Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Contracept X ; 5: 100100, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37823034

RESUMO

Objectives: This study aimed to evaluate and compare local tolerability of investigational drug TV-46046 and reference drug Depo-subQ Provera 104, both containing medroxyprogesterone acetate (MPA) as an active ingredient. Study design: We conducted a randomized, crossover, single-center study. Twenty-seven healthy women aged 25 to 47 years at low risk of pregnancy received a subcutaneous injection of each of the four study drugs (120 mg/0.3 mL of TV-46046, 60 mg/0.3 mL of diluted TV-46046, 0.3 mL of TV-46046 placebo, and 104 mg/0.65 mL of Depo-subQ 104) in different quadrants of the abdomen. We assessed local tolerability by occurrence of injection site reactions (ISRs), as well as injection site pain and overall safety for at least 9 months postinjections. Results: Of a total of 108 study injections, three injections were partial due to needle blockage. We observed a total of 30 ISRs following 105 full-dose injections, including hypopigmentation (n = 24), bruising (n = 4), and atrophy/dimple (n = 2). Eleven cases of hypopigmentation occurred following 25 full-dose injections of undiluted TV-46046 (44.0%), six following 27 full-dose injections of diluted TV-46046 (22.2%), and seven following 26 full-dose injections of Depo-subQ 104 (26.9%). Hypopigmentations occurred on average 8 months postinjection. Injection pain was minimal and dissipated quickly after all four injections. Conclusions: Subcutaneous administration of MPA in a suspension formulation is associated with the delayed onset of hypopigmentation at the site of injection. Although not statistically significant, the rate of ISRs was over 60% higher for undiluted TV-46046 compared to Depo-subQ 104. This difference bears careful monitoring in future studies of TV-46046. Implications: From a safety standpoint, investigational drug TV-46046 is appropriate for further clinical testing as a 6-month contraceptive injectable. The previously underreported hypopigmentation associated with subcutaneous administration of MPA warrants further investigation and acceptability assessment among users of existing Depo-subQ 104 as well as careful monitoring of local tolerability of TV-46046 in future clinical trials. Trial registration: Registered at clinicaltrials.gov no: NCT02817464.

2.
Contraception ; 77(2): 130-7, 2008 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-18226678

RESUMO

BACKGROUND: The purpose of this study was to assess the functional performance of the BufferGel Duet, a buffering microbicide and spermicide gel applied to the cervix and vagina by a novel applicator that also serves as a mechanical barrier. STUDY DESIGN: This was a noncomparative Phase I safety trial in 30 healthy couples, aged 20-50 years, at low risk for sexually transmitted infections, who agreed to use the gel-device combination twice in 1 week and respond to detailed questionnaires about their experience. The female participants were examined with colposcopy before and 6-18 h after using the second device. RESULTS: Based on written instructions alone, 25 women successfully placed and 28 women successfully removed the device. Three women reported feeling the device dislodge around the time of intercourse. The product was equally acceptable to both men and women. Most users concluded that intercourse was the same or better with the device than with no product. About 73% would choose Duet over male condoms, and no one preferred the standard diaphragm. Colposcopic findings were noted in 79% of women with external genital findings (9) or cervicovaginal peeling (18) predominating. Only one finding breached the epithelium. Most product-related adverse events were mild (10/11) and confined to the genitourinary tract. CONCLUSIONS: The successful placements and acceptability suggest that further product development is warranted and could target over-the-counter use. During increased duration of use or more frequent dosing, cervicovaginal monitoring is advised based on the extent of peeling and external colposcopic findings in this short-term study.


Assuntos
Antivirais/administração & dosagem , Dispositivos Anticoncepcionais Femininos , Satisfação do Paciente , Espermicidas/administração & dosagem , Vagina/patologia , Resinas Acrílicas , Adulto , Colposcopia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Segurança , Infecções Sexualmente Transmissíveis/prevenção & controle , Resultado do Tratamento , Sistema Urogenital/efeitos dos fármacos , Vagina/citologia , Vagina/lesões , Cremes, Espumas e Géis Vaginais/administração & dosagem , Cremes, Espumas e Géis Vaginais/efeitos adversos
3.
Contraception ; 94(5): 512-520, 2016 11.
Artigo em Inglês | MEDLINE | ID: mdl-27259675

RESUMO

OBJECTIVE: The primary objective of this pilot study is to determine and compare the residence time in the vagina of biomarkers of semen exposure for up to 15 days post exposure. The biomarkers are prostate-specific antigen (PSA), Y chromosome DNA, the sex determining region of the Y chromosome (SRY) and testis-specific protein Y-encoded 4 (TSPY4). The secondary objectives are to determine if biomarker concentrations differed between intercourse and inoculation groups, to establish whether the sampling frequency post exposure affected biomarker concentrations and decay profile and to determine if biomarker concentrations in vaginal swabs obtained by the participant at home were similar to swabs obtained by the nurse in the clinic. STUDY DESIGN: We randomized healthy women to unprotected intercourse (n=17) versus vaginal inoculation with the male partner's semen in the clinic (n=16). Women were then further randomized to have vaginal swabs obtained at either 7 or 4 time points after semen exposure, up to 15 days post exposure, either obtained at home by the participant or in the clinic by the research nurse. RESULTS: PSA and SRY were markers of recent semen exposure. TSPY4 was detectable in approximately 50% of participants at 15 days post exposure. Unprotected intercourse resulted in significantly higher concentrations of select biomarkers. Sampling frequency and home versus clinic sampling had no significant effect on biomarker concentrations. CONCLUSIONS: Objective biomarkers of recent or distant semen exposure may have great utility for verifying protocol compliance in a variety of clinical trials.


Assuntos
Proteínas de Ciclo Celular/análise , Antígeno Prostático Específico/análise , Sêmen/fisiologia , Proteína da Região Y Determinante do Sexo/análise , Vagina/fisiologia , Adulto , Biomarcadores/análise , Cromossomos Humanos Y , Coito , Feminino , Voluntários Saudáveis , Humanos , Masculino , Projetos Piloto , Método Simples-Cego , Fatores de Tempo
4.
Contraception ; 89(3): 197-203, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24439674

RESUMO

BACKGROUND: Sino-implant (II) is a two-rod subcutaneous contraceptive implant used up to 4 years, containing 150 mg of levonorgestrel. We conducted two observational studies of Sino-implant (II) to evaluate its performance in routine service delivery settings. METHODS: We enrolled 1326 women age 18-44 who had Sino-implant (II) inserted at clinics in Pakistan and Kenya. Women were followed-up using either an active or passive follow-up scheme in each study. Study outcomes were: one-year cumulative pregnancy and discontinuation rates; rates of insertion and removal complications; adverse event and side effect rates; reasons for discontinuation; and implant acceptability and satisfaction with clinic services. RESULTS: A total of 754 women returned for at least one follow-up visit. The overall Pearl pregnancy rate was 0.4 per 100 woman-years [95% confidence interval (CI) 0.1, 0.9] resulting from 1 confirmed post-insertion pregnancy in Kenya and 4 in Pakistan. Country-specific Pearl rates were 0.2 (95% CI 0.0, 0.9) in Kenya and 0.6 (95% CI 0.2, 1.6) in Pakistan. The total cumulative 12-month probability of removal was 7.6% (95% CI 6.1, 9.1), with country-specific removal probabilities of 3.7% in Kenya (95% CI 2.1, 5.3) and 10.8% in Pakistan (95% CI 8.5, 13.2). Four serious adverse events occurred in Kenya and none occurred in Pakistan; one SAE (an ectopic pregnancy) was possibly related to Sino-implant (II). Most women in both countries said they would recommend the implant to others. CONCLUSION: The results from these studies reveal high effectiveness and favorable safety and acceptability during the first year of use of Sino-implant. IMPLICATION: The favorable Sino-implant (II) findings from Kenya and Pakistan provide further evidence from disparate regions that Sino-implant (II) is safe, effective and acceptable during routine service delivery.


Assuntos
Anticoncepcionais Femininos/administração & dosagem , Implantes de Medicamento , Levanogestrel/administração & dosagem , Adolescente , Adulto , Implantes de Medicamento/efeitos adversos , Feminino , Humanos , Quênia , Levanogestrel/efeitos adversos , Paquistão , Satisfação do Paciente , Gravidez , Estudos Prospectivos , Adulto Jovem
5.
Contraception ; 89(3): 215-21, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24388695

RESUMO

BACKGROUND: An oral dose of 0.75 mg levonorgestrel (LNG) taken shortly after sex was marketed as a routine, nonemergency contraceptive method until the 1990s. Because a hormonal method used only at the time of intercourse may be desirable for women who have infrequent sex, we conducted a study to reevaluate the potential of pericoital LNG as a primary means of contraception. METHODS: We enrolled women aged 18-45 years in Brazil and the USA who expected to have sex 1-4 days per month for 6.5 months. Participants were instructed to take one tablet 0.75 mg LNG within 24 h before or after sex, with no more than one dose in any 24-h period. The primary efficacy measure was the Pearl Index among women aged 18-35 years. RESULTS: The study was stopped after 72 of the planned 300 participants were enrolled due to slow recruitment and related feasibility considerations. In the primary analysis, three pregnancies occurred during 13.4 woman-years of follow-up, resulting in a Pearl Index of 22.4 (95% confidence interval, 4.6-65.4). No serious adverse events were reported, and vaginal bleeding patterns were generally acceptable. CONCLUSIONS: Our estimated Pearl Index was noticeably higher than expected from previous research of LNG for pericoital contraception. Although the regimen was safe and generally acceptable, the study was challenged by slow enrollment and curtailed person-years of follow-up, resulting in poor precision for the estimated treatment effect. Future research may inform whether our results are symptomatic of the regimen, study design or characteristics of the populations from which we recruited. IMPLICATIONS: Our study failed to confirm prior data suggesting that 0.75 mg LNG for pericoital contraception could be more effective than typical use of barrier methods among women having infrequent sex. Characterizing populations most likely to adhere to, and benefit from, pericoital regimens is essential to future research on these methods.


Assuntos
Coito , Anticoncepcionais Femininos/administração & dosagem , Levanogestrel/administração & dosagem , Adolescente , Adulto , Brasil , Anticoncepção Pós-Coito , Anticoncepcionais Femininos/efeitos adversos , Feminino , Humanos , Levanogestrel/efeitos adversos , Pessoa de Meia-Idade , Gravidez , Estudos Prospectivos , Estados Unidos , Adulto Jovem
6.
Contraception ; 86(2): 106-9, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22240176

RESUMO

BACKGROUND: Concern about quinacrine lingers because of its carcinogenic effects in rats. We describe results of long-term follow-up of women who underwent quinacrine pellet sterilization in Chile between 1977 and 1989 (N=1492). METHODS: We interviewed the women or relatives in five rounds of data collection between 1991-1993 and 2006-2007, and reviewed hospital records. Median follow-up was 18.5 years; total person-time was 23,894 woman-years. This analysis focuses on pelvic and abdominal surgeries and conditions. We used survival analysis to estimate the 15-year cumulative probability of hysterectomy, other pelvic surgical procedures and relevant adverse events. RESULTS: Uterine fibroids were by far the most common gynecologic condition, reported by 11% of the cohort. Surgical procedures were recorded for 15% of the cohort; hysterectomy was the most frequent procedure (10%), followed by salpingectomy (2%). The 15-year probability of any pelvic or abdominal procedure was 14.7 per 100 women (95% confidence interval 12.4-16.9). The probability of hysterectomy was 9.3 per 100 women (95% confidence interval 7.4-11.1). Number of quinacrine insertions had little impact on the probabilities. CONCLUSION: During long-term follow-up of women who received quinacrine pellets for nonsurgical sterilization, the incidence of noncancer adverse outcomes was not unusually high, and no alarming patterns emerged.


Assuntos
Neoplasias dos Genitais Femininos/epidemiologia , Pelve/cirurgia , Quinacrina/efeitos adversos , Substâncias para o Controle da Reprodução/efeitos adversos , Esterilização Reprodutiva/efeitos adversos , Carcinógenos/toxicidade , Chile/epidemiologia , Estudos de Coortes , Relação Dose-Resposta a Droga , Implantes de Medicamento , Família , Feminino , Seguimentos , Neoplasias dos Genitais Femininos/induzido quimicamente , Neoplasias dos Genitais Femininos/cirurgia , Humanos , Incidência , Estimativa de Kaplan-Meier , Leiomioma/induzido quimicamente , Leiomioma/epidemiologia , Leiomioma/cirurgia , Prontuários Médicos , Pessoa de Meia-Idade , Quinacrina/administração & dosagem , Substâncias para o Controle da Reprodução/administração & dosagem , Útero
7.
Contraception ; 81(1): 75-8, 2010 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-20004277

RESUMO

BACKGROUND: Dating back to the 1970s, thousands of women worldwide have voluntarily been sterilized with transcervical insertion of quinacrine pellets. The safety and efficacy of the technology are still being assessed today; in particular, better estimates on the incidence of human cancers are now feasible. METHODS: We conducted a cohort study of 1492 women in Santiago and Valdivia, Chile, who received transcervical quinacrine pellets for contraceptive sterilization between 1977 and 1989. We periodically interviewed women with the last interviews in 2006-2007 and reviewed their medical records. We calculated age and site-specific incidence of invasive cancers and compared the observed cases to the number of expected cases based on data from the Cali, Colombia, cancer registry, gathered by the International Agency for Research on Cancer. RESULTS: During 23,894 person-years of follow-up, 41 invasive cancers were identified, including 16 new cases that had occurred since the previous analysis. Ten cases of cervical cancer were observed, compared with 12.1 expected. Since the initial study's confirmation of a single case of leiomyosarcoma, no other uterine cancers have been diagnosed. We would expect 2.0 uterine cancers during this number of observed women-years. One case of ovarian cancer was diagnosed, compared with 3.1 expected. CONCLUSION: Rates of cancer among women exposed to intrauterine quinacrine are similar to population-based rates.


Assuntos
Neoplasias do Endométrio/epidemiologia , Neoplasias Ovarianas/epidemiologia , Quinacrina/administração & dosagem , Esterilização Reprodutiva/efeitos adversos , Neoplasias do Colo do Útero/epidemiologia , Chile , Estudos de Coortes , Bases de Dados Factuais , Feminino , Seguimentos , Humanos , Incidência , Entrevistas como Assunto , Prontuários Médicos , Prevalência
8.
Contraception ; 78(6): 465-73, 2008 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-19014792

RESUMO

BACKGROUND: Only one female condom [FC1 Female Condom (FC1)] is currently marketed, but it is poorly utilized, perhaps due to difficulty with insertion, discomfort and suboptimal functional performance during intercourse. The Program for Appropriate Technology in Health (PATH) Woman's Condom (WC) was developed in an effort to overcome these obstacles. STUDY DESIGN: This was a randomized crossover study to evaluate the functional performance, safety and acceptability of the FC1 and WC. Seventy-five couples were assigned to one of two condom use sequences (WC/FC1 or FC1/WC) at three centers. Four condoms of the first type were used by couples in four acts of intercourse at home over a 2-4-week period. After a follow-up visit, these procedures were repeated with the second assigned condom type. In a substudy of participants (n=25), a colposcopy was performed prior and subsequent to the first condom use of each of the two condom types. Condom performance was evaluated by calculating measures of function from questionnaires completed by the couple after each condom use. Safety was evaluated by reported urogenital symptoms with a given condom during or immediately following condom use and colposcopic signs of genital irritation in the substudy. Acceptability of each given condom type was measured by questionnaire. RESULTS: Total condom failure (slippage, breakage, etc., divided by the number of female condoms opened) was 31% for the WC and 42% for the FC1. Total clinical failure (slippage, breakage, etc., divided by the number of female condoms used) was 17% for the WC and 24% for the FC1. The proportion of condom failures was 10.9 percentage points less, and the proportion of clinical failure 6.7 percentage points less, when couples used the WC compared to the FC1 [90% CI: -18.5 to -3.3 and -12.6 to -0.8, respectively). Fewer women reported symptoms of urogenital irritation when using the WC vs. the FC1 either overall or when analyzing each use of the condom [woman as unit: -20 percentage points (90% CI: -30.5 to -9.3); condom use as unit: -12.3 percentage points (90% CI: -18.0 to -6.7)]. A similar result was seen for signs of urogenital irritation [woman as unit: -20 percentage points (90% CI: -42.7 to 4.8)]. Among participants with a preference, WC was preferred over the FC1 by twice as many males and by 2.6 times as many females. CONCLUSIONS: While both female condoms were safe and acceptable in short-term use, the PATH Woman's Condom leads to less failure, was associated with fewer adverse events, and was more acceptable than the FC1 Female Condom.


Assuntos
Preservativos Femininos/estatística & dados numéricos , Comportamento do Consumidor , Falha de Equipamento/estatística & dados numéricos , Adulto , Coito , Colposcopia , Preservativos Femininos/efeitos adversos , Estudos Cross-Over , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Inquéritos e Questionários , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa