Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31
Filtrar
1.
Int J Hyperthermia ; 38(1): 1333-1340, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34477028

RESUMO

PURPOSE: Concurrent chemoradiotherapy (CCRT) is recommended as the standard treatment for locally advanced cervical cancer (LACC). However, the synergistic effect of hyperthermia (HT) with CCRT remains unclear. Therefore, we performed a meta-analysis to evaluate the effect of HT with CCRT on LACC patients. METHODS AND MATERIALS: A systematic literature search was conducted on the MEDLINE, PubMed, Embase, Cochrane library and SCOPUS databases for articles that compared CCRT with HT and CCRT alone as treatments for LACC. Hazard ratios (HRs) and risk ratios (RRs) were used to compare five-year overall survival (OS), local relapse-free survival (LRFS) and incidence of acute and chronic toxicity between the two treatments. RESULTS: Two articles out of 2860 were finally selected for analysis. A total of 536 patients were evaluated (CCRT with HT group: 268, CCRT group: 268). FIGO stages I-II and III-IV were found in 295 (55.0%) and 241 patients (45.0%), respectively. The CCRT with HT group had significantly better five-year OS than the CCRT group (HR 0.67, 95% confidence interval [CI] 0.47-0.96, p = 0.03). LRFS of patients was superior in the CCRT with HT group than in the CCRT group, but without significance (HR 0.74, 95% CI 0.49-1.12; p = 0.16). Moreover, there was no difference between the two groups regarding acute and chronic toxicity. CONCLUSION: This systematic review and meta-analysis showed that CCRT with HT significantly improved OS in LACC patients without increasing acute and chronic toxicity. Therefore, tri-modality treatment could be a feasible approach for patients with LACC.


Assuntos
Neoplasias do Colo do Útero , Quimiorradioterapia , Feminino , Humanos , Hipertermia , Recidiva Local de Neoplasia , Neoplasias do Colo do Útero/terapia
2.
Int J Clin Oncol ; 23(2): 287-297, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29134362

RESUMO

BACKGROUND: This study investigated the role of hyperthermia combined with preoperative concurrent chemoradiotherapy (CCRT) for locally advanced rectal cancer (LARC) according to hypoxic marker expression. METHODS: One hundred and nine LARC patients with tissue blocks available for immunohistochemical assessment of carbonic anhydrase 9 (CA9) expression were reviewed. CA9 expression was considered positive when the staining percentage of tumor cells was >25% (n = 31). Pelvic radiotherapy with a total dose of 39.6-45 Gy was delivered concurrently with fluorouracil-based chemotherapy. Hyperthermia was administered to 52 patients twice a week during CCRT. Treatment response and outcomes were compared between hyperthermochemoradiotherapy (HCRT) and CCRT groups. RESULTS: In patients with positive CA9 expression, the rates of downstaging (p = 0.060) and pathologic complete response (p = 0.064) tended to be higher in the HCRT group than in the CCRT group. Distant metastasis-free survival (p = 0.029) and cancer-specific survival (p = 0.020) were significantly worse in tumors with both positive CA9 expression and poor tumor response. Negative CA9 expression, presence of major tumor response, and the use of hyperthermia were significant favorable prognostic factors for cancer-specific survival after the first recurrence in multivariate analysis. CONCLUSIONS: Hyperthermia might selectively enhance the preoperative treatment response in LARC with positive CA9 expression and offset the negative effect of hypoxia on prognosis. Pretreatment evaluation of hypoxia could aid in the selection of patients who might benefit from hyperthermia.


Assuntos
Antígenos de Neoplasias/análise , Anidrase Carbônica IX/análise , Seleção de Pacientes , Neoplasias Retais/patologia , Neoplasias Retais/terapia , Idoso , Quimiorradioterapia/métodos , Terapia Combinada , Feminino , Fluoruracila/uso terapêutico , Humanos , Hipertermia Induzida/métodos , Masculino , Pessoa de Meia-Idade , Recidiva Local de Neoplasia , Cuidados Pré-Operatórios , Prognóstico , Neoplasias Retais/mortalidade , Taxa de Sobrevida , Falha de Tratamento , Resultado do Tratamento
3.
Support Care Cancer ; 24(10): 4399-406, 2016 10.
Artigo em Inglês | MEDLINE | ID: mdl-27220523

RESUMO

PURPOSE: This study compared a tablet PC questionnaire with a paper method for reliability and patient preferences in the acquisition of patient-reported outcomes (PROs) for patients treated with radiotherapy. By comparing the two modes of PRO administration, we aimed to evaluate the adequacy of using tablet PC questionnaires in future clinical use. METHODS: Patients were randomized in a crossover study design using two different methods for PRO entry. A group of 89 patients answered a paper questionnaire followed by the tablet PC version, whereas 89 patients in another group completed the tablet PC questionnaire followed by the paper version. Surveys were performed four times per patient throughout the course of the radiotherapy. The Korean versions of the M.D. Anderson Symptom Inventory (MDASI-K) and the Brief Fatigue Inventory (BFI-K) were used. The primary endpoint of our current study was an assessment of patient preference for the survey method. The proportions of patients preferring each mode of questionnaire were evaluated. RESULTS: The proportion of patients who preferred the tablet PC version, paper form, or who had no preference was 52.2, 22.1, and 25.7 %, respectively. More than half of the patients preferred the tablet PC to the paper version in all four surveys. Age, gender, educational status, prior experience of using a tablet PC, and the order of paper to tablet PC administration did not impact patient preferences. Inter-class correlation coefficients (ICCs) between the modes were 0.92 for MDASI-K and 0.94 for BFI-K and ranged from 0.91 to 0.96 on both instruments during the four surveys. CONCLUSIONS: A tablet PC-based PRO is an acceptable and reliable method compared with paper-based data collection for Korean patients receiving radiotherapy.


Assuntos
Internet/estatística & dados numéricos , Neoplasias/radioterapia , Qualidade de Vida/psicologia , Adolescente , Adulto , Idoso , Estudos Cross-Over , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Papel , Estudos Prospectivos , Inquéritos e Questionários , Adulto Jovem
4.
Breast Cancer Res Treat ; 146(2): 341-5, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24939061

RESUMO

To estimate the effect of boost radiotherapy on local recurrence-free survival (LRFS) in patients with ductal carcinoma in situ (DCIS) breast cancer. We included patients from nine institutions who met the following criteria: having Tis, age 18 years or older, having breast conserving surgery (BCS) and radiotherapy within 12 weeks after surgery. From 1995 through 2006, 728 patients were analyzed retrospectively by the Korean Radiation Oncology Group. All patients received whole-breast radiation therapy (WBRT) after BCS. 232 patients (31.9 %) also received boost radiation therapy (RT) (median 10 Gy). After median follow-up of 82 months, 5-year LRFS was 98.4 % and 10-year LRFS was 95.8 % for all patients. There was no statistically significant difference of LRFS between the boost and no-boost groups. Nineteen (2.6 %) patients had ipsilateral breast recurrences, including 12 of invasive recurrence and 7 DCIS. The presence of the HER2 receptor was associated with more invasive recurrences. Nine (1.2 %) patients developed contralateral breast cancer, including six invasive breast cancer and three DCIS. In the multivariate analysis, only the margin status was a significant prognostic factor for LRFS. Boost RT was not associated with further improvement of local control in DCIS after BCS and WBRT. HER2 receptor-positive patients may need further treatment with the anti-HER2 agents.


Assuntos
Neoplasias da Mama/patologia , Neoplasias da Mama/radioterapia , Carcinoma Intraductal não Infiltrante/patologia , Carcinoma Intraductal não Infiltrante/radioterapia , Neoplasias da Mama/mortalidade , Carcinoma Intraductal não Infiltrante/mortalidade , Feminino , Humanos , Gradação de Tumores , Recidiva Local de Neoplasia , Radioterapia Adjuvante , República da Coreia , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento
5.
Diagnostics (Basel) ; 14(4)2024 Feb 13.
Artigo em Inglês | MEDLINE | ID: mdl-38396449

RESUMO

HyperArc is a preferred technique for treating brain metastases, employing a single isocenter for multiple lesions. Geometrical isocentricity in the TrueBeam linear accelerator with HyperArc is crucial. We evaluated machine performance checks (MPCs) as an alternative to the Winston-Lutz (WL) test to verify the treatment isocenter. Between January and July 2023, we assessed 53 data points using MPC and Winston-Lutz tests. The isocenter size obtained from the MPC and its sum, including the rotation-induced couch shift, were compared with the maximum total delta value from the Winston-Lutz test. The maximum total delta was 0.68 ± 0.10 mm, while the isocenter size was 0.28 ± 0.02 mm. The sum of the isocenter size and rotation-induced couch shift measured by MPC was 0.61 ± 0.03 mm. During the Winston-Lutz test (without couch rotation), the maximum total delta value was 0.56 ± 0.13 mm. A t-test analysis revealed a significant difference in the isocenter size averages between the Winston-Lutz and MPC outcomes, whereas the Pearson's correlation coefficient yielded no correlation. Our study highlights the necessity for separate MPC and Winston-Lutz tests for isocenter verification. Therefore, the Winston-Lutz test should precede stereotactic radiosurgery for isocenter verification.

6.
PLoS One ; 17(8): e0271077, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35925916

RESUMO

Various applications of head-tilting techniques in whole-brain radiotherapy (WBRT) have been introduced. However, a study on the setup uncertainties and margins in head-tilting techniques has not been reported. This study evaluated the setup uncertainties and determined the appropriate planning target volume (PTV) margins for patients treated in the head-tilted supine (ht-SP) and conventional supine position (c-SP) in WBRT. Thirty patients who received WBRT at our institution between October 2020 and May 2021 in the c-SP and ht-SP were investigated. The DUON head mask (60124, Orfit Industries, Wijnegem, Belgium) was used in the c-SP, and a thermoplastic U-Frame Mask (R420U, Klarity Medical & Equipment Co. Ltd., Lan Yu, China) was used in the ht-SP. Daily setup verification using planning computed tomography (CT) and cone-beam CT was corrected for translational (lateral, longitudinal, and vertical) and rotational (yaw) errors. In the c-SP, the means of systematic errors were -0.80, 0.79, and 0.37 mm and random errors were 0.27, 0.54, and 0.39 mm in the lateral, longitudinal, and vertical translational dimensions, respectively. Whereas, for the ht-SP, the means of systematic errors were -0.07, 0.73, and -0.63 mm, and random errors were 0.75, 1.39, 1.02 mm in the lateral, longitudinal, and vertical translational dimensions, respectively. The PTV margins were calculated using Stroom et al.'s [2Σ+0.7σ] and van Herk et al.'s recipe [2.5Σ+0.7σ]. Appropriate PTV margins with van Herk et al.'s recipe in WBRT were <2 mm and 1.5° in the c-SP and <3 mm and 2° in the ht-SP in the translational and rotational directions, respectively. Although the head tilt in the supine position requires more margin, it can be applied as a sufficiently stable and effective position in radiotherapy.


Assuntos
Planejamento da Radioterapia Assistida por Computador , Radioterapia Guiada por Imagem , Encéfalo , Tomografia Computadorizada de Feixe Cônico/métodos , Humanos , Planejamento da Radioterapia Assistida por Computador/métodos , Erros de Configuração em Radioterapia/prevenção & controle , Radioterapia Guiada por Imagem/métodos , Decúbito Dorsal
7.
Healthcare (Basel) ; 10(9)2022 Sep 05.
Artigo em Inglês | MEDLINE | ID: mdl-36141313

RESUMO

The use of IT applications for patients undergoing radiotherapy is limited. This study aimed to develop an integrated system for communication between patients and radiation oncologists using IT technology and report the first test results for the system "Assisted Radiation Oncology Mobile Application" (AROMA). This system consisted of a manager program, a server running on a PC, and a mobile application on a smartphone. A prospective survey was conducted to evaluate the usefulness of this system from October 2020 to January 2021. The survey consisted of a specific questionnaire on basic information and application use by the patients. The management program was designed such that the user (doctor) edits the treatment schedule, member (patient and doctor) information, self-management, disease information, and side effect questionnaire. The mobile application for patients consisted of the current schedule, treatment schedule calendar, side effect questionnaire, side effect management method, and disease information entered by the doctor. A total of 41 patients were enrolled in this study. The mean adverse event response time was 4.4 days. In the survey, the mobile application received positive views (8.6/10 points). Most responses related to the side effect reporting function (94%) and communication using the application (91%) were positive. Satisfaction with the application design and each menu item was high, with an average of ≥8 and ≥8.5 points in most cases, respectively. The survey showed good satisfaction with the design, operability, and reporting system. Therefore, the system can facilitate communication between patients and radiation oncologists in the future.

8.
Cancers (Basel) ; 14(19)2022 Sep 26.
Artigo em Inglês | MEDLINE | ID: mdl-36230598

RESUMO

The bladder is subject to filling variation, which poses a challenge to radiotherapy (RT) delivery. We aimed to assess feasibility and clinical outcomes in patients with bladder cancer treated with adaptive RT (ART) using individualized plan libraries. We retrospectively analyzed 19 patients who underwent RT for muscle-invasive bladder cancer (MIBC) in 2015-2021. Four planning computed tomography (CT) scans were acquired at 15-min intervals, and a library of three intensity-modulated RT plans were generated using internal target volumes (ITVs). A post-treatment cone-beam CT (CBCT) scan was acquired daily to assess intra-fraction filling and coverage. All patients completed the treatment, with 408 post-treatment CBCT scans. The bladder was out of the planning target volume (PTV) range in 12 scans. The volumes of the evaluated PTV plans were significantly smaller than those of conventional PTV. The 1-year and 2-year overall survival rates were 88.2% and 63.7%, respectively. Of eight cases that experienced recurrence, only two developed MIBC. There were no grade 3 or higher RT-related adverse events. ART using plan libraries and ITVs demonstrated good survival outcomes with a high local control rate. Irradiated normal tissue volume and treatment margins may be reduced through this approach, potentially resulting in lower toxicity rates.

9.
Sci Rep ; 12(1): 17500, 2022 10 19.
Artigo em Inglês | MEDLINE | ID: mdl-36261615

RESUMO

This study aimed to fabricate a heterogeneous phantom replicating the commercial Rando phantom by mixing plaster powder and polylactic acid (PLA) powder. Producing a heterogeneous phantom using Plaster and PLA is cheaper because it can be easily obtained in the commercial market. Additionally, patient-specific Quality Assurance can be easily performed because the phantom can be produced based on the patient's CT image. PLA has been well studied in the field of radiation therapy and was found to be safe and effective. To match the mean Hounsfield unit (HU) values of the Rando phantom, the bone tissue was changed using plaster and 0-35% PLA powder until an appropriate HU value was obtained, and soft tissue was changed using the PLA infill value until an appropriate HU value was obtained. Bone tissue (200 HU or higher), soft issue (- 500 to 200 HU), and air cavity (less than - 500 HU) were modeled based on the HU values on the computed tomography (CT) image. The bone tissue was modeled as a cavity, and after three-dimensional (3D) printing, a solution containing a mixture of plaster and PLA powder was poured. To evaluate the bone implementation of the phantom obtained by the mixture of plaster and PLA powder, the HU profile of the CT images of the 3D-printed phantom using only PLA and the Rando phantom printed using only PLA was evaluated. The mean HU value for soft tissue in the Rando phantom (- 22.5 HU) showed the greatest similarity to the result obtained with an infill value of 82% (- 20 HU). The mean HU value for bone tissue (669 HU) showed the greatest similarity to the value obtained with 15% PLA powder (680 HU). Thus, for the phantom composed of plaster mixed with PLA powder, soft tissue was fabricated using a 3D printer with an infill value of 82%, and bone tissue was fabricated with a mixture containing 15% PLA powder. In the HU profile, this phantom showed a mean difference of 61 HU for soft tissue and 109 HU for bone tissue in comparison with the Rando phantom. The ratio of PLA powder and plaster can be adjusted to achieve an HU value similar to bone tissue. A simple combination of PLA powder and plaster enabled the creation of a custom phantom that showed similarities to the Rando phantom in both soft tissue and bone tissue.


Assuntos
Radioterapia de Intensidade Modulada , Humanos , Pós , Poliésteres , Impressão Tridimensional
10.
J Yeungnam Med Sci ; 39(2): 108-115, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34496467

RESUMO

BACKGRUOUND: This study was aimed at comparing and analyzing the results of FractionLab (Varian/Mobius Medical System) with those of portal dosimetry that uses an electronic portal imaging device. Portal dosimetry is extensively used for patient-specific quality assurance (QA) in intensity-modulated radiotherapy (IMRT). METHODS: The study includes 29 patients who underwent IMRT on a Novalis-Tx linear accelerator (Varian Medical System and BrainLAB) between June 2019 and March 2021. We analyzed the multileaf collimator (MLC) DynaLog files generated after portal dosimetry to evaluate the same condition using FractionLab. The results of the recently launched FractionLab at various gamma indices (0.1%/0.1 mm-1%/1 mm) are analyzed and compared with those of portal dosimetry (3%/3 mm). RESULTS: The average gamma passing rates of portal dosimetry (3%/3 mm) and FractionLab are 98.1 (95.5%-100%) and 97.5% (92.3%-99.7%) at 0.6%/0.6 mm, respectively. The results of portal dosimetry (3%/3 mm) are statistically comparable with the QA results of FractionLab (0.6%/0.6 mm-0.9%/0.9 mm). CONCLUSION: This paper presents the clinical performance of FractionLab by the comparison of the QA results of FractionLab using portal dosimetry with various gamma indexes when performing patient-specific QA in IMRT treatment. Further, the appropriate gamma index when performing patient-specific QA with FractionLab is provided.

11.
Cancers (Basel) ; 14(17)2022 Sep 02.
Artigo em Inglês | MEDLINE | ID: mdl-36077844

RESUMO

We aimed to determine the optimal pressure of continuous positive airway pressure (CPAP) for radiotherapy (RT) through changes in the dosimetric parameters and lung volume according to pressure. Patients with locally advanced lung cancer, who underwent CPAP during computed tomography (CT) simulation, were included. The air pressure was raised in five steps of 4, 7, 10, 14, and 17 cmH2O and a CT scan was performed at the baseline and at each pressure step, accompanied by contouring and RT planning. Paired t- and Wilcoxon signed rank tests were used to compare the volumetric and dosimetric parameters according to pressure and interpressure. A total of 29 patients were selected, and 158 CT datasets were obtained. The lung volume increased significantly at all pressures (p < 0.01). The Dmean of the lung decreased significantly from 7 cmH2O (p < 0.01), the V5, V10, V15, and V20 of the lung decreased significantly from 7 cmH2O with increasing pressure, and the Dmean and V5 of the heart decreased significantly from 14 cmH2O with increasing pressure. The V50 showed no significant differences at any pressure. We recommend the use of at least 7 cmH2O with 14 cmH2O as the optimal pressure to achieve the effect of heart preservation.

12.
Cancers (Basel) ; 14(17)2022 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-36077808

RESUMO

External beam radiotherapy is effective for stage I orbital mucosa-associated lymphoid tissue lymphoma (MALToma). Hence, very-low-dose radiotherapy is increasingly being investigated. We conducted a single-center prospective phase II trial to evaluate the effectiveness of very-low-dose radiotherapy of 4 Gy (2 Gy × 2 fractions) in pathologically confirmed stage I orbital MALToma. In this first prospective trial, patients with complete response were observed after 3-6 months of follow-up. For patients without complete remission, a radiation dose of 24 Gy/12 fractions was additionally delivered. The primary endpoint was complete response rate; secondary endpoints were overall survival, local control, and progression-free survival. Seventeen patients were screened and three patients refused enrollment during October 2018-October 2021. Thus, 14 patients (17 eyes) were analyzed (median follow-up, 28.2 months). The overall response rate was 100% (complete remission: 11 lesions; partial remission: six lesions). In all lesions with residual disease, additional radiation therapy (dose: 24 Gy) was performed. One local failure was observed. Therefore, 4 Gy ultralow-dose radiation therapy for orbital MALToma was safely performed with a planned second-line treatment in patients without complete remission. This is the first prospective study to report the effectiveness of ultralow-dose radiotherapy of 4 Gy for stage I orbital MALToma treatment.

13.
Radiat Oncol ; 16(1): 219, 2021 Nov 14.
Artigo em Inglês | MEDLINE | ID: mdl-34775988

RESUMO

BACKGROUND: Neoadjuvant chemoradiotherapy (nCRT) followed by surgery is a standard treatment modality for locally-advanced esophageal cancer. However, patients who achieve clinical complete response (cCR) after nCRT have been reported to have better prognosis. Further, the role of surgery in these patients is controversial. Thus, this meta-analysis aimed to evaluate whether surgery is still useful in patients with cCR after nCRT. METHODS: We systematically reviewed the MEDLINE, PubMed, Embase, Cochrane library, and Scopus databases for studies on surgical efficacy in complete responders after concurrent chemoradiotherapy for esophageal cancer. The publication date was set to January 1, 2010-January 31, 2020. The hazard ratio (HR) and risk ratio were used to compare the 2-year overall survival (OS), disease-free survival (DFS), incidence of locoregional failure, distant metastasis, and treatment mortality between the nCRT and nCRT plus surgery groups. RESULTS: Six articles involving 609 patients were included. There was a significant benefit of nCRT for OS (HR = 0.80, 95% confidence interval [CI] 0.64-0.99, p = 0.04), but not for DFS (HR = 1.55, 95% CI 0.35-6.86, p = 0.56). The nCRT group tended to have lower mortality than the nCRT plus surgery group (risk ratio = 0.15, 95% CI 0.02-1.18, p = 0.07). CONCLUSION: Omitting surgery provides better OS in complete responders after nCRT. Adding surgery could increase the morbidity and mortality and decrease the quality of life. Thus, nCRT alone could be a feasible approach for patients with cCR.


Assuntos
Quimiorradioterapia Adjuvante/métodos , Neoplasias Esofágicas/terapia , Esofagectomia/estatística & dados numéricos , Terapia Neoadjuvante/métodos , Qualidade de Vida , Neoplasias Esofágicas/patologia , Humanos , Prognóstico , Taxa de Sobrevida
14.
PLoS One ; 16(5): e0252234, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34043724

RESUMO

The objective of this study was to analyze the difference in residual setup errors between 6D ExacTrac and 3D cone-beam computed tomography (CBCT) image-guided systems in spinal stereotactic body radiation therapy (SBRT). We investigated 76 patients with spinal tumors who received SBRT using Novalis Tx at our institution between January 2013 and September 2020. A Vac-lok (EZ-FIX®, Arlico Medical Company, South Korea) fixture and an assistive device, based on the region involved, were used to immobilize patients and to increase the inter-fractional setup reproducibility. The difference in the root mean square (RMS) between the 6D ExacTrac and 3D CBCT was -0.75 mm, 0.45 mm, 0.16 mm, and -0.03°; the RMS value was 1.31 mm, 1.06 mm, 0.87 mm, and 0.64°; and the standard deviation was 0.80 mm, 0.72 mm, 0.62 mm, and 0.44° for lateral, longitudinal, vertical, and yaw directions, respectively. The difference in the average RMS between ExacTrac and CBCT was <1.03 mm in the translation direction and <0.47° in the rotational direction; the results were statistically significant in the lateral, longitudinal, and vertical directions, but not in the yaw direction. Thus, it is necessary to verify the ExacTrac image according to the CBCT image.


Assuntos
Tomografia Computadorizada de Feixe Cônico/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Erros de Configuração em Radioterapia , Radioterapia Guiada por Imagem/métodos , Neoplasias da Coluna Vertebral , Adulto , Idoso , Idoso de 80 Anos ou mais , Vértebras Cervicais/diagnóstico por imagem , Feminino , Humanos , Vértebras Lombares/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Neoplasias da Coluna Vertebral/diagnóstico por imagem , Neoplasias da Coluna Vertebral/radioterapia , Vértebras Torácicas/diagnóstico por imagem
15.
PLoS One ; 16(9): e0257216, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34506581

RESUMO

We aimed to compare the volumetric-modulated arc therapy (VMAT) plans with or without multi-criteria optimization (MCO) on commercial treatment-planning systems (Eclipse, Varian Medical System, Palo Alto, CA, USA) for patients with prostate cancer. We selected 25 plans of patients with prostate cancer who were previously treated on the basis of a VMAT plan. All plans were imported into the Eclipse Treatment Planning System version 15.6, and re-calculation and re-optimization were performed. The MCO plan was then generated. The dosimetric quality of the plans was evaluated using dosimetric parameters and dose indices that account for target coverage and sparing of the organs at risk (OARs). We defined the rectum, bladder, and bilateral femoral heads. The VMAT-MCO plan offers an improvement of gross treatment volume coverage with increased minimal dose and reduced maximal dose. In the planning treatment volume, the Dmean and better gradient, homogeneity, and conformity indexes improved despite the increasing hot and cold spots. When implemented through the MCO plan, a steeper fall off the adjacent OARs in the overlap area was achieved to obtain lower dose parameters. MCO generated better sparing of the rectum and bladder through a tradeoff of the increasing dose to the bilateral femoral heads within the tolerable dose constraints. Compared with re-optimization and re-calculation, respectively, significant dose reductions were observed in the bladder (241 cGy and 254 cGy; p<0.001) and rectum (474 cGy and 604 cGy, p<0.001) with the MCO. Planning evaluation and dosimetric measurements showed that the VMAT-MCO plan using visualized navigation can provide sparing of OAR doses without compromising the target coverage in the same OAR dose constraints.


Assuntos
Neoplasias da Próstata/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
16.
Medicine (Baltimore) ; 99(42): e22721, 2020 Oct 16.
Artigo em Inglês | MEDLINE | ID: mdl-33080729

RESUMO

BACKGROUND: The standard treatment for diffuse intrinsic pontine glioma (DIPG) is radiotherapy, although conventional fractionated radiotherapy (CFRT) may not be in the best interest of the patient. Instead, hypofractionated radiotherapy (HFRT) may shorten the treatment period and reduce related costs for this treatment, which is typically palliative in nature. METHODS: This systematic review and meta-analysis evaluated survival outcomes among patients who received HFRT or CFRT for DIPG. The PubMed, Medline, EMBASE, Cochrane Central Register, and Scopus databases were searched to identify relevant studies. Overall survival was the primary outcome of interest and progression-free survival was the secondary outcome of interest. RESULTS: The search identified a total of 2376 reports, although only 4 reports were ultimately included in the meta-analysis. The studies included 88 patients who underwent HFRT and 96 patients who underwent CFRT. Relative to CFRT, HFRT provided comparable outcomes in terms of overall survival (hazard ratio [HR]: 1.07, 95% confidence interval [CI]: 0.77-1.47) and progression-free survival (HR: 1.04, 95% CI: 0.75-1.45). CONCLUSIONS: The results of this meta-analysis suggest that CFRT and HFRT provide similar survival outcomes for patients with DIPG.


Assuntos
Neoplasias do Tronco Encefálico/radioterapia , Glioma Pontino Intrínseco Difuso/radioterapia , Humanos , Hipofracionamento da Dose de Radiação
17.
PLoS One ; 15(4): e0232430, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32348379

RESUMO

PURPOSE: Coplanar arcs are used with limited arc range to prevent direct beam entrance through the lens, which is challenging for satisfactory planning of hippocampal sparing in whole brain radiotherapy (HS-WBRT) with VMAT. We evaluated the dosimetric impact of applying a head-tilting technique during VMAT, which allows unrestricted use of the arc range. METHODS AND MATERIALS: Twenty patients with multiple brain metastases who had received two computed tomography (CT)-simulation sessions between January 2016 and December 2018 were included. One session was delivered in a traditional supine position; the other was delivered with a tilting acrylic supine baseplate (MedTec, USA) to elevate the patients' head by 40°. For each patient, a VMAT without (sVMAT) and with head-tilting (htVMAT) plan was generated. Conformity index (CI), homogeneity index (HI), and organ at risk (OAR) dose were evaluated. The Wilcoxon-signed test was used to compare the effect between two plans. RESULTS: The mean CI was 0.860±0.007 and 0.864±0.008 (p<0.05), and mean HI was 0.179±0.020 and 0.167±0.021 (p<0.05) for sVMAT and htVMAT, respectively. The mean dose to the hippocampus (9.91±0.30 Gy) was significantly lower in htVMAT than in sVMAT (10.36±0.29 Gy, P<0.05). htVMAT was associated with significantly reduced mean dose to the parotid gland, and right and left lens (4.77±1.97 Gy vs. 5.92±1.68 Gy, p<0.05; 3.29±0.44 Gy vs. 7.22±1.26 Gy, p<0.05; 3.33±0.45 Gy vs. 6.73±1.01 Gy, p<0.05, respectively). CONCLUSION: This is the first study to demonstrate that the head-tilting technique might be useful for HS-WBRT planning with VMAT. This method could remove the limitations associated with the arc range, resulting in improved dose distribution and conformity, while sparing healthy organs, including the hippocampus, lens, and parotid gland.


Assuntos
Neoplasias Encefálicas/radioterapia , Radioterapia de Intensidade Modulada/métodos , Idoso , Idoso de 80 Anos ou mais , Encéfalo/efeitos da radiação , Neoplasias Encefálicas/secundário , Feminino , Hipocampo/efeitos da radiação , Humanos , Masculino , Pessoa de Meia-Idade
18.
Radiat Oncol J ; 37(1): 22-29, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30947477

RESUMO

PURPOSE: The aim of this study is to evaluate the efficacy and feasibility of four-field box whole brain radiotherapy (FB-WBRT) with tilting baseplate by comparing bilateral WBRT (B-WBRT). METHODS AND MATERIALS: Between March 2016 and September 2018, 20 patients with brain metastases underwent WBRT using the four-field box technique. WBRT is performed with a dose of 30 Gy in 10 fractions daily. Two computed tomography simulations per person were performed. One was in the traditional supine position for B-WBRT and the other by applying the tilting acrylic supine baseplate to elevate the head by 40° for FB-WBRT. The B-WBRT used the field-in-field technique, which is the most commonly used method in our institution. The FB-WBRT comprised anterior, posterior, and bilateral beams. A wedge was applied in anterior and posterior fields to compensate for skull convexity. RESULTS: The average of Dmean of both parotid glands was 10.2 Gy (range, 3.8 to 17.8 Gy) in B-WBRT and 5.4 Gy (range, 2.0 to 11.7 Gy) in FB-WBRT (p < 0.05). Compared to B-WBRT, FB-WBRT reduced the mean dose of the right and left parotid glands from 10.1 Gy to 4.9 Gy and from 10.4 Gy to 5.8 Gy, respectively (p < 0.05). Further, V5, V10, V15, V20, and V25 for the parotid gland decreased significantly in FB-WBRT (p < 0.05). The Dmax and Dmean of lens decreased according to the dose-volume histogram. CONCLUSION: Compared to B-WBRT, FB-WBRT with a tilting baseplate is a simple and effective method that takes feature of noncoplanar beam to protect the parotid gland.

19.
Yeungnam Univ J Med ; 36(1): 36-42, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-31620610

RESUMO

Background: The purpose of this study was to evaluate the efficacy and feasibility of non-coplanar whole brain radiotherapy (NC-WBRT) for parotid sparing. Methods: Fifteen cases, previously treated with WBRT were selected. NC-WBRT plans were generated. The beam arrangement for the non-coplanar plans consisted of superior anterior, right, and left beams. After generation of the non-coplanar plans a field-in-field technique was applied to the bilateral parallel opposed beams in order to reduce maximum dose and increase dose homogeneity. The NC-WBRT plans were subsequently compared with the previously generated bilateral WBRT (B-WBRT) plans. A field-in-field technique was also used with the B-WBRT plans according to our departmental protocol. As per our institutional practice a total dose of 30 Gy in 10 fractions of WBRT was administered 5 days a week. Results: The mean dose to the parotid gland for the two different plans were 16.2 Gy with B-WBRT and 13.7 Gy with NC-WBRT (p<0.05). In the NC-WBRT plan, the V5Gy, V10Gy, V15Gy, V20Gy, and V25Gy of the parotid were significantly lower (p<0.05) than those of the B-WBRT plan. The Dmax of the lens was also lower by 10% with NC-WBRT. Conclusion: The use of NC-WBRT plans could be a simple and effective method to reduce irradiated volumes and improve the dose-volume parameters of the parotid gland.

20.
PLoS One ; 14(5): e0216655, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31095583

RESUMO

This study aimed to prospectively investigate the association between body weight (ΔBW) or body volume variations (ΔBV) and inter- or intra-fractional variations (Δ(inter) or Δ(intra)) in patients with head and neck cancer (HNC) undergoing radiotherapy (RT). This study enrolled patients with HNC from December 2015 to December 2017. All patients underwent curative intensity-modulated RT (IMRT) either as definitive or adjuvant treatment. Six-dimensional inter- and intra-fractional variations (Δ(inter) and Δ(intra)) were obtained with ExacTrac (BrainLAB, Feldkirchen, Germany) system. BV was measured 7.5 cm cranio-caudally from the centre using cone beam computed tomography. The BW, BV, and Δ(inter) were calculated based on the value obtained on the first treatment day after each simulation. Both Δ(inter) and Δ(intra) were considered in calculating the optimal margins for planning target volume (PTV), which was calculated using van Herk's formula. In total, 678 fractions with 39 simulations in 22 patients were analysed. The average ΔBW and ΔBV was -0.43±1.90 kg (range, -7.3 to 5.0) and -24.34±69.0 cc (range, -247.15 to 214.88), respectively. In correlation analysis, Δ(intra) was more associated with ΔBW or ΔBV than Δ(inter). Receiver operating characteristic analysis showed Δ(intra) could differentiate ΔBW from ΔBV, while Δ(inter) could not. The optimal margins for PTV considering both Δ(inter) and Δ(intra) were 3.70 mm, 4.52 mm, and 5.12 mm for the right-left, superior-inferior, and anterior-posterior directions, respectively. In conclusion, the PTV margin of 6 mm for anterior-posterior direction and 5 mm for the other directions were needed. ΔBW or ΔBV correlated with Δ(intra) rather than Δ(inter). Therefore, ΔBW or ΔBV should be assessed for accurate IMRT in patients with HNC.


Assuntos
Peso Corporal , Fracionamento da Dose de Radiação , Neoplasias de Cabeça e Pescoço/radioterapia , Radioterapia de Intensidade Modulada , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Curva ROC , Planejamento da Radioterapia Assistida por Computador
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa