Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
1.
Comput Toxicol ; 17: 100144, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33681540

RESUMO

New approaches in toxicology based on in vitro methods and computational modelling offer considerable potential to improve the efficiency and effectiveness of chemical hazard and risk assessment in a variety of regulatory contexts. However, this presents challenges both for developers and regulatory assessors because often these two communities do not share the same level of confidence in a new approach. To address this challenge, various assessment frameworks have been developed over the past 20 years with the aim of creating harmonised and systematic approaches for evaluating new methods. These frameworks typically focus on specific methodologies and technologies, which has proven useful for establishing the validity and credibility of individual methods. However, given the increasing need to compare methods and combine their use in integrated assessment strategies, the multiplicity of frameworks is arguably becoming a barrier to their acceptance. In this commentary, we explore the concepts of model validity and credibility, and we illustrate how a set of seven credibility factors provides a method-agnostic means of comparing different kinds of predictive toxicology approaches. It is hoped that this will facilitate communication and cross-disciplinarity among method developers and users, with the ultimate aim of increasing the acceptance and use of predictive approaches in toxicology.

2.
Opt Lett ; 34(19): 3006-8, 2009 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-19794797

RESUMO

A holographic optical lithography setup with extremely small longitudinal spherical aberration is described. The setup is used for the fabrication of holographic diffractive optical elements intended to collect light emitted from a fluorescence spot located on a biochip surface. A key feature of the optical setup is its ability to simulate a point-source-like fluorescence spot. A detailed description of the setup together with its optical properties are provided. The fluorescence light collection efficiency of the holographic diffractive optical elements produced using this setup is demonstrated.


Assuntos
Holografia/métodos , Óptica e Fotônica , Refração Ocular , Anisotropia , Desenho de Equipamento , Corantes Fluorescentes/química , Lasers , Lentes , Luz , Microscopia de Fluorescência/métodos , Polímeros/química , Refratometria/métodos , Fatores de Tempo
3.
Assay Drug Dev Technol ; 6(3): 375-85, 2008 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-18532900

RESUMO

Software, named Cardio Analyser, was developed for digital movie analysis of beating frequencies, drug-induced chronotropic effects, and quantification of beating areas of contracting cardiomyocyte cultures. A major novelty of the software is the introduction of automated noise filtering and automated movie analysis of beating frequencies and areas of contracting cardiomyocyte cultures. The software was based on the observation that the intensity of light transmitted through a contractive tissue changes periodically in a way that correlates with the contractions. We provided proof of principle for the method by derivation of relevant data from movies of multicellular cardiomyocyte cultures derived from embryonic stem cells. Moreover, we compared the data to equivalent results obtained by extracellular electric field potential recordings. The comparison demonstrated higher sensitivity to chronotropic effects of the beta-adrenoceptor agonist isoprenaline, and hence implied that more embryonic stem cells underwent differentiation into beta-adrenoceptor-responding cardiomyocytes, in the experimental setup applied for movie analysis than in the setup used for extracellular electric field potential recordings. Our study indicates that the movie analysis method may have potential to be optimized for screening in early drug discovery, aiming to identify cardiac drug candidates or to alert for adverse effects on heart functionality or embryonic heart development.


Assuntos
Frequência Cardíaca , Contração Miocárdica , Miócitos Cardíacos/fisiologia , Animais , Linhagem Celular , Células-Tronco Embrionárias/citologia , Frequência Cardíaca/efeitos dos fármacos , Isoproterenol/farmacologia , Camundongos , Software
4.
J Biomed Opt ; 13(4): 041316, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-19021324

RESUMO

Fluorescence lifetime imaging (FLIM) is very demanding from a technical and computational perspective, and the output is usually a compromise between acquisition/processing time and data accuracy and precision. We present a new approach to acquisition, analysis, and reconstruction of microscopic FLIM images by employing a digital micromirror device (DMD) as a spatial illuminator. In the first step, the whole field fluorescence image is collected by a color charge-coupled device (CCD) camera. Further qualitative spectral analysis and sample segmentation are performed to spatially distinguish between spectrally different regions on the sample. Next, the fluorescence of the sample is excited segment by segment, and fluorescence lifetimes are acquired with a photon counting technique. FLIM image reconstruction is performed by either raster scanning the sample or by directly accessing specific regions of interest. The unique features of the DMD illuminator allow the rapid on-line measurement of global good initial parameters (GIP), which are supplied to the first iteration of the fitting algorithm. As a consequence, a decrease of the computation time required to obtain a satisfactory quality-of-fit is achieved without compromising the accuracy and precision of the lifetime measurements.


Assuntos
Algoritmos , Interpretação de Imagem Assistida por Computador/métodos , Lentes , Iluminação/instrumentação , Microscopia de Fluorescência/instrumentação , Processamento de Sinais Assistido por Computador/instrumentação , Espectrometria de Fluorescência/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Interpretação de Imagem Assistida por Computador/instrumentação
5.
Prog Biophys Mol Biol ; 129: 13-19, 2017 10.
Artigo em Inglês | MEDLINE | ID: mdl-27702656

RESUMO

Computational models in biology and biomedical science are often constructed to aid people's understanding of phenomena or to inform decisions with socioeconomic consequences. Model credibility is the willingness of people to trust a model's predictions and is often difficult to establish for computational biology models. A 3 × 3 matrix has been proposed to allow such models to be categorised with respect to their testability and epistemic foundation in order to guide the selection of an appropriate process of validation to supply evidence to establish credibility. Three approaches to validation are identified that can be deployed depending on whether a model is deemed untestable, testable or lies somewhere in between. In the latter two cases, the validation process involves the quantification of uncertainty which is a key output. The issues arising due to the complexity and inherent variability of biological systems are discussed and the creation of 'digital twins' proposed as a means to alleviate the issues and provide a more robust, transparent and traceable route to model credibility and acceptance.


Assuntos
Modelos Biológicos , Humanos , Reprodutibilidade dos Testes
7.
Toxicol In Vitro ; 27(2): 760-7, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23261643

RESUMO

When in vitro test systems are evaluated for assessment of the toxicity of chemical compounds, particular efforts are made to mimic the in vivo reality as close as possible. Cellular models with appropriate metabolic competence, i.e. with the potency to biotransform chemical compounds, are considered crucial since some metabolites have a different toxicity than their parent compounds. In this study a cell based in vitro test system is proposed to investigate the basal cytotoxicity of several reference chemicals. Both metabolic competent HepaRG cells and cells with no or low hepatic enzyme activity (undifferentiated HepaRG and proliferating HepG2) were used. The classic Neutral Red Uptake (NRU) assay proved to be robust and reliable to be applied as viability assay. The test was performed on a robotic platform, which enabled fully automated and simultaneous screening of the compounds. The outcome of these tests grouped the tested compounds in three categories following their detoxification effect (benzo(a)pyrene, valproic acid), their bio-activation effect (aflatoxin B1) and their specific effect on inhibition of cell proliferation (cycloheximide, sodium lauryl sulphate, atropine sulphate monohydrate, acetylsalicylic acid).


Assuntos
Vermelho Neutro/metabolismo , Testes de Toxicidade/métodos , Linhagem Celular , Sobrevivência Celular/efeitos dos fármacos , Sistema Enzimático do Citocromo P-450/genética , Sistema Enzimático do Citocromo P-450/metabolismo , Células Hep G2 , Humanos
8.
Toxicol Sci ; 136(1): 4-18, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23958734

RESUMO

Based on existing data and previous work, a series of studies is proposed as a basis toward a pragmatic early step in transforming toxicity testing. These studies were assembled into a data-driven framework that invokes successive tiers of testing with margin of exposure (MOE) as the primary metric. The first tier of the framework integrates data from high-throughput in vitro assays, in vitro-to-in vivo extrapolation (IVIVE) pharmacokinetic modeling, and exposure modeling. The in vitro assays are used to separate chemicals based on their relative selectivity in interacting with biological targets and identify the concentration at which these interactions occur. The IVIVE modeling converts in vitro concentrations into external dose for calculation of the point of departure (POD) and comparisons to human exposure estimates to yield a MOE. The second tier involves short-term in vivo studies, expanded pharmacokinetic evaluations, and refined human exposure estimates. The results from the second tier studies provide more accurate estimates of the POD and the MOE. The third tier contains the traditional animal studies currently used to assess chemical safety. In each tier, the POD for selective chemicals is based primarily on endpoints associated with a proposed mode of action, whereas the POD for nonselective chemicals is based on potential biological perturbation. Based on the MOE, a significant percentage of chemicals evaluated in the first 2 tiers could be eliminated from further testing. The framework provides a risk-based and animal-sparing approach to evaluate chemical safety, drawing broadly from previous experience but incorporating technological advances to increase efficiency.


Assuntos
Alternativas aos Testes com Animais/tendências , Mineração de Dados/tendências , Bases de Dados de Compostos Químicos/tendências , Bases de Dados de Produtos Farmacêuticos/tendências , Testes de Toxicidade/tendências , Animais , Relação Dose-Resposta a Droga , Previsões , Ensaios de Triagem em Larga Escala/tendências , Humanos , Modelos Animais , Modelos Biológicos , Testes de Mutagenicidade/tendências , Farmacocinética , Medição de Risco , Fatores de Risco
9.
Food Chem Toxicol ; 50(6): 2084-96, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22465836

RESUMO

Application of High Throughput Screening (HTS) to the regulatory safety assessment of chemicals is still in its infancy but shows great promise in terms of facilitating better understanding of toxicological modes-of-action, reducing the reliance on animal testing, and allowing more data-poor chemicals to be assessed at a reasonable cost. To promote the uptake and acceptance of HTS approaches, we describe in a stepwise manner how a well known cytotoxicity assay can be automated to increase throughput while maintaining reliability. Results generated with selected reference chemicals compared very favourably with data obtained from a previous international validation study concerning the prediction of acute systemic toxicity in rodents. The automated assay was then included in a formal ECVAM validation study to determine if the assay could be used for binary classification of chemicals with respect to their acute oral toxicity, using a threshold equivalent to a dose of 2000 mg/kg b.w. in a rodent bioassay (LD50). This involved the blind-testing of 56 reference chemicals on the HTS platform to produce concentration-response and IC50 data. Finally, the assay was adapted to a format more suited to higher throughput testing without compromising the quality of the data obtained.


Assuntos
Sobrevivência Celular/efeitos dos fármacos , Testes de Toxicidade Aguda/instrumentação , Células 3T3 , Alternativas aos Testes com Animais , Animais , Automação , Técnicas de Cultura de Células , Interpretação Estatística de Dados , Determinação de Ponto Final , Ensaios de Triagem em Larga Escala , Dose Letal Mediana , Camundongos , Software , Testes de Toxicidade Aguda/métodos
10.
Toxicol In Vitro ; 25(8): 2088-94, 2011 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-21959354

RESUMO

A quantitative, non-destructive cellular autofluorescence based in vitro imaging assay has been developed and applied to study the cytotoxicity of Sodium Lauryl Sulfate (SLS) and HgCl2 on Balb/c 3T3 cells. A phenomenological double logistic model was proposed to quantify and relate the observed kinetic changes of fluorescence to the toxic potency of chemical compounds. This work forms the basis for cellular autofluorescence measurements in in vitro toxicity screening assays.


Assuntos
Flavina-Adenina Dinucleotídeo/metabolismo , Cloreto de Mercúrio/toxicidade , NAD/metabolismo , Dodecilsulfato de Sódio/toxicidade , Tensoativos/toxicidade , Testes de Toxicidade/métodos , Animais , Células 3T3 BALB , Bioensaio , Sobrevivência Celular , Fluorescência , Cinética , Camundongos
11.
Toxicol Lett ; 206(3): 281-8, 2011 Oct 30.
Artigo em Inglês | MEDLINE | ID: mdl-21864658

RESUMO

Visualization of NADH by fluorescence microscopy makes it possible to distinguish mitochondria inside living cells, allowing structure analysis of these organelles in a non-invasive way. Mitochondrial morphology is determined by the occurrence of mitochondrial fission and fusion. During normal cell function mitochondria appear as elongated tubular structures. However, cellular malfunction induces mitochondria to fragment into punctiform, vesicular structures. This change in morphology is associated with the generation of reactive oxygen species (ROS) and early apoptosis. The aim of this study is to demonstrate that autofluorescence imaging of mitochondria in living eukaryotic cells provides structural and morphological information that can be used to assess mitochondrial health. We firstly established the illumination conditions that do not affect mitochondrial structure and calculated the maximum safe light dose to which the cells can be exposed. Subsequently, sequential recording of mitochondrial fluorescence was performed and changes in mitochondrial morphology were monitored in a continuous non-destructive way. This approach was then used to assess mitochondrial toxicity induced by potential toxicants exposed to mammalian cells. Both mouse and human cells were used to evaluate mitochondrial toxicity of different compounds with different toxicities. This technique constitutes a novel and promising approach to explore chemical induced toxicity because of its reliability to monitor mitochondrial morphology changes and corresponding toxicity in a non-invasive way.


Assuntos
Dactinomicina/toxicidade , Microscopia de Fluorescência/métodos , Mitocôndrias/efeitos dos fármacos , Animais , Células 3T3 BALB , Células Hep G2 , Humanos , Fusão de Membrana/efeitos dos fármacos , Camundongos , Mitocôndrias/patologia , Mitocôndrias/efeitos da radiação , NAD/análise , NAD/fisiologia , Dodecilsulfato de Sódio/toxicidade , Raios Ultravioleta
12.
J Biomed Opt ; 15(2): 028002, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20459292

RESUMO

The human hepatoma HepaRG cell line is an in vitro cell model that is becoming an important tool in drug metabolism, hepatotoxicity, genotoxicity, and enzyme induction studies. The cells are highly proliferative during their undifferentiated state but once committed, they differentiate into two distinctly different cell types, namely, hepatocyte-like and biliary epithelial-like cells. The presence of the latter in the cell culture is considered to be a drawback of the cell model. Since the proliferating undifferentiated HepaRG cells have a bipotent character, the only way to improve the content ratio of hepatic versus biliary cells of differentiated HepaRG cells is to eradicate biliary cells in situ, in a way that free surface space does not become available and thus no transdifferentiation can occur. Spatially selective photodynamic therapy has proven to be effective for that purpose. First, all the cells were administered aminolevulinic acid (delta-ALA) to stimulate the synthesis of protoporphyrin IX (PpIX), a naturally occurring photosensitizer. Then, the biliary cells were automatically identified and outlined by bright-field image processing. Last, UV light patterns were projected onto the epithelial cells alone by a spatial light modulation device connected to an optical microscope; therefore, only these cells were destroyed by photodynamic therapy.


Assuntos
Carcinoma Hepatocelular/patologia , Carcinoma Hepatocelular/fisiopatologia , Hepatócitos/citologia , Fotoquimioterapia/métodos , Fármacos Fotossensibilizantes/administração & dosagem , Diferenciação Celular/efeitos dos fármacos , Diferenciação Celular/efeitos da radiação , Linhagem Celular Tumoral , Proliferação de Células/efeitos dos fármacos , Proliferação de Células/efeitos da radiação , Hepatócitos/efeitos dos fármacos , Hepatócitos/efeitos da radiação , Humanos
13.
Opt Lett ; 33(22): 2614-6, 2008 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-19015685

RESUMO

An approach to enhancing the light collection from fluorescence emitters bound on the surface of a biochip is presented. It is based on the integration of diffractive optical elements on the underside of the chip that are essentially thick volume holograms written into a layer of photopolymer recording material. The high diffractive efficiency and angular selectivity of these types of diffractive elements make them very effective collectors of the spatially anisotropic light emitted by surface-bound fluorophores. The holographic lithography setup used to fabricate the diffractive elements is described. Results obtained using both a focused laser and light from a fluorescence spot to characterize the performance of the diffractive optical elements are presented.


Assuntos
Holografia/instrumentação , Aumento da Imagem/instrumentação , Microscopia de Fluorescência/instrumentação , Análise de Sequência com Séries de Oligonucleotídeos/instrumentação , Análise Serial de Proteínas/instrumentação , Refratometria/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Sensibilidade e Especificidade
14.
Nanotechnology ; 19(10): 105502, 2008 Mar 12.
Artigo em Inglês | MEDLINE | ID: mdl-21817700

RESUMO

An elegant method is proposed and demonstrated for tracking the location and movement of nanoparticles in an optical microscope using the optical phenomenon of caustics. A simple and reversible adjustment to the microscope generates caustics several orders of magnitude larger than the particles. The method offers a simple and relatively inexpensive method for visualizing such phenomena as the formation of self-assembled monolayers and the interaction of nanoparticles with chemically functionalized surfaces.

15.
Appl Opt ; 47(9): 1193-9, 2008 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-18709064

RESUMO

Time-domain fluorescence lifetime imaging (FLIM) and hyper-spectral imaging (HSI) are two advanced microscopy techniques widely used in biological studies. Typically both FLIM and HSI are performed with either a whole-field or raster-scanning approach, which often prove to be technically complex and expensive, requiring the user to accept a compromise among precision, speed, and spatial resolution. We propose the use of a digital micromirror device (DMD) as a spatial illuminator for time-domain FLIM and HSI with a laser diode excitation source. The rather unique features of the DMD allow both random and parallel access to regions of interest (ROIs) on the sample, in a very rapid and repeatable fashion. As a consequence both spectral and lifetime images can be acquired with a precision normally associated with single-point systems but with a high degree of flexibility in their spatial construction. In addition, the DMD system offers a very efficient way of implementing a global analysis approach for FLIM, where average fluorescence decay parameters are first acquired for a ROI and then used as initial estimates in determining their spatial distribution within the ROI. Experimental results obtained on phantoms employing fluorescent dyes clearly show how the DMD method supports both spectral and temporal separation for target identification in HSI and FLIM, respectively.


Assuntos
Óptica e Fotônica , Espectrometria de Fluorescência/instrumentação , Algoritmos , Diagnóstico por Imagem/instrumentação , Diagnóstico por Imagem/métodos , Desenho de Equipamento , Processamento de Imagem Assistida por Computador , Lasers , Análise dos Mínimos Quadrados , Imagens de Fantasmas , Reprodutibilidade dos Testes , Processamento de Sinais Assistido por Computador , Espectrometria de Fluorescência/métodos , Fatores de Tempo
16.
Opt Lett ; 33(4): 330-2, 2008 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-18278100

RESUMO

A laser Doppler vibrometer (LDV) is described in which holographic optical elements are used to provide the interferometer reference and object illumination beams. A complementary metal-oxide semiconductor camera, incorporating a digital signal processor, is used to carry out real-time signal processing of the interferometer output to allow multipoint LDV to be implemented.


Assuntos
Holografia/instrumentação , Interpretação de Imagem Assistida por Computador/instrumentação , Fluxometria por Laser-Doppler/instrumentação , Processamento de Sinais Assistido por Computador/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Holografia/métodos , Interpretação de Imagem Assistida por Computador/métodos , Fluxometria por Laser-Doppler/métodos , Reprodutibilidade dos Testes , Semicondutores , Sensibilidade e Especificidade
17.
Opt Lett ; 31(7): 912-4, 2006 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-16599209

RESUMO

With analog scanning, time-domain low-coherence interferometry lacks precise depth information, and optical carrier generation demands a linear scanning speed. Full-field heterodyne low-coherence interferometry that uses a logarithmic complementary metal-oxide semiconductor camera, acousto-optic modulation, and digital depth stepping is reported, with which random regions of interest, lateral and axial, can be accessed. Furthermore, nanometer profilometry is possible through heterodyne phase retrieval of the interference signal. The approach demonstrates inexpensive yet high-precision functional machine vision offering true digital random access in three dimensions.

18.
Appl Opt ; 41(25): 5238-44, 2002 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-12211548

RESUMO

We describe a genetic algorithm approach to solve an inverse problem in optics, which determines the characteristics of a fiber Bragg grating from its reflected spectrum. The validity of the proposed method is demonstrated by use of a Bragg sensor for the measurement of nonlinear strain acting on a uniaxial aluminum test specimen.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa