Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Langmuir ; 36(1): 37-46, 2020 01 14.
Artigo em Inglês | MEDLINE | ID: mdl-31865701

RESUMO

Enzymes conjugated to nanomaterials are used in the design of various biotechnologies. In the development of biosensors, surface modifications with the enzyme glucose oxidase (GOx) serve to aid the detection of blood glucose. In order to optimize sensor effectiveness, the enzyme tertiary structure needs to be preserved upon immobilization to retain the enzyme's catalytic activity. Because of the nature of GOx, it suffers from a tendency to denature when immobilized at a solid surface; hence, methods to optimize enzyme stability are of great importance. Here, we introduce the study of the interaction of GOx to the highly curved surface of 20 nm gold nanoparticles (AuNP) with an absorbed monolayer coating of enzyme as determined by flocculation assays and quantification of immobilized GOx at the nanoparticle surface. Enzyme crowding was determined by comparing the number of enzymes that bind to how many can physically fit. These measurements show how placing a monolayer of enzyme where the enzyme spreads thin at the AuNP surface still provides stable catalytic performance of up to 14 days compared to enzymes free in solution. Moreover, by the increasing enzyme density via increasing the amount of GOx present in solution during the GOx/AuNP conjugation step creates a molecularly crowded environment at the highly curved nanoparticle surface. This limits the size of the enzyme footprint for attachment and shows that the activity per enzyme can be enhanced up to 300%. This is of great importance for implementing stable and sensitive sensor technologies that are constructed by enzyme-based nanoparticle scaffolds. Here, we show by using the conditions that maintain GOx structure and function when limiting the enzyme coating to an ultrathin layer, the design and construction of an ultrafast responding diagnostic sensor technology for glucose can be achieved, which is crucial for monitoring rapid fluctuations of, for instance, glucose in the brain.


Assuntos
Glucose Oxidase/química , Aspergillus niger/enzimologia , Estabilidade Enzimática , Glucose Oxidase/metabolismo , Ouro/química , Nanopartículas Metálicas/química
2.
J Am Chem Soc ; 141(44): 17507-17511, 2019 11 06.
Artigo em Inglês | MEDLINE | ID: mdl-31644274

RESUMO

Analytical tools for quantitative measurements of glutamate, the principal excitatory neurotransmitter in the brain, are lacking. Here, we introduce a new enzyme-based amperometric sensor technique for the counting of glutamate molecules stored inside single synaptic vesicles. In this method, an ultra-fast enzyme-based glutamate sensor is placed into a solution of isolated synaptic vesicles, which stochastically rupture at the sensor surface in a potential-dependent manner at a constant negative potential. The continuous amperometric signals are sampled at high speed (10 kHz) to record sub-millisecond spikes, which represent glutamate release from single vesicles that burst open. Glutamate quantification is achieved by a calibration curve that is based on measurements of glutamate release from vesicles pre-filled with various glutamate concentrations. Our measurements show that an isolated single synaptic vesicle encapsulates about 8000 glutamate molecules and is comparable to the measured exocytotic quantal glutamate release in amperometric glutamate sensing in the nucleus accumbens of mouse brain tissue. Hence, this new methodology introduces the means to quantify ultra-small amounts of glutamate and to study synaptic vesicle physiology, pathogenesis, and drug treatments for neuronal disorders where glutamate is involved.


Assuntos
Aminoácido Oxirredutases/química , Técnicas Eletroquímicas/métodos , Ácido Glutâmico/análise , Neurotransmissores/análise , Vesículas Sinápticas/química , Animais , Química Encefálica , Carbono/química , Técnicas Eletroquímicas/instrumentação , Eletrodos , Ácido Glutâmico/química , Ouro/química , Masculino , Nanopartículas Metálicas/química , Camundongos Endogâmicos C57BL , Neurotransmissores/química , Ratos Sprague-Dawley , Lipossomas Unilamelares/química
3.
Anal Bioanal Chem ; 410(6): 1775-1783, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29279991

RESUMO

To immobilize enzymes at the surface of a nanoparticle-based electrochemical sensor is a common method to construct biosensors for non-electroactive analytes. Studying the interactions between the enzymes and nanoparticle support is of great importance in optimizing the conditions for biosensor design. This can be achieved by using a combination of analytical methods to carefully characterize the enzyme nanoparticle coating at the sensor surface while studying the optimal conditions for enzyme immobilization. From this analytical approach, it was found that controlling the enzyme coverage to a monolayer was a key factor to significantly improve the temporal resolution of biosensors. However, these characterization methods involve both tedious methodologies and working with toxic cyanide solutions. Here we introduce a new analytical method that allows direct quantification of the number of immobilized enzymes (glucose oxidase) at the surface of a gold nanoparticle coated glassy carbon electrode. This was achieved by exploiting an electrochemical stripping method for the direct quantification of the density and size of gold nanoparticles coating the electrode surface and combining this information with quantification of fluorophore-labeled enzymes bound to the sensor surface after stripping off their nanoparticle support. This method is both significantly much faster compared to previously reported methods and with the advantage that this method presented is non-toxic. Graphical abstract A new analytical method for direct quantification of the number of enzymes immobilized at the surface of gold nanoparticles covering a glassy carbon electrode using anodic stripping and fluorimetry.


Assuntos
Aspergillus niger/enzimologia , Enzimas Imobilizadas/análise , Corantes Fluorescentes/análise , Glucose Oxidase/análise , Ouro/química , Nanopartículas Metálicas/química , Técnicas Biossensoriais , Eletrodos , Espectrometria de Fluorescência
4.
Foods ; 13(4)2024 Feb 19.
Artigo em Inglês | MEDLINE | ID: mdl-38397597

RESUMO

Determination of Occidental pear (Pyrus communis) ripening is difficult because the appearance of Occidental pears does not change significantly during the ripening process. Occidental pears at different ripening stages release different volatile organic compounds (VOCs), which can be used to determine fruit ripeness non-destructively and rapidly. In this study, VOCs were detected using proton-transfer-reaction mass spectrometry (PTR-MS). Notably, data were acquired within 1 min. Occidental pears harvested at five separate times were divided into three ripening stages: unripe, ripe, and overripe. The results showed that the composition of VOCs differed depending on the ripening stage. In particular, the concentrations of esters and terpenes significantly increased during the overripe stage. Three ripening stages were clearly discriminated by heatmap clustering and principal component analysis (PCA). This study provided a rapid and non-destructive method to evaluate the ripening stages of Occidental pears. The result can help fruit farmers to decide the optimum harvest time and hence reduce their economic losses.

5.
Methods Mol Biol ; 2565: 261-279, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36205900

RESUMO

The fusion of vesicles and exocytosis release of neurotransmitters into the extracellular space for detection and chemical signal decoding by neighboring cells is the key process in neuronal communication. It is important to understand what regulates exocytosis because the amount of neurotransmitters released into the synaptic cleft has a direct impact on brain function such as cognition learning and memory as well as on brain malfunctions. Much success in molecular biology can be credited for the existence of simplified model systems. Therefore, for gaining deeper insights into the details of exocytosis and what controls vesicle-mediated neurotransmission, functional artificial cells for exocytosis have been developed that can be used for studying various biophysical aspects and roles of molecules affecting exocytosis, which is difficult to study in living cells. Here, we describe the design and fabrication of specific artificial cell models and how chemical measurements at these cells can be implemented for probing dynamics of the exocytosis fusion pore and its effect on the regulation of neurochemical release. We introduce bottom-up synthetic methods for constructing model cells using protein-free giant unilamellar vesicles (GUV) as starting material, which allows further tuning of molecular complexity in a manner that is not possible in living cells and therefore can be used for dissecting the role of essential molecular components affecting the exocytosis process. The experimental setup uses microscopy video recording, micromanipulation and microelectroinjection techniques, and amperometry detection to study neurotransmitter release from these cells mimicking exocytosis.


Assuntos
Células Artificiais , Transporte Biológico , Exocitose/fisiologia , Fusão de Membrana , Neurotransmissores , Lipossomas Unilamelares
6.
Pharmacol Biochem Behav ; 201: 173113, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33444597

RESUMO

To understand the correlation between animal behaviors and the underlying neuronal circuits, it is important to monitor and record neurotransmission in the brain of freely moving animals. With the development of fiber photometry, based on genetically encoded biosensors, and novel electrochemical biosensors, it is possible to measure some key neuronal transmission events specific to cell types or neurotransmitters of interest with high temporospatial resolution. This review discusses the recent advances and achievements of these two techniques in the study of neurotransmission in animal models and how they can be used to complement other techniques in the neuroscientist's toolbox.


Assuntos
Comportamento Animal/fisiologia , Mapeamento Encefálico/métodos , Encéfalo/metabolismo , Tecnologia de Fibra Óptica/métodos , Neurônios/metabolismo , Fibras Ópticas , Fotometria/métodos , Animais , Técnicas Biossensoriais/métodos , Eletroquímica/métodos , Imageamento por Ressonância Magnética/métodos , Transmissão Sináptica
7.
Annu Rev Anal Chem (Palo Alto Calif) ; 13(1): 159-181, 2020 06 12.
Artigo em Inglês | MEDLINE | ID: mdl-32151142

RESUMO

Neuronal transmission relies on electrical signals and the transfer of chemical signals from one neuron to another. Chemical messages are transmitted from presynaptic neurons to neighboring neurons through the triggered fusion of neurotransmitter-filled vesicles with the cell plasma membrane. This process, known as exocytosis, involves the rapid release of neurotransmitter solutions that are detected with high affinity by the postsynaptic neuron. The type and number of neurotransmitters released and the frequency of vesicular events govern brain functions such as cognition, decision making, learning, and memory. Therefore, to understand neurotransmitters and neuronal function, analytical tools capable of quantitative and chemically selective detection of neurotransmitters with high spatiotemporal resolution are needed. Electrochemistry offers powerful techniques that are sufficiently rapid to allow for the detection of exocytosis activity and provides quantitative measurements of vesicle neurotransmitter content and neurotransmitter release from individual vesicle events. In this review, we provide an overview of the most commonly used electrochemical methods for monitoring single-vesicle events, including recent developments and what is needed for future research.

8.
ACS Chem Neurosci ; 10(3): 1744-1752, 2019 03 20.
Artigo em Inglês | MEDLINE | ID: mdl-30605606

RESUMO

Neuronal communication relies on vesicular neurotransmitter release from signaling neurons and detection of these molecules by neighboring neurons. Glutamate, the main excitatory neurotransmitter in the mammalian brain, is involved in nearly all brain functions. However, glutamate has suffered from detection schemes that lack temporal and spatial resolution allowed by electrochemistry. Here we show an amperometric, novel, ultrafast enzyme-based nanoparticle modified sensor, measuring random bursts of hundreds to thousands of rapid spontaneous glutamate exocytotic release events at approximately 30 Hz frequency in the nucleus accumbens of rodent brain slices. Characterizing these single submillisecond exocytosis events revealed a great diversity in spike shape characteristics and size of quantal release, suggesting variability in fusion pore dynamics controlling the glutamate release by cells in this brain region. Hence, this novel biosensor allows recording of rapid single glutamate exocytosis events in the brain tissue and offers insight on regulatory aspects of exocytotic glutamate release, which is critical to understanding of brain glutamate function and dysfunction.


Assuntos
Exocitose/efeitos dos fármacos , Ácido Glutâmico/farmacologia , Neurônios/efeitos dos fármacos , Neurotransmissores/metabolismo , Animais , Técnicas Biossensoriais/métodos , Encéfalo/efeitos dos fármacos , Eletroquímica/métodos , Exocitose/fisiologia , Camundongos
9.
ACS Chem Neurosci ; 6(1): 181-8, 2015 Jan 21.
Artigo em Inglês | MEDLINE | ID: mdl-25565357

RESUMO

Acetylcholine is a highly abundant nonelectroactive neurotransmitter in the mammalian central nervous system. Neurochemical release occurs on the millisecond time scale, requiring a fast, sensitive sensor such as an enzymatic amperometric electrode. Typically, the enzyme used for enzymatic electrochemical sensors is applied in excess to maximize signal. Here, in addition to sensitivity, we have also sought to maximize temporal resolution, by designing a sensor that is sensitive enough to work at near monolayer enzyme coverage. Reducing the enzyme layer thickness increases sensor temporal resolution by decreasing the distance and reducing the diffusion time for the enzyme product to travel to the sensor surface for detection. In this instance, the sensor consists of electrodeposited gold nanoparticle modified carbon fiber microelectrodes (CFMEs). Enzymes often are sensitive to curvature upon surface adsorption; thus, it was important to deposit discrete nanoparticles to maintain enzyme activity while depositing as much gold as possible to maximize enzyme coverage. To further enhance sensitivity, the enzymes acetylcholinesterase (AChE) and choline oxidase (ChO) were immobilized onto the gold nanoparticles at the previously determined optimal ratio (1:10 AChE/ChO) for most efficient sequential enzymatic activity. This optimization approach has enabled the rapid detection to temporally resolve single vesicle acetylcholine release from an artificial cell. The sensor described is a significant advancement in that it allows for the recording of acetylcholine release on the order of the time scale for neurochemical release in secretory cells.


Assuntos
Acetilcolina/metabolismo , Células Artificiais/citologia , Vesículas Citoplasmáticas/metabolismo , Técnicas Eletroquímicas , Oxirredutases do Álcool , Animais , Células Artificiais/metabolismo , Técnicas Biossensoriais , Cloretos/metabolismo , Dopamina/metabolismo , Ouro , Compostos de Ouro/metabolismo , Nanopartículas Metálicas , Microeletrodos , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa