RESUMO
The National Institute of Standards and Technology (NIST), in collaboration with the National Institutes of Health, Office of Dietary Supplements (NIH ODS), introduced the first Standard Reference Material® (SRM) for determining vitamin D metabolites in 2009 motivated by significant concerns about the comparability and accuracy of different assays to assess vitamin D status. After 14 years, a suite of five serum matrix SRMs and three calibration solution SRMs are available. Values were also assigned for vitamin D metabolites in five additional SRMs intended primarily to support measurements of other clinical diagnostic markers. Both the SRMs and the certification approach have evolved from significant exogenous serum content to primarily endogenous content and from value assignment by combining the results of multiple analytical methods to the use of measurements exclusively from reference measurement procedures (RMPs). The impact of the availability of these SRMs can be assessed by both the distribution information (sales) and by reports in the scientific literature describing their use for method validation, quality control, and research. In this review, we describe the development of these SRMs, the evolution in design and value assignment, the expansion of information reported, and SRM use in validating analytical methods and providing quality assurance within the vitamin D measurement community.
Assuntos
Vitamina D , Vitaminas , Controle de Qualidade , Padrões de Referência , Suplementos Nutricionais/análiseRESUMO
The US National Institute of Standards and Technology (NIST) developed a Standard Reference Material® (SRM®) 3949 Folate Vitamers in Frozen Human Serum to replace SRM 1955 Homocysteine and Folate in Human Serum. The presence of increased endogenous levels of folic acid and 5-methyltetrahydrofolate (5mTHF) in SRM 3949, enhanced folate stability via addition of ascorbic acid, and inclusion of values for additional minor folates are improvements over SRM 1955 that should better serve the clinical folate measurement community. The new SRM contains folates at three levels. To produce SRM 3949, pilot sera were collected from 15 individual donors, 5 of whom were given a 400-µg folic acid supplement 1 h prior to blood draw to increase serum levels of 5mTHF and folic acid for the high-level material. To stabilize the folates, 0.5% (mass concentration) ascorbic acid was added as soon as possible after preparation of serum. These pilot sera were screened for five folates plus the pyrazino-s-triazine derivative of 4-α-hydroxy-5-methyltetrahydrofolate (MeFox) at the US Centers for Disease Control and Prevention (CDC) by isotope dilution liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS). Based on these results, a blending protocol was specified to obtain the three desired folate concentrations for SRM 3949. ID-LC-MS/MS analysis at the CDC and NIST was utilized to assign values for folic acid and 5mTHF, as well as several minor folates.
Assuntos
Ácido Fólico , Espectrometria de Massas em Tandem , Humanos , Ácido Fólico/análise , Cromatografia Líquida/métodos , Espectrometria de Massas em Tandem/métodos , Padrões de Referência , Ácido AscórbicoRESUMO
Certified reference materials (CRMs) are routinely used by analytical chemists to validate new analytical methods and to demonstrate the quality of their quantitative measurements. Even though CRMs for trace element and trace organic analysis have been available and widely used for over 50 years, the majority of papers published in analytical chemistry journals do not mention the use of CRMs. What if analytical/bioanalytical chemistry journals required the use of CRMs to publish a paper? This feature article attempts to address this question by providing examples of recent papers that have made exceptional use of CRMs to validate new analytical methods and to describe novel, alternative uses of CRMs that provide new characterization of the CRM. The potential benefits of using a CRM even when it does not have certified values for the analytes of interest are presented.
Assuntos
Publicações Periódicas como Assunto , Oligoelementos , Química Analítica , Padrões de ReferênciaRESUMO
During the past 40 years, the National Institute of Standards and Technology (NIST) has developed over 180 natural matrix Standard Reference Materials® (SRMs) for the determination of trace organic constituents in environmental, clinical, food, and dietary supplement matrices. A list of the Top Ten SRMs intended for organic analysis was identified based on selection criteria including analytical challenge to assign certified values, challenges in material preparation, novel matrices, longevity, widespread use, and unique design concept or intended use. The environmental matrix SRMs include air particulate matter, marine sediment, mussel tissue, and human serum with the focus on contaminants such as polycyclic aromatic hydrocarbons (PAHs), polychlorinated biphenyls (PCBs), chlorinated pesticides, and polybrominated diphenyl ethers (PBDEs). Human serum and plasma SRMs for clinical diagnostic markers including vitamin D metabolites represent clinical analysis, whereas infant formula, multivitamin/multielement tablets, and Ginkgo biloba constitute the food and dietary supplement matrices on the list. Each of the SRMs on the Top Ten list is discussed relative to the selection criteria and significance of the material, and several overall lessons learned are summarized.
Assuntos
Poeira/análise , Sedimentos Geológicos/química , Ginkgo biloba/química , Padrões de Referência , Soro/química , Humanos , Oceanos e Mares , Estados Unidos , United States Government AgenciesRESUMO
The majority of circulating 25-hydroxyvitamin D (25(OH)D) is protein bound and perhaps less available than the free fraction of 25(OH)D; therefore, researchers have proposed that the measurement of free 25(OH)D in human serum may be a better indicator of vitamin D health status than total 25(OH)D. The availability of a new enzyme-linked immunosorbent assay (ELISA) for the determination of free 25(OH)D provides a method for direct measurement of the low levels of non-protein bound 25(OH)D. As an initial step towards harmonization of measurements of free 25(OH)D, the ELISA was used to measure free 25(OH)D in three existing Standard Reference Materials (SRMs): SRM 972a Vitamin D Metabolites in Frozen Human Serum, SRM 2973 Vitamin D Metabolites in Frozen Human Serum (High Level), and SRM 1949 Frozen Prenatal Human Serum. Target values for free 25(OH)D in the nine SRM serum pools, obtained by combining the results from two laboratories, ranged from 3.76 ± 0.36 to 10.0 ± 0.58 pg/mL. Of particular significance is the assignment of free 25(OH)D target values to SRM 1949, which consists of four serum pools from non-pregnant female donors of reproductive age and pregnant women in each of the three trimesters and which also has values assigned for vitamin D binding protein, which increases during pregnancy. The availability of target values for free 25(OH)D in these SRMs will allow researchers to validate new analytical methods and to compare their results with other researchers as an initial step towards harmonization of measurements among different studies and laboratories.
Assuntos
Proteína de Ligação a Vitamina D , Vitamina D , 25-Hidroxivitamina D 2 , Calcifediol , Ensaio de Imunoadsorção Enzimática , Feminino , Humanos , Gravidez , Vitamina D/análogos & derivados , Vitamina D/metabolismo , Proteína de Ligação a Vitamina D/metabolismo , VitaminasRESUMO
An interlaboratory comparison study was conducted by the Vitamin D Standardization Program (VDSP) to assess the performance of liquid chromatography - tandem mass spectrometry (LC-MS/MS) assays used for the determination of serum total 25-hydroxyvitamin D (25(OH)D), which is the sum of 25-hydroxyvitamin D2 (25(OH)D2) and 25-hydroxyvitamin D3 (25(OH)D3). A set of 50 single-donor samples was assigned target values for concentrations of 25(OH)D2, 25(OH)D3, 3-epi-25-hydroxyvitamin D3 (3-epi-25(OH)D3), and 24R,25-dihydroxyvitamin D3 (24R,25(OH)2D3) using isotope dilution liquid chromatography - tandem mass spectrometry (ID LC-MS/MS). VDSP Intercomparison Study 2 Part 1 includes results from 14 laboratories using 14 custom LC-MS/MS assays. Assay performance was evaluated using mean % bias compared to the assigned target values and using linear regression analysis of the test assay mean results and the target values. Only 53% of the LC-MS/MS assays met the VDSP criterion of mean % bias ≤ |±5%|. For the LC-MS/MS assays not meeting the ≤ |±5%| criterion, four assays had mean % bias of between 12 and 21%. Based on multivariable regression analysis using the concentrations of the four individual vitamin D metabolites in the 50 single-donor samples, the performance of several LC-MS/MS assays was found to be influenced by the presence of 3-epi-25(OH)D3. The results of this interlaboratory study represent the most comprehensive comparison of LC-MS/MS assay performance for serum total 25(OH)D and document the significant impact of the lack of separation of 3-epi-25(OH)D3 and 25(OH)D3 on assay performance, particularly with regard to mean % bias.
Assuntos
Espectrometria de Massas em Tandem , Vitamina D , 25-Hidroxivitamina D 2 , Cromatografia Líquida/métodos , Padrões de Referência , Espectrometria de Massas em Tandem/métodos , Vitamina D/análogos & derivadosRESUMO
An interlaboratory comparison study was conducted by the Vitamin D Standardization Program (VDSP) to assess the performance of ligand binding assays (Part 2) for the determination of serum total 25-hydroxyvitamin D [25(OH)D]. Fifty single-donor samples were assigned target values for concentrations of 25-hydroxyvitamin D2 [25(OH)D2], 25-hydroxyvitamin D3 [25(OH)D3], 3-epi-25-hydroxyvitamin D3 [3-epi-25(OH)D3], and 24R,25-dihydroxyvitamin D3 [24R,25(OH)2D3] using isotope dilution liquid chromatography-tandem mass spectrometry (ID LC-MS/MS). VDSP Intercomparison Study 2 Part 2 includes results from 17 laboratories using 32 ligand binding assays. Assay performance was evaluated using mean % bias compared to the assigned target values and using linear regression analysis of the test assay mean results and the target values. Only 50% of the ligand binding assays achieved the VDSP criterion of mean % bias ≤ |± 5%|. For the 13 unique ligand binding assays evaluated in this study, only 4 assays were consistently within ± 5% mean bias and 4 assays were consistently outside ± 5% mean bias regardless of the laboratory performing the assay. Based on multivariable regression analysis using the concentrations of individual vitamin D metabolites in the 50 single-donor samples, most assays underestimate 25(OH)D2 and several assays (Abbott, bioMérieux, DiaSorin, IDS-EIA, and IDS-iSYS) may have cross-reactivity from 24R,25(OH)2D3. The results of this interlaboratory study represent the most comprehensive comparison of 25(OH)D ligand binding assays published to date and is the only study to assess the impact of 24R,25(OH)2D3 content using results from a reference measurement procedure.
Assuntos
Espectrometria de Massas em Tandem , Vitamina D , 25-Hidroxivitamina D 2 , Cromatografia Líquida , Ligantes , Padrões de Referência , Vitamina D/análogos & derivadosRESUMO
The Vitamin D External Quality Assessment Scheme (DEQAS) distributes human serum samples four times per year to over 1000 participants worldwide for the determination of total serum 25-hydroxyvitamin D [25(OH)D)]. These samples are stored at -40 °C prior to distribution and the participants are instructed to store the samples frozen at -20 °C or lower after receipt; however, the samples are shipped to participants at ambient conditions (i.e., no temperature control). To address the question of whether shipment at ambient conditions is sufficient for reliable performance of various 25(OH)D assays, the equivalence of DEQAS human serum samples shipped under frozen and ambient conditions was assessed. As part of a Vitamin D Standardization Program (VDSP) commutability study, two sets of the same nine DEQAS samples were shipped to participants at ambient temperature and frozen on dry ice. Twenty-eight laboratories participated in this study and provided 34 sets of results for the measurement of 25(OH)D using 20 ligand binding assays and 14 liquid chromatography-tandem mass spectrometry (LC-MS/MS) methods. Equivalence of the assay response for the frozen versus ambient DEQAS samples for each assay was evaluated using multi-level modeling, paired t-tests including a false discovery rate (FDR) approach, and ordinary least squares linear regression analysis of frozen versus ambient results. Using the paired t-test and confirmed by FDR testing, differences in the results for the ambient and frozen samples were found to be statistically significant at p < 0.05 for four assays (DiaSorin, DIAsource, Siemens, and SNIBE prototype). For all 14 LC-MS/MS assays, the differences in the results for the ambient- and frozen-shipped samples were not found to be significant at p < 0.05 indicating that these analytes were stable during shipment at ambient conditions. Even though assay results have been shown to vary considerably among different 25(OH)D assays in other studies, the results of this study also indicate that sample handling/transport conditions may influence 25(OH)D assay response for several assays.
Assuntos
Congelamento , Vitamina D/análogos & derivados , Vitamina D/sangue , Cromatografia Líquida/métodos , Humanos , Espectrometria de Massas em Tandem/métodosRESUMO
OBJECTIVES: Matrix differences among serum samples from non-pregnant and pregnant patients could bias measurements. Standard Reference Material 1949, Frozen Human Prenatal Serum, was developed to provide a quality assurance material for the measurement of hormones and nutritional elements throughout pregnancy. METHODS: Serum from non-pregnant women and women in each trimester were bottled into four levels based on pregnancy status and trimester. Liquid chromatography tandem mass spectrometry (LC-MS/MS) methods were developed and applied to the measurement of thyroid hormones, vitamin D metabolites, and vitamin D-binding protein (VDBP). Copper, selenium, and zinc measurements were conducted by inductively coupled plasma dynamic reaction cell MS. Thyroid stimulating hormone (TSH), thyroglobulin (Tg), and thyroglobulin antibody concentrations were analyzed using immunoassays and LC-MS/MS (Tg only). RESULTS: Certified values for thyroxine and triiodothyronine, reference values for vitamin D metabolites, VDBP, selenium, copper, and zinc, and information values for reverse triiodothyronine, TSH, Tg, and Tg antibodies were assigned. Significant differences in serum concentrations were evident for all analytes across the four levels (p≤0.003). TSH measurements were significantly different (p<0.0001) among research-only immunoassays. Tg concentrations were elevated in research-only immunoassays vs. Federal Drug Administration-approved automated immunoassay and LC-MS/MS. Presence of Tg antibodies increased differences between automated immunoassay and LC-MS/MS. CONCLUSIONS: The analyte concentrations' changes consistent with the literature and the demonstration of matrix interferences in immunoassay Tg measurements indicate the functionality of this material by providing a relevant matrix-matched reference material for the different stages of pregnancy.
Assuntos
Selênio , Oligoelementos , Biomarcadores/sangue , Cromatografia Líquida , Cobre , Feminino , Humanos , Gravidez , Espectrometria de Massas em Tandem , Tireoglobulina/sangue , Glândula Tireoide , Tireotropina , Oligoelementos/sangue , Vitamina D/sangue , Vitaminas , ZincoRESUMO
An interlaboratory study was conducted through the Vitamin D Standardization Program (VDSP) to assess commutability of Standard Reference Materials® (SRMs) and proficiency testing/external quality assessment (PT/EQA) samples for determination of serum total 25-hydroxyvitamin D [25(OH)D] using ligand binding assays and liquid chromatography-tandem mass spectrometry (LC-MS/MS). A set of 50 single-donor serum samples were assigned target values for 25-hydroxyvitamin D2 [25(OH)D2] and 25-hydroxyvitamin D3 [25(OH)D3] using reference measurement procedures (RMPs). SRM and PT/EQA samples evaluated included SRM 972a (four levels), SRM 2973, six College of American Pathologists (CAP) Accuracy-Based Vitamin D (ABVD) samples, and nine Vitamin D External Quality Assessment Scheme (DEQAS) samples. Results were received from 28 different laboratories using 20 ligand binding assays and 14 LC-MS/MS methods. Using the test assay results for total serum 25(OH)D (i.e., the sum of 25(OH)D2 and 25(OH)D3) determined for the single-donor samples and the RMP target values, the linear regression and 95% prediction intervals (PIs) were calculated. Using a subset of 42 samples that had concentrations of 25(OH)D2 below 30 nmol/L, one or more of the SRM and PT/EQA samples with high concentrations of 25(OH)D2 were deemed non-commutable using 5 of 11 unique ligand binding assays. SRM 972a (level 4), which has high exogenous concentration of 3-epi-25(OH)D3, was deemed non-commutable for 50% of the LC-MS/MS assays.
Assuntos
Sociedades Médicas/normas , Vitamina D/análogos & derivados , Vitamina D/química , Humanos , Padrões de Referência , Manejo de Espécimes , Vitamina D/sangueRESUMO
For over 40 years, food-matrix certified reference materials (CRMs) have been available for determination of trace element content, and a wide variety of materials are available from most producers of CRMs. However, the availability of food-matrix CRMs for organic nutrients has been more limited. The European Commission (EC) Bureau Communautaire de Référence (BCR) and the National Institute of Standards and Technology (NIST) introduced food-matrix CRMs with values assigned for vitamins and other organic nutrients such as fatty acids and carotenoids in the 1990s. The number of organic nutrients for which values were assigned has increased significantly in the past decade, and the approach and analytical methods used for assignment of the certified values have also evolved. Recently, dietary supplement-matrix CRMs such as multivitamin tablets with values assigned for vitamins and carotenoids, and fish and plant oils with values assigned for fatty acids have appeared. The development, evolution, and improvement of food- and dietary supplement-matrix CRMs for determination of vitamins, carotenoids, and fatty acids are described, with emphasis on CRMs made available in the past 10 years. Recent food and dietary supplement CRMs for the determination of organic nutrients include infant formula, multivitamin tablets, milk and egg powders, breakfast cereal, meat homogenate, blueberries, soy flour, fish and plant oils, dry cat food, and protein drink powder. Many of these food- and supplement-matrix CRMs have values assigned for over 80 organic and inorganic nutrients, toxic elements, proximates, and contaminants. The review provides a critical assessment of the challenges and evolving improvements in the production and the analytical methods used for value assignment of these CRMs. The current status and future needs for additional food- and dietary supplement-matrix CRMs for organic nutrients are also discussed. Graphical abstract Food Composition Triangle with currently-available food-matrix certified reference materials (CRMs) for the determination of organic nutrients positioned according to fat, protein, and carbohydrate composition.
Assuntos
Suplementos Nutricionais/normas , Análise de Alimentos/métodos , Alimentos Orgânicos/normas , Colesterol/análise , Colesterol/normas , Suplementos Nutricionais/análise , Ácidos Graxos/análise , Ácidos Graxos/normas , Rotulagem de Alimentos , Alimentos Orgânicos/análise , Valor Nutritivo , Padrões de Referência , Vitaminas/análise , Vitaminas/normasRESUMO
Secondary organic aerosol (SOA) accounts for a significant fraction of particulate matter (PM) in the atmosphere. Source identification, including the SOA fraction, is critical for the effective management of air pollution. Molecular SOA markers (tracers) are key compounds allowing the source apportionment of SOA using different methodologies. Therefore, accurate SOA marker measurements in ambient air PM are important. This study determined the concentrations of 12 key SOA markers (biogenic and anthropogenic) in the urban dust standard reference material available from the National Institute of Standards and Technology (NIST) (SRM 1649b). Two extraction procedures, sonication and QuEChERS-like (quick easy cheap effective rugged and safe), have been compared. Three research laboratories/institutes using two analytical techniques (gas chromatography/mass spectrometry (GC/MS) and ultra-high-pressure liquid chromatography/tandem mass spectrometry (HPLC/MS-MS)) carried out the analyses. The results obtained were all in good agreement, except for 2-methylerythritol. The analysis of this compound still seems to be challenging by both GC/MS (large injection repeatability) and HPLC/MS-MS (separation issues of both 2-methyltetrols: 2-methylthreitol and 2-methylerythritol). Possible inhomogeneity in the SRM for this compound could also explain the large discrepancies observed. Sonication and QuEChERS-like procedures gave comparable results for the extraction of the SOA markers showing that QuEChERS-like extraction is suitable for the analysis of SOA markers in ambient air PM. As this study provides, for the first time, indicative values in a reference material for typical SOA markers, the analysis of SRM 1649b (urban dust) could be used for quality control/assurance purposes. Graphical abstract.
RESUMO
The Dietary Supplement Label Database (DSLD) is sponsored by the Office of Dietary Supplements (ODS) and the National Library of Medicine (NLM). It provides a searchable, free database of the contents of â¼65,000 supplement labels. A companion database of analytically verified product labels [the Dietary Supplement Ingredient Database (DSID)] was created by ODS, NLM, and the USDA. There are considerable challenges to populating both databases, but the DSID faces unique analytic chemistry challenges. This article describes the challenges to creating analytically verified marketplace surveys of dietary supplement (DS) product content claims for inclusion in public databases. Nutritionists and public health scientists require information on actual exposures to DS constituents because labeled content may not match labeled product content. Analytic verification of composition of DSs provides a link to actual exposure. A public database of analytically derived DS content was developed to provide more accurate estimates of dietary intake in population-based epidemiologic studies. The DSID has conducted surveys of several types of vitamin- and mineral-containing DSs. Results showing label content claims as analytically derived values are available in the current DSID. A recent pilot project explored the feasibility of adding botanical DS products to the DSID. Candidates for future botanical DSID studies will be based on sales volume, potential public health impacts, and the availability of validated analytic methods and reference materials. Databases like DSID and the DSLD are essential for researchers and clinicians to evaluate dietary ingredient intakes in population-based epidemiologic studies. Together, these databases provide a picture of the DS marketplace. The DSID provides an analytic survey of marketed DSs. However, selection of future botanical supplements for DSID evaluation involves analytic challenges. Even when appropriate resources are available, method selection and data evaluation are resource- and time-consuming.
Assuntos
Bases de Dados Factuais , Suplementos Nutricionais/análise , Suplementos Nutricionais/efeitos adversos , Suplementos Nutricionais/normas , Rotulagem de Alimentos , Humanos , Laboratórios , Minerais/análise , Minerais/normas , National Institutes of Health (U.S.) , National Library of Medicine (U.S.) , Saúde Pública , Padrões de Referência , Chá/química , Chá/normas , Estados Unidos , United States Department of Agriculture , Vitaminas/análise , Vitaminas/normasRESUMO
Retention indices (I) for 45 polycyclic aromatic hydrocarbons (PAHs) and 63 methyl-substituted PAHs were determined by gas chromatography - mass spectrometry (GC-MS) using two different stationary phases: a Rxi-PAH phase (a "higher phenyl-content stationary phase") and a 50% (mole fraction) liquid crystalline dimethylpolysiloxane phase. Retention data were obtained for parent PAHs from molecular mass (MM) 128 g/mol (naphthalene) to 328 g/mol (benzo[c]picene) and for 12 sets of methyl-PAHs (methylfluorenes, methylanthracenes, methylphenanthrenes, methylfluoranthenes, methylpyrenes, methylbenz[a]anthracenes, methylbenzo[c]phenanthrenes, methylchrysenes, methyltriphenylenes, methylbenzo[a]pyrenes, methylperylenes, and methylpicenes). Molecular shape descriptors such as length-to-breath ratio (L/B) and thickness (T) were determined for all the PAHs studied. Correlation between I and L/B ratio was evaluated for both stationary phases with a better correlation observed for the 50% liquid crystalline phase (correlation coefficients ranging from 0.22 to 1.00). Graphical Abstract GC separation of six methylchrysene isomers (m/z 242) on two different stationary phases: 50 % phenyl-like methylpolysiloxane phase and 50 % liquid crystalline phase. Retention indices (I) are plotted as a function of L/B for both phases. The data marker numbers identify each isomer based on methyl-substitution position.
RESUMO
The relationship of reversed-phase liquid chromatography (RPLC) retention on a polymeric C18 stationary phase and the shape of polycyclic aromatic hydrocarbons (PAHs) was investigated for three-ring to seven-ring cata-condensed isomers. We report the first RPLC separation for six-ring and seven-ring cata-condensed PAH isomers. Correlations of LC retention and shape parameters (length-to-breath ratio, L/B and thickness, T) were investigated for 2 three-ring isomers (molecular mass 178 Da), 5 four-ring isomers (molecular mass 228 Da), 11 five-ring isomers (molecular mass 278 Da), 17 six-ring isomers (molecular mass 328 Da), and 20 seven-ring isomers (molecular mass 378 Da). Significant linear correlations were found for all isomer groups (r = 0.71 to 0.94). Nonplanarity of the PAH isomers was found to influence retention (i.e., nonplanar isomers eluting earlier than expected based on L/B) and linear correlations of retention vs. T for isomer groups containing nonplanar isomers were significant (r = 0.71 to 0.86). Graphical abstract.
RESUMO
The research described here provides the most comprehensive qualitative characterization of three combustion-related standard reference materials (SRMs) for polycyclic aromatic sulfur heterocycles (PASHs) and some alkyl-substituted (alkyl-) derivatives to date: SRM 1597a (coal tar), SRM 1991 (coal tar/petroleum extract), and SRM 1975 (diesel particulate extract). An analytical approach based on gas chromatography/mass spectrometry (GC/MS) is presented for the determination of three-, four-, and five-ring PASH isomers and three- and four-ring alkyl-PASHs in the three SRM samples. The benefit of using a normal-phase liquid chromatography (NPLC) fractionation procedure prior to GC/MS analysis was demonstrated for multiple isomeric PASH groups. Using a semi-preparative aminopropyl (NH2) LC column, the three combustion-related samples were fractionated based on the number of aromatic carbon atoms. The NPLC-GC/MS method presented here allowed for the following identification breakdown: SRM 1597a - 35 PASHs and 59 alkyl-PASHs; SRM 1991-31 PASHs and 58 alkyl-PASHs; and SRM 1975-13 PASHs and 25 alkyl-PASHs. These identifications were based on NPLC retention data, the GC retention times of reference standards, and the predominant molecular ion peak in the mass spectrum. Prior to this study, only 11, 1, and 0 PASHs/alkyl-PASHs had been identified in SRM 1597a, SRM 1991, and SRM 1975, respectively. Graphical abstract NPLC-GC/MS analysis for the three- and four-ring parent PASH isomers in SRM 1597a.
RESUMO
Retention indices for 67 polycyclic aromatic sulfur heterocycles (PASHs) and 80 alkyl-substituted PASHs were determined using normal-phase liquid chromatography (NPLC) on an aminopropyl (NH2) stationary phase. The retention behavior of PASH on the NH2 phase is correlated with the number of aromatic carbon atoms and two structural characteristics have a significant influence on their retention: non-planarity (thickness, T) and the position of the sulfur atom in the bay-region of the structure. Correlations between solute retention on the NH2 phase and T of PASHs were investigated for three cata-condensed (cata-) PASH isomer groups: (a) 13 four-ring molecular mass (MM) 234 Da cata-PASHs, (b) 20 five-ring MM 284 Da cata-PASHs, and (c) 12 six-ring MM 334 Da cata-PASHs. Correlation coefficients ranged from r = -0.49 (MM 234 Da) to r = -0.65 (MM 334 Da), which were significantly lower than structurally similar PAH isomer groups (r = -0.70 to r = -0.99). The NPLC retention behavior of the PASHs are compared to similar results for PAHs.
RESUMO
A new tobacco filler Standard Reference Material (SRM) has been issued by the National Institute of Standards and Technology (NIST) in September 2016 with certified and reference mass fraction values for nicotine, N-nitrosonornicotine, 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanone, and volatiles. The constituents have been determined by multiple analytical methods with measurements at NIST and at the Centers for Disease Control and Prevention, and with confirmatory measurements by commercial laboratories. This effort highlights the development of the first SRM for reduced nicotine and reduced tobacco-specific nitrosamines with certified values for composition.
Assuntos
Cromatografia Gasosa-Espectrometria de Massas/métodos , Espectrometria de Massas em Tandem/métodos , Produtos do Tabaco/análise , Cromatografia Líquida de Alta Pressão/métodos , Cromatografia Líquida de Alta Pressão/normas , Congelamento , Cromatografia Gasosa-Espectrometria de Massas/normas , Nicotina/análise , Nicotina/normas , Nitrosaminas/análise , Nitrosaminas/normas , Transição de Fase , Padrões de Referência , Espectrometria de Massas em Tandem/normas , Produtos do Tabaco/normas , Compostos Orgânicos Voláteis/análise , Compostos Orgânicos Voláteis/normasRESUMO
The National Institute of Standards and Technology (NIST) has developed Standard Reference Material (SRM) 972a Vitamin D Metabolites in Frozen Human Serum as a replacement for SRM 972, which is no longer available. SRM 972a was developed in collaboration with the National Institutes of Health's Office of Dietary Supplements. In contrast to the previous reference material, three of the four levels of SRM 972a are composed of unmodified human serum. This SRM has certified and reference values for the following 25-hydroxyvitamin D [25(OH)D] species: 25(OH)D2, 25(OH)D3, and 3-epi-25(OH)D3. The value assignment and certification process included three isotope-dilution mass spectrometry approaches, with measurements performed at NIST and at the Centers for Disease Control and Prevention (CDC). The value assignment methods employed have been modified from those utilized for the previous SRM, and all three approaches now incorporate chromatographic resolution of the stereoisomers, 25(OH)D3 and 3-epi-25(OH)D3.