Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 117
Filtrar
1.
Small ; 18(8): e2106823, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-35023629

RESUMO

Stem cell fate can be directed through the application of various external physical stimuli, enabling a controlled approach to targeted differentiation. Studies involving the use of dynamic mechanical cues driven by vibrational excitation to date have, however, been limited to low frequency (Hz to kHz) forcing over extended durations (typically continuous treatment for >7 days). Contrary to previous assertions that there is little benefit in applying frequencies beyond 1 kHz, we show here that high frequency MHz-order mechanostimulation in the form of nanoscale amplitude surface reflected bulk waves are capable of triggering differentiation of human mesenchymal stem cells from various donor sources toward an osteoblast lineage, with early, short time stimuli inducing long-term osteogenic commitment. More specifically, rapid treatments (10 min daily over 5 days) of the high frequency (10 MHz) mechanostimulation are shown to trigger significant upregulation in early osteogenic markers (RUNX2, COL1A1) and sustained increase in late markers (osteocalcin, osteopontin) through a mechanistic pathway involving piezo channel activation and Rho-associated protein kinase signaling. Given the miniaturizability and low cost of the devices, the possibility for upscaling the platform toward practical bioreactors, to address a pressing need for more efficient stem cell differentiation technologies in the pursuit of translatable regenerative medicine strategies, is ensivaged.


Assuntos
Células-Tronco Mesenquimais , Osteogênese , Diferenciação Celular/fisiologia , Células Cultivadas , Humanos , Osteoblastos , Osteogênese/fisiologia , Medicina Regenerativa
2.
Anal Chem ; 93(48): 16133-16141, 2021 12 07.
Artigo em Inglês | MEDLINE | ID: mdl-34813284

RESUMO

Diamond nitrogen-vacancy (NV) centers constitute a promising class of quantum nanosensors owing to the unique magneto-optic properties associated with their spin states. The large surface area and photostability of diamond nanoparticles, together with their relatively low synthesis costs, make them a suitable platform for the detection of biologically relevant quantities such as paramagnetic ions and molecules in solution. Nevertheless, their sensing performance in solution is often hampered by poor signal-to-noise ratios and long acquisition times due to distribution inhomogeneities throughout the analyte sample. By concentrating the diamond nanoparticles through an intense microcentrifugation effect in an acoustomicrofluidic device, we show that the resultant dense NV ensembles within the diamond nanoparticles give rise to an order-of-magnitude improvement in the measured acquisition time. The ability to concentrate nanoparticles under surface acoustic wave (SAW) microcentrifugation in a sessile droplet is, in itself, surprising given the well-documented challenge of achieving such an effect for particles below 1 µm in dimension. In addition to a demonstration of their sensing performance, we thus reveal in this work that the reason why the diamond nanoparticles readily concentrate under the SAW-driven recirculatory flow can be attributed to their considerably higher density and hence larger acoustic contrast compared to those for typical particles and cells for which the SAW microcentrifugation flow has been shown to date.


Assuntos
Nanodiamantes , Corantes , Íons , Nitrogênio
3.
Anal Chem ; 92(14): 10024-10032, 2020 07 21.
Artigo em Inglês | MEDLINE | ID: mdl-32475111

RESUMO

Preconcentrating particulate and cellular matter for their isolation or detection is often a necessary and critical sample preparation or purification step in many lab-on-a-chip diagnostic devices. While surface acoustic wave (SAW) microcentrifugation has been demonstrated as a powerful means to drive efficient particle concentration, this has primarily been limited to micron dimension particles. When the particle size is around 1 µm or below, studies on SAW microcentrifugation to date have shown that particle ring-like aggregates can only be obtained in contrast to the localized concentrated clusters that are obtained with larger particles. Considering the importance of submicron particles and bioparticles that are common in many real-world samples, we elucidate why previous studies have not been able to achieve the concentration of these smaller particles to completion, and we present a practical solution involving a novel closed chamber configuration that minimizes sample heating and eliminates evaporation to show that it is indeed possible to drive submicron particle and cell concentration down to 200 nm diameters with SAW microcentrifugation over longer durations.


Assuntos
Centrifugação , Mycoplasma hominis/citologia , Som , Imagem Óptica , Tamanho da Partícula , Propriedades de Superfície
4.
Small ; 16(9): e1903605, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31535785

RESUMO

Microcentrifugation constitutes an important part of the microfluidic toolkit in a similar way that centrifugation is crucial to many macroscopic procedures, given that micromixing, sample preconcentration, particle separation, component fractionation, and cell agglomeration are essential operations in small scale processes. Yet, the dominance of capillary and viscous effects, which typically tend to retard flow, over inertial and gravitational forces, which are often useful for actuating flows and hence centrifugation, at microscopic scales makes it difficult to generate rotational flows at these dimensions, let alone with sufficient vorticity to support efficient mixing, separation, concentration, or aggregation. Herein, the various technologies-both passive and active-that have been developed to date for vortex generation in microfluidic devices are reviewed. Various advantages or limitations associated with each are outlined, in addition to highlighting the challenges that need to be overcome for their incorporation into integrated microfluidic devices.

5.
Proc Natl Acad Sci U S A ; 114(39): 10332-10337, 2017 09 26.
Artigo em Inglês | MEDLINE | ID: mdl-28894002

RESUMO

We report the self-organization of universal branching patterns of oil nanodroplets under the Ouzo effect [Vitale S, Katz J (2003) Langmuir 19:4105-4110]-a phenomenon in which spontaneous droplet formation occurs upon dilution of an organic solution of oil with water. The mixing of the organic and aqueous phases is confined under a quasi-2D geometry. In a manner analogous to the ramification of ground stream networks [Devauchelle O, Petroff AP, Seybold HF, Rothman DH (2012) Proc Natl Acad Sci USA 109: 20832-20836 and Cohen Y, et al. (2015) Proc Natl Acad Sci USA 112:14132-14137] but on a scale 10 orders of magnitude smaller, the angles between the droplet branches are seen to exhibit remarkable universality, with a value around 74° ± 2°, independent of the various control parameters of the process. Numerical simulations reveal that these nanodroplet branching patterns are governed by the interplay between the local concentration gradient, diffusion, and collective interactions. We further demonstrate the ability of the local concentration gradient to drive autonomous motion of colloidal particles in the highly confined space, and the possibility of using the nucleated nanodroplets for nanoextraction of a hydrophobic solute. The understanding obtained from this work provides a basis for quantitatively understanding the complex dynamical aspects associated with the Ouzo effect. We expect that this will facilitate improved control in nanodroplet formation for many applications, spanning from the preparation of pharmaceutical polymeric carriers, to the formulation of cosmetics and insecticides, to the fabrication of nanostructured materials, to the concentration and separation of trace analytes in liquid-liquid microextraction.

6.
Anal Chem ; 91(19): 12358-12368, 2019 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-31500406

RESUMO

Rayleigh surface acoustic waves (SAWs) have been demonstrated as a powerful and effective means for driving a wide range of microfluidic actuation processes. Traditionally, SAWs have been generated on piezoelectric substrates, although the cost of the material and the electrode deposition process makes them less amenable as low-cost and disposable components. As such, a "razor-and-blades" model that couples the acoustic energy of the SAW on the piezoelectric substrate through a fluid coupling layer and into a low-cost and, hence, disposable silicon superstrate on which various microfluidic processes can be conducted has been proposed. Nevertheless, it was shown that only bulk vibration in the form of Lamb waves can be excited in the superstrate, which is considerably less efficient and flexible in terms of microfluidic functionality compared to its surface counterpart, that is, the SAW. Here, we reveal an extremely simple way that quite unexpectedly and rather nonintuitively allows SAWs to be generated on the superstrate-by coating the superstrate with a thin gold layer. In addition to verifying the existence of the SAW on the coated superstrate, we carry out finite-difference time domain numerical simulations that not only confirm the experimental observations but also facilitate an understanding of the surprising difference that the coating makes. Finally, we elucidate the various power-dependent particle concentration phenomena that can be carried out in a sessile droplet atop the superstrate and show the possibility for simply carrying out rapid and effective microcentrifugation-a process that is considerably more difficult with Lamb wave excitation on the superstrate.

7.
Anal Chem ; 91(9): 5621-5628, 2019 05 07.
Artigo em Inglês | MEDLINE | ID: mdl-30915842

RESUMO

We seek to demonstrate a robust, low-cost, and user-friendly acoustomicrofluidic platform that facilitates rapid, reproducible, and precise nanoliter sample dispensing. The solid-state chipscale platform exploits the unprecedented acceleration arising from high-frequency nanoelectromechanical vibrations, on the order of 10 million g, to jet the sample and hence generate a liquid bridge that spans across the substrate, on which the vibrations are generated and from which the sample originates, to a top target plate before rapidly pinching off to deposit the sample on the target with precise and reproducible volumes that can be tuned down to 0.22 µL with a standard error of 6.5% and coefficient of variation of 11.3%. The entire process occurs within approximately 10 ms. In addition to explicating the fundamental physical mechanism that underpins the technology, we demonstrate its use for serial dilution and concentration and, in particular, a cell-based drug toxicology assay. Moreover, we also show that multiple drop dispensing in an array, without requiring repositioning of the chip between dispensing steps, can be achieved through a simple but yet effective sequential directional jetting strategy, therefore allowing significant reduction in the total dispensing time in the case of massive-scale microarray operation. Given its low cost and compact size, the platform can easily be automated and parallelized, thus offering the prospect for introducing large-scale efficiencies in the laboratory workflow.

8.
Soft Matter ; 15(20): 4146-4152, 2019 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-31050347

RESUMO

Tactile haptic feedback is an important consideration in the design of advanced human-machine interfaces, particularly in an age of increasing reliance on automation and artificial intelligence. In this work, we show that the typical nanometer-order surface displacement amplitudes of piezoelectric transducers-which are too small to be detectable by the human touch, and constitute a significant constraint in their use for tactile haptic surface actuation-can be circumvented by coupling the vibration into a liquid to drive the deflection of a thermoplastic membrane. In particular, transmission of the sound energy from the standing wave vibration generated along a piezoelectric transducer into a microfluidic chamber atop which the membrane is attached is observed to amplify the mechanical vibration signalling through both the acoustic radiation pressure and the viscous normal stress acting on the membrane-the latter arising due to the acoustic streaming generated as the sound wave propagates through the liquid-to produce 100 µm-order static deflections of the membrane, upon which approximately 0.5 µm dynamic vibrations at frequencies around 1 kHz are superimposed; both these static and dynamic responses are within the perception range for human finger sensation. The large static deformation, the relatively fast response time, and the ability to incorporate a dynamic vibrotactile response together with the small size and potential for integration of the device into large scale arrays make this mechanism well suited for driving actuation in devices which require tactile haptic responses.

9.
Anal Chem ; 90(8): 5335-5342, 2018 04 17.
Artigo em Inglês | MEDLINE | ID: mdl-29624368

RESUMO

While many microfluidic devices have been developed for sensing and others for actuation, few devices can perform both tasks effectively and simultaneously on the same platform. In piezoelectric sensors and actuators, this is due to the opposing operating requirements for sensing and actuation. Sensing ideally requires narrow resonant peaks characterized by high quality factors, such as those found in quartz crystals. However, these materials usually have poor electromechanical coupling coefficients that are not ideal for actuation. In this work, we show that it is possible to achieve both sensing and actuation simultaneously on a shared device by exploiting the distinct advantages of both bulk waves for effective mass sensing and surface waves for highly efficient microfluidic actuation through a unique hybrid surface and bulk acoustic wave platform. In light of the recent resurgence of interest in portable inhaled insulin devices for personalized diabetes management, we demonstrate the use of this technology for efficient aerosolization of insulin for inhalation without denaturing the protein, while being able to concurrently detect the residual mass of the un-nebulized insulin remaining on the device such that the actual dose delivered to the patient can be determined in real time.

10.
Biomed Microdevices ; 20(4): 95, 2018 11 06.
Artigo em Inglês | MEDLINE | ID: mdl-30402766

RESUMO

Cell contact formation, which is the process by which cells are brought into close proximity is an important biotechnological process in cell and molecular biology. Such manipulation is achieved by various means, among which dielectrophoresis (DEP) is widely used due to its simplicity. Here, we show the advantages in the judicious choice of the DEP microelectrode configuration in terms of limiting undesirable effects of dielectric heating on the cells, which could lead to their inactivation or death, as well as the possibility for cell clustering, which is particularly advantageous over the linear cell chain arrangement typically achieved to date with DEP. This study comprises of experimental work as well as mathematical modeling using COMSOL. In particular, we establish the parameters in a capillary-based microfluidic system giving rise to these optimum cell-cell contact configurations, together with the possibility for facilitating other cell manipulations such as spinning and rotation, thus providing useful protocols for application into microfluidic bioparticle manipulation systems for diagnostics, therapeutics or for furthering research in cellular bioelectricity and intercellular interactions.


Assuntos
Técnicas Citológicas/instrumentação , Eletroforese/instrumentação , Dispositivos Lab-On-A-Chip , Sobrevivência Celular , Impedância Elétrica , Eletrodos , Desenho de Equipamento , Temperatura Alta , Leveduras/citologia
11.
Soft Matter ; 14(28): 5721-5727, 2018 Jul 18.
Artigo em Inglês | MEDLINE | ID: mdl-29845144

RESUMO

We report a miniaturised platform for continuous production of single or multiple liquid droplets with diameters between 60 and 500 µm by interfacing a capillary-driven self-replenishing liquid feed with pulsed excitation of focussed surface acoustic waves (SAWs). The orifice-free operation circumvents the disadvantages of conventional jetting systems, which are often prone to clogging that eventuates in rapid degradation of the operational performance. Additionally, we show the possibility for flexibly tuning the ejected droplet size through the pulse width duration, thus avoiding the need for a separate device for every different droplet size required, as is the case for systems in which the droplet size is set by nozzles and orifices, as well as preceding ultrasonic jetting platforms where the droplet size is controlled by the operating frequency. Further, we demonstrate that cells can be jetted and hence printed onto substrates with control over the cell density within the droplets down to single cells. Given that the jetting does not lead to significant loss to the cell's viability or ability to proliferate, we envisage that this versatile jetting method can potentially be exploited with further development for cell encapsulation, dispensing and 3D bioprinting applications.

12.
Soft Matter ; 14(28): 5937-5938, 2018 Jul 18.
Artigo em Inglês | MEDLINE | ID: mdl-29926038

RESUMO

Correction for 'Continuous tuneable droplet ejection via pulsed surface acoustic wave jetting' by Jasmine O. Castro et al., Soft Matter, 2018, DOI: 10.1039/c7sm02534c.

13.
Nano Lett ; 16(2): 849-55, 2016 Feb 10.
Artigo em Inglês | MEDLINE | ID: mdl-26729449

RESUMO

By exploiting the very recent discovery of the piezoelectricity in odd-numbered layers of two-dimensional molybdenum disulfide (MoS2), we show the possibility of reversibly tuning the photoluminescence of single and odd-numbered multilayered MoS2 using high frequency sound wave coupling. We observe a strong quenching in the photoluminescence associated with the dissociation and spatial separation of electrons-holes quasi-particles at low applied acoustic powers. At the same applied powers, we note a relative preference for ionization of trions into excitons. This work also constitutes the first visual presentation of the surface displacement in one-layered MoS2 using laser Doppler vibrometry. Such observations are associated with the acoustically generated electric field arising from the piezoelectric nature of MoS2 for odd-numbered layers. At larger applied powers, the thermal effect dominates the behavior of the two-dimensional flakes. Altogether, the work reveals several key fundamentals governing acousto-optic properties of odd-layered MoS2 that can be implemented in future optical and electronic systems.

14.
Soft Matter ; 11(41): 8076-82, 2015 Nov 07.
Artigo em Inglês | MEDLINE | ID: mdl-26333170

RESUMO

Suspensions of copper nanowires are emerging as new electronic inks for next-generation flexible electronics. Using a novel surface acoustic wave driven extensional flow technique we are able to perform currently lacking analysis of these suspensions and their complex buffer. We observe extensional viscosities from 3 mPa s (1 mPa s shear viscosity) to 37.2 Pa s via changes in the suspension concentration, thus capturing low viscosities that have been historically very challenging to measure. These changes equate to an increase in the relative extensional viscosity of nearly 12,200 times at a volume fraction of just 0.027. We also find that interactions between the wires and the necessary polymer additive affect the rheology strongly. Polymer-induced elasticity shows a reduction as the buffer relaxation time falls from 819 to 59 µs above a critical particle concentration. The results and technique presented here should aid in the future formulation of these promising nanowire suspensions and their efficient application as inks and coatings.

15.
Soft Matter ; 11(23): 4658-68, 2015 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-25969844

RESUMO

Suspensions of motile cells are model systems for understanding the unique mechanical properties of living materials which often consist of ensembles of self-propelled particles. We present here a quantitative comparison of theory against experiment for the rheology of such suspensions in extensional flows. The influence of motility on viscosities of cell suspensions is studied using a novel acoustically-driven microfluidic capillary-breakup extensional rheometer. Motility increases the extensional viscosity of suspensions of algal pullers, but decreases it in the case of bacterial or sperm pushers. A recent model [Saintillan, Phys. Rev. E: Stat., Nonlinear, Soft Matter Phys., 2010, 81, 56307] for dilute active suspensions is extended to obtain predictions for higher concentrations, after independently obtaining parameters such as swimming speeds and diffusivities. We show that details of body and flagellar shape can significantly determine macroscale rheological behaviour.


Assuntos
Bactérias/metabolismo , Flagelos/metabolismo , Modelos Biológicos , Viscosidade
16.
Anal Chem ; 86(21): 10812-9, 2014 Nov 04.
Artigo em Inglês | MEDLINE | ID: mdl-25275830

RESUMO

Conventional flow injection systems for aquatic environmental analysis typically comprise large laboratory benchscale equipment, which place considerable constraints for portable field use. Here, we demonstrate the use of an integrated acoustically driven microfluidic mixing scheme to enhance detection of a chemiluminescent species tris(2,2'-bipyridyl)dichlororuthenium(II) hexahydrate-a common chemiluminescent reagent widely used for the analysis of a wide range of compounds such as illicit drugs, pharmaceuticals, and pesticides-such that rapid in-line quantification can be carried out with sufficient on-chip sensitivity. Specifically, we employ surface acoustic waves (SAWs) to drive intense chaotic streaming within a 100 µL chamber cast in polydimethoxylsiloxane (PDMS) atop a microfluidic chip consisting of a single crystal piezoelectric material. By optimizing the power, duration, and orientation of the SAW input, we show that the mixing intensity of the sample and reagent fed into the chamber can be increased by one to two orders of magnitude, leading to a similar enhancement in the detection sensitivity of the chemiluminescent species and thus achieving a theoretical limit of detection of 0.02 ppb (0.2 nM) of l-proline-a decade improvement over the industry gold-standard and two orders of magnitude more sensitive than that achievable with conventional systems-simply using a portable photodetector and without requiring sample preconcentration. This on-chip microfluidic mixing strategy, together with the integrated miniature photodetector and the possibility for chip-scale microfluidic actuation, then alludes to the attractive possibility of a completely miniaturized platform for portable field-use microanalytical systems.

18.
Respir Res ; 15: 60, 2014 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-24884387

RESUMO

BACKGROUND: Pulmonary-delivered gene therapy promises to mitigate vaccine safety issues and reduce the need for needles and skilled personnel to use them. While plasmid DNA (pDNA) offers a rapid route to vaccine production without side effects or reliance on cold chain storage, its delivery to the lung has proved challenging. Conventional methods, including jet and ultrasonic nebulizers, fail to deliver large biomolecules like pDNA intact due to the shear and cavitational stresses present during nebulization. METHODS: In vitro structural analysis followed by in vivo protein expression studies served in assessing the integrity of the pDNA subjected to surface acoustic wave (SAW) nebulisation. In vivo immunization trials were then carried out in rats using SAW nebulized pDNA (influenza A, human hemagglutinin H1N1) condensate delivered via intratracheal instillation. Finally, in vivo pulmonary vaccinations using pDNA for influenza was nebulized and delivered via a respirator to sheep. RESULTS: The SAW nebulizer was effective at generating pDNA aerosols with sizes optimal for deep lung delivery. Successful gene expression was observed in mouse lung epithelial cells, when SAW-nebulized pDNA was delivered to male Swiss mice via intratracheal instillation. Effective systemic and mucosal antibody responses were found in rats via post-nebulized, condensed fluid instillation. Significantly, we demonstrated the suitability of the SAW nebulizer to administer unprotected pDNA encoding an influenza A virus surface glycoprotein to respirated sheep via aerosolized inhalation. CONCLUSION: Given the difficulty of inducing functional antibody responses for DNA vaccination in large animals, we report here the first instance of successful aerosolized inhalation delivery of a pDNA vaccine in a large animal model relevant to human lung development, structure, physiology, and disease, using a novel, low-power (<1 W) surface acoustic wave (SAW) hand-held nebulizer to produce droplets of pDNA with a size range suitable for delivery to the lower respiratory airways.


Assuntos
Técnicas de Transferência de Genes , Pulmão/fisiologia , Som , Vacinação/métodos , Vacinas de DNA/administração & dosagem , Vacinas de DNA/genética , Administração por Inalação , Aerossóis , Animais , Feminino , Humanos , Masculino , Camundongos , Nebulizadores e Vaporizadores , Ratos , Ratos Sprague-Dawley , Ovinos , Propriedades de Superfície , Resultado do Tratamento
19.
Langmuir ; 30(37): 11243-7, 2014 Sep 23.
Artigo em Inglês | MEDLINE | ID: mdl-25186138

RESUMO

Poloidal flow is curiously formed in a microliter sessile water drop over 157-225 MHz because of acoustic streaming from three-dimensional standing Lamb waves in a lithium niobate substrate. The flow possesses radial symmetry with downwelling at the center and upwelling around the periphery of the drop. Outside this frequency range, the attenuation occurs over a length scale incompatible with the drop size and the poloidal flow vanishes. Remarkably, shear-induced migration was found to drive toroidal particle ring formation with diameters inversely proportional to the frequency of the acoustic irradiation.

20.
Ultrasonics ; 138: 107234, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38171227

RESUMO

The development of alternative techniques to efficiently inactivate bacterial suspensions is crucial to prevent transmission of waterborne illness, particularly when commonly used techniques such as heating, filtration, chlorination, or ultraviolet treatment are not practical or feasible. We examine the effect of MHz-order acoustic wave irradiation in the form of surface acoustic waves (SAWs) on Gram-positive (Escherichia coli) and Gram-negative (Brevibacillus borstelensis and Staphylococcus aureus) bacteria suspended in water droplets. A significant increase in the relative bacterial load reduction of colony-forming units (up to 74%) can be achieved by either increasing (1) the excitation power, or, (2) the acoustic treatment duration, which we attributed to the effect of the acoustic radiation force exerted on the bacteria. Consequently, by increasing the maximum pressure amplitude via a hybrid modulation scheme involving a combination of amplitude and pulse-width modulation, we observe that the bacterial inactivation efficiency can be further increased by approximately 14%. By combining this scalable acoustic-based bacterial inactivation platform with plasma-activated water, a 100% reduction in E. coli is observed in less than 10 mins, therefore demonstrating the potential of the synergistic effects of MHz-order acoustic irradiation and plasma-activated water as an efficient strategy for water decontamination.


Assuntos
Bactérias , Escherichia coli , Bactérias/efeitos da radiação , Som , Acústica , Água
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa