Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 24
Filtrar
1.
Am J Emerg Med ; 70: 157-162, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37327681

RESUMO

OBJECTIVES: The success of the manual pulse check method frequently employed during cardiopulmonary resuscitation (CPR) is controversial due to its subjective, patient- and operator-dependent, and time-consuming nature. Carotid ultrasound (c-USG) has recently emerged as an alternative, although there are still insufficient studies on the subject. The purpose of the present study was to compare the success of the manual and c-USG pulse check methods during CPR. METHODS: This prospective observational study was conducted in the critical care area of a university hospital emergency medicine clinic. Pulse checks in patients with non-traumatic cardiopulmonary arrest (CPA) undergoing CPR were performed using the c-USG method from one carotid artery and the manual method from the other. The gold standard in the decision regarding return of spontaneous circulation (ROSC) was the clinical judgment made using the rhythm on the monitor, manual femoral pulse check, end tidal carbon dioxide (ETCO2), and cardiac USG instruments. The success in predicting ROSC and measurement times of the manual and c-USG methods were compared. The success of both methods was calculated as sensitivity and specificity, and the clinical significance of the difference between the methods' sensitivity and specificity was evaluated Newcombe's method. RESULTS: A total of 568 pulse measurements were performed on 49 CPA cases using both c-USG and the manual method. The manual method exhibited 80% sensitivity and 91% specificity in predicting ROSC (+PV: 35%, -PV: 64%), while c-USG exhibited 100% sensitivity and 98% specificity (+PV: 84%, -PV: 100%). The difference in sensitivities between the c-USG and manual methods was -0.0704 (95% CI: -0.0965; -0.0466), and the difference between their specificities was 0.0106 (95% CI: 0.0006; 0.0222). The difference between the specificities and sensitivities was statistically significant at analysis performed adopting the clinical judgment of the team leader using multiple instruments as the gold standard. The manual method yielded an ROSC decision in 3 ± 0.17 s and c-USG in 2.8 ± 0.15 s, the difference being statistically significant. CONCLUSION: According to the results of this study, the pulse check method with c-USG may be superior to the manual method in terms of fast and accurate decision making in CPR.


Assuntos
Reanimação Cardiopulmonar , Parada Cardíaca , Parada Cardíaca Extra-Hospitalar , Humanos , Reanimação Cardiopulmonar/métodos , Parada Cardíaca/terapia , Sensibilidade e Especificidade , Artérias Carótidas/diagnóstico por imagem , Dióxido de Carbono
2.
J Ultrasound Med ; 41(3): 637-644, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33987920

RESUMO

OBJECTIVE: Recently, a cardiac sonography finding, early systolic notching (ESN), was reported with high sensitivity and specificity for the diagnosis of pulmonary embolism (PE) in a limited population. The aim of this study was to determine the diagnostic accuracy of ESN finding for PE in emergency department (ED) patients. METHOD: This prospective multicenter study was conducted in 4 academic EDs. All patients who underwent computed tomography angiography for suspected PE were included in the study. After inclusion, cardiac ultrasound including the right ventricular outflow tract Doppler signal was performed. The diagnostic tests of ESN finding were used for PE and its subgroups. RESULTS: In the study, 183 of 201 patients met the study criteria. Of all patients, 52.5% had PE (n = 96), and 19.7% (n = 36) had ESN finding. In all ED patients, the sensitivity of ESN for PE was 34% (95% CI 25-45), and the specificity was 97% (95% CI 90-99). In the subgroup analysis, the sensitivity of ESN for PE with high or intermediate-high risk was 69% (95% CI 49-85), and the specificity was 90% (95% CI 84-94). Inter-rater reliability for ESN finding between the cardiologist and emergency physician was strong with a kappa statistic of 0.87. CONCLUSION: The pulmonary Doppler flow of ESN was moderate to high specific but low sensitive for PE in all ED patients. In the subgroup analysis, this finding was moderate specific and low sensitive.


Assuntos
Embolia Pulmonar , Angiografia por Tomografia Computadorizada , Serviço Hospitalar de Emergência , Humanos , Estudos Prospectivos , Embolia Pulmonar/diagnóstico por imagem , Reprodutibilidade dos Testes , Ultrassonografia
3.
J Emerg Med ; 60(6): e151-e153, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33640216

RESUMO

BACKGROUND: Emphysematous cholecystitis (EC) is a form of cholecystitis with high mortality rates more commonly seen in patients with medical histories such as diabetes, hypertension, and peripheral vascular disease. The common features of these medical diseases are impaired pain perception, particularly abdominal pain, due to advanced age and peripheral neuropathies. Accurate evaluation of characteristics observed at ultrasonography, the method of first choice in the diagnosis of EC, is therefore highly important in these patients. CASE REPORT: This study reports a case of the champagne sign, rarely seen in EC, together with other EC findings. WHY SHOULD AN EMERGENCY PHYSICIAN BE AWARE OF THIS?: The champagne sign is a little-known sonographic finding that is evidence of the presence of gas in the gallbladder. The champagne sign that will be detected while evaluating the hepatobiliary system on bedside ultrasound is one of the valuable findings in the diagnosis of emphysematous cholecystitis with high mortality.


Assuntos
Colecistite , Colecistite Enfisematosa , Doenças do Sistema Nervoso Periférico , Colecistite/complicações , Colecistite/diagnóstico por imagem , Colecistite Enfisematosa/complicações , Colecistite Enfisematosa/diagnóstico por imagem , Humanos , Ultrassonografia
4.
J Clin Ultrasound ; 49(2): 159-163, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32856315

RESUMO

Right-sided heart failure (RHF) diagnosed at point-of-care-ultrasonography examination of critical patients may reveal an acute disease, such as pulmonary embolism (PE), requiring emergency thrombolytic treatment. However, acute respiratory distress syndrome (ARDS) and PE leading to acute RHF may exhibit very similar echocardiographic features. We report the case of a 27-year-old pregnant woman diagnosed with ARDS due to septic abortion, and in whom ARDS mimicked PE both clinically and on echocardiography. Such similarity may lead to inappropriate administration of thrombolytic therapy and/or delay the correct treatment. Lung ultrasonography may help avoiding this pitfall.


Assuntos
Ecocardiografia , Pulmão/diagnóstico por imagem , Embolia Pulmonar/complicações , Síndrome do Desconforto Respiratório/complicações , Síndrome do Desconforto Respiratório/diagnóstico por imagem , Adulto , Estado Terminal , Feminino , Humanos , Gravidez
5.
Am J Emerg Med ; 38(11): 2487.e7-2487.e12, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32536478

RESUMO

The clinical course of COVID-19 presents a broad spectrum, being asymptomatic in some individuals while following a severe course and resulting in mortality in others. It is known that such factors as age and chronic diseases can result in a different clinical courses in individuals, however, variable clinical courses among the similar individuals in terms of age and chronic diseases are also seen. Other possible factors affecting the course of the disease that are mostly speculative or under investigation are genetic factors and the origin of transmission or possible subtype of novel coronavirus. Whether the source of transmission is important in the clinical course of the disease is unknown. A case series composed of seven individuals in a similar age group, with different lines of descent and different genetic structures, but who were infected from the same source is presented here. The similar and different clinical, laboratory and radiological findings of the cases residing in the same nursing home, who presented to the hospital altogether, were evaluated. The aim of the study was to analyze whether the source of transmission is influential in the clinical course of the disease.


Assuntos
COVID-19/diagnóstico , Idoso , Idoso de 80 Anos ou mais , COVID-19/genética , COVID-19/fisiopatologia , Comorbidade , Feminino , Genótipo , Humanos , Masculino , Fenótipo , Índice de Gravidade de Doença , Turquia
6.
J Ultrasound Med ; 39(2): 231-238, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31283047

RESUMO

OBJECTIVES: Although inferior vena cava diameter (IVCD) measurement can be useful as a noninvasive method for monitoring the volume status, the benefit of abdominal aorta diameter (AAD) measurement is unclear. The purpose of this study was to determine the value of the combined use of the IVCD and AAD in blood loss monitoring. METHODS: This prospective observational study was conducted at the blood donor center of a training and research hospital. Standard blood donation criteria were followed during volunteer enrollment. Vital signs and ultrasound IVCD and AAD measurements were obtained before and after blood donation and after fluid resuscitation with 500 mL of 0.9% sodium chloride. Measurements before and after blood donation and after fluid resuscitation were compared by the paired t and Wilcoxon matched-pair tests. RESULTS: Thirty-nine volunteers were included in the study. With 500 mL of blood loss, percent changes in the shock index (SI; mean ± SD, 7% ± 6%), IVCD (6% ± 2%), and caval/aorta index (IVCD/AAD; 6.1% ± 3%) were similar and were higher (P < .001 for all parameters) than the changes in the pulse rate (3% ± 4%), AAD (0.5% ± 1.5%), systolic blood pressure (3% ± 4%), and diastolic blood pressure (2% ± 7%). Although IVCD and SI values changed significantly (P < .001 for both) after 500 mL of 0.9% sodium chloride resuscitation, no significant change was observed in the IVCD/AAD (P = .059). CONCLUSIONS: The IVCD/AAD, SI, and IVCD may have similar success rates in diagnosing early blood loss. Additionally, the SI and IVCD may be superior to the IVCD/AAD in bleeding patients requiring simultaneous fluid resuscitation.


Assuntos
Aorta Abdominal/diagnóstico por imagem , Voluntários Saudáveis , Veia Cava Inferior/diagnóstico por imagem , Adolescente , Adulto , Doadores de Sangue , Volume Sanguíneo , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Ressuscitação , Choque/diagnóstico por imagem , Choque/fisiopatologia
7.
J Emerg Med ; 58(4): 553-561, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32070647

RESUMO

BACKGROUND: The local anesthetic dosages used in the current literature in regional applications of local anesthetics are frequently high for surgical purposes, and there are no sufficient dosage studies for emergency department (ED) management. OBJECTIVES: The aim of this study was to determine the success of lower local anesthetic dosages capable of reducing costs and excessive exposure to drugs in pain control in patients with femoral neck fractures (FNFs) in the ED. METHODS: Patients ≥65 years of age with FNFs and reporting Wong-Baker Pain Rating Scales scores ≥8 were included in this prospective, interventional study. Patients underwent ultrasound-guided regional femoral block with 5 mL 2% prilocaine. Pain scores before the procedure and at 30 min and 2 h postprocedure were compared with the Friedman test and Wilcoxon test with Bonferroni correction. RESULTS: Forty patients, 20 with intracapsular and 20 with extracapsular FNFs, were enrolled. The initial pain scores of patients with both intra- and extracapsular fractures were 8 (range 8-10). A statistically significant 50% decrease in pain scores was observed in both groups 30 min after the regional block procedure (p < 0.001). A statistically significant 75% decrease in pain scores was observed in both groups 2 h after the regional block procedure (p < 0.001). No statistically significant difference was determined in the change in 30-min and 2-h pain scores between the groups. CONCLUSIONS: The administration of 5 mL 2% prilocaine for pain control in FNFs in elderly patients in the ED can reduce systemic analgesic requirements by establishing effective analgesia in both intracapsular and extracapsular fractures.


Assuntos
Fraturas do Quadril , Bloqueio Nervoso , Idoso , Anestésicos Locais/uso terapêutico , Estudos de Viabilidade , Nervo Femoral , Fraturas do Quadril/cirurgia , Humanos , Estudos Prospectivos , Ultrassonografia de Intervenção
8.
J Ultrasound Med ; 38(4): 1027-1038, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30265408

RESUMO

OBJECTIVES: The purpose of this study was to determine the success of mitral valve movements in the estimation of left ventricular ejection fraction (LVEF). METHODS: Adult patients whose principal symptom was dyspnea were included in this prospective observational study. The distance from the anterior mitral valve (AMV) to the interventricular septum (IVS) during early diastole was measured first in B-mode in the parasternal long axis (PLAX) named parasternal long axis-anterior leaflet septal separation. Second, the AMV-IVS distance was measured in M-mode in the PLAX named E-point septal separation. Third, AMV-IVS distance was measured in B-mode in the apical 4-chamber view named apical 4-chamber view-anterior leaflet septal separation. Finally, maximum distance between the 2 mitral leaflets in the apical 4-chamber view was measured and named mitral valve leaflet separation. Comprehensive echocardiography was performed by an experienced cardiologist. Correlation was calculated between mitral valve measurements and LVEF. Cutoff values were determined using receiver operating characteristic curves and the chi-square test. RESULTS: A total of 118 patients were included in the study. Parasternal long axis-anterior leaflet septal separation, E-point septal separation, and apical 4-chamber view-anterior leaflet septal separation were highly correlated with LVEF (correlation coefficient, -0.848, -0.833, and-0.822 [P < .001]). Parasternal long axis-anterior leaflet septal separation values less than 2.30 mm, E-point septal separation values less than 2 mm, and mitral valve leaflet separation values greater than 25.15 mm exhibited a 100% negative predictive value in excluding reduced LVEF. Parasternal long axis-anterior leaflet septal separation values less than 4.95 mm, EPSS values less than 5.85 mm, apical 4-chamber view-anterior leaflet septal separation values less than 6.95 mm, and mitral valve leaflet separation values greater than 24.05 mm exhibited a 100% negative predictive value in excluding severe reduced LVEF. CONCLUSIONS: Mitral valve measurement methods may be useful in predicting LVEF or values thereof as a complementary method of diagnosing challenging patients on echocardiographic images.


Assuntos
Dispneia/fisiopatologia , Ecocardiografia/métodos , Valva Mitral/diagnóstico por imagem , Valva Mitral/fisiopatologia , Sístole/fisiologia , Idoso , Serviço Hospitalar de Emergência , Feminino , Humanos , Masculino , Sistemas Automatizados de Assistência Junto ao Leito , Estudos Prospectivos
9.
J Clin Ultrasound ; 47(5): 278-284, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30873632

RESUMO

OBJECTIVES: Blood hemoglobin concentration measurements using a spectrophotometric method (SpHb), and inferior vena cava ultrasonography (IVC-US) are noninvasive methods used to follow-up hemorrhages. We compared their efficacy using voluntary blood donation as a model of moderate (approx. 500 mL) blood loss. METHODS: In this prospective observational study enrolling blood-donor volunteers (BD) and matched controls, we recorded SpHb, IVC diameters, and vital signs. Changes in variables from baseline were compared between BD and controls using the paired t test and Wilcoxon signed rank test. RESULTS: We included 118 subjects in the BD group and 95 healthy subjects in the control group. Changes in IVC maximum diameter, IVC minimum diameter, pulse rate, mean arterial pressure, pulse pressure, and shock index, but not in other variables, were significantly different in the BD and the control group (P < 0.05). IVCmax ≥1.1 mm yielded a 74% sensitivity and 77% specificity (PPV 79.8%, NPV 70.2%) in detecting early hemorrhage. With these cutoff values, IVCmax or PR reached a 90% sensitivity, while IVCmin and PR reached 98% specificity. CONCLUSIONS: IVC ultrasound may be superior to SpHb in predicting blood loss and may be useful in addition to vital signs for its follow-up.


Assuntos
Hemoglobinas/metabolismo , Hemorragia/diagnóstico por imagem , Veia Cava Inferior/diagnóstico por imagem , Adolescente , Adulto , Biomarcadores/sangue , Doadores de Sangue , Estudos de Casos e Controles , Diagnóstico Precoce , Feminino , Voluntários Saudáveis , Hemorragia/sangue , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Sensibilidade e Especificidade , Espectrofotometria , Ultrassonografia , Sinais Vitais , Adulto Jovem
10.
J Clin Ultrasound ; 46(9): 605-609, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-29479764

RESUMO

New substances are constantly being added to the content of synthetic cannabinoids (SCs). SCs can affect the cardiovascular system and cause hypotension and bradycardia, myocardial infarction, atrial fibrillation, prolonged QTc, and Mobitz type II atrioventricular block. However, no cases associated with ventricular fibrillation (VF) have been reported to date. We report a case of a 26-year-old male patient admitted to the emergency department due to altered consciousness after SC use and requiring prolonged cardiopulmonary resuscitation due to resistant VF and cardiogenic shock.


Assuntos
Canabinoides/efeitos adversos , Coração/efeitos dos fármacos , Coração/fisiopatologia , Drogas Ilícitas/efeitos adversos , Choque Cardiogênico/induzido quimicamente , Fibrilação Ventricular/induzido quimicamente , Adulto , Coração/diagnóstico por imagem , Humanos , Masculino , Choque Cardiogênico/diagnóstico por imagem , Choque Cardiogênico/fisiopatologia , Ultrassonografia , Fibrilação Ventricular/diagnóstico por imagem , Fibrilação Ventricular/fisiopatologia
12.
Am J Emerg Med ; 33(3): 433-8, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25616587

RESUMO

OBJECTIVES: This study aims to determine the site of and the best sonographic method for measurement of inferior vena cava (IVC) diameter in volume status monitoring. METHODS: This observational before-and-after study was performed at the intensive care unit of the emergency department. It included hypotensive adult patients with suspected sepsis who were recommended to receive at least 20 mg/kg fluid replacement by the emergency physician. The patients were fluid replaced at a rate of 1000 mL/h, and maximum and minimum IVC diameters were measured and the Caval index calculated sonographically via both B-mode and M-mode. Hence, IVC's volume response was assessed by a total of 6 parameters, 3 each in M-mode and B-mode. Freidman test was used to assess the change in IVC diameter with fluid replacement. Wilcoxon test with Bonferroni correction was used to determine which measurement method more sensitively measured IVC diameter change. RESULTS: Twenty-eight patients with a mean age of 71.3 were included in the final analysis.The IVC diameter change was significant with all 6 methods (P < .001). The IVC minimum diameter change measured on M-mode during inspiration (M-mode i) was the only measurement method that significantly showed diameter change with each 500-mL fluid replacements. The initial and the subsequent M-mode i values after each 500 mL of fluid were 5.65 ± 3.34; 8.05 ± 3.66; 10.16 ± 3.61, and 11.21 ± 2.94, respectively (P < .001, P < .002, and P < .003, respectively). CONCLUSION: Inferior vena cava diameter was changed by fluid administration. The M-mode i method that most sensitively measures that change may be the most successful method in volume status monitoring.


Assuntos
Hidratação , Hipotensão/diagnóstico por imagem , Veia Cava Inferior/diagnóstico por imagem , Desequilíbrio Hidroeletrolítico/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Serviço Hospitalar de Emergência , Feminino , Humanos , Hipotensão/etiologia , Hipotensão/terapia , Masculino , Pessoa de Meia-Idade , Tamanho do Órgão , Estudos Prospectivos , Sepse/complicações , Ultrassonografia , Desequilíbrio Hidroeletrolítico/etiologia , Desequilíbrio Hidroeletrolítico/terapia
13.
Am J Emerg Med ; 33(3): 396-401, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25612468

RESUMO

STUDY OBJECTIVE: We aimed to determine the role of inferior vena cava (IVC) diameter in making a differentiation between dyspnea of cardiac (acute heart failure [AHF]) and pulmonary origin. We also attempted to determine the best sonographic method for the measurement of IVC diameter. METHODS: This prospective observational study was conducted at the intensive care unit of the emergency department of a training and research hospital. This study enrolled patients with the main symptom of dyspnea who were categorized into 2 groups, cardiac dyspnea and pulmonary dyspnea groups, based on the final diagnosis. All patients underwent sonographic measurement of minimum and maximum diameters of IVC, and the caval index (CI) was calculated in both M-mode and B-mode. The sensitivity, specificity, and likelihood ratios (LR) of the IVC values for the differentiation of the 2 groups were calculated. RESULTS: This study included a total of 74 patients with a mean age of 72.8 years. Thirty-two patients had dyspnea of cardiac origin, and 42 patients had dyspnea of pulmonary origin. The IVC diameter measured with B-mode during inspiration (B-mode i) was the most successful method for differentiation of the 2 groups. B-mode i values greater than 9 mm predicted dyspnea of cardiac origin with a sensitivity of 84.4% and a specificity of 92.9% (+LR: 11.8, LR: 0.16). CONCLUSION: Sonographic assessment of the IVC diameter may be used as a rapid, readily, nonexpensive, complication-free, and reproducible technique for the differentiation of cardiac and pulmonary causes of dyspnea. B-mode i measurement may be more successful in the differentiation of dyspnea compared with other IVC diameters and calculations.


Assuntos
Dispneia/etiologia , Insuficiência Cardíaca/diagnóstico , Pneumonia/diagnóstico , Doença Pulmonar Obstrutiva Crônica/diagnóstico , Embolia Pulmonar/diagnóstico , Veia Cava Inferior/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Área Sob a Curva , Diagnóstico Diferencial , Progressão da Doença , Ecocardiografia , Serviço Hospitalar de Emergência , Feminino , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/diagnóstico por imagem , Humanos , Unidades de Terapia Intensiva , Masculino , Pessoa de Meia-Idade , Peptídeo Natriurético Encefálico/sangue , Tamanho do Órgão , Pneumonia/complicações , Pneumonia/diagnóstico por imagem , Estudos Prospectivos , Doença Pulmonar Obstrutiva Crônica/complicações , Doença Pulmonar Obstrutiva Crônica/diagnóstico por imagem , Embolia Pulmonar/complicações , Embolia Pulmonar/diagnóstico por imagem , Sensibilidade e Especificidade , Veia Cava Inferior/patologia
14.
Respir Care ; 67(5): 562-571, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35473843

RESUMO

BACKGROUND: Noninvasive ventilation (NIV) is one of the most important therapeutic tools in patients with acute respiratory failure. However, in case of incorrect patient selection it can delay necessary intubation and is associated with complications and even mortality. Patient selection, therefore, plays a key role in therapeutic success. The purpose of this study was to determine the value of the rapid shallow breathing index (RSBI) in predicting the failure of NIV. METHODS: This prospective observational study was conducted in the emergency department (ED) of a tertiary hospital. Adults presenting to the ED with acute respiratory failure were included in the study. The success of RSBI values measured initially (RSBI 1) and at 30 min (RSBI 2) and the difference between these 2 values (Δ RSBI) in predicting subjects' intubation requirement and survival was tested using multivariate logistic regression analysis. RESULTS: Two hundred sixty-seven subjects were included in the study. RSBI 1, RSBI 2, and Δ RSBI values differed significantly between the intubated and non-intubated subjects. According to the multivariate model, RSBI 1 and RSBI 2 > 105, Δ RSBI < 19, heart rate > 100 beats/min, and SpO2 < 92% were significantly associated with intubation requirement. RSBI 1, RSBI 2, and Δ RSBI values also differed significantly between subjects with a fatal course and surviving individuals. According to the multivariate model, RSBI 2 > 105, Δ RSBI < 19, heart rate > 100, and increasing age were associated with in-hospital mortality. CONCLUSIONS: RSBI can be a successful marker in predicting the failure of NIV and predicting in-hospital mortality in patients admitted to the ED with acute respiratory failure.


Assuntos
Insuficiência Respiratória , Desmame do Respirador , Adulto , Mortalidade Hospitalar , Humanos , Intubação Intratraqueal , Respiração Artificial , Insuficiência Respiratória/terapia
15.
Turk J Emerg Med ; 22(2): 75-82, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35529029

RESUMO

OBJECTIVES: Intravenous (IV) calcium salts are routinely recommended as a cardio-protective therapy in the emergency treatment of severe hyperkalemia. However, this recommendation is supported by a low level of evidence and is anecdotal. The aim of this study is to determine the effectiveness of IV Calcium (Ca) gluconate in the treatment of hyperkalemia. MATERIALS AND METHODS: Patients with hyperkalemia and with the electrocardiogram (ECG) changes due to hyperkalemia over a 1 year period were included in this prospective observational study. Patients' ECGs were measured, before and after IV Ca-gluconate treatment and after normalization of potassium levels. Wilcoxon test and McNemar's test were used to compare the ECG parameters before and after Ca-gluconate therapy. RESULTS: The mean potassium value of 111 patients who met the inclusion criteria was 7.1 ± 0.6 mmol/l. In this study, a total of 243 ECG pathology related to hyperkalemia, 79 of which included main rhythm disorders, and the remaining 164 were nonrhythm disorders in ECG parameters, were analyzed. No statistically significant changes were determined in patients' nonrhythm ECG disorders with IV Ca-gluconate treatment (P = 0.125). However, nine of the 79 main rhythm disorders due to hyperkalemia improved with calcium gluconate treatment and this change was statistically significant (P < 0.004). CONCLUSION: IV Ca-gluconate therapy was found to be effective, albeit to a limited degree, in main rhythm ECG disorders due to hyperkalemia, but it was not found to be effective in nonrhythm ECG disorders due to hyperkalemia. Therefore, Ca-gluconate may be effective only in the main rhythm disorders due to hyperkalemia.

16.
Turk J Emerg Med ; 22(3): 159-162, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35936949

RESUMO

Cardiopulmonary resuscitation (CPR) to be applied during patient transfer by ambulance differs from CPR applied in the field or in the hospital in terms of physical condition. Especially the deeper and faster chest compressions recommended in the latest CPR guidelines, when administered during ambulance transport, may result in a further increase in traumatic CPR complications. However, in the current CPR guidelines, there are no clear recommendations regarding additional measures that can be taken to reduce the complications and increase the efficiency of CPR during patient transport. In this study, a case of flail chest that developed after short-term CPR application during ambulance transport is presented. The aim of this study was to evaluate the flail chest complication and solution suggestions that may occur due to chest compressions applied during transportation.

18.
Braz J Anesthesiol ; 71(4): 461-463, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33766684

RESUMO

Noninvasive mechanical ventilation (NIMV) has a relevant role in the treatment of critically ill patients displaying severe dyspnea. Continuous positive airway pressure (CPAP), a method of NIMV, is also widely used in the management of acute heart failure, chronic obstructive pulmonary disease (COPD) exacerbation, and symptomatic sleep apnea. However, numerous traumatic complications of CPAP treatment in the face region, head, and thorax have been reported and may be related to the application of a continuous positive high pressure to the airway. Conversely, we have observed no complications due to CPAP-related increased intra-abdominal pressure. In this article, we describe a clinical case of a patient with an acute rectus sheath hematoma during CPAP treatment. This previously unreported complication demonstrates that CPAP should be carefully used in patients with exacerbated COPD with difficulty in expiration.


Assuntos
Pressão Positiva Contínua nas Vias Aéreas , Doença Pulmonar Obstrutiva Crônica , Hematoma/diagnóstico por imagem , Hematoma/etiologia , Humanos , Doença Pulmonar Obstrutiva Crônica/complicações , Doença Pulmonar Obstrutiva Crônica/terapia
19.
Turk J Emerg Med ; 21(4): 198-204, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34849432

RESUMO

OBJECTIVES: Limited clinical studies have investigated the effects of synthetic cannabinoids (SCs) on the cardiovascular system (CVS). The aim of this study was to evaluate the effects of SCs on the CVS. METHODS: The patient group of this single-center, prospective, case-control study consisted of adult patients presenting to the emergency department (ED) with symptoms of SC use. Vital signs and electrocardiogram (ECG) after use of SC of patients were followed. A control group with a similar number of patients and patient demographics were formed following the patient admission process. Pulse rate, arterial blood pressure (ABP), and ECG of patient and control groups were compared using Mann-Whitney U and Chi-squared tests. RESULTS: A total of 148 people were included in the study, 74 in the patient group and 74 in the control group. Systolic and diastolic ABPs of patient group were statistically significantly lower than those of the control group (P < 0.001). P-wave width and amplitude in the patient group were significantly higher compared to the control group (P: 0.027 and P: 0.004, respectively). QRS width on patient group ECGs was significantly higher than in the control group, while T-wave amplitude was significantly lower (P: 0.045 and P < 0.001, respectively). ST elevation was seen in 12 (16.2%) subjects in the patient group, while no ST elevation was seen in the control group (P < 0.001). CONCLUSION: SCs can reduce systemic tension and SCs may cause changes in ECG, especially P wave, ST segment, T wave, and QRS. Further large-scale studies are needed to show whether these changes are associated with fatal arrhythmias or myocardial infarction.

20.
Medicine (Baltimore) ; 100(52): e28395, 2021 Dec 30.
Artigo em Inglês | MEDLINE | ID: mdl-34967374

RESUMO

ABSTRACT: In the last decade, high-resolution esophageal manometry (HREM) is the main device for the management of dysphagia replacing conventional manometry (CM). Conventional manometry still seems to have some space to diagnose major motility disorders and differentiate normal from abnormal esophageal motility. The long term outcomes of patients with normal CM were analyzed in our study.Participants (patients with dysphagia and normal CM) took a questionnaire via a phone call in February 2021. Impact Dysphagia Questionnaire (IDQ) was used as an assessment tool.Only 55% (83/151) the individuals with previous normal manometric findings were reached via telephone. The group who have completed the survey was representative of the cohort. 66.2% of the participants were female (P = .40). The mean age was 57.21, mean weight was 70.69 kg, mean height was 163.74 cm and mean body mass index was 26.41. More than 40% of patients were completely asymptomatic at follow up, reflected by an IDQ score of 0. Only 28 out of 83 (33.7%) patients reported significant symptoms as reflected by an IDQ score greater than or equal to 7. The rest of responders admitted as having moderate to mild symptoms.HREM is a valid technique with comparable precision to CM. HREM measurements differ considerably to CM. The identification of normal motor function in CM is not likely a positive prognostic indicator and must be interpreted precautiously.


Assuntos
Transtornos da Motilidade Esofágica , Manometria , Transtornos de Deglutição/diagnóstico , Transtornos de Deglutição/etiologia , Transtornos da Motilidade Esofágica/diagnóstico , Feminino , Humanos , Masculino , Manometria/métodos , Pessoa de Meia-Idade , Inquéritos e Questionários
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa