Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 57
Filtrar
1.
Eur Heart J ; 43(29): 2801-2811, 2022 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-35560020

RESUMO

AIMS: To investigate the association between the timing of cardiac surgery during pregnancy and both maternal and foetal outcomes. METHODS AND RESULTS: Studies published up to 6 February 2021 on maternal and/or foetal mortality after cardiac surgery during pregnancy that included individual patient data were identified. Maternal and foetal mortality was analysed per trimester for the total population and stratified for patients who underwent caesarean section (CS) prior to cardiac surgery (Caesarean section (CaeSe) group) vs. patients who did not (Cardiac surgery (CarSu) group). Multivariable logistic regression analysis was performed to evaluate predictors of both maternal and foetal mortality. In total, 179 studies were identified including 386 patients of which 120 underwent CS prior to cardiac surgery. Maternal mortality was 7.3% and did not differ significantly among trimesters of pregnancy (P = 0.292) nor between subgroup CaeSe and CarSu (P = 0.671). Overall foetal mortality was 26.5% and was lowest when cardiac surgery was performed during the third trimester (10.3%, P < 0.01). CS prior to surgery was significantly associated with a reduced risk of foetal mortality in a multivariable model [odds ratio 0.19, 95% confidence interval [0.06-0.56)]. Trimester was not identified as an independent predictor for foetal nor maternal mortality. CONCLUSION: Maternal mortality after cardiac surgery during pregnancy is not associated with the trimester of pregnancy. Cardiac surgery is associated with high foetal mortality but is significantly lower in women where CS is performed prior to cardiac surgery. When the foetus is viable, CS prior to cardiac surgery might be safe. When CS is not feasible, trimester stage does not seem to influence foetal mortality.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Complicações Cardiovasculares na Gravidez , Trimestres da Gravidez , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Procedimentos Cirúrgicos Cardíacos/métodos , Cesárea , Feminino , Mortalidade Fetal , Humanos , Mortalidade Materna , Gravidez , Complicações Cardiovasculares na Gravidez/cirurgia , Resultado da Gravidez , Fatores de Tempo
2.
J Cell Mol Med ; 25(23): 10869-10878, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34725901

RESUMO

Tissue engineering (TE) of long tracheal segments is conceptually appealing for patients with inoperable tracheal pathology. In tracheal TE, stem cells isolated from bone marrow or adipose tissue have been employed, but the ideal cell source has yet to be determined. When considering the origin of stem cells, cells isolated from a source embryonically related to the trachea may be more similar. In this study, we investigated the feasibility of isolating progenitor cells from pleura and pericard as an alternative cells source for tracheal tissue engineering. Porcine progenitor cells were isolated from pleura, pericard, trachea and adipose tissue and expanded in culture. Isolated cells were characterized by PCR, RNA sequencing, differentiation assays and cell survival assays and were compared to trachea and adipose-derived progenitor cells. Progenitor-like cells were successfully isolated and expanded from pericard and pleura as indicated by gene expression and functional analyses. Gene expression analysis and RNA sequencing showed a stem cell signature indicating multipotency, albeit that subtle differences between different cell sources were visible. Functional analysis revealed that these cells were able to differentiate towards chondrogenic, osteogenic and adipogenic lineages. Isolation of progenitor cells from pericard and pleura with stem cell features is feasible. Although functional differences with adipose-derived stem cells were limited, based on their gene expression, pericard- and pleura-derived stem cells may represent a superior autologous cell source for cell seeding in tracheal tissue engineering.


Assuntos
Células-Tronco Multipotentes/citologia , Pericárdio/citologia , Pleura/citologia , Traqueia/citologia , Adipócitos/citologia , Adipogenia/fisiologia , Tecido Adiposo/citologia , Animais , Células da Medula Óssea/citologia , Diferenciação Celular/fisiologia , Condrogênese/fisiologia , Humanos , Células-Tronco Mesenquimais/efeitos dos fármacos , Osteogênese/fisiologia , Células-Tronco/citologia , Suínos , Engenharia Tecidual/métodos
4.
Br J Cancer ; 121(5): 372-377, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-31337877

RESUMO

BACKGROUND: Retrospective studies suggest that low molecular weight heparin may delay the development of metastasis in patients with resected NSCLC. METHODS: Multicentre phase 3 study with patients with completely resected NSCLC who were randomised after surgery to receive chemotherapy with or without nadroparin. The main exclusion criteria were R1/2 and wedge/segmental resection. FDG-PET was required. The primary endpoint was recurrence-free survival (RFS). RESULTS: Among 235 registered patients, 202 were randomised (nadroparin: n = 100; control n = 102). Slow accrual enabled a decrease in the number of patients needed from 600 to 202, providing 80% power to compare RFS with 94 events (α = 0.05; 2-sided). There were no differences in bleeding events between the two groups. The median RFS was 65.2 months (95% CI, 36-NA) in the nadroparin arm and 37.7 months (95% CI, 22.7-NA) in the control arm (HR 0.77 (95% CI, 0.53-1.13, P = 0.19). FDG-PET SUVmax ≥10 predicted a greater likelihood of recurrence in the first year (HR 0.48, 95% CI 0.22-0.9, P = 0.05). CONCLUSIONS: Adjuvant nadroparin did not improve RFS in patients with resected NSCLC. In this study, a high SUVmax predicted a greater likelihood of recurrence in the first year. CLINICAL TRIAL REGISTRATION: Netherlands Trial registry: NTR1250/1217.


Assuntos
Anticoagulantes/uso terapêutico , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico , Carcinoma Pulmonar de Células não Pequenas/tratamento farmacológico , Carcinoma de Células Escamosas/tratamento farmacológico , Neoplasias Pulmonares/tratamento farmacológico , Nadroparina/uso terapêutico , Pneumonectomia , Idoso , Carcinoma Pulmonar de Células não Pequenas/diagnóstico por imagem , Carcinoma Pulmonar de Células não Pequenas/patologia , Carcinoma de Células Escamosas/patologia , Quimioterapia Adjuvante , Cisplatino/administração & dosagem , Desoxicitidina/administração & dosagem , Desoxicitidina/análogos & derivados , Intervalo Livre de Doença , Feminino , Fluordesoxiglucose F18 , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/patologia , Masculino , Pessoa de Meia-Idade , Recidiva Local de Neoplasia/epidemiologia , Estadiamento de Neoplasias , Pemetrexede/administração & dosagem , Tomografia por Emissão de Pósitrons , Gencitabina
5.
BMC Surg ; 18(1): 27, 2018 May 18.
Artigo em Inglês | MEDLINE | ID: mdl-29776444

RESUMO

BACKGROUND: In case of suspicious lymph nodes on computed tomography (CT) or fluorodeoxyglucose positron emission tomography (FDG-PET), advanced tumour size or central tumour location in patients with suspected non-small cell lung cancer (NSCLC), Dutch and European guidelines recommend mediastinal staging by endosonography (endobronchial ultrasound (EBUS) and endoscopic ultrasound (EUS)) with sampling of mediastinal lymph nodes. If biopsy results from endosonography turn out negative, additional surgical staging of the mediastinum by mediastinoscopy is advised to prevent unnecessary lung resection due to false negative endosonography findings. We hypothesize that omitting mediastinoscopy after negative endosonography in mediastinal staging of NSCLC does not result in an unacceptable percentage of unforeseen N2 disease at surgical resection. In addition, omitting mediastinoscopy comprises no extra waiting time until definite surgery, omits one extra general anaesthesia and hospital admission, and may be associated with lower morbidity and comparable survival. Therefore, this strategy may reduce health care costs and increase quality of life. The aim of this study is to compare the cost-effectiveness and cost-utility of mediastinal staging strategies including and excluding mediastinoscopy. METHODS/DESIGN: This study is a multicenter parallel randomized non-inferiority trial comparing two diagnostic strategies (with or without mediastinoscopy) for mediastinal staging in 360 patients with suspected resectable NSCLC. Patients are eligible for inclusion when they underwent systematic endosonography to evaluate mediastinal lymph nodes including tissue sampling with negative endosonography results. Patients will not be eligible for inclusion when PET/CT demonstrates 'bulky N2-N3' disease or the combination of a highly suspicious as well as irresectable mediastinal lymph node. Primary outcome measure for non-inferiority is the proportion of patients with unforeseen N2 disease at surgery. Secondary outcome measures are hospitalization, morbidity, overall 2-year survival, quality of life, cost-effectiveness and cost-utility. Patients will be followed up 2 years after start of treatment. DISCUSSION: Results of the MEDIASTrial will have immediate impact on national and international guidelines, which are accessible to public, possibly reducing mediastinoscopy as a commonly performed invasive procedure for NSCLC staging and diminishing variation in clinical practice. TRIAL REGISTRATION: The trial is registered at the Netherlands Trial Register on July 6th, 2017 ( NTR 6528 ).


Assuntos
Carcinoma Pulmonar de Células não Pequenas/patologia , Endossonografia/métodos , Neoplasias Pulmonares/patologia , Mediastinoscopia/métodos , Carcinoma Pulmonar de Células não Pequenas/cirurgia , Análise Custo-Benefício , Humanos , Neoplasias Pulmonares/cirurgia , Linfonodos/patologia , Mediastino/patologia , Estadiamento de Neoplasias , Países Baixos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Tomografia por Emissão de Pósitrons , Qualidade de Vida , Tomografia Computadorizada por Raios X
6.
Radiology ; 283(2): 547-559, 2017 05.
Artigo em Inglês | MEDLINE | ID: mdl-27846378

RESUMO

Purpose To assess whether dynamic fluorine 18 (18F) fluorodeoxyglucose (FDG) positron emission tomography (PET) has added value over static 18F-FDG PET for tumor delineation in non-small cell lung cancer (NSCLC) radiation therapy planning by using pathology volumes as the reference standard and to compare pharmacokinetic rate constants of 18F-FDG metabolism, including regional variation, between NSCLC histologic subtypes. Materials and Methods The study was approved by the institutional review board. Patients gave written informed consent. In this prospective observational study, 1-hour dynamic 18F-FDG PET/computed tomographic examinations were performed in 35 patients (36 resectable NSCLCs) between 2009 and 2014. Static and parametric images of glucose metabolic rate were obtained to determine lesion volumes by using three delineation strategies. Pathology volume was calculated from three orthogonal dimensions (n = 32). Whole tumor and regional rate constants and blood volume fraction (VB) were computed by using compartment modeling. Results Pathology volumes were larger than PET volumes (median difference, 8.7-25.2 cm3; Wilcoxon signed rank test, P < .001). Static fuzzy locally adaptive Bayesian (FLAB) volumes corresponded best with pathology volumes (intraclass correlation coefficient, 0.72; P < .001). Bland-Altman analyses showed the highest precision and accuracy for static FLAB volumes. Glucose metabolic rate and 18F-FDG phosphorylation rate were higher in squamous cell carcinoma (SCC) than in adenocarcinoma (AC), whereas VB was lower (Mann-Whitney U test or t test, P = .003, P = .036, and P = .019, respectively). Glucose metabolic rate, 18F-FDG phosphorylation rate, and VB were less heterogeneous in AC than in SCC (Friedman analysis of variance). Conclusion Parametric images are not superior to static images for NSCLC delineation. FLAB-based segmentation on static 18F-FDG PET images is in best agreement with pathology volume and could be useful for NSCLC autocontouring. Differences in glycolytic rate and VB between SCC and AC are relevant for research in targeting agents and radiation therapy dose escalation. © RSNA, 2016 Online supplemental material is available for this article.


Assuntos
Carcinoma Pulmonar de Células não Pequenas/metabolismo , Carcinoma Pulmonar de Células não Pequenas/patologia , Fluordesoxiglucose F18/farmacocinética , Glucose/metabolismo , Neoplasias Pulmonares/metabolismo , Neoplasias Pulmonares/patologia , Idoso , Idoso de 80 Anos ou mais , Biomarcadores Tumorais/metabolismo , Carcinoma Pulmonar de Células não Pequenas/diagnóstico por imagem , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Neoplasias Pulmonares/diagnóstico por imagem , Masculino , Taxa de Depuração Metabólica , Pessoa de Meia-Idade , Imagem Molecular/métodos , Estadiamento de Neoplasias , Tomografia por Emissão de Pósitrons/métodos , Compostos Radiofarmacêuticos/farmacocinética , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
8.
J Med Eng Technol ; : 1-11, 2024 Jul 25.
Artigo em Inglês | MEDLINE | ID: mdl-39049730

RESUMO

Prolonged air leakage (AL) following pulmonary resections leads to prolonged hospital stay and post-operative complications. Intra- and postoperative quantification of AL might be useful for improving treatment decisions, but these measurements have not been characterised. AL calculations based on inspiratory and expiratory tidal volumes were investigated in an Intensive Care Unit mechanical ventilator circuit (Servo-I). AL was also measured by a digital chest drainage system. This study shows that AL measurements increase in accuracy when corrected for baseline deviations (R: 0.904 > 0.997, p < 0.001). Bland-Altman analysis revealed a funnel-shape, indicative of a detection threshhold. Corrected measurements were most accurate when averaged over five breaths and AL was >500 mL/min, with an estimated mean systemic bias of 7.4% (95%-limits of agreement [LoA]: 1.1%-13.7%) at 500 mL/min air leak. Breath-by-breath analysis showed most accurate results at AL >20 mL/breath (R: 0.989-0.991, p < 0.001) at tidal volumes between 350-600 mL. The digital drain had a mean systemic bias of -11.1% (95%-LoA: -18.9% to -3.3%) with homogenous scatter in Bland-Altman analysis and a strong correlation to the control measurement over a large range (0-2000mL/min, R: 0.999, p < 0.001). This study indicates that the Servo-I can be used for air leak quantification in clinically relevant ranges (>500 mL/min), but is unsuited for small leak detection due to a detection threshold. Researchers and clinicians should be aware of varying accuracy and interoperability characteristics between AL measurement devices.

9.
Artigo em Inglês | MEDLINE | ID: mdl-38833687

RESUMO

OBJECTIVES: More effective lung sealants are needed to prevent prolonged pulmonary air leakage (AL). Polyoxazoline-impregnated gelatin patch (N-hydroxysuccinimide ester functionalized poly(2-oxazoline)s; NHS-POx) was promising for lung sealing ex vivo. The aim of this study is to confirm sealing effectiveness in an in vivo model of lung injury. METHODS: An acute aerostasis model was used in healthy adult female sheep, involving bilateral thoracotomy, amputation lesions (bronchioles Ø > 1.5 mm), sealant application, digital chest tube for monitoring AL, spontaneous ventilation, obduction and bursting pressure measurement. Two experiments were performed: (i) 3 sheep with 2 lesions per lung (N = 4 NHS-POx double-layer, N = 4 NHS-POx single-layer, N = 4 untreated) and (ii) 3 with 1 lesion per lung (N = 3 NHS-POx single-layer, N = 3 untreated). In pooled linear regression, AL was analysed per lung (N = 7 NHS-POx, N = 5 untreated) and bursting pressure per lesion (N = 11 NHS-POx, N = 7 untreated). RESULTS: Baseline AL was similar between groups (mean 1.38-1.47 l/min, P = 0.90). NHS-POx achieved sealing in 1 attempt in 8/11 (72.7%) and in 10/11 (90.9%) in >1 attempt. Application failures were only observed on triangular lesions requiring 3 folds around the lung. No influences of methodological variation between experiments was detected in linear regression (P > 0.9). AL over initial 3 h of drainage was significantly reduced for NHS-POx [median: 7 ml/min, length of interquartile range: 333 ml/min] versus untreated lesions (367 ml/min, length of interquartile range: 680 ml/min, P = 0.036). Bursting pressure was higher for NHS-POx (mean: 33, SD: 16 cmH2O) versus untreated lesions (mean: 19, SD: 15 cmH2O, P = 0.081). CONCLUSIONS: NHS-POx was effective for reducing early AL, and a trend was seen for improvement of bursting strength of the covered defect. Results were affected by application characteristics and lesion geometry.

10.
Eur J Cancer ; 209: 114233, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-39053290

RESUMO

OBJECTIVE: Harmonized European NSCLC incidence, treatment approach, and survival based on national tumor registries are unclear. SUMMARY BACKGROUND DATA: Surgery has the potential to cure NSCLC and significantly prolong survival. This large-scale international study aimed to investigate treatment variations in Europe and the USA, as well as the determinants for its utilization. METHODS: The retrospective cohort study analyzed data from six European national population-based cancer registries (Belgium, Denmark, Estonia, Germany, the Netherlands, and Slovenia) and the US SEER database from 2010-2015. RESULTS: The study computed cancer incidence, survival, and age-standardized proportions of the use of various therapies. Multivariable logistic regression models were used to assess associations between resection and demographic and clinical parameters. A total of 428,107 records were analyzed. Among all countries, Estonia had the highest surgical resection rate (79.3 %) and the lowest radiation rate (7.3 %) for stage I patients. The Netherlands had the highest rate of radiotherapy across all years of investigation and the lowest surgery rate between 2012 and 2015. The primary treatment for early-stage NSCLC showed significant international variation, with the USA having a decrease in surgical rates from 67.6 % to 59.5 %. Resection was less frequently performed as tumor stage increased, patients aged, other lung cancer besides adenocarcinoma was present, and when the tumor site overlapped multiple lobes. CONCLUSIONS: Resection rates have declined in some studied European countries and the USA and resection rates vary substantially among countries. Interpretation of current scientific lung cancer evidence and international guidelines results in wide variations in patient treatment.


Assuntos
Carcinoma Pulmonar de Células não Pequenas , Neoplasias Pulmonares , Estadiamento de Neoplasias , Sistema de Registros , Humanos , Carcinoma Pulmonar de Células não Pequenas/patologia , Carcinoma Pulmonar de Células não Pequenas/terapia , Carcinoma Pulmonar de Células não Pequenas/epidemiologia , Carcinoma Pulmonar de Células não Pequenas/cirurgia , Estados Unidos/epidemiologia , Neoplasias Pulmonares/terapia , Neoplasias Pulmonares/patologia , Neoplasias Pulmonares/cirurgia , Neoplasias Pulmonares/epidemiologia , Europa (Continente) , Masculino , Feminino , Idoso , Pessoa de Meia-Idade , Estudos Retrospectivos , Adulto , Idoso de 80 Anos ou mais , Programa de SEER , Incidência
11.
Eur J Cardiothorac Surg ; 65(4)2024 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-38460190

RESUMO

OBJECTIVES: Compared to lung resections, airway procedures are relatively rare in thoracic surgery. Despite this, a growing number of dedicated airway centres have formed throughout Europe. These centres are characterized by a close interdisciplinary collaboration and they often act as supra-regional referring centres. To date, most evidence of airway surgery comes from retrospective, single-centre analysis as there is a lack of large-scale, multi-institutional databases. METHODS: In 2018, an initiative was formed, which aimed to create an airway database within the framework of the ESTS database (ESTS-AIR). Five dedicated airway centres were asked to test the database in a pilot phase. A 1st descriptive analysis of ESTS-AIR was performed. RESULTS: A total of 415 cases were included in the analysis. For adults, the most common indication for airway surgery was post-tracheostomy stenosis and idiopathic subglottic stenosis; in children, most resections/reconstructions had to be performed for post-intubation stenosis. Malignant indications required significantly longer resections [36.0 (21.4-50.6) mm] when compared to benign indications [26.6 (9.4-43.8) mm]. Length of hospital stay was 11.0 (4.1-17.3) days (adults) and 13.4 (7.6-19.6) days (children). Overall, the rates of complications were low with wound infections being reported as the most common morbidity. CONCLUSIONS: This evaluation of the 1st cases in the ESTS-AIR database allowed a large-scale analysis of the practice of airway surgery in dedicated European airway centres. It provides proof for the functionality of ESTS-AIR and sets the basis for rolling out the AIR subsection to all centres participating in the ESTS database.


Assuntos
Bases de Dados como Assunto , Cirurgia Torácica , Adulto , Criança , Humanos , Constrição Patológica , Intubação , Resultado do Tratamento , Estudos Multicêntricos como Assunto , Sociedades Médicas , Europa (Continente)
12.
Anesthesiology ; 118(3): 550-61, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23299364

RESUMO

BACKGROUND: Double-lumen tubes (DLTs) or bronchial blockers are commonly used for one-lung ventilation. DLTs are sometimes difficult or even impossible to introduce, and the incidence of postoperative hoarseness and airway injuries is higher. Bronchial blockers are more difficult to position and need more frequent intraoperative repositioning. The design of a Y-shaped bronchial blocker, the EZ-Blocker (Teleflex Life Sciences Ltd., Athlone, Ireland) (EZB), combines some advantages of both techniques. The objective of this study was to assess whether EZB performs clinically better than left-sided DLTs (Broncho-cath; Mallinckrodt, Athlone, Ireland) without causing more injury. Primary outcome was the frequency of initial malpositions. METHODS: Eligible patients were adults scheduled for surgery requiring one-lung ventilation who met criteria for placement of both devices. In this parallel trial, 100 consecutive and blinded patients were assigned randomly using a computer-generated list to two groups. The incidence of malposition and ease and time of placement were recorded. Blinded assessors investigated quality of lung deflation, postoperative complaints, and damage to the airway. RESULTS: Placement of a DLT was unsuccessful twice. The incidence of initial malposition was high and comparable between EZBs (37 of 50) and DLTs (42 of 49) (P = 0.212). Placing single-lumen tubes and EZBs took more time but was rated easier. Quality of lung deflation was comparable. Fewer patients in the EZB group complained of sore throat at day 1. There was a higher incidence of tracheal hematoma and redness and bronchial hematoma in the DLT group. CONCLUSIONS: The EZB is an efficient and effective device for one-lung ventilation and causes less injury and sore throat than a DLT.


Assuntos
Broncoscopia/efeitos adversos , Broncoscopia/instrumentação , Rouquidão/epidemiologia , Ventilação Monopulmonar/efeitos adversos , Ventilação Monopulmonar/instrumentação , Faringite/epidemiologia , Adulto , Idoso , Método Duplo-Cego , Desenho de Equipamento/instrumentação , Feminino , Rouquidão/prevenção & controle , Humanos , Intubação Intratraqueal/efeitos adversos , Intubação Intratraqueal/instrumentação , Intubação Intratraqueal/métodos , Masculino , Pessoa de Meia-Idade , Ventilação Monopulmonar/métodos , Faringite/prevenção & controle , Respiração Artificial/efeitos adversos , Respiração Artificial/instrumentação , Respiração Artificial/métodos , Resultado do Tratamento
13.
J Cardiothorac Surg ; 18(1): 289, 2023 Oct 12.
Artigo em Inglês | MEDLINE | ID: mdl-37828603

RESUMO

BACKGROUND: Aortic mycotic aneurysms are a rare but life-threatening condition and may be associated with aorto-bronchial- and aorto-esophageal fistulas. Although both very rare, they carry a high mortality and require (urgent) surgical intervention. Surviving all three conditions concomitantly is extraordinary. We describe a patient who underwent staged repair of such combined defects.


Assuntos
Aneurisma Infectado , Doenças da Aorta , Fístula Esofágica , Humanos , Aneurisma Infectado/diagnóstico por imagem , Aneurisma Infectado/cirurgia , Doenças da Aorta/cirurgia , Fístula Esofágica/diagnóstico , Fístula Esofágica/cirurgia
14.
Open Heart ; 10(1)2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-37094990

RESUMO

OBJECTIVE: Postoperative pericardial effusion (PPE) occurs frequently after cardiac surgery, potentially leading to life-threatening cardiac tamponade. Specific treatment guidelines are currently lacking, possibly leading to variations in clinical practice. Our goal was to assess clinical PPE management and evaluate variation between centres and clinicians. METHODS: A nationwide survey was sent to all interventional cardiologists and cardiothoracic surgeons in the Netherlands, regarding their preferred diagnostic and treatment modality of PPE. Clinical preferences were explored utilising four patient scenarios, each with a high/low echocardiographic and clinical suspicion of cardiac tamponade. Scenarios were also stratified by three PPE sizes (<1 cm, 1-2 cm, >2 cm). RESULTS: In total, 46/140 interventional cardiologists and 48/120 cardiothoracic surgeons responded (27/31 contacted centres). Cardiologists favoured routine postoperative echocardiography in all patients (44%), whereas cardiothoracic surgeons preferred routine imaging after specific procedures, especially mitral (85%) and tricuspid (79%) valve surgery. Overall, pericardiocentesis (83%) was preferred over surgical evacuation (17%). Regarding all patient scenarios, cardiothoracic surgeons significantly preferred evacuation compared with cardiologists (51% vs 37%, p<0.001). This was also observed with cardiologists employed in surgical centres compared with non-surgical centres (43% vs 31%, p=0.02). Inter-rater analysis varied from poor to near-excellent (к 0.22-0.67), suggesting varying PPE treatment preferences within one centre. CONCLUSION: There is significant variation in the preferred management of PPE between hospitals and clinicians, even within the same centre, possibly due to the lack of specific guidelines. Therefore, robust results of a systematic approach to PPE diagnosis and treatment are needed to formulate evidence-based recommendations and optimise patient outcome.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Tamponamento Cardíaco , Derrame Pericárdico , Humanos , Tamponamento Cardíaco/diagnóstico , Tamponamento Cardíaco/cirurgia , Derrame Pericárdico/cirurgia , Pericardiocentese/métodos , Ecocardiografia/métodos
15.
Artigo em Inglês | MEDLINE | ID: mdl-36802255

RESUMO

OBJECTIVES: Pain after thoracoscopic surgery may increase the incidence of postoperative complications and impair recovery. Guidelines lack consensus regarding postoperative analgesia. We performed a systematic review and meta-analysis to determine the mean pain scores of different analgesic techniques (thoracic epidural analgesia, continuous or single-shot unilateral regional analgesia and only systemic analgesia) after thoracoscopic anatomical lung resection. METHODS: Medline, Embase and Cochrane databases were searched until 1 October 2022. Patients undergoing at least >70% anatomical resections through thoracoscopy reporting postoperative pain scores were included. Due to a high inter-study variability an explorative meta-analysis next to an analytic meta-analysis was performed. The quality of evidence has been evaluated using the Grading of Recommendations Assessment, Development and Evaluation system. RESULTS: A total of 51 studies comprising 5573 patients were included. Mean 24, 48 and 72 h pain scores with 95% confidence interval on a 0-10 scale were calculated. Length of hospital stay, postoperative nausea and vomiting, additional opioids and the use of rescue analgesia were analysed as secondary outcomes. A common-effect size was estimated with an extreme high heterogeneity for which pooling of the studies was not appropriate. An exploratory meta-analysis demonstrated acceptable mean pain scores of Numeric Rating Scale <4 for all analgesic techniques. CONCLUSIONS: This extensive literature review and attempt to pool mean pain scores for meta-analysis demonstrates that unilateral regional analgesia is gaining popularity over thoracic epidural analgesia in thoracoscopic anatomical lung resection, despite great heterogeneity and limitations of current studies precluding such recommendations. PROSPERO REGISTRATION: ID number 205311.

16.
J Thorac Dis ; 15(2): 291-299, 2023 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-36910083

RESUMO

Background: Early-stage lung cancer is treated with curative intent by surgery or radiotherapy. However, upstaging is frequently seen after surgery in clinical N0 lung cancer patients, and despite curative intent, 2-year recurrence rates of 9-28% are reported. A sentinel lymph node (SLN) procedure could improve the staging accuracy. We explored the feasibility of performing a navigation bronchoscopy based SLN procedure in human ex-vivo lung cancer specimens to optimize procedural parameters and assess a novel injection tool. Methods: Ten lung resection specimens were included and allocated to either peri- or intratumoral injection of a tracer combining 99mTc-nanocolloid and indocyanine green (ICG) while varying the injection volume. A Pioneer Plus catheter with a pre-angulated 24G needle and an ultrasound (US)-element was used to perform real-time US guided transbronchial injections at multiple locations. Thereafter, single photon emission computed tomography/computed tomography (SPECT/CT)-scanning was performed to image injection depots and to assess their location relative to the tumor. Results: An average volume of 0.7 mL (range, 0.3-1.2 mL) with an average activity of 89.5 MBq 99mTc (range, 35.4-188.0 MBq) was injected. Intratumoral injections in non-solid and solid tumors were successful in 100% and 64.3% respectively, while 100% of peritumoral injections in solid tumors were successful. The US-element of the catheter allowed real-time imaging and was able to visualize all tumors and 67.4% of all injections. SPECT/CT-scanning visualized 76.7% of the injection depots. Conclusions: A navigation bronchoscopy mediated SLN procedure seems technically feasible. The Pioneer Plus is a suitable catheter to place tracer depots at multiple intra-/peri-tumoral sites, while receiving real-time feedback on the needle localization in relation to the tumor. The next step of in-vivo injections will determine if tracer drainage to the SLN can also be detected on pre- and per-operative imaging.

17.
J Thorac Dis ; 15(7): 3580-3592, 2023 Jul 31.
Artigo em Inglês | MEDLINE | ID: mdl-37559645

RESUMO

Background: Sealants are used to prevent prolonged pulmonary air leakage (PAL) after lung resections (incidence 5.6-30%). However, clinical evidence to support sealant use is insufficient, with an unmet need for a more effective product. We compared a novel gelatin patch impregnated with functionalized polyoxazolines (NHS-POx) (GATT-Patch) to commercially available sealant products. Methods: GATT-Patch Single/Double layers were compared to Progel®, Coseal®, Hemopatch® and TachoSil® in an ex vivo porcine lung model (first experiment). Based on these results, a second head-to-head comparison between GATT-Patch Single and Hemopatch® was performed. Air leakage (AL) was assessed in three settings using increasing ventilatory pressures (max =70 cmH2O): (I) baseline, (II) with 25 mm × 25 mm superficial pleural defect, and (III) after sealant application. Lungs floating on saline (37 ℃) were video recorded for visual AL assessment. Pressure and tidal volumes were collected from the ventilator, and bursting pressure (BP), AL and AL-reduction were determined. Results: Per sealant 10 measurements were performed (both experiments). In the first experiment, BP was superior for GATT-Patch Double (60±24 cmH2O) compared to TachoSil® (30±11 cmH2O, P<0.001), Hemopatch® (33±6 cmH2O, P=0.006), Coseal® (25±13 cmH2O, P=0.001) and Progel® (33±11 cmH2O, P=0.005). AL-reduction was superior for GATT-Patch Double (100%±1%) compared to Hemopatch® (46%±50%, P=0.010) and TachoSil® (31%±29%, P<0.001), and also for GATT-Patch Single (100%±14%, P=0.004) and Progel (89%±40%, P=0.027) compared to TachoSil®. In the second experiment, GATT-Patch Single was superior regarding BP (45±10 vs. 40±6 cmH2O, P=0.043) and AL-reduction (100%±11% vs. 68%±40%, P=0.043) when compared to Hemopatch®. Conclusions: The novel NHS-POx patch shows promise as a lung sealant, demonstrating elevated BP, good adhesive strength and a superior AL-reduction.

18.
J Clin Oncol ; 41(22): 3805-3815, 2023 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-37018653

RESUMO

PURPOSE: Resectable non-small-cell lung cancer (NSCLC) with a high probability of mediastinal nodal involvement requires mediastinal staging by endosonography and, in the absence of nodal metastases, confirmatory mediastinoscopy according to current guidelines. However, randomized data regarding immediate lung tumor resection after systematic endosonography versus additional confirmatory mediastinoscopy before resection are lacking. METHODS: Patients with (suspected) resectable NSCLC and an indication for mediastinal staging after negative systematic endosonography were randomly assigned to immediate lung tumor resection or confirmatory mediastinoscopy followed by tumor resection. The primary outcome in this noninferiority trial (noninferiority margin of 8% that previously showed to not compromise survival, Pnoninferior < .0250) was the presence of unforeseen N2 disease after tumor resection with lymph node dissection. Secondary outcomes were 30-day major morbidity and mortality. RESULTS: Between July 17, 2017, and October 5, 2020, 360 patients were randomly assigned, 178 to immediate lung tumor resection (seven dropouts) and 182 to confirmatory mediastinoscopy first (seven dropouts before and six after mediastinoscopy). Mediastinoscopy detected metastases in 8.0% (14/175; 95% CI, 4.8 to 13.0) of patients. Unforeseen N2 rate after immediate resection (8.8%) was noninferior compared with mediastinoscopy first (7.7%) in both intention-to-treat (Δ, 1.03%; UL 95% CIΔ, 7.2%; Pnoninferior = .0144) and per-protocol analyses (Δ, 0.83%; UL 95% CIΔ, 7.3%; Pnoninferior = .0157). Major morbidity and 30-day mortality was 12.9% after immediate resection versus 15.4% after mediastinoscopy first (P = .4940). CONCLUSION: On the basis of our chosen noninferiority margin in the rate of unforeseen N2, confirmatory mediastinoscopy after negative systematic endosonography can be omitted in patients with resectable NSCLC and an indication for mediastinal staging.


Assuntos
Carcinoma Pulmonar de Células não Pequenas , Neoplasias Pulmonares , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/cirurgia , Neoplasias Pulmonares/patologia , Carcinoma Pulmonar de Células não Pequenas/diagnóstico por imagem , Carcinoma Pulmonar de Células não Pequenas/cirurgia , Carcinoma Pulmonar de Células não Pequenas/patologia , Mediastinoscopia/métodos , Endossonografia/métodos , Estadiamento de Neoplasias , Linfonodos/diagnóstico por imagem , Linfonodos/cirurgia , Linfonodos/patologia
19.
Lab Anim ; 57(5): 504-517, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37032637

RESUMO

Sealants may provide a solution for pulmonary air leakage (PAL), but their clinical application is debatable. For sealant comparison, standardized animal models are lacking. This systematic review aims to assess methodology and quality of animal models for PAL and sealant evaluation. All animal models investigating lung sealing devices (e.g., staplers, glues, energy devices) to prevent or treat PAL were retrieved systematically from Embase, Pubmed and Web of science. Methodological study characteristics, risk of bias, reporting quality and publication bias were assessed. A total of 71 studies were included (N = 75 experiments, N = 1659 animals). Six different species and 18 strains were described; 92% of experiments used healthy animals, disease models were used in only six studies. Lesions to produce PAL were heterogenous, and only 11 studies used a previously reported technique, encompassing N = 5 unique lesions. Clinically relevant outcomes were used in the minority of studies (imaging 16%, air leak 10.7%, air leak duration 4%). Reporting quality was poor, but revealed an upward trend per decade. Overall, high risk of bias was present, and only 18.7% used a negative control group. All but one study without control groups claimed positive outcomes (95.8%), in contrast to 84.3% using positive or negative control groups, which also concluded equivocal, adverse or inconclusive outcomes. In conclusion, animal studies evaluating sealants for prevention of PAL are heterogenous and of poor reporting quality. Using negative control groups, disease models and quantifiable outcomes seem important to increase validity and relevance. Further research is needed to reach consensus for model development and standardization.


Assuntos
Modelos Animais , Pneumotórax , Adesivos Teciduais , Animais , Pneumotórax/prevenção & controle
20.
J Thorac Dis ; 15(9): 4703-4716, 2023 Sep 28.
Artigo em Inglês | MEDLINE | ID: mdl-37868902

RESUMO

Background: No validated and standardized animal models of pulmonary air leakage (PAL) exist for testing aerostatic efficacy of lung sealants. Lack of negative control groups in published studies and intrinsic sealing mechanisms of healthy animal lungs might contribute to a translational gap, leading to poor clinical results. This study aims to address the impact of intrinsic sealing mechanisms on the validity of PAL models, and investigate the conditions required for an ovine model of PAL for lung sealant testing. Methods: An ovine acute aerostasis model was developed, consisting of a bilateral thoracotomy with lesion creation, chest tube insertion and monitoring of air leaks using digital drains (≥80 minutes), under spontaneous respiration. Healthy mixed-breed adult female sheep were used and all in vivo procedures were performed under terminal anesthesia. Superficial parenchymal lesions were tested post-mortem and in vivo, extended lesions including bronchioles (deep bowl-shaped and sequential lung amputation lesions) were tested in vivo. Experiment outcomes include air leakage (AL), minimal leaking pressure (MLP) and histology. Results: Two post-mortem (N=4 superficial parenchymal lesions) and 10 in vivo experiments (N=5 superficial parenchymal and N=16 lesions involving bronchioles) were performed. In contrast to the post-mortem model, superficial parenchymal lesions in vivo showed less air leak [mean flow ± standard deviation (SD): 760±693 vs. 42±33 mL/min, P=0.055]. All superficial parenchymal lesions in vivo sealed intrinsically within a median time of 20 minutes [interquartile range (IQR), 10-75 minutes]. Histology of the intrinsic sealing layer revealed an extended area of alveolar collapse below the incision with intra-alveolar hemorrhage. Compared to superficial parenchymal lesions in vivo, lesions involving bronchioles induced significantly higher air leak post-operatively (normalized mean flow ± SD: 459±221 mL/min, P=0.003). At termination, 5/9 (55.6%) were still leaking (median drain time: 273 minutes, IQR, 207-435 minutes), and intrinsic sealing for the remaining lungs occurred within a median of 115 minutes (IQR, 52-245 minutes). Conclusions: Lung parenchyma of healthy sheep shows a strong intrinsic sealing mechanism, explained pathologically by an extended area of alveolar collapse, which may contribute to a translational gap in lung sealant research. A meaningful ovine model has to consist of deep lesions involving bronchioles of >⌀1.5 mm. Further research is needed to develop a standardized PAL model, to improve clinical effectiveness of lung sealants.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa