Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31
Filtrar
1.
Small ; 19(14): e2206738, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36592430

RESUMO

The use of metal foil catalysts in the chemical vapor deposition of graphene films makes graphene transfer an ineluctable part of graphene device fabrication, which greatly limits industrialization. Here, an oxide phase-change material (V2 O5 ) is found to have the same catalytic effect on graphene growth as conventional metals. A uniform large-area graphene film can be obtained on a 10 nm V2 O5 film. Density functional theory is used to quantitatively analyze the catalytic effect of V2 O5 . Due to the high resistance property of V2 O5 at room temperature, the obtained graphene can be directly used in devices with V2 O5 as an intercalation layer. A wafer-scale graphene-V2 O5 -Si (GVS) Schottky photodetector array is successfully fabricated. When illuminated by a 792 nm laser, the responsivity of the photodetector can reach 266 mA W-1 at 0 V bias and 420 mA W-1 at 2 V. The transfer-free device fabrication process enables high feasibility for industrialization.

2.
Opt Express ; 31(8): 12138-12149, 2023 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-37157379

RESUMO

The nanoplasmonic sensor of the nanograting array has a remarkable ability in label-free and rapid biological detection. The integration of the nanograting array with the standard vertical-cavity surface-emitting lasers (VCSEL) platform can achieve a compact and powerful solution to provide on-chip light sources for biosensing applications. Here, a high sensitivity and label-free integrated VCSELs sensor was developed as a suitable analysis technique for COVID-19 specific receptor binding domain (RBD) protein. The gold nanograting array is integrated on VCSELs to realize the integrated microfluidic plasmonic biosensor of on-chip biosensing. The 850 nm VCSELs are used as a light source to excite the localized surface plasmon resonance (LSPR) effect of the gold nanograting array to detect the concentration of attachments. The refractive index sensitivity of the sensor is 2.99 × 106 nW/RIU. The aptamer of RBD was modified on the surface of the gold nanograting to detect the RBD protein successfully. The biosensor has high sensitivity and a wide detection range of 0.50 ng/mL - 50 µg/mL. This VCSELs biosensor provides an integrated, portable, and miniaturized idea for biomarker detection.


Assuntos
Técnicas Biossensoriais , COVID-19 , Humanos , Microfluídica , SARS-CoV-2 , Proteínas de Transporte , COVID-19/diagnóstico , Técnicas Biossensoriais/métodos , Ressonância de Plasmônio de Superfície/métodos , Lasers , Ouro/química
3.
Opt Express ; 30(21): 38503-38512, 2022 Oct 10.
Artigo em Inglês | MEDLINE | ID: mdl-36258414

RESUMO

Graphene has unique advantages in ultrabroadband detection. However, nowadays graphene-based photodetectors cannot meet the requirements for practical applications due to their poor performance. Here, we report a graphene-silicon-graphene Schottky junction photodetector assisted by field effect. Two separate graphene sheets are located on both sides of the n-doped silicon to form two opposite lateral series heterojunctions with silicon, and a transparent top gate is designed to modulate the Schottky barrier. Low doping concentration of silicon and negative gate bias can significantly raise the barrier height. Under the combined action of these two measures, the barrier height increases from 0.39 eV to 0.77 eV. Accordingly, the performance of the photodetector has been greatly improved. The photoresponsivity of the optimized device is 2.6 A/W at 792 nm, 1.8 A/W at 1064 nm, and 0.42 A/W at 1550 nm, and the on/off photo-switching ratio reaches 104. Our work provides a feasible solution for the development of graphene-based optoelectronic devices.

4.
Opt Express ; 29(2): 1481-1491, 2021 Jan 18.
Artigo em Inglês | MEDLINE | ID: mdl-33726362

RESUMO

Vertical-cavity surface-emitting lasers (VCSELs) play a key role in the development of the next generation of optoelectronic technologies, thanks to their unique characteristics, such as low-power consumption, circular beam profile, high modulation speed, and large-scale two-dimensional array. Dynamic phase manipulation of VCSELs within a compact system is highly desired for a large variety of applications. In this work, we incorporate the emerging microfluidic technologies into the conventional VCSELs through a monolithic integration approach, enabling dynamic phase control of lasing emissions with low power consumption and low thermal generation. As a proof of concept, a beam steering device is experimentally demonstrated by integrating microfluidic channel on a coherently coupled VCSELs array. Experimental results show that the deflection angles of the laser beam from the chip can be tuned from 0° to 2.41° under the injection of liquids with different refractive index into the microchannel. This work opens an entirely new solution to implement a compact laser system with real-time wavefront controllability. It holds great potentials in various applications, including optical fiber communications, laser printing, optical sensing, directional displays, ultra-compact light detection and ranging (LiDAR).

5.
Opt Express ; 29(15): 23234-23243, 2021 Jul 19.
Artigo em Inglês | MEDLINE | ID: mdl-34614591

RESUMO

Graphene is an ideal material for wide spectrum detector owing to its special band structure, but its low light absorption and fast composite of photogenerated carriers lead to a weak response performance. In this paper, we designed a unique photoconductive graphene-InGaAs photodetector. The built-in electric field was formed between graphene and InGaAs, which can prolong the lifetime of photogenerated carriers and improve the response of devices by confining the holes. Compared with graphene-Si structure, a higher built-in electric field and reach to 0.54 eV is formed. It enables the device to achieve a responsivity of 60 AW-1 and a photoconductive gain of 79.4 at 792 nm. In the 1550 nm communication band, the responsivity of the device is also greater than 10 AW-1 and response speed is less than 2 ms. Meanwhile, the saturation phenomenon of light response was also found in this photoconductive graphene heterojunction detector during the experiment, we have explained the phenomenon by the capacitance theory of the built-in electric field, and the maximum optical responsivity of the detector is calculated theoretically, which is in good agreement with the measurement result.

6.
Nanotechnology ; 32(2): 025301, 2021 Jan 08.
Artigo em Inglês | MEDLINE | ID: mdl-32957087

RESUMO

Surface plasmon resonance (SPR) of metal nanostructures has broad application prospects in the fields of sensing, energy, catalysis and optics. This paper reports a graphene-assisted method for preparing large-scale single-crystal Ag(111) nanoparticle (NP) arrays based on the ion implantation technique. By surface periodic patterning treatment and annealing of the implanted sample, regularly arranged Ag NPs can be prepared on the sample surface. A new application for graphene is proposed, that is, as a perfect barrier layer to prevent metal atoms from evaporating or diffusing. All the Ag NPs show (111) crystal orientation. Besides, the Ag atoms are covered by graphene immediately when they precipitate from the substrate, which can prevent them from being oxidized. On the basis of this structure, as one of the applications of the metal SPR, we have measured the surface-enhanced Raman scattering effect and found that the G peak of the Raman spectrum of the graphene achieved about 20 times enhancement.

7.
Opt Express ; 27(2): 774-782, 2019 Jan 21.
Artigo em Inglês | MEDLINE | ID: mdl-30696158

RESUMO

We apply the antenna coherence theory in order to evaluate characteristic behavior of phase-coherent VCSEL arrays. Large 19-element phase-locked VCSEL arrays with a near-diffraction-limited beam were firstly realized using proton implantation technology. The central lobe intensity is about four times that of side lobes in far-field patterns. The angular full width at half maximum (FWHM) of the far field lobes is only 1.42 degrees. A good matching between theory and experiment opens new perspectives for optimizing devices.

8.
Opt Express ; 27(10): 13910-13922, 2019 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-31163848

RESUMO

Beam steering devices have wide applications in both military and civil fields. The ultimate goal for such devices is to reduce their size, weight, and power consumption. However, the laser source in these devices is spatially separate from the phase shifter, resulting in large size, complex packaging, and low coupling efficiency. To solve these problems, a novel electrically controlled beam steering chip based on coherently coupled vertical cavity surface emitting laser (VCSEL) array directly integrated with liquid crystal optical phased array (LCOPA) is proposed in this paper. Implant-defined in-phase coherently coupled VCSEL arrays (CCVAs) with uniform near-field are designed and fabricated first to act as the coherent laser source for the chip. Then, taking advantage of the CCVA planar structure, the LCOPA is integrated directly on the CCVA by conventional process. The coherent light generated by the in-phase CCVA is uniformly and normally incident into the LCOPA and is electrically steered by the LCOPA. One-dimensional beam steering is achieved by two proof-of-concept integrated chips. The chips based on a 4 × 4 square CCVA and a 16-element hexagonal CCVA offer a field of view of 2.21° and 6.06°, respectively. Independent control of the CCVA and LCOPA guarantees a relatively high wavelength stability and power stability. Theoretical calculations are also performed, which are consistent with the experiments.

9.
Nanotechnology ; 29(36): 365301, 2018 Sep 07.
Artigo em Inglês | MEDLINE | ID: mdl-29901454

RESUMO

Chemical vapor deposited graphene suffers from two problems: transfer from metal catalysts to insulators, and photoresist induced degradation during patterning. Both result in macroscopic and microscopic damages such as holes, tears, doping, and contamination, translated into property and yield dropping. We attempt to solve the problems simultaneously. A nickel thin film is evaporated on SiO2 as a sacrificial catalyst, on which surface graphene is grown. A polymer (PMMA) support is spin-coated on the graphene. During the Ni wet etching process, the etchant can permeate the polymer, making the etching efficient. The PMMA/graphene layer is fixed on the substrate by controlling the surface morphology of Ni film during the graphene growth. After etching, the graphene naturally adheres to the insulating substrate. By using this method, transfer-free, lithography-free and fast growth of graphene realized. The whole experiment has good repeatability and controllability. Compared with graphene transfer between substrates, here, no mechanical manipulation is required, leading to minimal damage. Due to the presence of Ni, the graphene quality is intrinsically better than catalyst-free growth. The Ni thickness and growth temperature are controlled to limit the number of layers of graphene. The technology can be extended to grow other two-dimensional materials with other catalysts.

10.
Appl Opt ; 55(20): 5439-43, 2016 Jul 10.
Artigo em Inglês | MEDLINE | ID: mdl-27409323

RESUMO

Implant-defined vertical-cavity surface-emitting laser (VCSEL) arrays can be designed to operate in in-phase mode. However, the nonuniformities in fabrication process impact the resonance selection and the devices do not follow expected trends. Coherent coupling was demonstrated in three-element VCSEL arrays via phase tuning of elements. In-phase mode and out-of-phase mode were both achieved in most of the arrays. Moreover, coherent coupling can decrease the threshold current of elements in the array. Improved output power was also clearly observed when the array operated in the in-phase mode. Arbitrary phase combination of the array elements can be obtained via the phase tuning. This technology is able to improve the reproducibility and practicability of the implant-defined coherently coupled VCSEL array.

11.
Opt Express ; 23(17): 22883-9, 2015 Aug 24.
Artigo em Inglês | MEDLINE | ID: mdl-26368255

RESUMO

We report aluminum based structures for manipulation of surface plasmon polariton (SPP) propagation at short wavelength range. Our simulation shows that aluminum is a good metal to excite and propagate SPPs with blue light and that the SPP wavelength can be reduced from about 465 nm to about 265 nm by monitoring the thickness of a coated Si(3)N(4) layer above the aluminum film. It is also shown that the damping becomes more significant with the increase of the thickness of the Si(3)N(4) layer. We also experimentally demonstrated the SPP wavelength tuning effect for 20nm Si(3)N(4) layer covered Al, which can be explained by the variation of effective permittivity. The proposed Metal-Insulator-Air (MIA) structures with SPP wavelength tuning ability have potential applications in 2D optics.

12.
Opt Lett ; 40(10): 2349-52, 2015 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-26393736

RESUMO

In-phase coherently coupled vertical cavity surface emitting laser (VCSEL) hexagonal arrays were fabricated using proton implantation. The near-field profiles, far-field profiles, and emission spectra under different injection currents were tested and analyzed. The arrays can maintain in-phase single mode in a considerably wide current range from 10 mA (I(th)) to 35 mA (3.5×I(th)), exhibiting excellent beam quality. The far-field divergence angle of the in-phase coupled array is 2.5 degrees. Approximately 29% of total power is localized in the central lobe. Compared with square structure arrays, hexagonal arrays can maintain a more stable in-phase mode because of stronger coupling among the elements. The maximum output power of 4.9 mW was obtained under pulse wave condition. The simulation of far-field was carried out to match the in-phase operation test results. The performance enhancement of the array is attainable if the condition of heat dissipation is better. The process procedure of proton implantation is relatively simple and of low cost. It can be used as an alternative to coherently coupled array implementations.

13.
Adv Mater ; 36(11): e2310493, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38033193

RESUMO

The concept of a quasi-bound state in a continuum (QBIC) has garnered significant attention in various fields such as sensing, communication, and optical switching. Within metasurfaces, QBICs offer a reliable platform that enables sensing capabilities through potent interactions between local electric fields and matter. Herein, a novel terahertz (THz) biosensor based on the integration of QBIC with graphene is reported, which enables multidimensional detection. The proposed biosensor is distinctive because of its ability to discern concentrations of ethanol and N-methylpyrrolidone in a wide range from 100% to 0%, by monitoring the changes in the resonance intensity and maximum wavelet coefficient. This approach demonstrates an excellent linear fit, which ensures robust quantitative analysis. The remarkable sensitivity of our biosensor enables it to detect minute changes in low-concentration solutions, with the lowest detection concentration value (LDCV) of 0.21 pg mL-1 . 2D wavelet coefficient intensity cards are effectively constructed through continuous wavelet transforms, which presents a more accurate approach for determining the concentration of the solution. Ultimately, the novel sensing platform offers a host of advantages, including heightened sensitivity and reusability. This pioneering approach establishes a new avenue for liquid-based terahertz biosensing.


Assuntos
Grafite , Comunicação , Eletricidade , Etanol , Vibração
14.
Biosens Bioelectron ; 254: 116220, 2024 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-38518564

RESUMO

As Alzheimer's disease prevalence continues to rise, there is an increasing demand for efficient on-chip biosensors capable of early biomarker detection. This study presents a novel biosensor chip leveraging vertical cavity surface emitting laser (VCSEL) technology, with Parylene C serving as the antibody coupling layer and utilizing a streamlined one-step antibody modification method. Integration of Parylene C enhances chip sensitivity from 34.28 µW/RIU to 40.32 µW/RIU. Moreover, post-testing removal of Parylene C enables chip reusability without significant alteration of results. The sensor demonstrates effective detection of Aß42, an Alzheimer's biomarker, exhibiting a linear range of 1-200 ng/mL and a detection limit of 0.26 ng/mL. These findings underscore the reusability and reliability of the ultrathin Parylene C-based VCSEL biosensor chip, highlighting its potential for point-of-care Alzheimer's disease diagnosis.


Assuntos
Doença de Alzheimer , Técnicas Biossensoriais , Polímeros , Xilenos , Humanos , Técnicas Biossensoriais/métodos , Doença de Alzheimer/diagnóstico , Reprodutibilidade dos Testes , Lasers , Biomarcadores
15.
Adv Mater ; 36(21): e2312303, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38372628

RESUMO

Multi-dimensional multiplexed metasurface holography extends holographic information capacity and promises revolutionary advancements for vivid imaging, information storage, and encryption. However, achieving multifunctional metasurface holography by forward design method is still difficult because it relies heavily on Jones matrix engineering, which places high demands on physical knowledge and processing technology. To break these limitations and simplify the design process, here, an end-to-end inverse design framework is proposed. By directly linking the metasurface to the reconstructed images and employing a loss function to guide the update of metasurface, the calculation of hologram can be omitted; thus, greatly simplifying the design process. In addition, the requirements on the completeness of meta-library can also be significantly reduced, allowing multi-channel hologram to be achieved using meta-atoms with only two degrees of freedom, which is very friendly to processing. By exploiting the proposed method, metasurface hologram containing up to 12 channels of multi-wavelength, multi-plane, and multi-polarization is designed and experimentally demonstrated, which exhibits the state-of-the-art information multiplexing capacity of the metasurface composed of simple meta-atoms. This method is conducive to promoting the intelligent design of multifunctional meta-devices, and it is expected to eventually accelerate the application of meta-devices in colorful display, imaging, storage and other fields.

16.
Quant Imaging Med Surg ; 14(2): 1729-1746, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38415159

RESUMO

Background: Vascular disrupting agents (VDAs) are known to specifically target preexisting tumoural vasculature. However, systemic side effects as safety or toxicity issues have been reported from clinical trials, which call for further preclinical investigations. The purpose is to gain insights into their non-specific off-targeting effects on normal vasculature and provide clues for exploring underlying molecular mechanisms. Methods: Based on a recently introduced platform consisting laser speckle contrast imaging (LSCI), chick embryo chorioallantoic membrane (CAM), and assisted deep learning techniques, for evaluation of vasoactive medicines, hemodynamics on embryonic day 12 under constant intravascular infusion of two VDAs were qualitatively observed and quantitatively measured in real time for 30 min. Blood perfusion, vessel diameter, vessel density, and vessel total length were further analyzed and compared between blank control and medicines dose groups by using multi-factor analysis of variance (ANOVA) analysis with factorial interactions. Conventional histopathology and fluorescent immunohistochemistry (FIHC) assays for endothelial cytoskeleton including ß-tubulin and F-actin were qualitatively demonstrated, quantitatively analyzed and further correlated with hemodynamic and vascular parameters. Results: The normal vasculature was systemically negatively affected by VDAs with statistical significance (P<0.0001), as evidenced by four positively correlated parameters, which can explain the side-effects observed among clinical patients. Such effects appeared to be dose dependent (P<0.0001). FIHC assays qualitatively and quantitatively verified the results and exposed molecular mechanisms. Conclusions: LSCI-CAM platform combining with deep learning technique proves useful in preclinical evaluations of vasoactive medications. Such new evidences provide new reference to clinical practice.

17.
Aging Dis ; 15(1): 390-407, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-37307837

RESUMO

Neuroinflammation plays a crucial role in the pathogenesis and progression of Alzheimer's disease (AD). The Sterile Alpha and Toll Interleukin Receptor Motif-containing protein 1 (SARM1) has been shown to promote axonal degeneration and is involved in neuroinflammation. However, the role of SARM1 in AD remains unclear. In this study, we found that SARM1 was reduced in hippocampal neurons of AD model mice. Interestingly, conditional knockout (CKO) of SARM1 in the central nervous system (CNS, SARM1Nestin-CKO mice) delayed the cognitive decline in APP/PS1 AD model mice. Furthermore, SARM1 deletion reduced the Aß deposition and inflammatory infiltration in the hippocampus and inhibited neurodegeneration in APP/PS1 AD model mice. Further investigation into the underlying mechanisms revealed that the signaling of tumor necrosis factor-α (TNF-α) was downregulated in the hippocampus tissues of APP/PS1;SARM1Nestin-CKO mice, thereby alleviating the cognitive decline, Aß deposition and inflammatory infiltration. These findings identify unrecognized functions of SARM1 in promoting AD and reveal the SARM1-TNF-α pathway in AD model mice.


Assuntos
Doença de Alzheimer , Camundongos , Animais , Doença de Alzheimer/genética , Nestina , Camundongos Transgênicos , Fator de Necrose Tumoral alfa , Doenças Neuroinflamatórias , Transtornos da Memória/genética , Proteínas do Citoesqueleto/genética , Proteínas do Domínio Armadillo/genética
18.
Nanomaterials (Basel) ; 13(8)2023 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-37110924

RESUMO

Graphene is an ideal material for flexible optoelectronic devices due to its excellent electrical and optical properties. However, the extremely high growth temperature of graphene has greatly limited the direct fabrication of graphene-based devices on flexible substrates. Here, we have realized in situ growth of graphene on a flexible polyimide substrate. Based on the multi-temperature-zone chemical vapor deposition cooperated with bonding a Cu-foil catalyst onto the substrate, the growth temperature of graphene was controlled at only 300 °C, enabling the structural stability of polyimide during growth. Thus, large-area high-quality monolayer graphene film was successfully in situ grown on polyimide. Furthermore, a PbS-graphene flexible photodetector was fabricated using the graphene. The responsivity of the device reached 105 A/W with 792 nm laser illumination. The in-situ growth ensures good contact between graphene and substrate; therefore, the device performance can remain stable after multiple bending. Our results provide a highly reliable and mass-producible path for graphene-based flexible devices.

19.
Technol Cancer Res Treat ; 22: 15330338231206985, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37844882

RESUMO

Conforming to the current replace-reduce-refine 3Rs' guidelines in animal experiments, a series of explorative efforts have been made to set up operable biomedical imaging-guided platforms for qualitative and quantitative evaluations on pharmacological effects of tumor vascular-disrupting agents (VDAs), based on the chick embryos (CEs) with its chorioallantoic membrane (CAM), in this overview. The techniques and platforms have been hierarchically elaborated, from macroscopic to microscopic and from overall to specific aspects. A protocol of LED lamplight associated with a new deep-learning algorithm was consolidated to screen out weak CEs by using the CAM vasculature imaging. 3D magnetic resonance imaging (MRI) and laser speckle contrast imaging (LSCI) to monitor the evolution of CE and vascular changes in CAM are introduced. A LSCI-CAM platform for studying the effects of VDAs on normal and cancerous vasculature of CAM and possible molecular mechanisms has been demonstrated. Finally, practical challenges and future perspectives are highlighted. The aim of this article is to help peers in biomedical research to familiarize with the CAM platform and to optimize imaging protocols for the evaluation of vasoactive pharmaceuticals, especially anticancer vascular targeted therapy.


Assuntos
Membrana Corioalantoide , Imageamento por Ressonância Magnética , Animais , Embrião de Galinha , Membrana Corioalantoide/irrigação sanguínea , Preparações Farmacêuticas
20.
Adv Mater ; 35(12): e2204286, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36111553

RESUMO

Metasurface polarization optics that consist of 2D array of birefringent nano-antennas have proven remarkable capabilities to generate and manipulate vectorial fields with subwavelength resolution and high efficiency. Integrating this new type of metasurface with the standard vertical cavity surface-emitting laser (VCSEL) platform enables an ultracompact and powerful solution to control both phase and polarization properties of the laser on a chip, which allows to structure a VCSEL into vector beams with on-demand wavefronts. Here, this concept is demonstrated by directly generating versatile vector beams from commercially available VCSELs through on-chip integration of high-index dielectric metasurfaces. Experimentally, the versatility of the approach for the development of vectorial VCSELs are validated by implementing a variety of functionalities, including directional emission of multibeam with specified polarizations, vectorial holographic display, and vector vortex beams generations. Notably, the proposed vectorial VCSELs integrated with a single layer of beam shaping metasurface bypass the requirements of multiple cascaded optical components, and thus have the potential to promote the advancements of ultracompact, lightweight, and scalable vector beams sources, enriching and expanding the applications of VCSELs in optical communications, laser manipulation and processing, information encryption, and quantum optics.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa