Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros

Base de dados
País como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Xray Sci Technol ; 2024 Jun 11.
Artigo em Inglês | MEDLINE | ID: mdl-38875073

RESUMO

BACKGROUND: The polychromatic X-rays generated by a linear accelerator (Linac) often result in noticeable hardening artifacts in images, posing a significant challenge to accurate defect identification. To address this issue, a simple yet effective approach is to introduce filters at the radiation source outlet. However, current methods are often empirical, lacking scientifically sound metrics. OBJECTIVE: This study introduces an innovative filter design method that optimizes filter performance by balancing the impact of ray intensity and energy on image quality. MATERIALS AND METHODS: Firstly, different spectra under various materials and thicknesses of filters were obtained using GEometry ANd Tracking (Geant4) simulation. Subsequently, these spectra and their corresponding incident photon counts were used as input sources to generate different reconstructed images. By comprehensively comparing the intensity differences and noise in images of defective and non-defective regions, along with considering hardening indicators, the optimal filter was determined. RESULTS: The optimized filter was applied to a Linac-based X-ray computed tomography (CT) detection system designed for identifying defects in graphite materials within high-temperature gas-cooled reactor (HTR), with defect dimensions of 2 mm. After adding the filter, the hardening effect reduced by 22%, and the Defect Contrast Index (DCI) reached 3.226. CONCLUSION: The filter designed based on the parameters of Average Difference (AD) and Defect Contrast Index (DCI) can effectively improve the quality of defect images.

2.
J Appl Clin Med Phys ; 24(10): e14062, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37312288

RESUMO

OBJECTIVE: The stopping power ratio (SPR) prediction error will contribute to the range uncertainty of proton therapy. Spectral CT is promising in reducing the uncertainty in SPR estimation. The purpose of this research is to determine the optimal energy pairs of SPR prediction for each tissue and to evaluate the dose distribution and range difference between the spectral CT with the optimal energy pairs method and the single energy CT (SECT) method. METHODS: A new method was proposed based on image segmentation to calculate the proton dose with spectral CT images for the head and body phantom. CT number of each organ region were converted to SPR with the optimal energy pairs of each organ. The CT images were segmented into different organ parts with thresholding method. Virtual monoenergetic (VM) images from 70 keV to 140 keV were investigated to determine the optimal energy pairs for each organ based on Gammex 1467 phantom. The beam data of Shanghai Advanced Proton Therapy facility (SAPT) was employed in matRad (an open-source software for radiation treatment planning) for the dose calculation. RESULTS: The optimal energy pairs were obtained for each tissue. The dose distribution of two tumor sites (brain and lung) were calculated with the aforementioned optimal energy pairs. The maximum dose deviation between spectral CT and SECT at the target region was 2.57% and 0.84% for the lung tumor and brain tumor respectively. The range difference between spectral and SECT was significant with 1.8411 mm for the lung tumor. γ passing rate was 85.95% and 95.49% for the lung tumor and brain tumor with the criterion 2%/2 mm. CONCLUSIONS: This work presents a way to determine the optimal energy pairs for each organ and to calculate the dose distribution based on the more accurate SPR prediction.


Assuntos
Neoplasias Encefálicas , Neoplasias Pulmonares , Terapia com Prótons , Humanos , Prótons , Incerteza , Tomografia Computadorizada por Raios X/métodos , China , Terapia com Prótons/métodos , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/radioterapia , Imagens de Fantasmas , Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/radioterapia
3.
Opt Express ; 28(22): 33077-33083, 2020 Oct 26.
Artigo em Inglês | MEDLINE | ID: mdl-33114977

RESUMO

Photonic crystals coated on the surface of scintillators can be used to improve the light extraction efficiency by partially eliminating the total internal reflection. However, the traditional self-assembly technique is not applicable to the hygroscopic scintillators. In the present investigation, we have proposed an efficient method to prepare the photonic crystals on the surface of CsI(Na) hygroscopic scintillators by a combination of the self-assemble of polystyrene (PS) microspheres and the subsequent dry-transfer procedure. For obtaining optimal parameters of photonic crystals, the light output of the CsI(Na) sample is enhanced by 43.2% compared to the reference sample without photonic crystals under the excitation of alpha particles from 241Am source. The energy resolution is improved from 11.2% to 7.8%. This technique based on the dry-transfer procedure has a promising prospect in the preparation of photonic crystals for hygroscopic scintillators.

4.
Biomed Eng Online ; 16(1): 2, 2017 Jan 05.
Artigo em Inglês | MEDLINE | ID: mdl-28086901

RESUMO

BACKGROUND: For cone-beam computed tomography (CBCT), which has been playing an important role in clinical applications, iterative reconstruction algorithms are able to provide advantageous image qualities over the classical FDK. However, the computational speed of iterative reconstruction is a notable issue for CBCT, of which the forward projection calculation is one of the most time-consuming components. METHOD AND RESULTS: In this study, the cone-beam forward projection problem using the voxel-driven model is analysed, and a GPU-based acceleration method for CBCT forward projection is proposed with the method rationale and implementation workflow detailed as well. For method validation and evaluation, computational simulations are performed, and the calculation times of different methods are collected. Compared with the benchmark CPU processing time, the proposed method performs effectively in handling the inter-thread interference problem, and an acceleration ratio as high as more than 100 is achieved compared to a single-threaded CPU implementation. CONCLUSION: The voxel-driven forward projection calculation for CBCT is highly paralleled by the proposed method, and we believe it will serve as a critical module to develop iterative reconstruction and correction methods for CBCT imaging.


Assuntos
Gráficos por Computador , Tomografia Computadorizada de Feixe Cônico , Processamento de Imagem Assistida por Computador/métodos , Fatores de Tempo
5.
Gels ; 9(3)2023 Mar 10.
Artigo em Inglês | MEDLINE | ID: mdl-36975661

RESUMO

With the complexity and high demands on quality assurance (QA) of photon beam radiation therapy, end-to-end (E2E) QA is necessary to validate the entire treatment workflow from pre-treatment imaging to beam delivery. A polymer gel dosimeter is a promising tool for three-dimensional (3D) dose distribution measurement. The purpose of this study is to design a fast "one delivery" polymethyl methacrylate (PMMA) phantom with a polymer gel dosimeter for the E2E QA test of the photon beam. The one delivery phantom is composed of ten calibration cuvettes for the calibration curve measurement, two 10 cm gel dosimeter inserts for the dose distribution measurement, and three 5.5 cm gel dosimeters for the square field measurement. The one delivery phantom holder is comparable in size and shape to that of a human thorax and abdomen. In addition, an anthropomorphic head phantom was employed to measure the patient-specific dose distribution of a VMAT plan. The E2E dosimetry was verified by undertaking the whole RT procedure (immobilization, CT simulation, treatment planning, phantom set-up, imaged-guided registration, and beam delivery). The calibration curve, field size, and patient-specific dose were measured with a polymer gel dosimeter. The positioning error can be mitigated with the one-delivery PMMA phantom holder. The delivered dose measured with a polymer gel dosimeter was compared with the planned dose. The gamma passing rate is 86.64% with the MAGAT-f gel dosimeter. The results ascertain the feasibility of the one delivery phantom with a polymer gel dosimeter for a photon beam in E2E QA. The QA time can be reduced with the designed one delivery phantom.

6.
J Exp Clin Cancer Res ; 41(1): 316, 2022 Oct 28.
Artigo em Inglês | MEDLINE | ID: mdl-36307871

RESUMO

Bone metastasis occurs when tumour cells dissociate from primary tumours, enter the circulation (circulating tumour cells, CTCs), and colonize sites in bone (disseminated tumour cells, DTCs). The bone marrow seems to be a particularly dormancy-inducing environment for DTCs, yet the mechanisms of dormancy initiation, reactivation, and interaction within the bone marrow have to be elucidated. Intriguingly, some evidence has suggested that dormancy is a reversible state that is switched 'on' or 'off' depending on the presence of various bone marrow resident cells, particularly osteoclasts and osteoblasts. It has become clear that these two cells contribute to regulating dormant tumour cells in bone both directly (interaction) and indirectly (secreted factors). The involved mechanisms include TGFß signalling, the Wnt signalling axis, the Notch2 pathway, etc. There is no detailed review that specifically focuses on ascertaining the dynamic interactions between tumour cell dormancy and bone remodelling. In addition, we highlighted the roles of inflammatory cytokines during this 'cell-to-cell' communication. We also discussed the potential clinical relevance of remodelling the bone marrow niche in controlling dormant tumour cells. Understanding the unique role of osteoclasts and osteoblasts in regulating tumour dormancy in bone marrow will provide new insight into preventing and treating tumour bone metastasis.


Assuntos
Neoplasias Ósseas , Células Neoplásicas Circulantes , Humanos , Osteoclastos/metabolismo , Osteoclastos/patologia , Osteoblastos/metabolismo , Osteoblastos/patologia , Neoplasias Ósseas/patologia , Células Neoplásicas Circulantes/metabolismo , Medula Óssea/metabolismo , Metástase Neoplásica/patologia
7.
Front Pharmacol ; 13: 842203, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35185591

RESUMO

Gastrointestinal cancers refer to a group of deadly malignancies of the gastrointestinal tract and organs of the digestive system. Over the past decades, considerable amounts of medicinal plants have exhibited potent anticancer effects on different types of gastrointestinal cancers. OMICS, systems biology approaches covering genomics, transcriptomics, proteomics and metabolomics, are broadly applied to comprehensively reflect the molecular profiles in mechanistic studies of medicinal plants. Single- and multi-OMICS approaches facilitate the unravelling of signalling interaction networks and key molecular targets of medicinal plants with anti-gastrointestinal cancer potential. Hence, this review summarizes the applications of various OMICS and advanced bioinformatics approaches in examining therapeutic targets, signalling pathways, and the tumour microenvironment in response to anticancer medicinal plants. Advances and prospects in this field are also discussed.

8.
Phys Med Biol ; 61(24): 8425-8439, 2016 12 21.
Artigo em Inglês | MEDLINE | ID: mdl-27845916

RESUMO

Optical computed tomography (optical-CT) is a high-resolution, fast, and easily accessible readout modality for gel dosimeters. This paper evaluates a hybrid iterative image reconstruction algorithm for optical-CT gel dosimeter imaging, namely, the simultaneous algebraic reconstruction technique (SART) integrated with ordered subsets (OS) iteration and total variation (TV) minimization regularization. The mathematical theory and implementation workflow of the algorithm are detailed. Experiments on two different optical-CT scanners were performed for cross-platform validation. For algorithm evaluation, the iterative convergence is first shown, and peak-to-noise-ratio (PNR) and contrast-to-noise ratio (CNR) results are given with the cone-beam filtered backprojection (FDK) algorithm and the FDK results followed by median filtering (mFDK) as reference. The effect on spatial gradients and reconstruction artefacts is also investigated. The PNR curve illustrates that the results of SART + OS + TV finally converges to that of FDK but with less noise, which implies that the dose-OD calibration method for FDK is also applicable to the proposed algorithm. The CNR in selected regions-of-interest (ROIs) of SART + OS + TV results is almost double that of FDK and 50% higher than that of mFDK. The artefacts in SART + OS + TV results are still visible, but have been much suppressed with little spatial gradient loss. Based on the assessment, we can conclude that this hybrid SART + OS + TV algorithm outperforms both FDK and mFDK in denoising, preserving spatial dose gradients and reducing artefacts, and its effectiveness and efficiency are platform independent.


Assuntos
Algoritmos , Processamento de Imagem Assistida por Computador/métodos , Imagens de Fantasmas , Tomografia Óptica/métodos , Tomografia Computadorizada por Raios X/métodos , Artefatos , Humanos , Dosímetros de Radiação
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa