Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 54
Filtrar
1.
J Cardiovasc Electrophysiol ; 35(2): 290-300, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38098308

RESUMO

INTRODUCTION: Mitral valve prolapse (MVP) is a common clinical condition in the general population. A subgroup of patients with MVP may experience ventricular arrhythmias and sudden cardiac death ("arrhythmic mitral valve prolapse" [AMVP]) but how to stratify arrhythmic risk is still unclear. Our meta-analysis aims to identify predictive factors for arrhythmic risk in patients with MVP. METHODS: We systematically searched Medline, Cochrane, Journals@Ovid, Scopus electronic databases for studies published up to December 28, 2022 and comparing AMVP and nonarrhythmic mitral valve prolapse (NAMVP) for what concerns history, electrocardiographic, echocardiographic and cardiac magnetic resonance features. The effect size was estimated using a random-effect model as odds ratio (OR) and mean difference (MD). RESULTS: A total of 10 studies enrolling 1715 patients were included. Late gadolinium enhancement (LGE) (OR: 16.67; p = .005), T-wave inversion (TWI) (OR: 2.63; p < .0001), bileaflet MVP (OR: 1.92; p < .0001) and mitral anulus disjunction (MAD) (OR: 2.60; p < .0001) were more represented among patients with AMVP than in NAMVP. Patients with AMVP were shown to have longer anterior mitral leaflet (AML) (MD: 2.63 mm; p < .0001), posterior mitral leaflet (MD: 2.96 mm; p < .0001), thicker AML (MD: 0.49 mm; p < .0001), longer MAD length (MD: 1.24 mm; p < .0001) and higher amount of LGE (MD: 1.41%; p < .0001) than NAMVP. AMVP showed increased mechanical dispersion (MD: 8.04 ms; 95% confidence interval: 5.13-10.96; p < .0001) compared with NAMVP. CONCLUSIONS: Our meta-analysis proved that LGE, TWI, bileaflet MVP, and MAD are predictive factors for arrhythmic risk in MVP patients.

2.
Artigo em Inglês | MEDLINE | ID: mdl-38959377

RESUMO

BACKGROUND: The treatment of resistant coronary lesions (RCL) is a great challenge for interventional cardiologists. The excimer laser coronary atherectomy (ELCA) is a plaque modification tool based on a main mechanism of photomechanical effect leading to mechanical disruption of the plaque. Contrast dye injection during laser delivery has demonstrated to enhance its power. AIM: To evaluate the effectiveness and safety of the contrast-enhanced ELCA by a stepwise approach in the treatment of RCLs. METHODS: We retrospectively examined consecutive patients undergoing contrast-enhanced ELCA-assisted PCI between 2018 and 2021 at two Italian sites. RCLs were defined as novo or in-stent undilatable/uncrossable with conventional balloons (SC/NC balloon). The primary endpoint was ELCA technical success defined as the laser catheter crossing the entire length of the target lesion established by angiographic evidence of the catheter tip in the artery distal to the stenosis. RESULTS: We enrolled 114 patients who underwent contrast-enhanced ELCA-assisted PCI: 58% of the patients had acute coronary syndrome while the left anterior descending artery was the target vessel in 42.1% of cases. The target lesion was most commonly in-stent (56.2%). The 0.9 mm ELCA catheter tip was employed in 89.5% of cases. The most used frequency/fluency profile was 70/70 (39.5%). The use of contrast-enhanced ELCA was associated with high technical, procedural, and clinical success rates (97.4%, 93.7%, and 90.1%, respectively). CONCLUSIONS: The contrast-enhanced ELCA seems to be a safe and effective treatment option for the management of both de novo and in-stent-resistant coronary lesions.

3.
J Cardiovasc Electrophysiol ; 34(11): 2393-2397, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37792572

RESUMO

INTRODUCTION: Pulmonary vein isolation (PVI) with thermal energy is characterized by concomitant ablation of the surrounding ganglionated plexi (GP). Pulsed-field ablation (PFA) selectively targets the myocardium and seems associated with only negligible effects on the autonomic nervous system (ANS). However, little is known about the dynamic effects of PFA on the GP immediately after PVI. This study sought to investigate the degree and acute vagal modulation induced by the FarapulseTM PFA system during PVI compared with single-shot thermal ablation. METHODS: A total of 76 patients underwent first-time PVI with either FarapulseTM PFA (PFA group, n = 40) or cryoballoon ablation (thermal ablation group, n = 36) for paroxysmal atrial fibrillation (AF). The effect on the ANS in the two groups was assessed before and after PVI with extracardiac vagal stimulation (ECVS). To capture any transient effects of PFA on the ANS, in a subgroup of PFA patients ECVS was repeated at three predefined timepoints: (1) before PVI (T0); (2) immediately after PVI (T1); and (3) 10 min after the last energy application (T2). RESULTS: Despite similar baseline values, the vagal response induced by ECVS after PVI almost disappeared in the thermal ablation group but persisted in the PFA group (thermal group: 840 [706-1090] ms, p < .001 compared to baseline; PFA group: 11 466 [8720-12 293] ms, p = .70 compared to baseline). Intraprocedural vagal reactions (defined as RR increase >50%, transitory asystole, or atrioventricular block) occurred more frequently with PFA than thermal ablation (70% vs. 28%, p = .001). Moreover, heart rate 24 h post-PVI increased more with thermal ablation than with PFA (16.5 ± 9.0 vs. 2.6 ± 6.1 beats/min, p < .001). In the subgroup of PFA patients undergoing repeated ANS modulation assessment (n = 11), ECVS demonstrated that PFA determined a significant acute suppression of the vagal response immediately after PVI (p < .001 compared to baseline), which recovered almost completely within 10 min. CONCLUSION: PVI with the FarapulseTM PFA system is associated with only transitory and short-lasting vagal effects on the ANS which recover almost completely within a few minutes after ablation. The impact of this phenomenon on AF outcome needs to be further investigated.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Veias Pulmonares/cirurgia , Sistema Nervoso Autônomo/cirurgia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Nervo Vago/cirurgia , Frequência Cardíaca , Ablação por Cateter/efeitos adversos , Resultado do Tratamento
4.
J Cardiovasc Electrophysiol ; 34(8): 1781-1784, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37493490

RESUMO

INTRODUCTION: Cardiac involvement is common and may become clinically relevant in approximately 5%-10% of patients with systemic sarcoidosis. Although reduced left ventricular ejection fraction is a recognized predictor of mortality, recent studies have suggested an increased risk of ventricular arrhythmia (VAs) and sudden cardiac death (SCD) in patients with cardiac sarcoidosis (CS) and evidence of late gadolinium enhancement-cardiac magnetic resonance (LGE-CMR), irrespective of the underlying left ventricular systolic function. We performed a meta-analysis to assess the correlation between VAs/SCD and presence of LGE-CMR in CS patients. METHODS: We systematically searched Medline, Embase, and Cochrane electronic databases up to January 2, 2023, for studies enrolling patients with suspected or confirmed CS undergoing LGE-CMR. Clinical outcomes of interest included clinically relevant VAs, defined as sustained ventricular tachycardia, ventricular fibrillation, SCD, or aborted SCD during follow-up. The effect size was estimated using a random-effect model as risk ratio (RR) and relative 95% confidence interval (CI). RESULTS: A total of 14 studies fulfilled the selection criteria and were included in the final analysis. Among 1273 patients, LGE was detected in 465 (36.5%; Group LGE+). Males accounted for 45.2% (95% CI: 40.5%-55.7%) of the total population and the average age was 56.8 (95% CI: 52.7%-60.9) years. A total of 104 (22.3%) of 465 LGE+ patients experienced a clinically relevant VA, compared to 6 (0.7%) of 808 LGE- ones. LGE+ was associated with a ninefold increased risk in life-threatening VAs (22.3% vs. 0.7%; RR = 9.52; 95% CI [5.18-17.49]; p < .0001) compared to patients without LGE (heterogeneity I2 = 0%). CONCLUSION: In our meta-analysis, LGE+ in patients with CS was associated with a ninefold increased risk in life-threatening VAs compared to patients without LGE.


Assuntos
Miocardite , Sarcoidose , Humanos , Masculino , Pessoa de Meia-Idade , Arritmias Cardíacas/etiologia , Arritmias Cardíacas/complicações , Meios de Contraste , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/epidemiologia , Gadolínio , Imagem Cinética por Ressonância Magnética , Espectroscopia de Ressonância Magnética/efeitos adversos , Miocardite/complicações , Prognóstico , Medição de Risco , Fatores de Risco , Sarcoidose/complicações , Sarcoidose/diagnóstico por imagem , Volume Sistólico , Função Ventricular Esquerda
5.
Europace ; 25(12)2023 12 06.
Artigo em Inglês | MEDLINE | ID: mdl-38064697

RESUMO

AIMS: Catheter ablation (CA) is an established treatment for atrial fibrillation (AF). A computed tomography (CT) may be performed before ablation to evaluate the anatomy of pulmonary veins. The aim of this study is to investigate the prevalence of patients with coronary artery disease (CAD) detected by cardiac CT scan pre-ablation and to evaluate the impact of CAD and revascularization on outcomes after AF ablation. METHODS AND RESULTS: All consecutive patients with AF diagnosis, hospitalized at Universitair Ziekenhuis Brussel, Belgium, between 2015 and 2019, were prospectively screened for enrolment in the study. Inclusion criteria were (i) AF diagnosis, (ii) first procedure of AF ablation with cryoballoon CA, and (iii) contrast CT scan performed pre-ablation. A total of 576 consecutive patients were prospectively included and analysed in this study. At CT scan, 122 patients (21.2%) were diagnosed with CAD, of whom 41 patients (7.1%) with critical CAD. At survival analysis, critical CAD at CT scan was a predictor of atrial tachyarrhythmia (AT) recurrence during the follow-up, only in Cox univariate analysis [hazard ratio (HR) = 1.79] but was not an independent predictor in Cox multivariate analysis. At Cox multivariate analysis, independent predictors of AT recurrence were as follows: persistent AF (HR = 2.93) and left atrium volume index (HR = 1.04). CONCLUSION: In patients undergoing CT scan before AF ablation, critical CAD was diagnosed in 7.1% of patients. Coronary artery disease and revascularization were not independent predictors of recurrence; thus, in this patient population, AF ablation should not be denied and can be performed together with CAD treatment.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Doença da Artéria Coronariana , Veias Pulmonares , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/cirurgia , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/epidemiologia , Doença da Artéria Coronariana/cirurgia , Resultado do Tratamento , Átrios do Coração , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Recidiva
6.
Europace ; 26(1)2023 12 28.
Artigo em Inglês | MEDLINE | ID: mdl-38155611

RESUMO

AIMS: A novel sinus node (SN) sparing hybrid ablation for inappropriate sinus node tachycardia (IST)/postural orthostatic tachycardia syndrome (POTS) has been demonstrated to be an effective and safe therapeutic option in patients with symptomatic drug-resistant IST/POTS. The aim of this study was to evaluate the long-term rate of redo procedures after hybrid IST ablation and procedural strategy, outcomes and safety of redo procedures. METHODS AND RESULTS: All consecutive patients from 2015 to 2023 were prospectively enrolled in the UZ Brussel monocentric IST/POTS registry. They were analysed if the following inclusion criteria were fulfilled: 1) diagnosis of IST or POTS, 2) symptomatic IST/POTS refractory or intolerant to drugs, and 3) hybrid SN sparing ablation performed. The primary endpoint was redo procedure. The primary safety endpoint was pacemaker (PM) implantation. A total of 220 patients undergone to hybrid IST ablation were included, 185 patients (84.1%) were treated for IST and 61 patients (27.7%) for POTS.After a follow-up of 73.3 ± 16.2 months, 34 patients (15.4%) underwent a redo. A total of 23 patients (67.6%) had a redo for IST recurrence and 11 patients (32.4%) for other arrhythmias. Pacemaker implantation was performed in 21 patients (9.5%). Nine patients (4.1%) had no redo procedure and experienced sick sinus syndrome requiring a PM. Twelve patients (5.4%) received a PM as a shared therapeutic choice combined with SN ablation procedure. CONCLUSION: In a large cohort of patients the long-term free survival from redo procedure after hybrid IST ablation was 84.6% with a low PM implantation rate.


Assuntos
Ablação por Cateter , Taquicardia Sinusal , Humanos , Taquicardia Sinusal/diagnóstico , Taquicardia Sinusal/cirurgia , Taquicardia Sinusal/tratamento farmacológico , Nó Sinoatrial , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Frequência Cardíaca
7.
Europace ; 25(11)2023 11 02.
Artigo em Inglês | MEDLINE | ID: mdl-37889200

RESUMO

AIMS: Atrial fibrillation (AF) and chronic kidney disease (CKD) often coexist and share an increased risk of thrombo-embolism (TE). CKD concomitantly predisposes towards a pro-haemorrhagic state. Our aim was to evaluate the prognostic value of CKD in patients undergoing percutaneous left atrial appendage occlusion (LAAO). METHODS AND RESULTS: A total of 2124 consecutive AF patients undergoing LAAO were categorized into CKD stage 1+2 (n = 1089), CKD stage 3 (n = 796), CKD stage 4 (n = 170), and CKD stage 5 (n = 69) based on the estimated glomerular filtration rate at baseline. The primary endpoint included cardiovascular (CV) mortality, TE, and major bleeding. The expected annual TE and major bleeding risks were estimated based on the CHA2DS2-VASc and HAS-BLED scores. A non-significant higher incidence of major peri-procedural adverse events (1.7 vs. 2.3 vs. 4.1 vs. 4.3) was observed with worsening CKD (P = 0.14). The mean follow-up period was 13 ± 7 months (2226 patient-years). In comparison to CKD stage 1+2 as a reference, the incidence of the primary endpoint was significantly higher in CKD stage 3 (log-rank P-value = 0.04), CKD stage 4 (log-rank P-value = 0.01), and CKD stage 5 (log-rank P-value = 0.001). Left atrial appendage occlusion led to a TE risk reduction (RR) of 72, 66, 62, and 41% in each group. The relative RR of major bleeding was 58, 44, 51, and 52%, respectively. CONCLUSION: Patients with moderate-to-severe CKD had a higher incidence of the primary composite endpoint. The relative RR in the incidence of TE and major bleeding was consistent across CKD groups.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Insuficiência Renal Crônica , Acidente Vascular Cerebral , Humanos , Apêndice Atrial/cirurgia , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Prognóstico , Resultado do Tratamento , Estudos Retrospectivos , Hemorragia/induzido quimicamente , Insuficiência Renal Crônica/complicações , Insuficiência Renal Crônica/diagnóstico , Insuficiência Renal Crônica/epidemiologia , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Anticoagulantes/efeitos adversos
8.
Europace ; 26(1)2023 Dec 28.
Artigo em Inglês | MEDLINE | ID: mdl-38225176

RESUMO

AIMS: Left atrial appendage (LAA) imaging is critical during percutaneous occlusion procedures. 3D-intracardiac echocardiography (ICE) features direct visualization of LAA from multiple cross-sectional planes at a time. We aimed at reporting procedural success of 3D-ICE-guided LAA occlusion and the correlation between pre-procedural transoesophageal echocardiography (TEE) and intraprocedural 3D-ICE for LAA sizing. METHODS AND RESULTS: Among 274 patients undergoing left atrial appendage occlusion (LAAO) with a Watchman FLX, periprocedural ICE guidance was achieved via a commercially available 2D-ICE catheter (220 patients) or a novel (NUVISION™) 3D-ICE one (54 patients). Primary endpoint was a composite of procedural success and LAA sealing at follow-up TEE. Secondary endpoint was a composite of periprocedural device recapture/resizing plus presence of leaks ≥ 3 mm at follow-up TEE. 3D-ICE measurements of maximum landing zone correlated highly with pre-procedural TEE reference values [Pearson's: 0.94; P < 0.001; bias: -0.06 (-2.39, 2.27)]. The agreement between 3D-ICE-based device selection and final device size was 96.3% vs. 79.1% with 2D-ICE (P = 0.005). The incidence of the primary endpoint was 98.1% with 3D-ICE and 97.3% with 2D-ICE (P = 0.99). 2D-ICE patients had a trend towards a higher incidence of periprocedural device recapture/redeployment (31.5% vs. 44.5%; P = 0.09). The secondary endpoint occurred in 31.5% of 3D-ICE patients vs. 45.9% of 2D-ICE ones (P = 0.065). CONCLUSION: Intracardiac echocardiography-guided LAAO showed a very high success, with no major adverse events. A very high level of agreement for LAA sizing was found between pre-procedural TEE and periprocedural 3D-ICE. 3D-ICE performed significantly better than 2D-ICE for FLX size selection and may provide better guidance during device deployment.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Humanos , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Estudos Transversais , Resultado do Tratamento , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Fibrilação Atrial/complicações , Cateterismo Cardíaco , Ecocardiografia Transesofagiana/métodos , Ecocardiografia/métodos
9.
Pacing Clin Electrophysiol ; 46(5): 432-439, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-37036831

RESUMO

INTRODUCTION: Cardiac resynchronization therapy (CRT) reduces heart failure (HF) hospitalization and all-cause mortality in HF patients with left bundle branch block (LBBB). Biventricular pacing (BVP) is the gold standard for achieving CRT, but about 30%-40% of patients do not respond to BVP-CRT. Recent studies showed that left bundle branch pacing (LBBP) provided remarkable results in CRT. Therefore, we conducted a meta-analysis aiming to compare LBBP-CRT versus BVP-CRT in HF patients. METHODS: We systematically searched the electronic databases for studies published from inception to December 29, 2022 and focusing on LBBP-CRT versus BVP-CRT in HF patients. The primary endpoint was HF hospitalization. The effect size was estimated using a random-effect model as Risk Ratio (RR) and mean difference (MD). RESULTS: Ten studies enrolling 1063 patients met the inclusion criteria. Compared to BVP-CRT, LBBP-CRT led to significant reduction in HF hospitalization [7.9% vs.14.5%; RR: 0.60 (95%CI: 0.39-0.93); p = .02], QRSd [MD: 30.26 ms (95%CI: 26.68-33.84); p < .00001] and pacing threshold [MD: -0.60 (95%CI: -0.71 to -0.48); p < .00001] at follow up. Furthermore, LBBP-CRT improved LVEF [MD: 5.78% (95%CI: 4.78-6.77); p < .00001], the rate of responder [88.5% vs.72.5%; RR: 1.19 (95%CI: 1.07-1.32); p = .002] and super-responder [60.8% vs. 36.5%; RR: 1.56 (95%CI: 1.27-1.91); p < .0001] patients and the NYHA class [MD: -0.42 (95%CI: -0.71 to -0.14); p < .00001] compared to BVP-CRT. CONCLUSION: In HF patients, LBBP-CRT was superior to BVP-CRT in reducing HF hospitalization. Further significant benefits occurred within the LBBP-CRT group in terms of QRSd, LVEF, pacing thresholds, NYHA class and the rate of responder and super-responder patients.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Septo Interventricular , Humanos , Terapia de Ressincronização Cardíaca/métodos , Resultado do Tratamento , Sistema de Condução Cardíaco , Bloqueio de Ramo , Fascículo Atrioventricular , Eletrocardiografia/métodos
10.
Pacing Clin Electrophysiol ; 46(11): 1430-1439, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37812165

RESUMO

BACKGROUND: High-power-short-duration (HPSD) radiofrequency (RF) ablation is a viable alternative to low-power-long-duration (LPLD) RF for pulmonary vein isolation (PVI). Nevertheless, trials showed conflicting results regarding atrial fibrillation (AF) recurrences and few data concerning complications. Therefore, we conducted a meta-analysis of randomized trials comparing HPSD versus LPLD. METHODS: We systematically searched the electronic databases for studies published from inception to March 31, 2023 focusing on HPSD versus LPLD. The study endpoints were AF recurrence, procedural times and overall complications. RESULTS: Five studies enrolling 424 patients met the inclusion criteria (mean age 61.1 years; 54.3% paroxysmal AF; mean LVEF 58.2%). Compared to LPLD, HPSD showed a significantly lower AF recurrence rate [16.3% vs. 30,1%; RR: 0.54 (95% CI: 0.38-0.79); p = 0.001] at a mean 10.9 months follow-up. Moreover, HPSD led to a significant reduction in total procedural time [MD: -26.25 min (95%CI: -42.89 to -9.61); p = 0.002], PVI time [MD: -26.44 min (95%CI: -38.32 to -14.55); p < 0.0001], RF application time [MD: -8.69 min (95%CI: -11.37 to -6.01); p < 0.00001] and RF lesion number [MD: -7.60 (95%CI: -10.15 to -5.05); p < 0.00001]. No difference was found in either right [80.4% vs. 78.2%; RR: 1.04 (95% CI: 0.81-1.32); p = 0.77] or left [92.3% vs. 90.2%; RR: 1.02 (95% CI: 0.94-1.11); p = 0.58] first-pass isolation and overall complications [6% vs. 3.7%; RR: 1.45 (95%CI: 0.53-3.99); p = 0.47] between groups. CONCLUSION: In our metanalysis of randomized trials, HPSD ablation appeared to be associated to a significantly improved freedom from AF and shorter procedures, without increasing the risk of complications.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Humanos , Pessoa de Meia-Idade , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Criocirurgia/métodos , Veias Pulmonares/cirurgia , Ensaios Clínicos Controlados Aleatórios como Assunto , Recidiva , Fatores de Tempo , Resultado do Tratamento
11.
Pacing Clin Electrophysiol ; 46(8): 942-947, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37378419

RESUMO

INTRODUCTION: Cephalic vein cutdown (CVC) and axillary vein puncture (AVP) are both recommended for transvenous implantation of leads for cardiac implantable electronic devices (CIEDs). Nonetheless, it is still debated which of the two techniques has a better safety and efficacy profile. METHODS: We systematically searched Medline, Embase, and Cochrane electronic databases up to September 5, 2022, for studies that evaluated the efficacy and safety of AVP and CVC reporting at least one clinical outcome of interest. The primary endpoints were acute procedural success and overall complications. The effect size was estimated using a random-effect model as risk ratio (RR) and relative 95% confidence interval (CI). RESULTS: Overall, seven studies were included, which enrolled 1771 and 3067 transvenous leads (65.6% [n = 1162] males, average age 73.4 ± 14.3 years). Compared to CVC, AVP showed a significant increase in the primary endpoint (95.7 % vs. 76.1 %; RR: 1.24; 95% CI: 1.09-1.40; p = .001) (Figure 1). Total procedural time (mean difference [MD]: -8.25 min; 95% CI: -10.23 to -6.27; p < .0001; I2  = 0%) and venous access time (MD: -6.24 min; 95% CI: -7.01 to -5.47; p < .0001; I2  = 0%) were significantly shorter with AVP compared to CVC. No differences were found between AVP and CVC for incidence overall complications (RR: 0.56; 95% CI: 0.28-1.10; p = .09), pneumothorax (RR: 0.72; 95% CI: 0.13-4.0; p = .71), lead failure (RR: 0.58; 95% CI: 0.23-1.48; p = .26), pocket hematoma/bleeding (RR: 0.58; 95% CI: 0.15-2.23; p = .43), device infection (RR: 0.95; 95% CI: 0.14-6.60; p = .96) and fluoroscopy time (MD: -0.24 min; 95% CI: -0.75 to 0.28; p = .36). CONCLUSION: Our meta-analysis suggests that AVP may improve procedural success and reduce total procedural time and venous access time compared to CVC.


Assuntos
Veia Axilar , Venostomia , Masculino , Humanos , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Veia Axilar/cirurgia , Venostomia/métodos , Veia Subclávia , Punções/métodos , Coração
12.
Echocardiography ; 40(3): 217-226, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36748264

RESUMO

BACKGROUND: Early diagnosis of Coronary Artery Disease (CAD) plays a key role to prevent adverse cardiac events such as myocardial infarction and Left Ventricular (LV) dysfunction. Myocardial Work (MW) indices derived from echocardiographic speckle tracking data in combination with non-invasive blood pressure recordings seems promising to predict CAD even in the absence of impairments of standard echocardiographic parameters. Our aim was to compare the diagnostic accuracy of MW indices to predict CAD and to assess intra- and inter-observer variability of MW through a meta-analysis. METHODS: Electronic databases were searched for observational studies evaluating the MW indices diagnostic accuracy for predicting CAD and intra- and inter-observer variability of MW indices. Pooled sensitivity, specificity, and Summary Receiver Operating Characteristic (SROC) curves were assessed. RESULTS: Five studies enrolling 501 patients met inclusion criteria. Global Constructive Work (GCW) had the best pooled sensitivity (89%) followed by GLS (84%), Global Work Index (GWI) (82%), Global Work Efficiency (GWE) (80%), and Global Wasted Work (GWW) (75%). GWE had the best pooled specificity (78%) followed by GWI (75%), GCW (70%), GLS (68%), and GWW (61%). GCW had the best accuracy according to SROC curves, with an area under the curve of 0.86 compared to 0.84 for GWI, 0.83 for GWE, 0.79 for GLS, and 0.74 for GWW. All MW indices had an excellent intra- and inter-observer variability. CONCLUSIONS: GCW is the best MW index proving best diagnostic accuracy in the prediction of CAD with an excellent reproducibility.


Assuntos
Doença da Artéria Coronariana , Disfunção Ventricular Esquerda , Humanos , Reprodutibilidade dos Testes , Ecocardiografia , Miocárdio , Função Ventricular Esquerda , Volume Sistólico
13.
Curr Cardiol Rep ; 25(7): 641-648, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37269474

RESUMO

PURPOSE OF REVIEW: Myocarditis is an inflammation of the myocardium secondary to a variety of agents such as infectious pathogens, toxins, drugs, and autoimmune disorders. In our review, we provide an overview of miRNA biogenesis and their role in the etiology and pathogenesis of myocarditis, evaluating future directions for myocarditis management. RECENT FINDINGS: Advances in genetic manipulation techniques allowed to demonstrate the important role of RNA fragments, especially microRNAs (miRNAs), in cardiovascular pathogenesis. miRNAs are small non-coding RNA molecules that regulate the post-transcriptional gene expression. Advances in molecular techniques allowed to identify miRNA's role in pathogenesis of myocarditis. miRNAs are related to viral infection, inflammation, fibrosis, and apoptosis of cardiomyocytes, making them not only promising diagnostic markers but also prognostics and therapeutic targets in myocarditis. Of course, further real-world studies will be needed to assess the diagnostic accuracy and applicability of miRNA in the myocarditis diagnosis.


Assuntos
MicroRNAs , Miocardite , Humanos , MicroRNAs/genética , MicroRNAs/metabolismo , Miocardite/diagnóstico , Miocardite/genética , Miocárdio/patologia , Miócitos Cardíacos/patologia , Inflamação
14.
Sensors (Basel) ; 23(6)2023 Mar 16.
Artigo em Inglês | MEDLINE | ID: mdl-36991870

RESUMO

A diagnosis of Brugada syndrome (BrS) is based on the presence of a type 1 electrocardiogram (ECG) pattern, either spontaneously or after a Sodium Channel Blocker Provocation Test (SCBPT). Several ECG criteria have been evaluated as predictors of a positive SCBPT, such as the ß-angle, the α-angle, the duration of the base of the triangle at 5 mm from the r'-wave (DBT- 5 mm), the duration of the base of the triangle at the isoelectric line (DBT- iso), and the triangle base/height ratio. The aim of our study was to test all previously proposed ECG criteria in a large cohort study and to evaluate an r'-wave algorithm for predicting a BrS diagnosis after an SCBPT. We enrolled all patients who consecutively underwent SCBPT using flecainide from January 2010 to December 2015 in the test cohort and from January 2016 to December 2021 in the validation cohort. We included the ECG criteria with the best diagnostic accuracy in relation to the test cohort in the development of the r'-wave algorithm (ß-angle, α-angle, DBT- 5 mm, and DBT- iso.) Of the total of 395 patients enrolled, 72.4% were male and the average age was 44.7 ± 13.5 years. Following the SCBPTs, 24.1% of patients (n = 95) were positive and 75.9% (n = 300) were negative. ROC analysis of the validation cohort showed that the AUC of the r'-wave algorithm (AUC: 0.92; CI 0.85-0.99) was significantly better than the AUC of the ß-angle (AUC: 0.82; 95% CI 0.71-0.92), the α-angle (AUC: 0.77; 95% CI 0.66-0.90), the DBT- 5 mm (AUC: 0.75; 95% CI 0.64-0.87), the DBT- iso (AUC: 0.79; 95% CI 0.67-0.91), and the triangle base/height (AUC: 0.61; 95% CI 0.48-0.75) (p < 0.001), making it the best predictor of a BrS diagnosis after an SCBPT. The r'-wave algorithm with a cut-off value of ≥2 showed a sensitivity of 90% and a specificity of 83%. In our study, the r'-wave algorithm was proved to have the best diagnostic accuracy, compared with single electrocardiographic criteria, in predicting the diagnosis of BrS after provocative testing with flecainide.


Assuntos
Síndrome de Brugada , Humanos , Masculino , Adulto , Pessoa de Meia-Idade , Feminino , Síndrome de Brugada/diagnóstico , Bloqueadores dos Canais de Sódio/farmacologia , Bloqueadores dos Canais de Sódio/uso terapêutico , Flecainida , Estudos de Coortes , Eletrocardiografia , Algoritmos
15.
Pacing Clin Electrophysiol ; 45(12): 1409-1414, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36214206

RESUMO

INTRODUCTION: The implantable cardioverter defibrillator (ICD) has been demonstrated to successfully prevent sudden cardiac death (SCD) in children and young adults. A wide range of device-related complications/malfunctions have been described, which depend on the intrinsic design of the defibrillation system (transvenous-implantable cardioverter defibrillator [TV-ICD] vs. subcutaneous-implantable cardioverter defibrillator [S-ICD]). OBJECTIVE: To compare the device-related complications and inappropriate shocks with TV-ICD versus S-ICD. METHODS AND RESULTS: Electronic databases were queried for studies focusing on the prevention of SCD in children and young adults with TV-ICD or S-ICD. The effect size was estimated using a random-effect model as odds ratio (OR) and relative 95% confidence interval (CI). The primary endpoint was a composite of any device-related complications and inappropriate shocks. We identified a total of five studies including 236 patients (Group S-ICD: 76 patients; Group TV-ICD: 160 patients) with a mean follow-up time of 54.2 ± 24.9 months. S-ICD implantation contributed to a significant reduction in the risk of the primary endpoint of any device-related complications and inappropriate shocks (OR: 0.18; 95% CI: 0.05-0.73; p = .02). S-ICD was also associated with a significantly lower incidence of inappropriate shocks (OR: 0.28; 95% CI: 0.11-0.74; p = .01) and lead-related complications (OR: 0.18; 95% CI: 0.05-0.66; p = .01). A trend toward a higher risk of pocket complications (OR: 5.91; 95% CI: 0.98-35.63; p = .05) was recorded in patients with S-ICD. CONCLUSION: Children and young adults undergoing S-ICD implantation may have a lower risk of a composite of device-related complications and inappropriate shocks, compared to TV-ICD patients.


Assuntos
Morte Súbita Cardíaca , Desfibriladores Implantáveis , Criança , Humanos , Desfibriladores Implantáveis/efeitos adversos , Adolescente , Morte Súbita Cardíaca/prevenção & controle
16.
J Electrocardiol ; 73: 52-54, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35660341

RESUMO

Atrial fibrillation (AF) is the most common cardiac arrhythmia in adults with substantial morbidity and mortality. The diagnosis of AF is established by electrocardiogram showing heart rhythm without clear P waves with irregular RR intervals. The electrocardiographic diagnosis of AF is not always easy and can still hide pitfalls even for the most experienced cardiologist. We present the case of an 86 years old patient admitted to our hospital for Covid-19 infection affected by dilated cardiomyopathy with an electrocardiogram showing a non-specific intraventricular conduction delay mimicking sinus rhythm in the presence of AF.


Assuntos
Fibrilação Atrial , COVID-19 , Adulto , Idoso de 80 Anos ou mais , Fibrilação Atrial/diagnóstico , Eletrocardiografia , Bloqueio Cardíaco , Ventrículos do Coração , Humanos
17.
J Electrocardiol ; 74: 46-53, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35964522

RESUMO

INTRODUCTION: Atrial fibrillation (AF) is the main cardiac cause of stroke, but it frequently remains undetected. In patients with cryptogenic stroke an Holter electrocardiogram (ECG) monitoring for AF is recommended. OBJECTIVE: To evaluate the prognostic role of Non-Conducted Premature Atrial Complexes (ncPACs) recorded on Holter ECG. METHODS: We prospectively enrolled consecutive patients admitted to the Stroke Unit of our hospital with a diagnosis of cryptogenic stroke between December 2018 and January 2020; all patients underwent 24-h Holter ECG monitoring during hospitalization. Two follow-up visits were scheduled, including a 24-h Holter ECG at 3 and 6 months to detect AF. RESULTS: Among 112 patients, 58% were male with an average age of 72.2 ± 12.2 years. At follow-up, AF was diagnosed in 21.4% of the population. The baseline 24-h Holter ECG burden of ncPACs and Premature Atrial Complexes (PACs) was higher in patients with AF detected on follow-up (13.5 vs 2, p = 0.001; 221.5 vs 52; p = 0.01). ROC analysis showed that ncPACs had the best diagnostic accuracy in predicting AF (AUC:0.80; 95% CI 0.68-0.92). Cut-off value of ≥7 for ncPACs burden showed the highest accuracy with sensitivity of 62.5% and specificity 97.7% to predict AF onset at follow-up. Moreover, at multivariate Cox-proportional hazard analysis ncPACs burden ≥7 was a powerful independent predictor of AF onset (HR 12.4; 95% CI 4.8-32.8; p < 0.0001). CONCLUSIONS: NcPACs burden ≥7 represents a new predictor of AF that could guide the screening of this arrhythmia in cryptogenic stroke patients.


Assuntos
Fibrilação Atrial , AVC Isquêmico , Acidente Vascular Cerebral , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Feminino , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Eletrocardiografia , Acidente Vascular Cerebral/etiologia
18.
Monaldi Arch Chest Dis ; 90(2)2020 Apr 28.
Artigo em Inglês | MEDLINE | ID: mdl-32344995

RESUMO

Since its introduction right ventricular apical (RVA) pacing has been the mainstay in cardiac pacing. However, in recent years there has been an upsurge of interest in permanent His bundle pacing (HBP), given the scientific evidence of the harmful role of dyssynchronous ventricular activation, induced by RVA pacing, in promoting the onset of heart failure and atrial fibrillation. After an intermediate period in which attention was focused on algorithms aimed at minimizing ventricular pacing, with partially inadequate and harmful results, scientific attention shifted to HBP, which proved to ensure a physiological electro-mechanical activation of the ventricles. The encouraging results obtained have allowed the introduction of HBP in recent guidelines for cardiac pacing in patients with bradicardia and cardiac conduction delay. Recent studies have also demonstrated the potential of HBP in patients with left bundle branch block and heart failure. HBP is promising as an attractive way to achieve physiological stimulation in patients with an indication for cardiac resynchronization therapy (CRT). Comparative studies of HB-CRT and biventricular pacing have shown similar results in numerically modest cohorts, although HB-CRT has been shown to promote better ventricular electrical resynchronization as demonstrated by a greater QRS narrowing. A widespread use of this pacing tecnique also depends on improvements in technology, as well as further validation of effectiveness in large randomised clinical trials.


Assuntos
Fascículo Atrioventricular/fisiopatologia , Bloqueio de Ramo/fisiopatologia , Terapia de Ressincronização Cardíaca/métodos , Ventrículos do Coração/fisiopatologia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/terapia , Bradicardia/fisiopatologia , Bloqueio de Ramo/terapia , Cateterismo Cardíaco/métodos , Doença do Sistema de Condução Cardíaco/fisiopatologia , Eletrocardiografia/métodos , Insuficiência Cardíaca/fisiopatologia , Humanos , Avaliação de Resultados em Cuidados de Saúde
19.
Monaldi Arch Chest Dis ; 89(1)2019 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-30968659

RESUMO

Heart failure is a widespread disease in the western world whose incidence and prevalence are constantly increasing, mainly involving the more advanced age groups. Cardiac resynchronization therapy (CRT) has been shown able to reduce sudden cardiac death and all-cause mortality in patients with heart failure and reduced ejection fraction. Elderly patients are generally under-represented in the clinical trials aimed to evaluate the efficacy of CRT and, chiefly, of implantable cardiac defibrillator (ICD). The simultaneous presence of confounding factors such as co-morbidities, polypharmacy, changes in cognitive status, frailty, are the most important causes for the exclusion of subjects of advanced age from RCTs on the ICD or CRT implant. Current guidelines do not suggest any upper age limit for ICD and CRT but recommend avoiding their use in frail older patients with a life expectancy of less than 1 year. Data from the literature show that CRT has equal dignity in both the elderly and the young, in fostering effective functional and morphological improvements, also suggesting that, in older patients, CRT-D may have little practical value compared to CRT-P given the low incidence of arrhythmic death. Nevertheless, it is necessary to develop RCTs that consider aspects of the elderly patient in relation to CRT such as functional, cognitive and nutritional status.


Assuntos
Terapia de Ressincronização Cardíaca/métodos , Desfibriladores Implantáveis , Insuficiência Cardíaca/terapia , Fatores Etários , Idoso , Morte Súbita Cardíaca/prevenção & controle , Idoso Fragilizado , Insuficiência Cardíaca/epidemiologia , Insuficiência Cardíaca/fisiopatologia , Humanos , Guias de Prática Clínica como Assunto , Ensaios Clínicos Controlados Aleatórios como Assunto/métodos
20.
Monaldi Arch Chest Dis ; 87(2): 855, 2017 07 18.
Artigo em Inglês | MEDLINE | ID: mdl-28967721

RESUMO

Over the past few decades, the progressive aging of the population combined with the resulting increase in cardiovascular disease and the marked improvement of technologies applied to surgery justify the marked increase of the elderly patients requiring cardiovascular surgery. This claims a highly skilled perioperative management, which should be aimed at treating cardiac disease without increasing risk of hospitalization-related harmful events. Current preoperative assessment for cardiac surgery, such as the European System for Cardiac Operative Risk Evaluation II (EUROSCORE II) and the Society of Thoracic Surgeons (STS) risk score, are limited in their ability to predict perioperative outcomes in older patients.  This is because patients' chronological age should not be considered as the only tool to identify the surgical risk. In recent years, indeed, several studies have highlighted the role of frailty syndrome in determining the prognosis of elderly patients undergoing cardiac surgery. Particularly, some functional aspects, such as gait speed seem to have a high sensitivity and specificity in this regard. Therefore, further research is needed in order not only to identify a unique, fast and easy to use tool aimed to recognize frailty syndrome, but chiefly resulting able to give us information about the effectiveness of focused preoperative interventions. Finally, we need to have scientific data on the role that surgical, percutaneous and transcatheter procedures have on outcome in elderly patients in terms of perioperative mortality, postoperative quality of life and regarding the possible reversibility of frailty. Cardiovascular surgery is to date a "moving target", due to changing face of patients and changing face of technical requirements and perioperative management should reflect such changes.


Assuntos
Procedimentos Cirúrgicos Cardíacos/mortalidade , Cardiopatias/mortalidade , Assistência Perioperatória/mortalidade , Idoso , Idoso de 80 Anos ou mais , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Procedimentos Cirúrgicos Cardíacos/psicologia , Idoso Fragilizado , Fragilidade , Avaliação Geriátrica , Hospitalização/estatística & dados numéricos , Humanos , Comunicação Interdisciplinar , Assistência Perioperatória/normas , Complicações Pós-Operatórias/mortalidade , Prognóstico , Qualidade de Vida , Medição de Risco , Fatores de Risco
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa