Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Artigo em Chinês | WPRIM | ID: wpr-1025002

RESUMO

【Objective】 To analyze the serological characteristics and molecular mechanism of a novel B subtype allele 803delC. 【Methods】 ABO blood group was detected by serological method. Sequence-specific primer polymerase chain reaction (PCR-SSP) was used to detect ABO blood group genes. The coding region of exon 1-7 of ABO gene was detected by Sanger sequencing to determine the mutation site. 【Results】 Serological identification of patients was with forward O-type and reverse B-type. The result of PCR-SSP genotyping was A/O. There was A gene, which was not consistent with serological results. Further Sanger double-strand sequencing revealed that the C-base was deleted at position 803 of exon 7 on the basis of ABO*B. 01/ABO*O. 01.01. The mutation eventually leads to the amino acid substitution of p. Ala268Gly and p. Phe269Ser and the production of new open reading frame starting at position 269, with the new open reading frame No.20 amino acid being stop codon, resulted in the termination of B gene expression. Further single-strand sequencing of the ABO gene revealed that the mutation was located in the ABO*B. 01 gene. The mutation was submitted to the NCBI database with the number OR343908. 【Conclusion】 A new ABO allele leading to B variant has been found in Chinese population. Genetic detection can be used to identify the ambiguous blood group with discrepancy between forward and reverse blood grouping.

2.
Artigo em Chinês | WPRIM | ID: wpr-621663

RESUMO

Objectire To identify specific biomarkers that could improve early diagnsis of lung adenuearcinoma using matrix-assisted laser desorptian/ionization (MALDI) technology. Methods Serum samples were isolated from 17 patients with stage I lung adenuearcinoma and 17 age- and sex-matched healthy controls, and the serum proteomic profiles were obtained by matrix-assistcd laser desorption ionization time of flight (MALDI-TOF) mass spectrometry. Results Compared with healthy control group, two highly expressed potential biomarkers were identified with the relative molecular weights of 6 631.64 Da and 4 964. 21 Da. The two best novel protein peaks were automatically chosen for the system training and the development of the constructed model. The constructed model was then used to test an independent set of masked serum samples from 15 lung adenocarcinoma patients and 22 healthy individuals. The analysis yielded a sensitivity of 93.3 %, and a specificity of 95.5 %. Conclusion These results suggest that MALDI-TOF-MS ProteinChip technology is a quick, convenient, and high-output analyzing method that is capable of selecting several relatively potential biomarkers from the serum of lung adenocarcinoma patients and may have a clinical value in the future, and will provide clues to identifying new serologic btomarkers of lung adenocarcinoma.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa