Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Int Ophthalmol ; 44(1): 112, 2024 Feb 26.
Artigo em Inglês | MEDLINE | ID: mdl-38407686

RESUMO

PURPOSE: To evaluate and compare the visual outcomes of an enhanced monofocal intraocular lens (IOL) with two different monofocal IOLs. SETTING: Eye Clinic, Department of Medicine, Surgery and Health Sciences, University of Trieste, Trieste, Italy. DESIGN: Prospective, single-center, single-masked, randomized controlled clinical study. METHODS: The study included patients undergoing phacoemulsification and IOL implantation. Patients were consecutively randomized by block randomization and assigned in a 1:1:1 allocation ratio to three study arms to bilaterally receive Tecnis Eyhance™ (model ICB00) or Tecnis® monofocal 1-piece (model PCB00) or Clareon® monofocal (model CNA0T0), respectively. Monocular and binocular (both corrected and uncorrected) visual acuities for far, intermediate and near were registered and compared among groups at 3 months. To track changes in patient quality of life, the Catquest-9SF questionnaire was administered to each patient before and after cataract extraction. RESULTS: Ninety patients (30 for each group) were enrolled. At 3 months follow-up, statistically significant differences for intermediate visual acuities were found between the three groups. Nonstatistically significant differences were observed for distance visual acuities and the changes in Catquest-9SF scores. CONCLUSION: Tecnis Eyhance™ provided better results in intermediate visual outcomes without adverse effects on patients' quality of life.


Assuntos
Lentes Intraoculares , Satisfação do Paciente , Humanos , Estudos Prospectivos , Qualidade de Vida , Olho Artificial
2.
Klin Monbl Augenheilkd ; 240(4): 449-455, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37164442

RESUMO

BACKGROUND: It is known that cataract extraction is associated with a significant reduction in intraocular pressure, especially in narrow angled eyes; however, the modifications of anterior segment parameters associated with this phenomenon have still not been completely defined. The purpose of this study was to evaluate changes in anterior segment anatomy and intraocular pressure after cataract surgery in non-glaucomatous eyes. METHODS AND MATERIAL: This retrospective case series study included 64 eyes of 64 consecutive patients who underwent phacoemulsification with intraocular lens implantation. Anterior segment parameters and intraocular pressure were assessed and compared before and 6 months after surgery. Anterior segment imaging was performed using Casia SS-1000 anterior segment optical coherence tomography (Tomey, Nagoya, Japan). Anterior segment measurements included anterior chamber depth, anterior chamber width, anterior chamber volume, angle opening distance at 500 µm anterior to the scleral spur, angle recess area 750 µm from the scleral spur, lens vault, trabecular iris space area at 500 µm from the scleral spur, and trabecular iris angle at 500 µm from the scleral spur. Intraocular pressure was measured using the Goldmann applanation tonometer (Model AT 900 C/M, Haag-Streit, Bern, Switzerland). Anterior segment parameters and the relationship of changes in intraocular pressure were also evaluated. RESULTS: All anterior segment parameters increased significantly after surgery (p < 0.05). Both angle opening distance at 500 µm anterior to the scleral spur and anterior chamber depth changes were positively correlated with the preoperative lens vault. The mean intraocular pressure significantly decreased from 14.91 mmHg (± 2.8 SD) to 12.91 mmHg (± 3.13 SD) (p < 0.001). Changes in intraocular pressure correlated negatively with values for the width of the preoperative anterior chamber (r = - 0.533; p = 0.001). CONCLUSION: Cataract surgery led to significant widening of the anterior chamber angle and lowering of intraocular pressure. Further investigations are needed to better understand whether anterior chamber width may be a new independent predictive factor for reduction in postoperative intraocular pressure.


Assuntos
Catarata , Oftalmopatias , Glaucoma de Ângulo Fechado , Humanos , Pressão Intraocular , Estudos Retrospectivos , Implante de Lente Intraocular , Tonometria Ocular , Câmara Anterior/diagnóstico por imagem , Iris , Tomografia de Coerência Óptica , Segmento Anterior do Olho/diagnóstico por imagem
3.
Case Rep Ophthalmol ; 15(1): 303-309, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38590942

RESUMO

Introduction: The production of ultrasonic energy during phacoemulsification is associated with heat generation that could damage ocular tissues, particularly at the corneoscleral wound site. Case Presentation: This study presents an 89-year-old patient with senile hypermature cataract and Fuchs endothelial dystrophy developing severe thermal corneoscleral injury during phacoemulsification. At presentation, visual acuity was finger count at 40 cm and there was a 1 × 2-mm area of corneal melting at the corneal tunnel with diffuse corneal oedema. After 1 month, a temporal circular corneal patch graft was applied to the corneal burn. A penetrating keratoplasty was performed 16 months after the first surgery. Conclusion: Corneal surgery, including lamellar patch grafts and full-thickness penetrating grafts, could be used, when necessary, to restore the cornea's integrity. These procedures could eliminate corneal scarring, decrease astigmatism, and improve vision in patients with phacoemulsification burns.

4.
Surv Ophthalmol ; 69(3): 427-434, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38309315

RESUMO

In phakic patients Descemet stripping automated endothelial keratoplasty (DSAEK) or Descemet membrane endothelial keratoplasty (DMEK) are frequently combined with phacoemulsification and intraocular lens (IOL) implantation (triple procedure). This surgery might cause a refractive shift difficult to predict. Early DMEK and DSAEK results have shown a tendency toward a hyperopic shift. Myopic postoperative refraction is typically intended to correct this postoperative refractive defect and to bring all eyes as close to emmetropia as possible. We sought to understand the mechanism underlying the hyperopization and to identify predictive factors for poorer refractive outcomes, the most suitable target refraction and IOL calculation methods in patients undergoing combined cataract extraction and lamellar endothelial corneal transplantation (DSAEK or DMEK) for endothelial dysfunctions. Of the 407 articles analyzed, only 18 were included in the analysis. A myopic target between -0.50 D and -0.75 was the most common (up to -1.50 for DSAEK triple procedures), even though no optimum target was found. Hyperopic surprises appeared more frequently in corneas that were flatter in the center than in the periphery (oblate posterior profile). Among the numerous IOL calculation formulas, there was no apparent preference.


Assuntos
Ceratoplastia Endotelial com Remoção da Lâmina Limitante Posterior , Implante de Lente Intraocular , Refração Ocular , Humanos , Refração Ocular/fisiologia , Ceratoplastia Endotelial com Remoção da Lâmina Limitante Posterior/métodos , Implante de Lente Intraocular/métodos , Facoemulsificação/métodos , Acuidade Visual/fisiologia
5.
Eur J Ophthalmol ; : 11206721241245743, 2024 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-38576315

RESUMO

PURPOSE: To analyse the long anatomical and functional outcome of a subgroup of the DICAT II study cohort, consisting of 26 patients undergoing cataract surgery and withdrawn from the study for a clinically significant worsening of early diabetic macular edema (DME). MATERIALS: Patients who underwent cataract surgery and withdrawn from the DICAT II study for a clinically significant worsening of early DME with at least 12 months follow-up after the dropout. The study population was divided into two groups according to the clinical evaluation at one-year follow-up: ongoing treatment patients for DME (Treatment group, TG) and patients no longer treated (Non Treatment group, NTG). RESULTS: Central foveal thickness (CFT) at baseline and dropout time were higher in TG than in the NTG, with a statistically significant difference (p < 0.05). In addition, TG patients reported a higher levels of glycated hemoglobin at time baseline compared to NTG patients (7.81 ± 1.15 vs 7.02 ± 0.56; p = 0.048). The linear regression analysis demonstrated a statistically significant relationship between the visual acuity and the ongoing treatment group at one-year follow-up (p = 0.042). CONCLUSION: The study provides parameters to be considered when assessing the risk of developing persistent DME after cataract surgery in diabetic patients. In particular, CFT at baseline and dropout time have been reported to be an effective and predictable OCT biomarkers when evaluating DME progression. During the evaluation of the systemic disease, similar results were found for the glycated hemoglobin at baseline.

6.
Surv Ophthalmol ; 67(3): 817-829, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34606818

RESUMO

Artificial intelligence (AI)-based applications exhibit the potential to improve the quality and efficiency of patient care in different fields, including cataract management. A systematic review of the different applications of AI-based software on all aspects of a cataract patient's management, from diagnosis to follow-up, was carried out in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. All selected articles were analyzed to assess the level of evidence according to the Oxford Centre for Evidence-Based Medicine 2011 guidelines, and the quality of evidence according to the Grading of Recommendations Assessment, Development and Evaluation system. Of the articles analyzed, 49 met the inclusion criteria. No data synthesis was possible for the heterogeneity of available data and the design of the available studies. The AI-driven diagnosis seemed to be comparable and, in selected cases, to even exceed the accuracy of experienced clinicians in classifying disease, supporting the operating room scheduling, and intraoperative and postoperative management of complications. Considering the heterogeneity of data analyzed, however, further randomized controlled trials to assess the efficacy and safety of AI application in the management of cataract should be highly warranted.


Assuntos
Inteligência Artificial , Catarata , Humanos
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa