Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Phys Rev Lett ; 131(8): 082502, 2023 Aug 25.
Artigo em Inglês | MEDLINE | ID: mdl-37683153

RESUMO

We present an apparatus for detection of cyclotron radiation yielding a frequency-based ß^{±} kinetic energy determination in the 5 keV to 2.1 MeV range, characteristic of nuclear ß decays. The cyclotron frequency of the radiating ß particles in a magnetic field is used to determine the ß energy precisely. Our work establishes the foundation to apply the cyclotron radiation emission spectroscopy (CRES) technique, developed by the Project 8 Collaboration, far beyond the 18-keV tritium endpoint region. We report initial measurements of ß^{-}'s from ^{6}He and ß^{+}'s from ^{19}Ne decays to demonstrate the broadband response of our detection system and assess potential systematic uncertainties for ß spectroscopy over the full (MeV) energy range. To our knowledge, this is the first direct observation of cyclotron radiation from individual highly relativistic ß's in a waveguide. This work establishes the application of CRES to a variety of nuclei, opening its reach to searches for new physics beyond the TeV scale via precision ß-decay measurements.

2.
Phys Rev Lett ; 124(1): 012501, 2020 Jan 10.
Artigo em Inglês | MEDLINE | ID: mdl-31976711

RESUMO

We report a 0.08% measurement of the bound neutron scattering length of ^{4}He using neutron interferometry. The result is b=(3.0982±0.0021[stat]±0.0014[syst]) fm. The corresponding free atomic scattering length is a=(2.4746±0.0017[stat]±0.0011[syst]) fm. With this result the world average becomes b=(3.0993±0.0025) fm, a 2% downward shift and a reduction in uncertainty by more than a factor of six. Our result is in disagreement with a previous neutron interferometric measurement but is in good agreement with earlier measurements using neutron transmission.

3.
Phys Rev Lett ; 119(4): 042502, 2017 Jul 28.
Artigo em Inglês | MEDLINE | ID: mdl-29341742

RESUMO

We report the first result for the electron-antineutrino angular correlation (a coefficient) in free neutron ß decay from the aCORN experiment. aCORN uses a novel method in which the a coefficient is proportional to an asymmetry in proton time of flight for events where the ß electron and recoil proton are detected in delayed coincidence. Data are presented from a 15 month run at the NIST Center for Neutron Research. We obtained a=-0.1090±0.0030(stat)±0.0028(sys), the most precise measurement of the neutron a coefficient reported to date.

4.
Phys Rev Lett ; 116(24): 242501, 2016 Jun 17.
Artigo em Inglês | MEDLINE | ID: mdl-27367385

RESUMO

The standard model predicts that, in addition to a proton, an electron, and an antineutrino, a continuous spectrum of photons is emitted in the ß decay of the free neutron. We report on the RDK II experiment which measured the photon spectrum using two different detector arrays. An annular array of bismuth germanium oxide scintillators detected photons from 14 to 782 keV. The spectral shape was consistent with theory, and we determined a branching ratio of 0.00335±0.00005[stat]±0.00015[syst]. A second detector array of large area avalanche photodiodes directly detected photons from 0.4 to 14 keV. For this array, the spectral shape was consistent with theory, and the branching ratio was determined to be 0.00582±0.00023[stat]±0.00062[syst]. We report the first precision test of the shape of the photon energy spectrum from neutron radiative decay and a substantially improved determination of the branching ratio over a broad range of photon energies.

5.
Phys Rev Lett ; 111(22): 222501, 2013 Nov 27.
Artigo em Inglês | MEDLINE | ID: mdl-24329445

RESUMO

The most precise determination of the neutron lifetime using the beam method was completed in 2005 and reported a result of τ(n)=(886.3±1.2[stat]±3.2[syst]) s. The dominant uncertainties were attributed to the absolute determination of the fluence of the neutron beam (2.7 s). The fluence was measured with a neutron monitor that counted the neutron-induced charged particles from absorption in a thin, well-characterized 6Li deposit. The detection efficiency of the monitor was calculated from the areal density of the deposit, the detector solid angle, and the evaluated nuclear data file, ENDF/B-VI 6Li(n,t)4He thermal neutron cross section. In the current work, we measure the detection efficiency of the same monitor used in the neutron lifetime measurement with a second, totally absorbing neutron detector. This direct approach does not rely on the 6Li(n,t)4He cross section or any other nuclear data. The detection efficiency is consistent with the value used in 2005 but is measured with a precision of 0.057%, which represents a fivefold improvement in the uncertainty. We verify the temporal stability of the neutron monitor through ancillary measurements, allowing us to apply the measured neutron monitor efficiency to the lifetime result from the 2005 experiment. The updated lifetime is τ(n)=(887.7±1.2[stat]±1.9[syst]) s.

6.
Phys Rev Lett ; 107(10): 102301, 2011 Sep 02.
Artigo em Inglês | MEDLINE | ID: mdl-21981496

RESUMO

We report the results of an improved determination of the triple correlation DP·(p(e)×p(v)) that can be used to limit possible time-reversal invariance in the beta decay of polarized neutrons and constrain extensions to the standard model. Our result is D=[-0.96±1.89(stat)±1.01(sys)]×10(-4). The corresponding phase between gA and gV is ϕAV=180.013°±0.028° (68% confidence level). This result represents the most sensitive measurement of D in nuclear ß decay.

7.
Artigo em Inglês | MEDLINE | ID: mdl-31092963

RESUMO

Backscatter of electrons from a beta spectrometer, with incomplete energy deposition, can lead to undesirable effects in many types of experiments. We present and discuss the design and operation of a backscatter-suppressed beta spectrometer that was developed as part of a program to measure the electronantineutrino correlation coefficient in neutron beta decay (aCORN). An array of backscatter veto detectors surrounds a plastic scintillator beta energy detector. The spectrometer contains an axial magnetic field gradient, so electrons are efficiently admitted but have a low probability for escaping back through the entrance after backscattering. The design, construction, calibration, and performance of the spectrometer are discussed.

8.
Rev Sci Instrum ; 88(8): 083503, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28863637

RESUMO

We describe an apparatus used to measure the electron-antineutrino angular correlation coefficient in free neutron decay. The apparatus employs a novel measurement technique in which the angular correlation is converted into a proton time-of-flight asymmetry that is counted directly, avoiding the need for proton spectroscopy. Details of the method, apparatus, detectors, data acquisition, and data reduction scheme are presented, along with a discussion of the important systematic effects.

9.
J Res Natl Inst Stand Technol ; 110(3): 305-8, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-27308141

RESUMO

We present a new method for precision measurement of the capture flux polarization of a polychromatic (white), continuous cold neutron beam, polarized by a (3)He spin filter. This method allows an in situ measurement and does not require knowledge of the neutron beam wavelength distribution. We show that a polarimetry precision of 0.1 % is possible.

10.
J Res Natl Inst Stand Technol ; 110(4): 431-6, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-27308163

RESUMO

A new method of measuring the electron-antineutrino angular correlation coefficient, little "a", from neutron decay-to be performed at the National Institute of Standards and Technology-will require an electron spectrometer that strongly suppresses backscattered electrons. A prototype consisting of six trapezoidal veto detectors arranged around a plastic scintillator has been tested with an electron beam produced by a Van de Graaff accelerator. The results of this test and its implications for the little "a" measurement are discussed.

11.
J Res Natl Inst Stand Technol ; 110(4): 327-31, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-27308145

RESUMO

We measured the neutron decay lifetime by counting in-beam neutron decay recoil protons trapped in a quasi-Penning trap. The absolute neutron beam fluence was measured by capture in a thin (6)LiF foil detector with known efficiency. The combination of these measurements gives the neutron lifetime: τ n = (886.8 ± 1.2 ± 3.2) s, where the first (second) uncertainty is statistical (systematic) in nature. This is the most precise neutron lifetime determination to date using an in-beam method.

12.
J Res Natl Inst Stand Technol ; 110(4): 421-5, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-27308161

RESUMO

Beta decay of the neutron into a proton, electron, and electron antineutrino is occasionally accompanied by the emission of a photon. Despite decades of detailed experimental studies of neutron beta-decay, this rare branch of a fundamental weak decay has never been observed. An experiment to study the radiative beta-decay of the neutron is currently being developed for the NG-6 fundamental physics endstation at the National Institute of Standards and Technology (NIST) Center for Neutron Research (NCNR). The experiment will make use of the existing apparatus for the NIST proton-trap lifetime experiment, which can provide substantial background reduction by providing an electron-proton coincidence trigger. Tests and design of a detector for gamma-rays in the 10 keV to 200 keV range are under development. The need for a large solid-angle gamma-ray detector that can operate in a strong magnetic field and at low temperature has led us to consider scintillating crystals in conjunction with avalanche photodiodes. The motivation and experimental technique will be discussed.

13.
J Res Natl Inst Stand Technol ; 110(4): 401-5, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-27308157

RESUMO

Currently, the beta-neutrino asymmetry has the largest uncertainty (4 %) of the neutron decay angular correlations. Without requiring polarimetry this decay parameter can be used to measure λ (ga/gv ), test Cabibbo-Kobayashi-Maskawa (CKM) unitarity limit scalar and tensor currents, and search for Charged Vector Current (CVC) violation. We propose to measure the beta-neutrino asymmetry coeffcient, a, using time-of-flight for the recoil protons. We hope to achieve a systematic uncertainty of σa / a ≈ 1.0 %. After tests at Indiana University's Low Energy Neutron Source (LENS), the apparatus will be moved to the National Institute of Standards and Technology (NIST) where the measurement can achieve a statistical uncertainty of 1 % to 2 % in about 200 beam days.

14.
Phys Rev Lett ; 102(20): 200401, 2009 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-19519009

RESUMO

We report the first measurement of the low-energy neutron-(3)He incoherent scattering length using neutron interferometry: b_{i};{'} = (-2.512 +/- 0.012 stat +/- 0.014 syst) fm. This is in good agreement with a recent calculation using the AV18 + 3N potential. The neutron-(3)He scattering lengths are important for testing and developing nuclear potential models that include three-nucleon forces, effective field theories for few-body nuclear systems, and neutron scattering measurements of quantum excitations in liquid helium. This work demonstrates the first use of a polarized nuclear target in a neutron interferometer.

15.
Phys Rev Lett ; 91(15): 152302, 2003 Oct 10.
Artigo em Inglês | MEDLINE | ID: mdl-14611461

RESUMO

We report a new measurement of the neutron decay lifetime by the absolute counting of in-beam neutrons and their decay protons. Protons were confined in a quasi-Penning trap and counted with a silicon detector. The neutron beam fluence was measured by capture in a thin 6LiF foil detector with known absolute efficiency. The combination of these simultaneous measurements gives the neutron lifetime: tau(n)=(886.8+/-1.2[stat]+/-3.2[syst]) s. The systematic uncertainty is dominated by uncertainties in the mass of the 6LiF deposit and the 6Li(n,t) cross section. This is the most precise measurement of the neutron lifetime to date using an in-beam method.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa