Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Poult Sci ; 95(8): 1848-57, 2016 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-27038422

RESUMO

Three experiments were conducted to evaluate the effect of ß-mannanase BM: supplementation on the performance, metabolizable energy, amino acid digestibility, and immune function of broilers. A total of 1,600 broilers were randomly distributed in a 4 × 2 factorial arrangement (4 nutritional levels × 0 or 500 g/ton BM), with 10 replicates and 20 broilers per pen. The same design was used in the energy and digestibility experiments with 8 and 6 replicates, respectively, and 6 broilers per pen. The nutritional levels : NL : were formulated to meet the nutritional requirements of broilers : NL1 : ; reductions of 100 kcal metabolizable energy : NL2 : ; 3% of the total amino acids (NL3); and 100 kcal metabolizable energy and 3% total amino acids (NL4) from NL1. The serum immunoglobulin (Ig) concentration was determined in two broilers per pen, and these broilers were slaughtered to determine the relative weight of spleen, thymus, and bursa of Fabricius. Throughout the experiment, the lower nutritional levels reduced (P < 0.05) body weight gain : BWG : and increased (P < 0.05) feed conversion : FCR : for the NL4 treatment. The BM increased (P < 0.05) the BWG values and improved (P < 0.05) the FCR of the broilers. The apparent metabolizable energy corrected for nitrogen balance (AMEn) values were reduced (P < 0.05) for NL2 and NL3. The BM increased (P < 0.05) the AMEn values and reduced (P < 0.05) the excreted nitrogen. NL3 and NL4 reduced (P < 0.05) the true ileal digestibility coefficients (TIDc) of the amino acids cystine and glycine, and BM increased (P < 0.05) the TIDc for all amino acids. The addition of BM reduced (P < 0.05) the relative weights of the spleen and bursa. NL2 increased (P < 0.05) the Ig values, whereas BM reduced (P < 0.05) the serum IgA, IgG, and IgM values of the broilers. This study indicates that using suboptimal nutrient levels leads to losses in production parameters, whereas BM-supplemented diets were effective in improving performance, energy values, and TIDc levels of amino acids and immune response of broilers.


Assuntos
Aminoácidos/metabolismo , Galinhas/crescimento & desenvolvimento , beta-Manosidase/farmacologia , Ração Animal , Fenômenos Fisiológicos da Nutrição Animal/efeitos dos fármacos , Fenômenos Fisiológicos da Nutrição Animal/fisiologia , Animais , Galinhas/imunologia , Galinhas/metabolismo , Galinhas/fisiologia , Suplementos Nutricionais , Digestão/fisiologia , Metabolismo Energético/fisiologia , Imunidade/efeitos dos fármacos , Imunidade/fisiologia , Masculino
2.
Ann Allergy Asthma Immunol ; 84(6): 599-604, 2000 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-10875488

RESUMO

OBJECTIVE: The object is to design, develop, and test a personal aerosol sampling device consisting of impaction samplers worn just inside the nostrils, driven by the wearer's respiration. The device provides a novel and unique measure of individual exposure to aeroallergens. It was conceived as an integral part of an allergen diagnostic system, in which collected aerosols are immunostained with monoclonal antibodies or the patient's IgE and associated particles positively identified using techniques of image analysis. METHODS: Each sampler comprises a slot impactor with a detachable impaction plate covered with either a specially developed medical adhesive or a protein-binding membrane. Sampler performance has been validated by rig tests of aerodynamic resistance and collection efficiency of different sized particles at various flow rates. There have also been field trials with human subjects which show that the sampler can be comfortably worn for periods of up to 4 hours. This is sufficient to gather a representative sample of inhaled allergens in most environments. RESULTS: The sampler collects an increasing proportion of particles in the inhalable range at and above 5 microm. This includes most bioaerosols of interest to allergists. Sampler prototypes have been built by CNC mill and stereolithography. Batches of samplers have been molded in biocompatible materials for field and clinical trials. CONCLUSIONS: The device successfully collects aeroallergens from a patient's own respiration. While developed specifically as a vehicle for the allergen diagnostic system, it can be adapted for studies of other aspects of air quality or for prophylactic use.


Assuntos
Poluentes Atmosféricos/análise , Poluição do Ar/análise , Alérgenos/administração & dosagem , Exposição Ambiental , Mucosa Nasal/química , Mucosa Nasal/imunologia , Administração por Inalação , Aerossóis , Resistência das Vias Respiratórias , Equipamentos e Provisões/normas , Feminino , Humanos , Nariz/fisiologia
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa