Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Sci Total Environ ; 737: 140212, 2020 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-32783842

RESUMO

We evaluated anthropogenic Pb deposition along a west-east transect from the Adirondack Mountains, New York, USA (ADIR) region, the Vermont-New Hampshire-Maine, USA (VT-NH-ME) region, and Nova Scotia, Canada (NS) region using 47 210Pb-dated lake sediment records. We used focus-corrected Pb inventories to evaluate cumulative deposition and breakpoint analysis to evaluate possible differences in timings among regions. Peak Pb concentrations decreased from west to east (ADIR region: 52-378 mg kg-1, VT-NH-ME region: 54-253 mg kg-1, NS: 38-140 mg kg-1). Cumulative deposition of anthropogenic Pb also decreased from west to east (ADIR region: 791-1344 mg m-2, VT-NH-ME region: 209-1206 mg m-2, NS: 52-421 mg m-2). The initiation of anthropogenic Pb deposition occurred progressively later along the same transect (ADIR region: 1869-1900, VT-NH-ME region: 1874-1905, NS region: 1901-1930). Previous lead isotope studies suggest that eastern Canadian Pb deposition over the past ~150 years has originated from a mix of both Canadian and U.S. sources. The results of this study indicate that anthropogenic Pb from sources west of the ADIR region were deposited in lesser amounts from west to east and/or Pb sources reflect less population density from west to east. The timing of the initiation of anthropogenic Pb deposition in the NS region suggests that Pb from gasoline may be an important source in this region.

2.
Environ Pollut ; 249: 45-53, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30878861

RESUMO

We assessed factory-calibrated field-portable X-ray fluorescence (pXRF) data quality for use with minimally-prepared aquatic sediments, including the precision of replicate pXRF measurements, accuracy of factory-calibrated pXRF values as compared to total digestion/ICP-OES concentrations, and comparability of calibrated pXRF values to extractable concentrations. Data quality levels for precision, accuracy, and comparability were not equivalent for element/analyzer combinations. All analyses of elements that were assessed for precision and accuracy on a single analyzer were both precise (<10% relative standard deviation) and accurate (r2 > 0.85) for K, Ca, Ti, Mn, Fe, and Zn. Calibrated pXRF values for Al, K, Ca, Ti, Mn, Fe, Cu, Zn, and Pb were within ∼10% relative difference of total digestion/ICP-OES concentrations. Calibrated pXRF values for Fe, Cu, Zn, As, and Pb were within ∼20% relative difference of extractable concentrations. Some elements had a higher level of data quality using specific analyzers, but in general, no pXRF analyzer had the highest level of data quality in all categories. Collectively, our data indicate that a wide range of factory-calibrated pXRF units are capable of providing high-quality total concentrations for the analysis of aquatic sediments.


Assuntos
Monitoramento Ambiental/métodos , Espectrometria por Raios X , Poluentes da Água/análise , Calibragem , Monitoramento Ambiental/instrumentação , Sedimentos Geológicos/química
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa