1.
Chem Soc Rev ; 47(23): 8721-8743, 2018 Nov 26.
Artigo em Inglês | MEDLINE | ID: mdl-30298880

RESUMO

Rechargeable redox flow batteries are being developed for medium and large-scale stationary energy storage applications. Flow batteries could play a significant role in maintaining the stability of the electrical grid in conjunction with intermittent renewable energy. However, they are significantly different from conventional batteries in operating principle. Recent contributions on flow batteries have addressed various aspects, including electrolyte, electrode, membrane, cell design, etc. In this review, we focus on the less-discussed practical aspects of devices, such as flow fields, stack and design considerations for developing high performance large-scale flow batteries. Finally, we provide suggestions for further studies on developing advanced flow batteries and large-scale flow battery stacks.

2.
J Power Sources ; 196(2): 820-826, 2011 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-20953345

RESUMO

The objective of this work was to demonstrate a micro-fabricated hydrogen storage module for micro-power systems. Hydrogen storage materials were developed as thin-film inks to be compatible with an integrated manufacturing process. Performance and durability of storage modules were evaluated. Further, applications were demonstrated for a nickel-hydrogen battery and a micro-fabricated hydrogen-air PEM fuel cell. The ink making process, in which polymer binders and solvents were added to the palladium-treated alloys, slightly decreased the storage capacities, but had little effect on the activation properties of the treated alloys. After 5000 absorption/desorption cycles under hydrogen, the hydrogen storage capacities of the thin-film inks remained high. Absorption/desorption behavior of the ink was tested in the environment of a new type nickel-hydrogen battery, in which it would in contact with 26wt% KOH solution, and the ink showed no apparent degradation. Storage modules were used as the successfully as hydrogen source for PEM fuel cell.

3.
J Power Sources ; 196(2): 827-834, 2011 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-20967132

RESUMO

The objective of this work was to develop a hydrogen storage module for onboard electrical power sources suitable for use in micro power systems and micro-electro-mechanical systems (MEMS). Hydrogen storage materials were developed as thin-film inks to be compatible with an integrated manufacturing process. Important design aspects were (a) ready activation at sub-atmospheric hydrogen pressure and room temperature and (b) durability, i.e. capable of hundreds of absorption/desorption cycles and resistance to deactivation on exposure to air. Inks with palladium-treated intermetallic hydrogen storage alloys were developed and are shown here to be compatible with a thin-film micro-fabrication process. These hydrogen storage modules absorb hydrogen readily at atmospheric pressure, and the absorption/desorption rates remained fast even after the ink was exposed to air for 47 weeks.

4.
IEEE Trans Neural Syst Rehabil Eng ; 27(5): 836-845, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30951474

RESUMO

Direct current (DC) nerve block has been shown to provide a complete block of nerve conduction without unwanted neural firing. Previous work shows that high capacitance electrodes can be used to safely deliver a DC block. Another way of delivering DC safely is through a separated interface nerve electrode (SINE), such that any reactive species that are generated by the passage of DC are contained in a vessel away from the nerve. This design has been enhanced by using a high capacitance carbon "slurry" as the electrode in the external vessel to extend the capacity of the electrode (CSINE). With this new design, it was possible to provide 50 min of continuous nerve block without recharge while still maintaining complete recovery of neural signals. Up to 46 C of charge delivery was applied for a total of 4 h of nerve block with complete recovery. Because of the extended delivery time, it was possible to explore several properties of DC block that would not be revealed without the capability of a long-duration continuous block. It was possible to achieve complete block at lower values of DC if the block was applied for a longer period of time. Depending on the amount of charge applied during the block, the recovery was delayed for a period of time before complete force recovery was restored. These new properties provide novel techniques for device development to optimize charge delivery time and device powering concerns.


Assuntos
Estimulação Elétrica/instrumentação , Eletrodos , Bloqueio Nervoso , Condução Nervosa , Algoritmos , Animais , Materiais Biocompatíveis , Bioengenharia , Carbono , Desenho de Equipamento , Grafite , Músculo Esquelético/inervação , Músculo Esquelético/fisiologia , Ratos , Ratos Sprague-Dawley , Nervo Isquiático
SELEÇÃO DE REFERÊNCIAS