ventricular ejection fraction (LVEF) at discharge 28% (interquartile range 22-34)]. LV dimensions, LVEF, and mitral valve regurgitation were used as markers for LV remodelling during up to 3 years of follow-up. Both patients with non-ischaemic and ischaemic HF had significant improvement in LVEF (P < 0.001 and P = 0.004, respectively) with significant higher improvement in those with non-ischaemic HF (17% vs. 6%, P < 0.001). Patients with non-ischaemic HF had reduction in LV end-diastolic and end-systolic diameters (6 and 10 mm, both P < 0.001), but this was not found in those with ischaemic HF [+3 mm (P = 0.09) and +2 mm (P = 0.07), respectively]. During a median follow-up of 4.6 years, 98 patients (88%) did not reach the composite endpoint of LV assist device implantation, heart transplantation, or all-cause mortality, with no difference between with ischaemic and non-ischaemic HF [hazard ratio 0.69 (95% confidence interval 0.19-2.45)]. CONCLUSIONS: Patients with new-onset acute HF with reduced ejection fraction discharged on optimal medical treatment have a good prognosis. We observed a considerable LV remodelling with improvement in LV function and dimensions, starting already at 6 months in patients with non-ischaemic HF but not in their ischaemic counterparts.


Assuntos
Insuficiência Cardíaca , Remodelação Ventricular , Estudos de Coortes , Humanos , Prognóstico , Volume Sistólico , Função Ventricular Esquerda
16.
Eur J Prev Cardiol ; 28(9): 957-965, 2021 08 09.
Artigo em Inglês | MEDLINE | ID: mdl-34402878

RESUMO

AIMS: A recent study suggested that women with heart failure and heart failure reduced ejection fraction might hypothetically need lower doses of angiotensin-converting enzyme inhibitors or angiotensin II receptor blockers ( = renin-angiotensin-system inhibitors) and ß-blockers than men to achieve the best outcome. We assessed the current medical treatment of heart failure reduced ejection fraction in men and women in a large contemporary cohort and address the hypothetical impact of changing treatment levels in women. METHODS: This analysis is part of a large contemporary quality of heart failure care project which includes 5320 (64%) men and 3003 (36%) women with heart failure reduced ejection fraction. Detailed information on heart failure therapy prescription and dosage were collected. RESULTS: Women less often received renin-angiotensin-system inhibitors (79% vs 83%, p < 0.01), but more often ß-blockers (82% vs 79%, p < 0.01) than men. Differences in guideline-recommended target doses between sexes were relatively small. Implementing a hypothetical sex-specific dosing schedule (at 50% of the current recommended dose in the European Society of Cardiology guidelines in women only) would lead to significantly higher levels of women receiving appropriate dosing (ß-blocker 87% vs 54%, p < 0.01; renin-angiotensin-system inhibitor 96% vs 75%, p < 0.01). Most interestingly, the total number of women with >100% of the new hypothetical target dose would be 24% for ß-blockers and 52% for renin-angiotensin-system inhibitors, which can be considered as relatively overdosed. CONCLUSION: In this large contemporary heart failure registry, there were significant but relatively small differences in drug dose between men and women with heart failure reduced ejection fraction. Implementation of the hypothetical sex-specific target dosing schedule would lead to considerably more women adequately treated. In contrast, we identified a group of women who might have been relatively overdosed with increased risk of side-effects and intolerance.


Assuntos
Insuficiência Cardíaca , Antagonistas de Receptores de Mineralocorticoides , Antagonistas Adrenérgicos beta/efeitos adversos , Antagonistas de Receptores de Angiotensina/efeitos adversos , Inibidores da Enzima Conversora de Angiotensina/efeitos adversos , Feminino , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/tratamento farmacológico , Humanos , Masculino , Antagonistas de Receptores de Mineralocorticoides/uso terapêutico , Volume Sistólico
17.
Int J Cardiol ; 340: 26-33, 2021 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-34437934

RESUMO

BACKGROUND: There is conflicting observational data on the survival benefit cardiac implantable electronic devices (CIED) in patients with LVADs. METHODS: Patients in whom an LVAD was implanted between January 2008 and April 2017 in the multinational Trans-Atlantic Registry on VAD and Transplant (TRAViATA) registry were separated into four groups based on the presence of CIED prior to LVAD implantation: none (n = 146), implantable cardiac defibrillator (ICD) (n = 239), cardiac resynchronization without defibrillator (CRT-P) (n = 28), and CRT with defibrillator (CRT-D) (n = 111). RESULTS: A total of 524 patients (age 52 years ±12, 84.4% male) were followed for 354 (interquartile range: 166-701) days. After multivariable adjustment, there were no differences in survival across the groups. In comparison to no device, only CRT-D was associated with late right ventricular failure (RVF) (hazard ratio 2.85, 95% confidence interval [CI] 1.42-5.72, p = 0.003). There was no difference in risk of early RVF across the groups or risk of ICD shocks between those with ICD and CRT-D. CONCLUSION: In a multinational registry of patients with LVADs, there were no differences in survival with respect to CIED subtype. However, patients with a pre-existing CRT-D had a higher likelihood of late RVF suggesting significant long-term morbidity in those with devices capable of LV­lead pacing post LVAD implantation.


Assuntos
Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Insuficiência Cardíaca , Coração Auxiliar , Eletrônica , Feminino , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
18.
Gen Thorac Cardiovasc Surg ; 68(3): 209-218, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31981137

RESUMO

Left ventricular assist devices (LVAD) are frequently used in the treatment of end-stage heart failure (HF), and due to the shortage of heart donors and destination programs, it is likely to keep on growing. Still, LVAD therapy is not without complications and morbidity and rehospitalization rates are high. New ways to improve LVAD care both from the side of the patient and the physician are warranted. Remote monitoring could be a tool to tailor treatment in these patients, as no feedback exists at all about patient functioning on top of the static pump parameters. We aim to provide an overview and evaluation of the novel remote monitoring strategies to optimize LVAD management and elaborate on the opportunities of remote hemodynamic monitoring with CardioMEMS, at home in these patients as the next step to improve care.


Assuntos
Insuficiência Cardíaca/cirurgia , Coração Auxiliar/efeitos adversos , Disfunção Ventricular Esquerda/cirurgia , Monitorização Ambulatorial da Pressão Arterial , Impedância Elétrica , Insuficiência Cardíaca/etiologia , Ventrículos do Coração/cirurgia , Monitorização Hemodinâmica , Hemodinâmica , Humanos , Qualidade de Vida , Tecnologia de Sensoriamento Remoto , Tecnologia sem Fio
19.
Eur J Heart Fail ; 22(10): 1878-1887, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32809227

RESUMO

AIMS: The aim of this study was to compare early- and late-term survival and causes of death between patients with and without a concomitant aortic valve (AoV) procedure during continuous-flow left ventricular assist device (LVAD) surgery. METHODS AND RESULTS: All adult primary continuous-flow LVAD patients on the International Society of Heart and Lung Transplantation (ISHLT) Mechanically Assisted Circulatory Support (IMACS) Registry (n = 15 267) were included in this analysis and stratified into patients submitted to a concomitant AoV procedure (AoV replacement or AoV repair) and patients without an AoV procedure. The primary outcome was early (≤90 days) survival post-LVAD surgery. Secondary outcomes were late survival (survival during the entire follow-up period) and conditional survival (in patients who survived the first 90 days post-LVAD surgery), and determinants. Patients who underwent concomitant AoV replacement (n = 457) had significantly reduced late survival compared with patients with AoV repair (n = 328) or without an AoV procedure (n = 14 482) (56% vs. 61% and 62%, respectively; P = 0.001). After adjustment for other significant predictors, concomitant AoV replacement remained an independent predictor for early [hazard ratio (HR) 1.226, 95% confidence interval (CI) 1.037-1.449] and late (HR 1.477, 95% CI 1.154-1.890) mortality. However, patients undergoing AoV replacement or repair, in whom the presence of moderate-to-severe AoV regurgitation was diagnosed prior to LVAD implantation, had survival similar to patients not undergoing AoV interventions. CONCLUSIONS: Concomitant AoV surgery in patients undergoing LVAD implantation is an independent predictor of mortality. Additional research is needed to determine the best AoV surgical strategy at the time of LVAD surgery.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Adulto , Valva Aórtica/cirurgia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Sistema de Registros , Estudos Retrospectivos , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda , Função Ventricular Direita
20.
ESC Heart Fail ; 7(5): 3208-3212, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32729665

RESUMO

Data on the risk of aortic root thrombosis in patients with aortic valve replacement (AVR) and left ventricular assist device (LVAD) surgery are scarce. Two out of nine patients receiving AVR concomitant with LVAD surgery and two out of two patients receiving AVR on LVAD support, at our centre, developed an aortic root thrombus, all diagnosed with computed tomography (CT) angiography. These results demonstrate that patients with concomitant AVR and LVAD surgery, or AVR on LVAD support, have an increased risk of aortic root thrombosis. Therefore, early anti-thrombotic therapy and vigilant diagnostic follow-up, using CT scans, are warranted to prevent thromboembolic events.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Trombose , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/etiologia , Coração Auxiliar/efeitos adversos , Humanos , Trombose/diagnóstico , Trombose/etiologia , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa