Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 35
Filtrar
1.
Echocardiography ; 39(2): 166-177, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-35026051

RESUMO

OBJECTIVES: Reverse flow Retrograde flow (RF) of blood in the aortic isthmus can be observed in different types of fetal heart disease (FHD), including abnormalities in heart structure and function. This study sought to investigate the relationship between RF and blood flow parameters, and develop a computational fluid dynamics (CFD) model to understand the mechanisms underlying this observation. MATERIAL AND METHODS: A total of 281 fetuses (gestational age [GA] 26.6±.3 weeks) with FHD and 2803 normal fetuses (GA: 26.1±.1 weeks) by fetal echocardiography collected from May 2016 to December 2018. Principal component analysis (PCA) was performed to find the relationship and the CFD model reconstructed from 3D/4D spatio-temporal image correlation (STIC) images to simulate hemodynamics. RESULTS: There was a significant difference in the percentages of RF between the study (80/201 (39%)) and control (29/2803 (1%)) groups (p < 0.05). The RF occur when the aorta flow rate (left heart) is reduced to 60% by CFD stimulation. Pearson correlation analysis showed significant correlations between flow rate and wall shear stress(WSS) (r = .883, p = 0.047) variables at the AI. CONCLUSION: Volumetric flow rate of AO or left heart was the main component of the cause of RF. The hemodynamics of the cardiovascular system have highly complex behavior hinge on the turbulent nature of circulating blood flow.


Assuntos
Cardiopatias , Hidrodinâmica , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/fisiologia , Velocidade do Fluxo Sanguíneo , Feminino , Coração Fetal/diagnóstico por imagem , Hemodinâmica/fisiologia , Humanos , Lactente , Gravidez , Análise de Componente Principal
2.
Pediatr Cardiol ; 41(5): 1021-1030, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32377893

RESUMO

Apicocaval juxtaposition (ACJ) is a rare form of viscerocardiac malpositions in association with single-ventricle congenital heart defects. The Fontan surgery is the common palliation, and possible surgical options include ipsilateral, contralateral, and intra-atrial conduits. Concerns include lower hemodynamic performances or risks of conduit compression by the cardiac mass. This study investigates the hemodynamics and clinical outcomes of ACJ patients and potential surgical improvements. Ten consecutive ACJ patients were included, along with a reference cohort of ten non-ACJ patients. Magnetic resonance images were acquired at 6 ± 0.6 year follow-up for anatomical analysis and hemodynamic assessments using computational fluid dynamics. Metrics of interest are deformation index (DI), indexed power loss (iPL), and hepatic flow distribution (HFDoff). A "virtual" surgery was performed to explore potential hemodynamic improvements using a straightened conduit. DI for ACJ patients fell within the DI range of non-ACJ patients. Contralateral conduits had insignificantly higher iPL (0.070 [0.032,0.137]) than ipsilateral conduits (0.041 [0.013,0.095]) and non-ACJ conduits (0.034 [0.011,0.061]). HFDoff was similar for the ipsilateral (21 [12,35]), contralateral (26 [7,41]), and non-ACJ Fontan conduits (17 [0,48]). Virtual surgery demonstrated that a straightened conduit reduced HFDoff and iPL for the contralateral and ipsilateral conduits, potentially leading to improved clinical outcomes. In this limited sample, the hemodynamic performance of ACJ patients was not significantly different from their non-ACJ counterparts. The use of a straightened conduit option could potentially improve patient outcomes. Additionally, the fear of significant compression of conduits for ACJ patients was unsupported.


Assuntos
Técnica de Fontan/métodos , Cardiopatias Congênitas/cirurgia , Adolescente , Estudos de Casos e Controles , Criança , Feminino , Técnica de Fontan/efeitos adversos , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/fisiopatologia , Ventrículos do Coração/anormalidades , Ventrículos do Coração/cirurgia , Hemodinâmica , Humanos , Imageamento por Ressonância Magnética , Masculino , Artéria Pulmonar/patologia , Artéria Pulmonar/cirurgia
3.
J Biomech Eng ; 139(6)2017 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-28418512

RESUMO

The Fontan procedure is a common palliative intervention for sufferers of single ventricle congenital heart defects that results in an anastomosis of the venous return to the pulmonary arteries called the total cavopulmonary connection (TCPC). Local TCPC and global Fontan circulation hemodynamics are studied with in vitro circulatory models because of hemodynamic ties to Fontan patient long-term complications. The majority of in vitro studies, to date, employ a rigid TCPC model. Recently, a few studies have incorporated flexible TCPC models, but provide no justification for the model material properties. The method set forth in this study successfully utilizes patient-specific flow and pressure data from phase contrast magnetic resonance images (PCMRI) (n = 1) and retrospective pulse-pressure data from an age-matched patient cohort (n = 10) to verify the compliance of an in vitro TCPC model. These data were analyzed, and the target compliance was determined as 1.36 ± 0.78 mL/mm Hg. A method of in vitro compliance testing and computational simulations was employed to determine the in vitro flexible TCPC model material properties and then use those material properties to estimate the wall thickness necessary to match the patient-specific target compliance. The resulting in vitro TCPC model compliance was 1.37 ± 0.1 mL/mm Hg-a value within 1% of the patient-specific compliance. The presented method is useful to verify in vitro model accuracy of patient-specific TCPC compliance and thus improve patient-specific hemodynamic modeling.


Assuntos
Artéria Pulmonar/fisiopatologia , Veias Pulmonares/fisiopatologia , Complacência (Medida de Distensibilidade) , Técnica de Fontan , Cardiopatias Congênitas/fisiopatologia , Cardiopatias Congênitas/cirurgia , Hemodinâmica , Humanos , Modelagem Computacional Específica para o Paciente , Artéria Pulmonar/cirurgia , Veias Pulmonares/cirurgia
4.
JACC Case Rep ; 10: 101760, 2023 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-36974056

RESUMO

The authors report a closed-chest, transcatheter large-vessel connection (hepatic conduit to azygous vein) to reverse pulmonary arteriovenous malformations in a 10-year-old patient after Fontan for heterotaxy/interrupted inferior vena cava, with an increase in oxygen saturation from 78% to 96%. Computational fluid dynamics estimated a 14-fold increase in hepatic blood flow to the left pulmonary artery (from 1.3% to 14%). (Level of Difficulty: Advanced.).

5.
Materials (Basel) ; 15(9)2022 May 05.
Artigo em Inglês | MEDLINE | ID: mdl-35591636

RESUMO

This paper provides a review of engineering applications and computational methods used to analyze the dynamics of heart valve closures in healthy and diseased states. Computational methods are a cost-effective tool that can be used to evaluate the flow parameters of heart valves. Valve repair and replacement have long-term stability and biocompatibility issues, highlighting the need for a more robust method for resolving valvular disease. For example, while fluid-structure interaction analyses are still scarcely utilized to study aortic valves, computational fluid dynamics is used to assess the effect of different aortic valve morphologies on velocity profiles, flow patterns, helicity, wall shear stress, and oscillatory shear index in the thoracic aorta. It has been analyzed that computational flow dynamic analyses can be integrated with other methods to create a superior, more compatible method of understanding risk and compatibility.

6.
Front Cardiovasc Med ; 9: 869259, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35811698

RESUMO

Background: A clinical study comparing the hemodynamic outcomes of transcatheter mitral valve replacement (TMVR) with vs. without Laceration of the Anterior Mitral leaflet to Prevent Outflow Obstruction (LAMPOON) has never been designed nor conducted. Aims: To quantify the hemodynamic impact of LAMPOON in TMVR using patient-specific computational (in silico) models. Materials: Eight subjects from the LAMPOON investigational device exemption trial were included who had acceptable computed tomography (CT) data for analysis. All subjects were anticipated to be at prohibitive risk of left ventricular outflow tract (LVOT) obstruction from TMVR, and underwent successful LAMPOON immediately followed by TMVR. Using post-procedure CT scans, two 3D anatomical models were created for each subject: (1) TMVR with LAMPOON (performed procedure), and (2) TMVR without LAMPOON (virtual control). A validated computational fluid dynamics (CFD) paradigm was then used to simulate the hemodynamic outcomes for each condition. Results: LAMPOON exposed on average 2 ± 0.6 transcatheter valve cells (70 ± 20 mm2 total increase in outflow area) which provided an additional pathway for flow into the LVOT. As compared to TMVR without LAMPOON, TMVR with LAMPOON resulted in lower peak LVOT velocity, lower peak LVOT gradient, and higher peak LVOT effective orifice area by 0.4 ± 0.3 m/s (14 ± 7% improvement, p = 0.006), 7.6 ± 10.9 mmHg (31 ± 17% improvement, p = 0.01), and 0.2 ± 0.1 cm2 (17 ± 9% improvement, p = 0.002), respectively. Conclusion: This was the first study to permit a quantitative, patient-specific comparison of LVOT hemodynamics following TMVR with and without LAMPOON. The LAMPOON procedure achieved a critical increment in outflow area which was effective for improving LVOT hemodynamics, particularly for subjects with a small neo-left ventricular outflow tract (neo-LVOT).

7.
Ann Thorac Surg ; 114(3): 841-847, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35120878

RESUMO

BACKGROUND: Despite favorable short-term outcomes, Fontan palliation is associated with comorbidities and diminished quality of life (QOL) in the years after completion. We hypothesized that poor Fontan hemodynamics and ventricular function are associated with worse QOL. METHODS: This was a single-center study of Fontan survivors aged more than 12 years. Subjects completed a cardiac magnetic resonance scan and QOL questionnaire. Cardiac magnetic resonance-derived variables included Fontan geometry, and hemodynamics. Computational fluid dynamics simulations quantified power loss, pressure drop, and total cavopulmonary connection resistance across the Fontan. Quality of life was assessed by completion of the Pediatric Quality of Life Inventory. Longitudinal and cross-sectional comparisons were made between cardiac magnetic resonance and computational fluid dynamics parameters with patient-reported QOL. RESULTS: We studied 77 Fontan patients, median age 19.7 years (interquartile range, 17.1 to 23.6), median time from Fontan completion 16 years (interquartile range, 13 to 20). Longitudinal data were available for 48 patients; median time between cardiac magnetic resonance and QOL was 8.1 years (interquartile range, 7 to 9.4). Median patient-reported Pediatric Quality of Life Inventory total score was 80 (interquartile range, 67.4 to 88). Greater power loss and smaller left pulmonary artery diameter at baseline were associated with worse QOL at follow-up. Greater pressure drop was associated with worse QOL at the same time point. CONCLUSIONS: For Fontan survivors, measures of computational fluid dynamics hemodynamics and geometry are associated with worse QOL. Interventional strategies targeted at optimizing the Fontan may improve QOL.


Assuntos
Técnica de Fontan , Cardiopatias Congênitas , Adolescente , Adulto , Criança , Estudos Transversais , Cardiopatias Congênitas/cirurgia , Hemodinâmica , Humanos , Artéria Pulmonar/cirurgia , Qualidade de Vida , Adulto Jovem
8.
Eur Heart J Cardiovasc Imaging ; 23(5): 650-662, 2022 04 18.
Artigo em Inglês | MEDLINE | ID: mdl-34009283

RESUMO

AIMS: To characterize the dynamic nature of the left ventricular outflow tract (LVOT) geometry and flow rate in patients following transcatheter mitral valve replacement (TMVR) with anterior leaflet laceration (LAMPOON) and derive insights to help guide future patient selection. METHODS AND RESULTS: Time-resolved LVOT geometry and haemodynamics were analysed with post-procedure computed tomography and echocardiography in subjects (N = 19) from the LAMPOON investigational device exemption trial. A novel post hoc definition for LVOT obstruction was employed to account for systolic flow rate and quality of life improvement [obstruction was defined as LVOT gradient >30 mmHg or LVOT effective orifice area (EOA) ≤1.15 cm2]. The neo-LVOT and skirt neo-LVOT were observed to vary substantially in area throughout systole (64 ± 27% and 25 ± 14% change in area, respectively). The peak systolic flow rate occurred most commonly just prior to mid-systole, while minimum neo-LVOT (and skirt neo-LVOT) area occurred most commonly in early-diastole. Subjects with LVOT obstruction (n = 5) had smaller skirt neo-LVOT values across systole. Optimal thresholds for skirt neo-LVOT area were phase-specific (260, 210, 200, and 180 mm2 for early-systole, peak flow, mid-systole, and end-systole, respectively). CONCLUSION: The LVOT geometry and flow rate exhibit dynamic characteristics following TMVR with LAMPOON. Subjects with LVOT obstruction had smaller skirt neo-LVOT areas across systole. The authors recommend the use of phase-specific threshold values for skirt neo-LVOT area to guide future patient selection for this procedure. LVOT EOA is a 'flow-independent' metric which has the potential to aid in characterizing LVOT obstruction severity.


Assuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Obstrução do Fluxo Ventricular Externo , Cateterismo Cardíaco/métodos , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Qualidade de Vida , Obstrução do Fluxo Ventricular Externo/diagnóstico por imagem , Obstrução do Fluxo Ventricular Externo/etiologia , Obstrução do Fluxo Ventricular Externo/cirurgia
9.
Cardiovasc Eng Technol ; 12(6): 618-630, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34114202

RESUMO

BACKGROUND: Cardiovascular simulations for patients with single ventricles undergoing the Fontan procedure can assess patient-specific hemodynamics, explore surgical advances, and develop personalized strategies for surgery and patient care. These simulations have not yet been broadly accepted as a routine clinical tool owing to a number of limitations. Numerous approaches have been explored to seek innovative solutions for improving methodologies and eliminating these limitations. PURPOSE: This article first reviews the current state of cardiovascular simulations of Fontan hemodynamics. Then, it will discuss the technical progress of Fontan simulations with the emphasis of its clinical impact, noting that substantial improvements have been made in the considerations of patient-specific anatomy, flow, and blood rheology. The article concludes with insights into potential future directions involving clinical validation, uncertainty quantification, and computational efficiency. The advancements in these aspects could promote the clinical usage of Fontan simulations, facilitating its integration into routine clinical practice.


Assuntos
Sistema Cardiovascular , Técnica de Fontan , Cardiopatias Congênitas , Cardiopatias Congênitas/cirurgia , Hemodinâmica , Humanos , Modelos Cardiovasculares
10.
Cardiovasc Eng Technol ; 12(6): 606-617, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-33931807

RESUMO

PURPOSE: Surgical planning has shown great potential for optimizing outcomes for patients affected by single ventricle (SV) malformations. Phase-contrast magnetic resonance imaging (PC-MRI) is the routine technique used for flow acquisition in the surgical planning paradigm. However, PC-MRI may suffer from possible artifacts in certain cases; furthermore, this technology may not be readily available for patients in low and lower-middle-income countries. Therefore, this study aims to investigate the effectiveness of using Doppler echocardiography (echo-Doppler) for flow acquisitions of SV surgical planning. METHODS: This study included eight patients whose blood flow data was acquired by both PC-MRI and echo-Doppler. A virtual surgery platform was used to generate two surgical options for each patient: (1) a traditional Fontan conduit and (2) a Y-graft. Computational fluid dynamics (CFD) simulations were conducted using the two flow acquisitions to assess clinically relevant hemodynamic metrics: indexed power loss (iPL) and hepatic flow distribution (HFD). RESULTS: Differences exist in flow data acquired by PC-MRI and echo-Doppler, but no statistical significance was obtained. Flow fields, therefore, exhibit discrepancies between simulations using flow acquisitions by PC-MRI and echo-Doppler. In virtual surgery, the two surgical options were ranked based on these metrics. No difference was observed in the ranking of surgical options between using different flow acquisitions. CONCLUSION: Doppler echocardiography is an adequate alternative approach to acquire flow data for SV surgical planning. This finding encourages broader usage of SV surgical planning with echo-Doppler when MRI may present artifacts or is not available, especially in low and lower-middle-income countries.


Assuntos
Ecocardiografia Doppler , Cardiopatias Congênitas , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/cirurgia , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/cirurgia , Hemodinâmica , Humanos , Imageamento por Ressonância Magnética
11.
Semin Thorac Cardiovasc Surg ; 33(3): 816-823, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33662555

RESUMO

This hemodynamic feasibility study examined total cavopulmonary connection (TCPC) designs connecting the extracardiac conduit to the anterior surface of pulmonary arteries (PAs) or superior vena cava (SVC) rather than to the inferior PA surface (traditional TCPC). The study involved twenty-five consecutive Fontan patients meeting inclusion criteria from a single institution. A virtual surgical platform mimicked the completed traditional TCPC and generated three anterior anastomosis designs: Anterior-PA, Middle-SVC, and SVC-Inn (Inn: innominate vein). Hemodynamic performance of anterior anastomosis designs was compared with the traditional TCPC regarding indexed power loss (iPL) and hepatic flow distribution (HFD). Compared to the traditional TCPC, the Anterior-PA design produces a similar iPL. The Middle-SVC design is also similar, though the iPL difference is positively correlated with the anastomosing height. The SVC-Inn design had significantly more iPL. The three anterior anastomosis designs did not have a significant difference in HFD (from traditional TCPC). Pulmonary flow distribution (PFD) has a stronger correlation with HFD from the anterior anastomosis designs than the traditional TCPC. This hemodynamic feasibility study examined anterior anastomosis, extracardiac TCPC designs that may offer surgeons clinical dexterity. The Anterior-PA design may be equivalent to the traditional TCPC. Fontan extracardiac conduit anastomosis just superior to the PAs (Middle-SVC) also preserves hemodynamic performance and avoids direct PA anastomosis. These designs could simplify surgical Fontan completion, and may particularly benefit patients requiring surgical dissection, having atypical PA orientation, or after PA stent angioplasty.


Assuntos
Técnica de Fontan , Cardiopatias Congênitas , Técnica de Fontan/efeitos adversos , Cardiopatias Congênitas/cirurgia , Hemodinâmica , Humanos , Pulmão , Artéria Pulmonar/cirurgia , Veia Cava Superior/cirurgia
12.
Ann Biomed Eng ; 49(6): 1449-1461, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33723704

RESUMO

In silico modeling has been proposed as a tool to simulate left ventricular (LV) outflow tract (LVOT) obstruction in patients undergoing transcatheter mitral valve replacement (TMVR). This study validated a simplified approach to simulate LV outflow hemodynamics in the setting of TMVR with anterior leaflet laceration, a clinical technique used to mitigate the risk of LVOT obstruction. Personalized, 3-dimensional computational fluid dynamics models were developed from computed tomography images of six patients who underwent TMVR with anterior leaflet laceration. LV outflow hemodynamics were simulated using the patient-specific anatomy and the peak systolic flow rate as boundary conditions. The peak outflow velocity, a clinically relevant hemodynamic metric, was extracted from each simulation (vsim-peak) and compared with the clinical measurement from Doppler echocardiography (vclin-peak) for validation. In silico models were successfully developed and implemented for all patients. The pre-processing time was 2 h per model and the simulation could be completed within 3 h. In three patients, the lacerated anterior leaflet exposed open cells of the transcatheter valve to flow. Good agreement was obtained between vsim-peak and vclin-peak (r = 0.97, p < 0.01) with average discrepancies of 5 ± 2% and 14 ± 1% for patients with exposed and unexposed cells of the transcatheter valve, respectively. The proposed in silico modeling paradigm therefore simulated LV outflow hemodynamics in a time-efficient manner and demonstrated good agreement with clinical measurements. Future studies should investigate the ability of this paradigm to support clinical applications.


Assuntos
Implante de Prótese de Valva Cardíaca , Ventrículos do Coração/fisiopatologia , Modelos Cardiovasculares , Modelagem Computacional Específica para o Paciente , Obstrução do Fluxo Ventricular Externo/fisiopatologia , Idoso , Idoso de 80 Anos ou mais , Circulação Coronária , Feminino , Próteses Valvulares Cardíacas , Hemodinâmica , Humanos , Hidrodinâmica , Lacerações , Pessoa de Meia-Idade , Valva Mitral/cirurgia , Reprodutibilidade dos Testes
13.
Biology (Basel) ; 9(12)2020 Nov 24.
Artigo em Inglês | MEDLINE | ID: mdl-33255292

RESUMO

Total cavopulmonary connection (TCPC) hemodynamics has been hypothesized to be associated with long-term complications in single ventricle heart defect patients. Rigid wall assumption has been commonly used when evaluating TCPC hemodynamics using computational fluid dynamics (CFD) simulation. Previous study has evaluated impact of wall compliance on extra-cardiac TCPC hemodynamics using fluid-structure interaction (FSI) simulation. However, the impact of ignoring wall compliance on the presumably more compliant intra-atrial TCPC hemodynamics is not fully understood. To narrow this knowledge gap, this study aims to investigate impact of wall compliance on an intra-atrial TCPC hemodynamics. A patient-specific model of an intra-atrial TCPC is simulated with an FSI model. Patient-specific 3D TCPC anatomies were reconstructed from transverse cardiovascular magnetic resonance images. Patient-specific vessel flow rate from phase-contrast magnetic resonance imaging (MRI) at the Fontan pathway and the superior vena cava under resting condition were prescribed at the inlets. From the FSI simulation, the degree of wall deformation was compared with in vivo wall deformation from phase-contrast MRI data as validation of the FSI model. Then, TCPC flow structure, power loss and hepatic flow distribution (HFD) were compared between rigid wall and FSI simulation. There were differences in instantaneous pressure drop, power loss and HFD between rigid wall and FSI simulations, but no difference in the time-averaged quantities. The findings of this study support the use of a rigid wall assumption on evaluation of time-averaged intra-atrial TCPC hemodynamic metric under resting breath-held condition.

14.
J Biomech ; 109: 109917, 2020 08 26.
Artigo em Inglês | MEDLINE | ID: mdl-32807331

RESUMO

The use of mechanical circulatory support for failing Fontan patients is an area of growing interest, as the increased life expectancy of these patients continues to be accompanied by numerous end-organ complications. In vitro work has shown positive results using the CentriMag device for right-sided Fontan support, however the generalizability across various patient anatomies and cannulations is unknown. Computational simulations are first validated against in vitro modeling, then used to assess generalizability and further explore hemodynamic metrics including relative pressure changes, hepatic flow distribution, wall shear stress and power added. Computational modeling matched previous in vitro work very well, with vessel flow rates and relative average pressure change each within 1%. Positive results were seen across all patient anatomies and cannulations. On average, pressure from the vena cava to pulmonary arteries increased by 5.4 mmHg corresponding to 32 mW of power added. Hepatic flow distribution and wall shear stress were within acceptable ranges, with an average hepatic flow distribution of 47% and all patients showing ≤ 1% of the total Fontan connection surface area at a wall shear stress above 150 Pa. The positive results previously seen using CentriMag as a right-sided Fontan support device were found to be repeatable across multiple patient anatomies and cannulations. While animal models and eventual patient studies will provide further insight into the efficacy of this support strategy, our findings here suggest this method may reproduce right heart function.


Assuntos
Técnica de Fontan , Cardiopatias Congênitas , Coração Auxiliar , Cateterismo , Hemodinâmica , Humanos , Modelos Cardiovasculares
15.
Ann Biomed Eng ; 48(8): 2204-2217, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32372365

RESUMO

The Fontan procedure is a common palliative surgery for congenital single ventricle patients. In silico and in vitro patient-specific modeling approaches are widely utilized to investigate potential improvements of Fontan hemodynamics that are related to long-term complications. However, there is a lack of consensus regarding the use of non-Newtonian rheology, warranting a systematic investigation. This study conducted in silico patient-specific modeling for twelve Fontan patients, using a Newtonian and a non-Newtonian model for each patient. Differences were quantified by examining clinically relevant metrics: indexed power loss (iPL), indexed viscous dissipation rate (iVDR), hepatic flow distribution (HFD), and regions of low wall shear stress (AWSS). Four sets of "non-Newtonian importance factors" were calculated to explore their effectiveness in identifying the non-Newtonian effect. No statistical differences were observed in iPL, iVDR, and HFD between the two models at the population-level, but large inter-patient variations exist. Significant differences were detected regarding AWSS, and its correlations with non-Newtonian importance factors were discussed. Additionally, simulations using the non-Newtonian model were computationally faster than those using the Newtonian model. These findings distinguish good importance factors for identifying non-Newtonian rheology and encourage the use of a non-Newtonian model to assess Fontan hemodynamics.


Assuntos
Técnica de Fontan , Hidrodinâmica , Modelos Cardiovasculares , Modelagem Computacional Específica para o Paciente , Adolescente , Criança , Feminino , Humanos , Masculino , Estudos Retrospectivos
16.
J Thorac Cardiovasc Surg ; 159(2): 652-661, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31399233

RESUMO

OBJECTIVE: The use of Y-grafts for Fontan completion is hypothesized to offer more balanced hepatic flow distribution (HFD) and decreased energy losses. The purpose of this study was to evaluate the hemodynamic performance of Y-grafts over time using serial cardiac magnetic resonance data and to compare their performance with extracardiac Fontan connections. METHODS: Ten Fontan patients with commercially available Y-graft connections and serial postoperative cardiac magnetic resonance data were included in this study. Patient-specific computational fluid dynamics simulations were used to estimate HFD and energy losses. Y-graft performance was compared with 3 extracardiac conduit Fontan groups (n = 10 for each) whose follow-up times straddle the Y-graft time points. RESULTS: Y-graft HFD became significantly more balanced over time (deviation from 50% decreased from 18% ± 14% to 8% ± 8%; P = .015). Total cavopulmonary connection resistance did not significantly change. Y-grafts at 3-year follow-up showed more balanced HFD than the extracardiac conduit groups at both the earlier and later follow-up times. Total cavopulmonary connection resistance was not significantly different between any Y-graft or extracardiac conduit group. CONCLUSIONS: Y-grafts showed significantly more balanced HFD over a 3-year follow-up without an increase in total cavopulmonary connection resistance, and therefore may be a valuable option for Fontan completion. Additional follow-up data at longer follow-up times are still needed to thoroughly characterize the potential advantages of Y-graft use.


Assuntos
Prótese Vascular , Técnica de Fontan , Hemodinâmica/fisiologia , Adolescente , Adulto , Criança , Pré-Escolar , Feminino , Técnica de Fontan/efeitos adversos , Técnica de Fontan/instrumentação , Técnica de Fontan/métodos , Técnica de Fontan/estatística & dados numéricos , Cardiopatias Congênitas/fisiopatologia , Cardiopatias Congênitas/cirurgia , Humanos , Masculino , Desenho de Prótese , Artéria Pulmonar/fisiologia , Artéria Pulmonar/cirurgia , Adulto Jovem
17.
J Cardiovasc Transl Res ; 13(4): 640-647, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-31732919

RESUMO

Fontan surgical planning ranks proposed surgical options according to their hemodynamics assessed by computational fluid dynamic (CFD) modeling. CFD commonly utilizes blood flow acquired under breath-holding (BH) conditions. Ignoring the free-breathing (FB) effect on blood flow waveforms may impact the ranking of surgical options. This study investigates such a potential impact by including ten Fontan patients who had blood flow acquisitions under both BH and FB conditions. A virtual surgery platform was used to generate two surgical options for each patient: (1) a traditional Fontan conduit and (2) a Y-graft. These options were ranked based on clinically relevant hemodynamic metrics: power loss (PL) and hepatic flow distribution (HFD). No difference was found in the ranking of options between using FB and BH flow acquisitions. The findings indicated that decision-making is not affected by the types of flow acquisition for Fontan surgical planning.


Assuntos
Tomada de Decisão Clínica , Diagnóstico por Computador , Técnica de Fontan , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/cirurgia , Imageamento por Ressonância Magnética , Modelagem Computacional Específica para o Paciente , Adolescente , Feminino , Técnica de Fontan/efeitos adversos , Cardiopatias Congênitas/fisiopatologia , Hemodinâmica , Humanos , Masculino , Seleção de Pacientes , Valor Preditivo dos Testes , Estudo de Prova de Conceito , Reoperação , Mecânica Respiratória , Estudos Retrospectivos , Adulto Jovem
18.
Ann Biomed Eng ; 48(10): 2400-2411, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32415483

RESUMO

Thrombosis in post-transcatheter aortic valve replacement (TAVR) patients has been correlated with flow stasis in the neo-sinus. This study investigated the effect of the post-TAVR geometry on flow stasis. Computed tomography angiography of 155 patients who underwent TAVR using a SAPIEN 3 were used to identify patients with and without thrombosis, and quantify thrombus volumes. Six patients with 23-mm SAPIEN 3 valves were then selected from the cohort and used to create patient-specific post-TAVR computational fluid dynamic models. Regions of flow stasis (%Volstasis, velocities below 0.05 m/s) were identified. The results showed that all post-TAVR anatomical measurements were significantly different in patients with and without thrombus, but only sinus diameter had a linear correlation with thrombus volume (r = 0.471, p = 0.008). A linear correlation was observed between %Volstasis and thrombus volume (r = 0.821, p = 0.007). The combination of anatomy and valve deployment created a unique geometry in each patient, which when combined with patient-specific cardiac output, resulted in distinct flow patterns. While parametric studies have shown individual anatomical or deployment metrics may relate to flow stasis, the combined effects of these metrics potentially contributes to the biomechanical environment promoting thrombosis, therefore hemodynamic studies of TAVR should account for these patient-specific factors.


Assuntos
Circulação Coronária , Modelos Cardiovasculares , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Angiografia por Tomografia Computadorizada , Simulação por Computador , Feminino , Humanos , Masculino , Trombose/diagnóstico por imagem , Trombose/fisiopatologia
19.
Ann Thorac Surg ; 109(6): 1904-1911, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-31734244

RESUMO

BACKGROUND: Liver fibrosis is a serious complication of single ventricle Fontan survivors. Its causes are of great interest, and potential solutions to halt or delay progression are needed. The purpose of this study is to investigate if prior hemodynamics and anatomy can predict liver fibrosis severity in these patients. METHODS: Twenty-one Fontan patients with cardiac magnetic resonance (CMR) data obtained greater than 1 year before liver biopsy data were included. Computational fluid dynamic simulations were performed to quantify total cavopulmonary connection (TCPC) flow dynamics using patient-specific anatomies and blood flow waveforms reconstructed from CMR data. Collagen deposition (a measure of liver fibrosis) was quantified by digital image analysis of Sirius red-stained slides. Statistical analyses were performed to investigate potential relationships between Fontan hemodynamics and liver fibrosis. RESULTS: With an average time of 6.7 ± 2.9 years (range, 2-11 years) between CMR and biopsy, TCPC resistance and left pulmonary artery stenosis showed significant, positive correlations with magnitude of liver fibrosis (r = 0.54, P = .026; and r = 0.55, P = .028, respectively). The change in inferior vena cava flow rate over time also showed a significant positive correlation with magnitude of liver fibrosis (r = 0.91, P = .001). CONCLUSIONS: TCPC resistance, left pulmonary artery stenosis, and increased inferior vena cava flow are positively associated with liver fibrosis after Fontan operation and hold promise as important predictors of hepatic decline. These findings encourage preprocedural planning and interventional strategies to improve TCPC performance and reduce vessel stenosis. Further investigation is warranted to design the ideal Fontan circulation and optimize flow dynamics to reduce the risk of liver fibrosis.


Assuntos
Técnica de Fontan/efeitos adversos , Previsões , Cardiopatias Congênitas/diagnóstico , Cirrose Hepática/diagnóstico , Fígado/diagnóstico por imagem , Imagem Cinética por Ressonância Magnética/métodos , Complicações Pós-Operatórias , Adolescente , Biópsia , Criança , Pré-Escolar , Feminino , Seguimentos , Cardiopatias Congênitas/cirurgia , Humanos , Cirrose Hepática/etiologia , Masculino , Período Pré-Operatório , Adulto Jovem
20.
Ann Biomed Eng ; 47(6): 1422-1434, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30859434

RESUMO

Computational modeling can be used to improve understanding of tricuspid valve (TV) biomechanics and supplement knowledge gained from benchtop and large animal experiments. The aim of this study was to develop a computational model of the TV using high resolution micro-computed tomography (µCT) imaging and fluid-structure interaction simulations. A three-dimensional TV model, incorporating detailed leaflet and chordal geometries, was reconstructed from µCT images of an excised porcine TV obtained under diastolic conditions. The leaflets were described using non-linear stress-strain relations and chordal properties were iteratively adjusted until valve closure was obtained. The leaflet coaptation zone obtained from simulation of valve closure was validated against µCT images of the TV captured at peak systole. The computational model was then used to simulate a regurgitant TV morphology and investigate changes in closure dynamics. Overall, the mean stresses in the leaflet belly region and the chordae tendinae of the regurgitant TV were 7% and 3% higher than the same regions of the normal TV. The maximum principal strain in the leaflet belly of the regurgitant TV was also 9% higher than the same regions of the normal TV. It is anticipated that this computational model can be used in future studies for further understanding of TV biomechanics and associated percutaneous repairs.


Assuntos
Modelos Cardiovasculares , Valva Tricúspide/fisiologia , Animais , Simulação por Computador , Análise de Elementos Finitos , Suínos , Valva Tricúspide/diagnóstico por imagem , Microtomografia por Raio-X
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa