Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
País como assunto
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
2.
BMJ Open ; 7(5): e015560, 2017 05 29.
Artigo em Inglês | MEDLINE | ID: mdl-28554935

RESUMO

OBJECTIVE: To assess the diagnostic accuracy of peripheral capillary oxygen saturation (SpO2) while breathing room air for 5 min (the 'Air-Test') in detecting postoperative atelectasis. DESIGN: Prospective cohort study. Diagnostic accuracy was assessed by measuring the agreement between the index test and the reference standard CT scan images. SETTING: Postanaesthetic care unit in a tertiary hospital in Spain. PARTICIPANTS: Three hundred and fifty patients from 12 January to 7 February 2015; 170 patients scheduled for surgery under general anaesthesia who were admitted into the postsurgical unit were included. INTERVENTION: The Air-Test was performed in conscious extubated patients after a 30 min stabilisation period during which they received supplemental oxygen therapy via a venturi mask. The Air-Test was defined as positive when SpO2 was ≤96% and negative when SpO2 was ≥97%. Arterial blood gases were measured in all patients at the end of the Air-Test. In the subsequent 25 min, the presence of atelectasis was evaluated by performing a CT scan in 59 randomly selected patients. MAIN OUTCOME MEASURES: The primary study outcome was assessment of the accuracy of the Air-Test for detecting postoperative atelectasis compared with the reference standard. The secondary outcome was the incidence of positive Air-Test results. RESULTS: The Air-Test diagnosed postoperative atelectasis with an area under the receiver operating characteristic curve of 0.90 (95% CI 0.82 to 0.98) with a sensitivity of 82.6% and a specificity of 87.8%. The presence of atelectasis was confirmed by CT scans in all patients (30/30) with positive and in 5 patients (17%) with negative Air-Test results. Based on the Air-Test, postoperative atelectasis was present in 36% of the patients (62 out of 170). CONCLUSION: The Air-Test may represent an accurate, simple, inexpensive and non-invasive method for diagnosing postoperative atelectasis. TRIAL REGISTRATION: NCT02650037.


Assuntos
Ar/análise , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/terapia , Atelectasia Pulmonar/diagnóstico , Atelectasia Pulmonar/terapia , Adulto , Idoso , Anestesia Geral/efeitos adversos , Gasometria , Reações Falso-Negativas , Feminino , Humanos , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Oximetria , Oxigenoterapia , Projetos Piloto , Complicações Pós-Operatórias/etiologia , Estudos Prospectivos , Atelectasia Pulmonar/etiologia , Sensibilidade e Especificidade , Espanha , Centros de Atenção Terciária , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa