Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 294
Filtrar
1.
Arthroscopy ; 2024 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-38936557

RESUMO

PURPOSE: To assess the ability of ChatGPT-4, an automated Chatbot powered by artificial intelligence, to answer common patient questions concerning the Latarjet procedure for patients with anterior shoulder instability and compare this performance with Google Search Engine. METHODS: Using previously validated methods, a Google search was first performed using the query "Latarjet." Subsequently, the top 10 frequently asked questions (FAQs) and associated sources were extracted. ChatGPT-4 was then prompted to provide the top 10 FAQs and answers concerning the procedure. This process was repeated to identify additional FAQs requiring discrete-numeric answers to allow for a comparison between ChatGPT-4 and Google. Discrete, numeric answers were subsequently assessed for accuracy on the basis of the clinical judgment of 2 fellowship-trained sports medicine surgeons who were blinded to search platform. RESULTS: Mean (± standard deviation) accuracy to numeric-based answers was 2.9 ± 0.9 for ChatGPT-4 versus 2.5 ± 1.4 for Google (P = .65). ChatGPT-4 derived information for answers only from academic sources, which was significantly different from Google Search Engine (P = .003), which used only 30% academic sources and websites from individual surgeons (50%) and larger medical practices (20%). For general FAQs, 40% of FAQs were found to be identical when comparing ChatGPT-4 and Google Search Engine. In terms of sources used to answer these questions, ChatGPT-4 again used 100% academic resources, whereas Google Search Engine used 60% academic resources, 20% surgeon personal websites, and 20% medical practices (P = .087). CONCLUSIONS: ChatGPT-4 demonstrated the ability to provide accurate and reliable information about the Latarjet procedure in response to patient queries, using multiple academic sources in all cases. This was in contrast to Google Search Engine, which more frequently used single-surgeon and large medical practice websites. Despite differences in the resources accessed to perform information retrieval tasks, the clinical relevance and accuracy of information provided did not significantly differ between ChatGPT-4 and Google Search Engine. CLINICAL RELEVANCE: Commercially available large language models (LLMs), such as ChatGPT-4, can perform diverse information retrieval tasks on-demand. An important medical information retrieval application for LLMs consists of the ability to provide comprehensive, relevant, and accurate information for various use cases such as investigation about a recently diagnosed medical condition or procedure. Understanding the performance and abilities of LLMs for use cases has important implications for deployment within health care settings.

2.
Artigo em Inglês | MEDLINE | ID: mdl-39126271

RESUMO

PURPOSE: To define the minimal clinically important difference (MCID) for measures of pain and function at 2, 5 and 10 years after osteochondral autograft transplantations (OATs). METHODS: Patients undergoing OATs of the knee were identified from a prospectively maintained cartilage surgery registry. Baseline demographic, injury and surgical factors were collected. Patient-reported outcome scores (PROMs) were collected at baseline, 2-, 5- and 10-year follow-up, including the International Knee Documentation Committee (IKDC) score, Knee Outcome Survey Activities of Daily Living Scale (KOS-ADLS), Marx activity scale and Visual Analogue Scale (VAS) for pain. The MCIDs were quantified for each metric utilizing a distribution-based method equivalent to one-half the standard deviation of the mean change in outcome score. The percentage of patients achieving MCID as a function of time was assessed. RESULTS: Of 63 consecutive patients who underwent OATs, 47 (74.6%) patients were eligible for follow-up (surgical date before October 2021) and had fully completed preoperative PROMs. A total of 39 patients (83%) were available for a minimum 2-year follow-up, with a mean (±standard deviation) follow-up of 5.8 ± 3.4 years. The MCIDs were determined to be 9.3 for IKDC, 2.5 for Marx, 7.4 for KOS-ADLS and 12.9 for pain. At 2 years, 78.1% of patients achieved MCID for IKDC, 77.8% for Marx, 75% for KOS-ADLS and 57.9% for pain. These results were generally maintained through 10-year follow-ups, with 75% of patients achieving MCID for IKDC, 80% for Marx, 80% for KOS-ADLS and 69.8% for pain. CONCLUSIONS: The majority of patients achieved a clinically relevant outcome improvement after OATs of the knee, with results sustained through 10-year follow-up. Patients who experience clinically relevant outcome improvement after OATs in the short term continue to experience sustained benefits at longer-term follow-up. These data provide valuable prognostic information when discussing patient candidacy and the expected trajectory of recovery. LEVEL OF EVIDENCE: Level III.

3.
J Shoulder Elbow Surg ; 32(10): 2115-2122, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37172888

RESUMO

BACKGROUND: Accurate and rapid identification of implant manufacturer and model is critical in the evaluation and management of patients requiring revision total shoulder arthroplasty (TSA). Failure to correctly identify implant designs in these circumstances may lead to delay in care, unexpected intraoperative challenges, increased morbidity, and excess health care costs. Deep learning (DL) permits automated image processing and holds the potential to mitigate such challenges while improving the value of care rendered. The purpose of this study was to develop an automated DL algorithm to identify shoulder arthroplasty implants from plain radiographs. METHODS: A total of 3060 postoperative images from patients who underwent TSA between 2011 and 2021 performed by 26 fellowship-trained surgeons at 2 independent tertiary academic hospitals in the Pacific Northwest and Mid-Atlantic Northeast were included. A DL algorithm was trained using transfer learning and data augmentation to classify 22 different reverse TSA and anatomic TSA prostheses from 8 implant manufacturers. Images were split into training and testing cohorts (2448 training and 612 testing images). Optimized model performance was assessed using standardized metrics including the multiclass area under the receiver operating characteristic curve (AUROC) and compared with a reference standard of implant data from operative reports. RESULTS: The algorithm classified implants at a mean speed of 0.079 seconds (±0.002 seconds) per image. The optimized model discriminated between 8 manufacturers (22 unique implants) with AUROCs of 0.994-1.000, accuracy of 97.1%, and sensitivities between 0.80 and 1.00 on the independent testing set. In the subset of single-institution implant predictions, a DL model identified 6 specific implants with AUROCs of 0.999-1.000, accuracy of 99.4%, and sensitivity >0.97 for all implants. Saliency maps revealed key differentiating features across implant manufacturers and designs recognized by the algorithm for classification. CONCLUSION: A DL model demonstrated excellent accuracy in identifying 22 unique TSA implants from 8 manufacturers. This algorithm may provide a clinically meaningful adjunct in assisting with preoperative planning for the failed TSA and allows for scalable expansion with additional radiographic data and validation efforts.


Assuntos
Artroplastia do Ombro , Prótese Articular , Articulação do Ombro , Humanos , Artroplastia do Ombro/métodos , Inteligência Artificial , Estudos Retrospectivos , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/cirurgia
4.
J Shoulder Elbow Surg ; 31(6): 1254-1260, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35066121

RESUMO

BACKGROUND: The role of the long head of the biceps tendon (LHBT) in glenohumeral stability is not fully understood. Most objects are lifted in the sagittal plane with forward flexion, which stresses the posterior aspect of the unconstrained glenohumeral joint. Determining the mechanism by which the shoulder maintains stability with functional motions is important to understanding the pathoanatomy of degenerative shoulders. Our hypothesis was that the LHBT resists posterior translation of the humeral head (HH) during forward flexion by tensioning the posterior capsuloligamentous complex. METHODS: Ten fresh-frozen cadaveric shoulders were tested using an established shoulder simulator that loads the LHBT, rotator cuff, and deltoid tendons through a system of pulleys. A motion tracking system recorded glenohumeral translations with an accuracy of ±0.2 mm. In each subject, the scapula was fixed and the humerus was tested in 6 positions: 30° and 60° of glenohumeral forward flexion at (1) maximum internal rotation (IR), (2) neutral rotation, and (3) maximum external rotation (ER). The deltoid was loaded with 100 N, and the infraspinatus and subscapularis were loaded with 22 N each. The difference in glenohumeral translation was calculated at each position comparing the LHBT loaded with 45 N or unloaded. RESULTS: At 30° of glenohumeral forward flexion, unloading the LHBT increased HH posterior translation by 2.5 mm (±0.9 mm; P < .001), 1.7 mm (±1.0 mm; P < .001), and 1.0 mm (±0.9 mm; P = .01) at maximum ER, neutral rotation, and maximum IR, respectively. At 60° of glenohumeral forward flexion, unloading the LHBT increased HH posterior translation by 2.8 mm (±1.2 mm; P < .001), 2.4 mm (±1.6 mm; P < .001), and 1.7 mm (±1.4 mm; P < .001) at maximum ER, neutral rotation, and maximum IR, respectively. CONCLUSION: LHBT loading resists posterior translation of the HH during forward flexion. These data support the role of the LHBT as a posterior stabilizer of the shoulder, specifically when a person is carrying objects in front of them. Further work is needed to determine if unloading the LHBT, as is done with biceps tenotomy or tenodesis, may eventually lead to posterior labral pathology, or to the posterior glenoid wear commonly seen with osteoarthritis.


Assuntos
Articulação do Ombro , Ombro , Fenômenos Biomecânicos , Cadáver , Humanos , Cabeça do Úmero/cirurgia , Amplitude de Movimento Articular , Articulação do Ombro/cirurgia , Tendões/cirurgia
5.
J Shoulder Elbow Surg ; 31(6): 1300-1307, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35051539

RESUMO

BACKGROUND: Reverse total shoulder arthroplasty is often performed to treat rotator cuff tear arthropathy with irreparable rotator cuff tears. Patients with full-thickness tears involving the posterior cuff and teres minor specifically lose active external rotation of the humerus, limiting activities of daily living. A latissimus dorsi transfer has been described as one potential solution, but few studies have compared different latissimus dorsi transfer sites. This study assesses the biomechanics of 3 latissimus dorsi transfer sites, examining external rotation, deltoid muscle forces, and force across the glenoid for specific activities. METHODS: The Newcastle Shoulder Model was modified to include a Delta III reverse shoulder arthroplasty and was used to model the effects of 3 latissimus dorsi transfer sites-anterior, posterolateral, and posterodistal-in the setting of teres minor deficiency. The latissimus dorsi was represented by 5 muscle elements approximating anatomic fascicle divisions. Kinematic data sets representing common activities were input into the model, allowing calculation of muscle forces and glenoid loads. RESULTS: Each of the 3 latissimus dorsi transfer sites demonstrated a change of moment arm from internal to external rotation with increased magnitude. Average maximum deltoid muscle forces and glenoid loading across all motions decreased for each of the 3 transfer sites, with the greatest decreased force noted for the posterior deltoid. This decrease in deltoid force and glenoid loading was significantly greater with the anterior and posterolateral transfer sites, relative to the posterodistal site. DISCUSSION: Latissimus dorsi transfer to all 3 sites in the setting of reverse total shoulder arthroplasty and posterior rotator cuff deficiency resulted in large external rotation moment arms. The transferred latissimus dorsi shared the external rotation load and resulted in decreased deltoid forces and glenoid loading with very small differences between the 3 transfer sites. The posterodistal location reduced deltoid force and glenoid loading to a lower degree compared with other sites, but it also showed that it did not alter the tendon length compared with the native shoulder.


Assuntos
Artroplastia do Ombro , Lesões do Manguito Rotador , Articulação do Ombro , Músculos Superficiais do Dorso , Atividades Cotidianas , Humanos , Amplitude de Movimento Articular/fisiologia , Manguito Rotador/cirurgia , Lesões do Manguito Rotador/cirurgia , Articulação do Ombro/cirurgia , Músculos Superficiais do Dorso/cirurgia , Transferência Tendinosa/métodos
6.
J Shoulder Elbow Surg ; 31(2): 245-251, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34592407

RESUMO

BACKGROUND: The purpose of this study was to determine whether postoperative patient-reported outcomes improved over time following anatomic total shoulder arthroplasty (TSA) and reverse total shoulder arthroplasty (RTSA). METHODS: We performed a retrospective analysis of prospectively collected patient-reported outcomes from our institution's registry between 2008 and 2018 (N = 1899). American Shoulder and Elbow Surgeons (ASES) scores at a minimum of 2 years postoperatively were required. Univariable linear models were used to test the association between year of surgery and improvement in ASES scores at 2- and 5-year follow-up, as well as any association with age, sex, primary or revision surgery, hand dominance, American Society of Anesthesiologists classification, rotator cuff status, primary diagnosis, and Walch classification. Multivariable models were created to analyze ASES score improvement by index year while controlling for significant factors. RESULTS: In the univariable analysis, 5-year ASES difference scores increased each year by a mean of 1.65 (P < .001; 95% confidence interval [CI], 0.75-2.55) for TSA, 2.50 (P = .014; 95% CI, 0.52-4.49) for RTSA, and 1.64 (P < .001; 95% CI, 0.81-2.47) for the overall population. Patient sex, American Society of Anesthesiologists classification, rotator cuff status, primary diagnosis, Walch classification, and revision procedures were also significant factors affecting ASES scores. On multivariable analysis controlling for these factors, 5-year ASES difference scores were still significantly associated with year of surgery, increasing each year by a mean of 2.20 (P < .001; 95% CI, 0.91-3.50) for TSA, 4.83 (P < .001; 95% CI, 1.17-8.49) for RTSA, and 1.66 (P < .001; 95% CI, 0.81-2.51) for the entire population. CONCLUSION: Both anatomic TSA and RTSA patients reported increasing ASES difference scores at 5-year follow-up as time passed. These findings may indicate that advances in shoulder arthroplasty have resulted in better patient outcomes over time. Further research is needed to clarify which factors influence improvements in outcomes, particularly for revision procedures.


Assuntos
Artroplastia do Ombro , Articulação do Ombro , Humanos , Amplitude de Movimento Articular , Estudos Retrospectivos , Articulação do Ombro/cirurgia , Resultado do Tratamento
7.
J Shoulder Elbow Surg ; 31(2): 420-427, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34592410

RESUMO

BACKGROUND: Irreparable subscapularis (SSc) tears alter the dynamic force coupling of the shoulder, resulting in pain, weakness, and impaired shoulder function. Pectoralis major (Pma), pectoralis minor (Pmi), and latissimus dorsi (LD) transfers are treatment options for irreparable SSc tears, but clinical outcomes vary. The purpose of this study was to compare the biomechanical properties of Pma, Pmi, and LD transfers in an SSc-deficient shoulder using a computational model. METHODS: A computer shoulder model was used to investigate the moment arms of Pma, Pmi, and LD tendon transfers compared with an intact SSc. Nine computed tomography scans from subjects without osteoarthritis were used. Virtual Pma, Pmi, and LD transfers were performed to the upper border of the SSc insertion site on the lesser tuberosity of the humerus. Muscle moment arms were computed for functional motions of 0°-80° of internal rotation with the arm in 20° and 90° of shoulder abduction and 0°-150° of shoulder abduction. The results were compared with those of the native SSc moment arms. A repeated-measures analysis of variance was then performed to determine significant differences. RESULTS: Internal rotation moment arms of the transferred Pma and Pmi decreased significantly after 30° and 40° of internal rotation compared with the SSc moment arm of the intact shoulder, whereas the moment arm of LD transfer more closely mimicked that of the native SSc through 0°-80° of internal rotation. All 3 tendon transfer configurations demonstrated weak abductive moment arms (7.6-8.0 mm), comparable to the intact SSc (7.8 mm) but significantly lower than the intact adductive moment arms of the native Pma and LD (26.8 mm and 28.2 mm, respectively). CONCLUSION: LD transfer most closely approximates the native SS regarding internal rotation moment arms. However, LD transfer also showed a reduction in adductive moment arms.


Assuntos
Lesões do Manguito Rotador , Articulação do Ombro , Músculos Superficiais do Dorso , Fenômenos Biomecânicos , Humanos , Músculos Peitorais , Amplitude de Movimento Articular , Manguito Rotador , Ombro , Articulação do Ombro/diagnóstico por imagem , Transferência Tendinosa
8.
J Shoulder Elbow Surg ; 31(8): 1696-1703, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35158066

RESUMO

BACKGROUND AND HYPOTHESIS: Arthroscopic rotator cuff repair surgery is one of the most common shoulder procedures performed in the United States. Although several studies have shown considerable symptomatic relief in the short term following surgery, a relatively high rate of recurrent defects has led surgeons to question the long-term durability of this operation. We hypothesized that outcomes at a minimum of 15 years of follow-up in patients who underwent all-arthroscopic rotator cuff repair would be maintained and would remain significantly improved compared with the preoperative status. METHODS: All-arthroscopic rotator cuff repairs were performed in 193 patients from 2003 to 2005. Patient-reported outcomes were collected preoperatively and at 1, 2, 5, and ≥15 years postoperatively. The primary outcome was the American Shoulder and Elbow Surgeons (ASES) score. Secondary outcomes included Single Assessment Numeric Evaluation (SANE), Shoulder Activity Scale (SAS), visual analog scale, and Patient-Reported Outcomes Measurement Information System (PROMIS)-Upper Extremity (UE) scores. Patient demographic characteristics, revision surgical procedures, and complications were recorded. Generalized estimating equations were used to model scores over time, and multiple comparisons between time points were performed using Tukey adjustment. RESULTS: This study included 60 patients with a mean follow-up period of 16.5 years (range, 15.8-17.7 years). The mean ASES score improved from 60.2 ± 18.8 preoperatively to 93.0 ± 9.4 at ≥15 years (P < .0001). The mean visual analog scale pain score decreased from 4.1 ± 0.7 preoperatively to 0.7 ± 0.3 at ≥15 years (P < .0001). The average SANE, SAS, and PROMIS-UE scores at ≥15 years were 87.8 ± 14.8, 8.8 ± 4.3, and 49.6 ± 10.2, respectively. Of 60 patients, 7 underwent revision surgery. Older age and female sex were associated with lower SAS scores at 15 years, whereas female sex was associated with lower PROMIS-UE scores. There were no factors predictive of ASES or SANE scores. CONCLUSION: At long-term follow-up (≥15 years), the patient-reported outcomes of all-arthroscopic rotator cuff repair show significant improvement from baseline preoperative function and remain durable over a period of 15 years. This information is useful in counseling patients regarding the long-term results of this procedure.


Assuntos
Lesões do Manguito Rotador , Manguito Rotador , Artroscopia/métodos , Feminino , Seguimentos , Humanos , Estudos Retrospectivos , Manguito Rotador/cirurgia , Resultado do Tratamento
9.
J Shoulder Elbow Surg ; 31(3): 545-552, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34619352

RESUMO

BACKGROUND: Aseptic loosening from implant-associated osteolysis in reverse shoulder arthroplasty (RSA) may contribute to premature implant failure. Although articular side polyethylene (PE) damage has been well documented in the literature, no studies to date have investigated backside wear in RSA. The aims of this investigation were to (1) document and compare the damage between the backside and articular surface in explanted RSA components, (2) assess whether certain quadrants have a greater propensity for damage, and (3) report the most common mode(s) of backside PE damage. METHODS: Twenty-one RSA humeral liners retrieved during revision procedures between 2005 and 2014 were included for analysis. The mean time between implantation and extraction was 16 months (10 days-88 months). Diagnoses at the time of revision included dislocation (10), infection (4), mechanical failure (3), loosening (2), and unknown (2). Liners were examined under light microscopy (×10-30 magnification) and damage on the articular and backside of the liner surface was graded using the modified Hood score. The location and damage modality were compared between the articular side and backside of the implant. RESULTS: Damage was noted on the articular surfaces of all 21 liners and on the backside surface of 20 liners. The total damage in all the quadrants was higher on the articular surface than on the backside of the component, with a mean difference in total quadrant damage scores of 11.74 ± 3.53 (P < .001). There was no difference in damage among the quadrants on the backside (P = .44) or the articular surface (P = .08). The articular side exhibited greater scratching, abrasion, and surface deformation than the backside (P < .001). CONCLUSIONS: This short-term retrieval study demonstrated that backside PE damage occurs on the humeral component of RSA implants. There was greater damage to the articular side of the liner but wear to the backside was present in almost all liners. The clinical importance of backside wear in RSA and its overall contribution to PE particulate disease and osteolysis needs further investigation.


Assuntos
Artroplastia do Ombro , Osteólise , Artroplastia do Ombro/efeitos adversos , Humanos , Polietileno , Desenho de Prótese , Falha de Prótese
10.
J Shoulder Elbow Surg ; 31(11): 2358-2365, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-35597534

RESUMO

BACKGROUND: Dynamic anterior shoulder stabilization (DAS) with Bankart repair is a recently described stabilization technique thought to be more robust than an isolated Bankart repair while avoiding many coracoid transfer-related complications and technical demands. DAS involves transfer of the long head biceps through a subscapularis split to the anterior glenoid to create a sling effect. We hypothesize that DAS with Bankart repair will restore anterior stability in a human-cadaveric model with subcritical (15%) glenoid bone loss. METHODS: Eight cadaveric shoulders were tested using an established shoulder simulator to record glenohumeral translations with an accuracy of ±0.2 mm. Shoulders were tested in 5 states-intact soft tissues, Bankart defect with 15% bone loss, isolated Bankart repair, DAS with Bankart repair, isolated DAS, and Latarjet. A 45 N anterior force was applied through the pectoralis major tendon, and translation of the humeral head was recorded and compared with repeated measures analysis of variance. RESULTS: The anterior translation in the intact (native) glenoid was 4.7 mm at neutral position and 4.6 mm at 45° external rotation. Anterior translation significantly increased after introducing a Bankart defect with 15% glenoid bone loss to 9.1 mm (neutral, P = .002) and 9.5 mm (45° external rotation, P < .001). All repair conditions showed a significant decrease in anterior translation relative to Bankart defect. DAS with Bankart repair decreased anterior translation compared with the Bankart defect: 2.7 mm (neutral, P < .001) and 2.1 mm (45° external rotation, P < .001). DAS with Bankart repair significantly decreased anterior translation compared with the isolated Bankart repair (2.7 mm vs. 4.7 mm, P = .023) and the isolated DAS (2.7 mm vs. 4.3 mm, P = .041) in neutral position. The Latarjet procedure resulted in the greatest reduction in anterior translation compared with the Bankart defect: 1.2 mm (neutral, P < .001) and 1.9 mm (45° external rotation, P < .001). CONCLUSIONS: DAS with Bankart repair is a viable alternative to restore anterior glenohumeral stability with a 15% glenoid defect at a greater degree than either DAS or Bankart repair alone. The Latarjet procedure was the most effective in reducing anterior translation but restrained the anterior translation significantly more than the native glenoid.


Assuntos
Doenças Ósseas Metabólicas , Instabilidade Articular , Luxação do Ombro , Articulação do Ombro , Humanos , Fenômenos Biomecânicos , Cadáver , Instabilidade Articular/cirurgia , Instabilidade Articular/etiologia , Luxação do Ombro/cirurgia , Luxação do Ombro/complicações , Articulação do Ombro/cirurgia
11.
Arthroscopy ; 37(3): 953-960, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33130059

RESUMO

PURPOSE: To evaluate the effect of soaking of anterior cruciate ligament (ACL) grafts in vancomycin solution on graft biomechanical properties at the time of implantation. METHODS: The central third of patellar tendons was harvested from mature bovine knees and prepared as a tendon-only graft or a bone-tendon-bone (BTB) graft. Tendons were wrapped in gauze soaked in vancomycin solution (VS) (5 mg/mL) or normal saline (NS) and left to stand for 30 minutes at room temperature, simulating graft exposure times in the operating room during ACL reconstruction. Tensile testing was carried out on a materials testing system with (1) low-magnitude loading (60 N at 3 mm/s) with repeated testing of tendon-only grafts; and (2) high-magnitude loading (600 N at 10 mm/min) of BTB grafts. For tendon-only grafts, specimens were first wrapped in NS-soaked gauze and underwent testing, with repeated testing performed after wrapping in gauze soaked in VS or buffered VS (pH 7.0). For BTB grafts, specimens were randomly assigned to treatment with VS or NS. RESULTS: For tendon-only grafts, there was no difference in Young's modulus (YM) after soaking with VS soaking (baseline, 12.69 MPa; treatment, 16.07 ± 4.44 MPa; P = .99) or buffered VS (baseline, 12.45 ± 4.55 MPa; treatment, 15.56 ± 2.83 MPa; P = .99). For BTB grafts, there were no differences in elongation strain (VS, 46.8% ± 7.0%; NS, 31.5% ± 13.5%, P = .19) or YM (VS, 158.4 ± 15.8 MPa; NS, 158.5 ± 23.3 MPa, P = .99). CONCLUSIONS: According to controlled biomechanical tests, vancomycin soaking of patellar tendon grafts does not adversely affect time-zero material properties. CLINICAL RELEVANCE: This study suggests that vancomycin wrapping has no immediate adverse effects on the biomechanical properties of ACL grafts. Randomized controlled trials are warranted to validate the widespread use of vancomycin soaking of tendon grafts for infection prophylaxis during ACL reconstruction.


Assuntos
Lesões do Ligamento Cruzado Anterior/cirurgia , Reconstrução do Ligamento Cruzado Anterior , Antibacterianos/uso terapêutico , Ligamento Patelar/transplante , Vancomicina/uso terapêutico , Animais , Fenômenos Biomecânicos , Cadáver , Bovinos , Estresse Mecânico
12.
Arthroscopy ; 37(6): 1757-1766.e2, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33515735

RESUMO

PURPOSE: To use computed tomography (CT) to determine a reproducible method of coracoid measurement to compare the ability of the classic Latarjet technique and the congruent arc modification (CAM) to restore native glenoid diameter and to develop a preoperative planning algorithm for glenoid restoration with a goal of achieving an on-track shoulder. METHODS: Coracoid dimensions were measured on multiplanar reconstructed shoulder CT scans of patients aged 18 to 45 years obtained between December 1, 2019, and March 13, 2020. Patients were excluded if CT demonstrated osteophyte formation, glenoid dysplasia, coracoid fracture, or tumor. The proportion of glenoid diameter able to be restored using classic Latarjet technique and CAM were calculated. A treatment algorithm was proposed considering the amount of bone loss present and coracoid dimensions. RESULTS: Coracoid dimensions of 117 consecutive patients were measured and varied considerably (length: 17.5-31.8 mm, width: 9.1-20.5 mm, thickness: 6.1-15.7 mm). While most patients had harvestable coracoid length ≥20 mm (male: 96.3% vs female: 94.4%, P = .65), only 27.8% of female patients had coracoid thickness ≥10 mm. When comparing Latarjet techniques, there was no difference in the proportion of patients in whom 30% glenoid diameter could be fully restored, but CAM was able to restore at least 35% in more male and female patients (98.8% vs 79.0% and 100% vs 61.1%, respectively, P = .00001). Intra- and inter-rater reliability was excellent ( intraclass correlation coefficient ≥0.950 for all dimensions). CONCLUSIONS: We describe a reliable method of measuring coracoid dimensions for preoperative planning of glenoid restoration. The classic Latarjet technique reliably restores the glenoid anteroposterior diameter with bone loss of up to 30%. The majority of female patients have coracoid thickness <10 mm, which may increase the risk of graft fracture when using CAM. The decision to use the classic Latarjet technique or CAM considers each individual's glenoid and coracoid dimensions with a goal of achieving an on-track shoulder. CLINICAL RELEVANCE: Our reliable method of coracoid measurement demonstrated the differing abilities of the classic Latarjet and CAM to restore the native glenoid diameter. An evidence-based algorithm using these measurements was developed to assist in preoperative planning for glenohumeral instability in the setting of bone loss, with a goal of achieving an on-track shoulder. Alternative techniques may be considered if an on-track shoulder cannot be achieved with Latarjet.


Assuntos
Instabilidade Articular , Articulação do Ombro , Transplante Ósseo , Feminino , Humanos , Instabilidade Articular/diagnóstico por imagem , Instabilidade Articular/cirurgia , Masculino , Reprodutibilidade dos Testes , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/cirurgia , Tomografia Computadorizada por Raios X
13.
Arthroscopy ; 37(4): 1086-1095.e1, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33278535

RESUMO

PURPOSE: To report clinical and functional outcomes including return to preinjury activity level following arthroscopic-assisted coracoclavicular (CC) ligament reconstruction (AA-CCR) and to determine associations between return to preinjury activity level, radiographic outcomes, and patient-reported outcomes following AA-CCR. METHODS: A institutional registry review of all AA-CCR using free tendon grafts from 2007 to 2016 was performed. Clinical assessment included Single Assessment Numeric Evaluation (SANE) score and return to preinjury activity level at final follow-up. Treatment failure was defined as (1) revision acromioclavicular stabilization surgery, (2) unable to return to preinjury activity level, or (3) radiographic loss of reduction (RLOR, >25% CC distance compared with contralateral side). SANE scores, return to activity, and RLOR were compared between patients within each category of treatment failure, by grade of injury, and whether concomitant pathology was treated. RESULTS: There were 88 patients (89.8% male) with mean age of 39.6 years and minimum 2-year clinical follow-up (mean 6.1 years). Most injuries were Rockwood grade V (63.6%). Mean postoperative SANE score was 86.3 ± 17.5. Treatment failure occurred in 17.1%: 8.0% were unable to return to activity, 5.7% had RLOR, and 3.4% underwent revision surgery due to traumatic reinjury. SANE score was lower among patients who were unable to return to activity compared with those with RLOR and compared with nonfailures (P = .0002). There were no differences in revision surgery rates, return to activity, or SANE scores according to Rockwood grade or if concomitant pathology was treated. CONCLUSIONS: AA-CCR with free tendon grafts resulted in good clinical outcomes and a high rate of return to preinjury activity level. RLOR did not correlate with return to preinjury activity level. Concomitant pathology that required treatment did not adversely affect outcomes. Return to preinjury activity level may be a more clinically relevant outcome measure than radiographic maintenance of acromioclavicular joint reduction. LEVEL OF EVIDENCE: IV (Case Series).


Assuntos
Articulação Acromioclavicular/cirurgia , Artroscopia , Procedimentos de Cirurgia Plástica , Adulto , Feminino , Seguimentos , Humanos , Ligamentos Articulares/cirurgia , Masculino , Medidas de Resultados Relatados pelo Paciente , Período Pós-Operatório , Resultado do Tratamento
14.
J Shoulder Elbow Surg ; 30(9): 2166-2176, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33418091

RESUMO

BACKGROUND: Success of superior capsule reconstruction (SCR) using both fascia lata (FL) and human acellular dermal (ACD) allografts have been reported. One possible explanation for a discrepancy in outcomes may be attributed to graft thickness. SCR with commercially available 3-mm-thick ACD allograft is not biomechanically equivalent to FL. Our hypothesis was that SCR with a single 6-mm-thick ACD allograft will restore the subacromial space distance (SubDist) and peak subacromial contact pressures (PSCPs) to intact shoulder and will be comparable to SCR with an 8-mm FL allograft. METHODS: Eight cadaveric shoulders were tested in 4 conditions: intact, irreparable supraspinatus tear (SST), SCR FL allograft (8-mm-thick), and SCR single ACD allograft (6-mm-thick). SubDist and PSCP were measured at 0°, 30°, and 60° of glenohumeral abduction in the scapular plane. Parameters were compared using a repeated measures analysis of variance with Tukey post hoc test, and graft dimensions were compared using a Student t test. RESULTS: SST had decreased SubDist (P < .05) and increased PSCP (P < .05) compared with the intact state. At all angles, the SCR ACD allograft demonstrated increased SubDist compared with the tear condition (P < .001), with no difference between grafts. Furthermore, there was decreased PSCP after both ACD and FL SCR compared with the intact condition, with no difference between grafts at 0° (P = .006, P = .028) and 60° abduction (P = .026, P = .013). Both ACD and FL grafts elongated during testing. CONCLUSIONS: Our results suggest SCR with a single 6-mm-thick ACD allograft is noninferior to FL regarding SubDist and PSCP while completely restoring the superior stability of the glenohumeral joint compared with the intact state.


Assuntos
Lesões do Manguito Rotador , Articulação do Ombro , Aloenxertos , Fenômenos Biomecânicos , Cadáver , Fascia Lata/transplante , Humanos , Amplitude de Movimento Articular , Manguito Rotador/cirurgia , Lesões do Manguito Rotador/cirurgia , Articulação do Ombro/cirurgia
15.
J Clin Ultrasound ; 49(3): 194-198, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32984955

RESUMO

PURPOSE: To describe our technique of aspirating symptomatic anterior cruciate ligament (ACL) mucinous cysts in the posterior intercondylar notch with ultrasound guidance, and to detail short-term patient outcomes. METHODS: We identified 13 patients from February 2008 to May 2020 who underwent ultrasound-guided aspiration of symptomatic ACL mucinous cysts in the posterior intercondylar notch. Post-procedural imaging was reviewed to evaluate the degree of cyst decompression. Needle size was noted. Post-procedural symptomatology was also assessed. RESULTS: No or minimal fluid was initially aspirated in 11/13 (84.6%) patients. For the two patients in which the cysts were aspirated completely with initial needle placement, with no need for lavage, a 13-gauge trocar was utilized. Of the remaining cysts, 10/11 were aspirated with an 18-gauge needle and one with a 20-gauge needle. Subsequent lavage was performed in 10 of the remaining 11 patients. After lavage, in eight there was a reduction of at least 50% volume by retrospective image interpretation; of 25% to 50% volume in one patient and of less than 25% volume in one patient. Five of the 13 patients reported immediate post-procedural symptomatic relief. In the other patients, immediate efficacy or post-procedural symptomatology was not documented. CONCLUSION: Aspiration of symptomatic ACL mucinous cysts is a safe procedure and can provide symptomatic relief that may be temporary, but useful clinically. We recommend needles larger than 18 gauge for the best chance of successful aspiration.


Assuntos
Ligamento Cruzado Anterior/diagnóstico por imagem , Ligamento Cruzado Anterior/patologia , Biópsia por Agulha , Cistos/diagnóstico por imagem , Cistos/patologia , Cirurgia Assistida por Computador , Adulto , Cistos/cirurgia , Feminino , Humanos , Articulação do Joelho/diagnóstico por imagem , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Ultrassonografia
16.
Clin Anat ; 34(2): 283-296, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33386636

RESUMO

The three glenohumeral ligaments (superior, middle, and inferior) are discrete thickenings of the glenohumeral joint capsule and are critical to shoulder stability and function. Injuries to this area are a cause of significant musculoskeletal morbidity. A literature search was performed by a review of PubMed, Google Scholar, and OVID for all relevant articles published up until 2020. This study highlights the anatomy, biomechanical function, and injury patterns of the glenohumeral ligaments, which may be relevant to clinical presentation and diagnosis. A detailed understanding of the normal anatomy and biomechanics is a necessary prerequisite to understanding the injury patterns and clinical presentations of disorders involving the glenohumeral ligaments of the shoulder.


Assuntos
Cápsula Articular , Ligamentos Articulares , Articulação do Ombro , Fenômenos Biomecânicos , Humanos , Cápsula Articular/anatomia & histologia , Cápsula Articular/lesões , Cápsula Articular/fisiologia , Ligamentos Articulares/anatomia & histologia , Ligamentos Articulares/lesões , Ligamentos Articulares/fisiologia , Lesões do Ombro , Articulação do Ombro/anatomia & histologia , Articulação do Ombro/fisiologia
17.
Arthroscopy ; 36(9): 2380-2388, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32654928

RESUMO

PURPOSE: To describe the national rates of failed primary rotator cuff repair (RCR) requiring revision repair, using numerous patient characteristics previously defined in orthopaedic literature, including smoking history, diabetes mellitus (DM), hyperlipidemia (HLD), vitamin D deficiency, and osteoporosis to determine which factors independently affect the success of primary RCR. METHODS: A combined public and private national insurance database was searched from 2007 to 2016 for all patients who underwent RCR. Current Procedural Terminology codes were used to identify RCRs. Laterality modifiers for the primary surgery were used to identify subsequent revision RCRs. All patients who did not have a linked laterality modifier for the RCR Current Procedural Terminology code were excluded from the study. Basic demographics were recorded. International Classification of Diseases Ninth Revision codes were used to identify patient characteristics including Charlson Comorbidity Index, smoking status, DM, obesity, HLD, vitamin D deficiency, and osteoporosis. Patient age categorized as <60, 60-69, 70-74, or 75+ years old. Dichotomous data were analyzed with χ2 testing. Multivariable logistic regression was used to characterize independent associations with revision RCR. RESULTS: Included in the study were 41,467 patients (41,844 shoulders, 52.7% male patients) who underwent primary arthroscopic RCR. Of all arthroscopic RCRs, 3072 patients (3463 shoulders, 53.5% male patients) underwent revision RCR (8.38%). In both primary and revision RCR, patients age 60 to 69 years were most prevalent, accounting for 38.4% and 37.6% of the cohorts, respectively. The average time from primary RCR to revision was 414.9 days (median 214.0 days). Increasing age and male sex (odds ratio [OR] 1.10, P = .019, 95% confidence interval [CI] 1.02-1.19) were significantly predictive of revision RCR. Of the remaining patient characteristics, smoking most strongly predicted revision RCR (OR 1.36, P < .001, CI 1.23-1.49). Obesity (OR 1.32, P < .001, CI 1.21-1.43), hyperlipidemia (OR 1.09, P = .032, CI 1.01-1.18), and vitamin D deficiency (OR 1.18, P < .001, CI 1.08-1.28) also increased risk of revision RCR significantly. DM was found to be protective against revision surgery (OR 0.84, P < .001, CI 0.76-0.92). Overall comorbidity burden as measured by the Charlson Comorbidity Index was not predictive of revision RCR. CONCLUSIONS: Smoking, obesity, vitamin D deficiency, and HLD are shown to be independent risk factors for failure of primary RCR requiring revision RCR. However, despite the suggestions of previous studies, DM, osteoporosis, and overall comorbidity burden did not demonstrate independent associations in this study. LEVEL OF EVIDENCE: IV, Case Series.


Assuntos
Artroscopia/efeitos adversos , Complicações do Diabetes , Reoperação/estatística & dados numéricos , Lesões do Manguito Rotador/complicações , Lesões do Manguito Rotador/cirurgia , Adulto , Idoso , Artroplastia/efeitos adversos , Comorbidade , Bases de Dados Factuais , Diabetes Mellitus , Feminino , Humanos , Hiperlipidemias/complicações , Seguro Saúde , Masculino , Pessoa de Meia-Idade , Razão de Chances , Osteoporose/complicações , Estudos Retrospectivos , Fatores de Risco , Manguito Rotador/cirurgia , Resultado do Tratamento , Deficiência de Vitamina D/complicações
18.
J Shoulder Elbow Surg ; 29(3): e67-e74, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31619353

RESUMO

HYPOTHESIS: The aims of this study were to determine patient satisfaction and to identify predictors of satisfaction after reverse shoulder arthroplasty (RSA). We hypothesized that the majority of patients would be satisfied after RSA and that patients with worse preoperative mental and physical health would be less satisfied. METHODS: Satisfaction was assessed 2 years after primary RSA with domains for pain, work, activities, quality of life, and overall satisfaction. Preoperative and postoperative patient-reported factors were measured using the American Shoulder and Elbow Surgeons (ASES) shoulder score, Shoulder Activity Scale score, Short Form 12 (SF-12) mental and physical component summary scores, and visual analog scale (VAS) pain, fatigue, and general health scores. Pearson correlations were used to determine the relationship between patient-reported factors and satisfaction. Multivariate regression was performed to control for potential confounding variables. RESULTS: A total of 161 patients were evaluated at 2 years postoperatively. Patients were "very satisfied" in an average of 3.3 of the 5 domains. Improvements in ASES, Shoulder Activity Scale, VAS pain, and SF-12 physical component summary scores were associated with higher satisfaction, with correlation coefficients ranging from 0.27 to 0.49. On multivariate analysis, patients with higher preoperative ASES scores were less satisfied after surgery (P = .005). In addition, patients with worse VAS fatigue (P = .011) and SF-12 mental (P = .034) and physical (0.011) component summary scores preoperatively had lower satisfaction. CONCLUSION: Improvements in pain and outcome scores are associated with increased satisfaction. Patients with higher shoulder function, worse physical health, and worse mental health prior to surgery are more likely to have lower satisfaction after RSA.


Assuntos
Artroplastia do Ombro , Nível de Saúde , Saúde Mental , Satisfação do Paciente , Articulação do Ombro/fisiopatologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Artroplastia do Ombro/efeitos adversos , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Período Pós-Operatório , Período Pré-Operatório , Qualidade de Vida , Estudos Retrospectivos , Articulação do Ombro/cirurgia , Dor de Ombro/etiologia , Resultado do Tratamento , Escala Visual Analógica
19.
J Shoulder Elbow Surg ; 29(11): 2395-2405, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32669200

RESUMO

BACKGROUND: The purpose was to analyze the influence of deltoid lengthening due to different implant designs and anatomic variations of the acromion and scapular spine (SS) in the parasagittal plane on strain patterns after reverse shoulder arthroplasty (RSA). METHODS: Ten cadaveric shoulders with strain rosettes placed on the surface of the acromial body (Levy II) and SS (Levy III) were tested using a shoulder simulator. RSA using humeral onlay (+3, +5, +8, +10, +13 mm) and glenosphere lateralization (0, +6 mm) was performed. Arm lengthening and magnitude of strain on acromion/SS were measured. The length of deltoid was assessed using validated computer modeling. Anatomic variance of the SS angle and position of acromion in relation to the scapular plane was examined. For comparison of strain as a function of deltoid lengthening, 25 mm was used as a threshold value for comparison based on previous literature demonstrating a decrease in Constant score and active anterior elevation in patients with arm lengthening >25 mm. RESULTS: At maximal deltoid lengthening (30.8 mm), average strains were 1112 µÎµ (acromion) and 1165 µÎµ (SS) (P < .01). There was an 82.6% increase in acromial strain at maximum lengthening compared with 25 mm (P = .02) and a strain increase of 79 µÎµ/mm deltoid lengthening above a threshold of 25 mm. The strain results delineated 2 anatomic groups: 5 of 10 specimens (group A) showed higher strain on SS (1445 µÎµ) vs. acromion (862 µÎµ, P = .02). Group A had a more posteriorly oriented acromion, whereas group B was anteriorly oriented (P < .001). CONCLUSION: Deltoid lengthening above 25 mm produced large strains on the acromion/SS. Anatomic variation may indicate that as the acromion is more posteriorly oriented, the SS takes more strain from the deltoid vs. the acromion. Our study's data may help surgeons identify a high-risk population for increased strain patterns after RSA.


Assuntos
Acrômio/anatomia & histologia , Artroplastia do Ombro , Músculo Deltoide/fisiopatologia , Desenho de Prótese , Articulação do Ombro/fisiopatologia , Acrômio/fisiopatologia , Acrômio/cirurgia , Adulto , Variação Anatômica , Fenômenos Biomecânicos , Cadáver , Simulação por Computador , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Articulação do Ombro/cirurgia , Prótese de Ombro , Estresse Mecânico
20.
Muscle Nerve ; 59(2): 247-249, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30291636

RESUMO

INTRODUCTION: The purpose of this study was to determine whether surgical arthroscopic decompression or ultrasound-guided aspiration of a paralabral cyst would result in suprascapular nerve recovery from axonal regeneration based on electrodiagnostic testing. METHODS: Nine patients with preoperative electromyography (EMG) evidence of suprascapular neuropathy due to paralabral cysts at the suprascapular or spinoglenoid notch were prospectively studied. Eight patients underwent arthroscopic surgical decompression, and 1 patient underwent ultrasound-guided aspiration. Postoperative EMG was performed in all patients to evaluate nerve regeneration. RESULTS: Three (33%) patients had cysts at the suprascapular notch, whereas 6 (67%) patients had cysts at the spinoglenoid notch. All patients showed complete electrophysiological recovery after decompression. DISCUSSION: Decompression of paralabral cysts at the suprascapular or spinoglenoid notch resulted in postoperative EMG evidence of nerve recovery. Long-term studies with a greater number of patients are required to elucidate time to recovery. Muscle Nerve 59:247-249, 2019.


Assuntos
Descompressão Cirúrgica/métodos , Eletromiografia , Síndromes de Compressão Nervosa/cirurgia , Recuperação de Função Fisiológica/fisiologia , Adulto , Cistos/complicações , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Síndromes de Compressão Nervosa/etiologia , Estudos Prospectivos , Ombro/inervação , Articulação do Ombro , Resultado do Tratamento , Escala Visual Analógica
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa