Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 44
Filtrar
1.
Eur Radiol ; 2024 Feb 23.
Artigo em Inglês | MEDLINE | ID: mdl-38393403

RESUMO

OBJECTIVES: To investigate the clinical utility of fully-automated 3D organ segmentation in assessing hepatic steatosis on pre-contrast and post-contrast CT images using magnetic resonance spectroscopy (MRS)-proton density fat fraction (PDFF) as reference standard. MATERIALS AND METHODS: This retrospective study analyzed 362 adult potential living liver donors with abdominal CT scans and MRS-PDFF. Using a deep learning-based tool, mean volumetric CT attenuation of the liver and spleen were measured on pre-contrast (liver(L)_pre and spleen(S)_pre) and post-contrast (L_post and S_post) images. Agreements between volumetric and manual region-of-interest (ROI)-based measurements were assessed using the intraclass correlation coefficient (ICC) and Bland-Altman analysis. Diagnostic performances of volumetric parameters (L_pre, liver-minus-spleen (L-S)_pre, L_post, and L-S_post) were evaluated for detecting MRS-PDFF ≥ 5% and ≥ 10% using receiver operating characteristic (ROC) curve analysis and compared with those of ROI-based parameters. RESULTS: Among the 362 subjects, 105 and 35 had hepatic steatosis with MRS-PDFF ≥ 5% and ≥ 10%, respectively. Volumetric and ROI-based measurements revealed ICCs of 0.974, 0.825, 0.992, and 0.962, with mean differences of -4.2 HU, -3.4 HU, -1.2 HU, and -7.7 HU for L_pre, S_pre, L_post, and S_post, respectively. Volumetric L_pre, L-S_pre, L_post, and L-S_post yielded areas under the ROC curve of 0.813, 0.813, 0.734, and 0.817 for MRS-PDFF ≥ 5%; and 0.901, 0.915, 0.818, and 0.868 for MRS-PDFF ≥ 10%, comparable with those of ROI-based parameters (0.735-0.818; and 0.816-0.895, Ps = 0.228-0.911). CONCLUSION: Automated 3D segmentation of the liver and spleen in CT scans can provide volumetric CT attenuation-based parameters to detect and grade hepatic steatosis, applicable to pre-contrast and post-contrast images. CLINICAL RELEVANCE STATEMENT: Volumetric CT attenuation-based parameters of the liver and spleen, obtained through automated segmentation tools from pre-contrast or post-contrast CT scans, can efficiently detect and grade hepatic steatosis, making them applicable for large population data collection. KEY POINTS: • Automated organ segmentation enables the extraction of CT attenuation-based parameters for the target organ. • Volumetric liver and spleen CT attenuation-based parameters are highly accurate in hepatic steatosis assessment. • Automated CT measurements from pre- or post-contrast imaging show promise for hepatic steatosis screening in large cohorts.

2.
Eur Radiol ; 34(7): 4674-4685, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38114846

RESUMO

OBJECTIVES: To identify MRI features for differentiating type 2 from type 1 intraductal papillary neoplasms of bile duct (IPNB) and assessing malignant potential of IPNB. METHODS: This retrospective study included 60 patients with surgically proven IPNB who had undergone preoperative MRI between January 2007 and December 2020. All surgical specimens were reviewed retrospectively to classify types 1 and 2 IPNBs and assess tumor grade. Significant MRI features for differentiating type 2 (n = 40) from type 1 IPNB (n = 20); and for IPNB with an associated invasive carcinoma (n = 43) from intraepithelial neoplasia (n = 17) were determined using logistic regression analysis. RESULTS: An associated invasive carcinoma was more frequently found in type 2 than in type 1 IPNB (85.0% [34/40] vs. 45.0% [9/20], p = 0.003). At univariable analysis, MRI features including extrahepatic location, no dilatation of tumor-bearing segment of bile duct, isolated upstream bile duct dilatation, and single lesion were associated with type 2 IPNB (all p ≤ 0.012). At multivariable analysis, significant MRI findings for differentiating type 2 from type 1 IPNB were extrahepatic location and no dilatation of tumor-bearing segment of bile duct (odds ratio [OR], 7.24 and 46.40, respectively). At univariable and multivariable analysis, tumor size ≥ 2.5 cm (OR, 8.45), bile duct wall thickening (OR, 4.82), and irregular polypoid or nodular tumor shape (OR, 6.44) were significant MRI features for differentiating IPNB with an associated invasive carcinoma from IPNB with intraepithelial neoplasia. CONCLUSION: MRI with MR cholangiopancreatography may be helpful in differentiating type 2 IPNB from type 1 IPNB and assessing malignant potential of IPNB. CLINICAL RELEVANCE STATEMENT: Preoperative MRI with MR cholangiopancreatography may be helpful in differentiating type 2 intraductal papillary neoplasms of bile duct (IPNB) from type 1 IPNB and assessing malignant potential of IPNB. KEY POINTS: • In terms of tumor grade, the incidence of invasive carcinoma was significantly higher in type 2 intraductal papillary neoplasm of the bile duct (IPNB) than in type 1 IPNB. • At MRI, extrahepatic location and no dilatation of tumor-bearing segment are significant features for differentiating type 2 IPNBs from type 1 IPNBs. • At MRI, large tumor size, bile duct wall thickening, and irregular polypoid or nodular tumor shape are significant features for differentiating IPNB with an associated invasive carcinoma from IPNB with intraepithelial neoplasia.


Assuntos
Neoplasias dos Ductos Biliares , Imageamento por Ressonância Magnética , Humanos , Masculino , Feminino , Imageamento por Ressonância Magnética/métodos , Estudos Retrospectivos , Neoplasias dos Ductos Biliares/diagnóstico por imagem , Neoplasias dos Ductos Biliares/patologia , Pessoa de Meia-Idade , Idoso , Diagnóstico Diferencial , Adulto , Idoso de 80 Anos ou mais
3.
AJR Am J Roentgenol ; 222(2): e2330156, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-37991335

RESUMO

BACKGROUND. Contrast-enhanced ultrasound (CEUS) with perfluorobutane has used varying protocols and diagnostic criteria for hepatocellular carcinoma (HCC). OBJECTIVE. The purpose of this article was to assess diagnostic performance for HCC of CEUS with perfluorobutane in high-risk patients using various criteria. METHODS. This retrospective post hoc study evaluating individual patient data from three earlier prospective studies from one hospital included 204 patients (136 men, 68 women; mean age, 63 ± 11 [SD] years) at high risk of HCC with 213 liver observations. Patients underwent CEUS using perfluorobutane from March 2019 to June 2022. Three radiologists (the examination's operator and two subsequent reviewers) independently interpreted examinations, assessing arterial, portal venous (arterial phase completion through 2 minutes), transitional (2-5 minutes after injection), and Kupffer (≥ 10 minutes after injection) phase findings. Six criteria for HCC were tested: 1, any arterial phase hyperenhancement (APHE) with Kupffer phase hypoenhancement; 2, nonrim APHE with Kupffer phase hypoenhancement; 3, nonrim APHE with portal venous washout; 4, nonrim APHE with portal venous washout and/or Kupffer phase hypoenhancement; 5, nonrim APHE with portal venous and/or transitional washout; 6, nonrim APHE with any of portal venous washout, transitional washout, or Kupffer phase hypoenhancement. Depending on the criteria, observations were instead deemed to be a non-HCC malignancy if showing rim APHE, early washout (at < 1 minute), or marked washout (at 2 minutes). Reference was pathology for malignant observations and pathology or imaging follow-up for benign observations. Diagnostic performance was assessed, pooling readers' data. RESULTS. Criterion 1 (no recognized features of non-HCC malignancy) had highest sensitivity (86.9%) but lowest specificity (43.2%) for HCC. Compared with nonrim APHE and portal venous washout (criterion 3), the addition of Kupffer phase hypoenhancement (criterion 4), transitional washout (criterion 5), or either feature (criterion 6) significantly increased sensitivity (34.4% vs 62.6-64.2%) and accuracy (61.8% vs 75.1-76.5%), but significantly decreased specificity (98.5% vs 91.9-94.1%). Criteria 2, 4, 5, and 6 (all incorporating transitional washout and/or Kupffer phase hypoenhancement) showed no significant differences in sensitivity (62.6-64.2%), specificity (91.9-94.1%), or accuracy (75.1-76.5%). CONCLUSION. Recognition of features of non-HCC malignancy improved specificity for HCC. Incorporation of the findings of transitional washout and/or Kupffer phase hypoenhancement improved sensitivity and accuracy, albeit lowered specificity, versus arterial and portal venous findings alone, without further performance variation among criteria incorporating those two findings. CLINICAL IMPACT. Kupffer phase acquisition may be optional for observations classified as HCC or non-HCC malignancy by arterial, portal venous, and transitional phases.


Assuntos
Carcinoma Hepatocelular , Fluorocarbonos , Neoplasias Hepáticas , Masculino , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/patologia , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/patologia , Estudos Retrospectivos , Estudos Prospectivos , Meios de Contraste , Imageamento por Ressonância Magnética/métodos , Sensibilidade e Especificidade , Ultrassonografia/métodos
4.
Radiol Med ; 2024 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-38869829

RESUMO

PURPOSE: To evaluate the efficacy of volumetric CT attenuation-based parameters obtained through automated 3D organ segmentation on virtual non-contrast (VNC) images from dual-energy CT (DECT) for assessing hepatic steatosis. MATERIALS AND METHODS: This retrospective study included living liver donor candidates having liver DECT and MRI-determined proton density fat fraction (PDFF) assessments. Employing a 3D deep learning algorithm, the liver and spleen were automatically segmented from VNC images (derived from contrast-enhanced DECT scans) and true non-contrast (TNC) images, respectively. Mean volumetric CT attenuation values of each segmented liver (L) and spleen (S) were measured, allowing for liver attenuation index (LAI) calculation, defined as L minus S. Agreements of VNC and TNC parameters for hepatic steatosis, i.e., L and LAI, were assessed using intraclass correlation coefficients (ICC). Correlations between VNC parameters and MRI-PDFF values were assessed using the Pearson's correlation coefficient. Their performance to identify MRI-PDFF ≥ 5% and ≥ 10% was evaluated using receiver operating characteristic (ROC) curve analysis. RESULTS: Of 252 participants, 56 (22.2%) and 16 (6.3%) had hepatic steatosis with MRI-PDFF ≥ 5% and ≥ 10%, respectively. LVNC and LAIVNC showed excellent agreement with LTNC and LAITNC (ICC = 0.957 and 0.968) and significant correlations with MRI-PDFF values (r = - 0.585 and - 0.588, Ps < 0.001). LVNC and LAIVNC exhibited areas under the ROC curve of 0.795 and 0.806 for MRI-PDFF ≥ 5%; and 0.916 and 0.932, for MRI-PDFF ≥ 10%, respectively. CONCLUSION: Volumetric CT attenuation-based parameters from VNC images generated by DECT, via automated 3D segmentation of the liver and spleen, have potential for opportunistic hepatic steatosis screening, as an alternative to TNC images.

5.
Liver Transpl ; 29(5): 497-507, 2023 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-36738083

RESUMO

Several major transplantation centers have used composite multimodality evaluation for the preoperative evaluation of potential living liver donors. This approach can be time-consuming and, although rare, can cause complications. We aimed to demonstrate the clinical feasibility of our comprehensive preoperative MR protocol for the preoperative assessment of living liver donor candidates instead of composite multimodality evaluation. Thirty-five consecutive living liver donor candidates underwent multiphasic liver CT and comprehensive donor protocol MR examinations for preoperative evaluation in a single large-volume liver transplantation (LT) center. Three blinded abdominal radiologists reviewed the CT and MR images for vascular and biliary variations. The strength of agreement between CT and MR angiography was assessed using the kappa index. The detection rate of biliary anatomical variations was calculated. The sensitivity and specificity for detecting significant steatosis (>5%) were calculated. The estimated total volume and right lobe volumes measured by MR volumetry were compared with the corresponding CT volumetry measurements using the intraclass correlation coefficient (ICC). Among the 35 patients, 26 underwent LT. The measurement of agreement showed a moderate to substantial agreement between CT and MR angiography interpretations (kappa values, 0.47-0.79; p < 0.001). Combining T2-weighted and T1-weighted MR cholangiography techniques detected all biliary anatomical variations in 9 of the 26 patients. MR-proton density fat fraction showed a sensitivity of 100% (3/3) and a specificity of 91.3% (21/23) for detecting pathologically determined steatosis (>5%). MR volumetry reached an excellent agreement with CT volumetry (reviewers 1 and 2: ICC, 0.92; 95% CI, 0.84-0.96). Our one-stop comprehensive liver donor MR imaging protocol can provide complete information regarding hepatic vascular and biliary anatomies, hepatic parenchymal quality, and liver volume for living liver donor candidates and can replace composite multimodality evaluation.


Assuntos
Transplante de Fígado , Humanos , Transplante de Fígado/efeitos adversos , Meios de Contraste , Imageamento por Ressonância Magnética/métodos , Fígado/diagnóstico por imagem , Fígado/cirurgia , Fígado/irrigação sanguínea , Doadores Vivos
6.
Radiology ; 302(1): 107-115, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34581625

RESUMO

Background Diagnostic performance of the Liver Imaging Reporting and Data System tumor in vein (LR-TIV) category at CT and/or MRI has not yet been evaluated, to the knowledge of the authors. Purpose To assess the diagnostic performance of the LR-TIV category in detecting macroscopic tumors in veins (TIVs) at CT and hepatobiliary contrast agent-enhanced (HBA) MRI, with pathologic results used as the reference standard. Materials and Methods Between January 2010 and December 2019, consecutive patients with or without macroscopic TIV who underwent both CT and HBA MRI before hepatic resection or liver transplant were retrospectively included. Three radiologists independently assessed the LR-TIV features of enhancing soft tissue in vein and features suggestive of TIV (FSTIV) and reached a consensus. Macroscopic TIV at pathologic examination was the reference standard. Sensitivities and specificities of the LR-TIV category without and with FSTIV were calculated, and the added value of FSTIV was evaluated by using the McNemar test. Results In the 1322 patients with (n = 101) or without (n = 1221) macroscopic TIV (median age, 64 years [interquartile range, 58-70 years]; 1053 men), without consideration of FSTIV, the sensitivity and specificity of enhancing soft tissue in vein for detecting macroscopic TIV at pathologic examination were 64.4% (65 of 101) and 99.8% (1218 of 1221) with CT and 62.4% (63 of 101) and 99.8% (1218 of 1221) with HBA MRI, respectively. With consideration of FSTIV, the sensitivity and specificity of the LR-TIV category became 67.3% (68 of 101 patients) and 99.7% (1217 of 1221 patients) at both CT and HBA MRI. No difference was found between measurements without and with FSTIV (sensitivity, 62% vs 67% for CT [P = .45] and 64% vs 67% for HBA MRI [P = .18]; specificity, 99% for both CT and HBA MRI [P > .99 for both]). Conclusion The Liver Imaging Reporting and Data System tumor in vein category showed moderate sensitivity and high specificity in the detection of macroscopic tumors in veins at both CT and hepatobiliary contrast agent-enhanced MRI, with pathologic examination used as the reference standard. © RSNA, 2021 Online supplemental material is available for this article. See also the editorial by Morrell in this issue.


Assuntos
Neoplasias Hepáticas/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Sistemas de Informação em Radiologia , Tomografia Computadorizada por Raios X/métodos , Neoplasias Vasculares/diagnóstico por imagem , Idoso , Meios de Contraste , Feminino , Humanos , Aumento da Imagem/métodos , Fígado/irrigação sanguínea , Fígado/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade
7.
Eur Radiol ; 32(4): 2506-2517, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34647178

RESUMO

OBJECTIVES: To investigate useful MRI features in pancreatic neuroendocrine tumor (PNET) patients for predicting recurrence and its timing after surgery. METHODS: A total of 99 patients with PNET who underwent MRI and surgery from 2000 to 2018 were enrolled. Two radiologists independently assessed MRI findings, including size, location, margin, T1 and T2 signal intensity, enhancement patterns, common bile duct (CBD) or main pancreatic duct (MPD) dilatation, vascular invasion, lymph node enlargement, DWI, and ADC value. Imaging findings associated with recurrence and disease-free survival (DFS) were assessed using logistic regression analysis and Cox proportional hazard regression analysis. RESULTS: The median follow-up period was 40.4 months, and recurrence after surgery occurred in 12.1% (12/99). Among them, 6 patients experienced recurrence within 1 year, and 9 patients experienced recurrence within 2 years after surgery. In multivariate analysis, major venous invasion (OR 10.76 [1.14-101.85], p = 0.04) was associated with recurrence within 1 year, and portal phase iso- to hypoenhancement (OR 51.89 [1.73-1557.89], p = 0.02), CBD or MPD dilatation (OR 10.49 [1.35-81.64], p = 0.03) and larger size (OR 1.05 [1.00-1.10], p = 0.046) were associated with recurrence within 2 years. The mean DFS was 116.4 ± 18.5 months, and the 5-year DFS rate was 85.7%. In multivariate analysis, portal phase iso- to hypoenhancement (HR 21.36 [2.01-197.77], p = 0.01), ductal dilatation (HR 5.22 [1.46-18.68], p = 0.01), major arterial invasion (HR 42.90 [3.66-502.48], p = 0.003), and larger size (HR 1.04 [1.01-1.06], p = 0.01) showed a significant effect on poor DFS. CONCLUSION: MRI features, including size, enhancement pattern, vascular invasion, and ductal dilatation, are useful in predicting recurrence and poor DFS after surgery in PNET. Key Points • MRI features are useful for predicting prognosis in patients with PNET after surgery. • PV or SMV invasion (OR 10.49 [1.35-81.64], p = 0.04) was significantly associated with 1-year recurrence. • Portal phase iso- to hypoenhancement (HR 21.36), CBD or MPD dilatation (HR 5.22), arterial invasion (HR 42.90), and larger size (HR 1.04) had significant effects on poor DFS (p < 0.05).


Assuntos
Tumores Neuroendócrinos , Neoplasias Pancreáticas , Humanos , Imageamento por Ressonância Magnética/métodos , Margens de Excisão , Tumores Neuroendócrinos/diagnóstico por imagem , Tumores Neuroendócrinos/patologia , Tumores Neuroendócrinos/cirurgia , Neoplasias Pancreáticas/diagnóstico por imagem , Neoplasias Pancreáticas/patologia , Neoplasias Pancreáticas/cirurgia , Prognóstico , Estudos Retrospectivos
8.
Eur Radiol ; 32(9): 6407-6417, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35380228

RESUMO

OBJECTIVES: To evaluate the diagnostic value of deep learning model (DLM) reconstructed dual-energy CT (DECT) low-keV virtual monoenergetic imaging (VMI) for assessing hypoenhancing hepatic metastases. METHODS: This retrospective study included 131 patients who underwent contrast-enhanced DECT (80-kVp and 150-kVp with a tin filter) in the portal venous phase for hepatic metastasis surveillance. Linearly blended images simulating 100-kVp images (100-kVp), standard 40-keV VMI images (40-keV VMI), and post-processed 40-keV VMI using a vendor-agnostic DLM (i.e., DLM 40-keV VMI) were reconstructed. Lesion conspicuity and diagnostic acceptability were assessed by three independent reviewers and compared using the Wilcoxon signed-rank test. The contrast-to-noise ratios (CNRs) were also measured placing ROIs in metastatic lesions and liver parenchyma. The detection performance of hepatic metastases was assessed by using a jackknife alternative free-response ROC method. The consensus by two independent radiologists was used as the reference standard. RESULTS: DLM 40-keV VMI, compared to 40-keV VMI and 100-kVp, showed a higher lesion-to-liver CNR (8.25 ± 3.23 vs. 6.05 ± 2.38 vs. 5.99 ± 2.00), better lesion conspicuity (4.3 (4.0-4.7) vs. 3.7 (3.7-4.0) vs. 3.7 (3.3-4.0)), and better diagnostic acceptability (4.3 (4.0-4.3) vs. 3.0 (2.7-3.3) vs. 4.0 (4.0-4.3)) (p < 0.001 for all). For lesion detection (246 hepatic metastases in 68 patients), the figure of merit was significantly higher with DLM 40-keV VMI than with 40-keV VMI (0.852 vs. 0.822, p = 0.012), whereas no significant difference existed between DLM 40-keV VMI and 100-kVp (0.852 vs. 0.842, p = 0.31). CONCLUSIONS: DLM 40-keV VMI provided better image quality and comparable diagnostic performance for detecting hypoenhancing hepatic metastases compared to linearly blended images. KEY POINTS: • DLM 40-keV VMI provides a superior image quality compared with 40-keV or 100-kVp for assessing hypoenhancing hepatic metastasis. • DLM 40-keV VMI has the highest CNR and lesion conspicuity score for hypoenhancing hepatic metastasis due to noise reduction and structural preservation. • DLM 40-keV VMI provides higher lesion detectability than standard 40-keV VMI (p = 0.012).


Assuntos
Aprendizado Profundo , Neoplasias Hepáticas , Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Humanos , Processamento de Imagem Assistida por Computador/métodos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/secundário , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Estudos Retrospectivos , Razão Sinal-Ruído , Tomografia Computadorizada por Raios X/métodos
9.
J Magn Reson Imaging ; 54(4): 1177-1186, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-33779024

RESUMO

BACKGROUND: For surveillance of pancreatic intraductal papillary mucinous neoplasms (IPMNs), magnetic resonance imaging (MRI)/magnetic resonance cholangiopancreatography (MRCP) is preferred over computed tomography, but the long acquisition time limits its use. PURPOSE: To investigate the diagnostic performance of abbreviated MRI with breath-hold (BH) three-dimensional MRCP (abbreviated MRI-BH) for malignant risk assessment of pancreatic IPMN. STUDY TYPE: Retrospective. POPULATION: Two hundred and thirty-five patients with IPMNs (M:F = 115:120; mean age ± SD, 66 ± 9 years; typical imaging features with ≥2-year stability [N = 172] and histopathologically confirmed [N = 63]). FIELD STRENGTH/SEQUENCE: 3.0 T/ abbreviated MRI-BH (single-shot fast spin-echo, T1W fat-suppressed gradient-echo sequence, and BH-3D-MRCP). ASSESSMENT: Abbreviated MRI-BH was reviewed by three reviewers, and its diagnostic performance was assessed using the predetermined scoring system. The diagnostic performance for the mural nodule detection was assessed. Additionally, diagnostic performance of abbreviated MRI was compared with that of full-sequence MRI. STATISTICAL TESTS: Area under the receiver operating characteristic curve (AUC) with z-test, and linear-weighted kappa values. RESULTS: Thirty-five patients had malignant IPMN. At a cut-off score ≥3, AUCs of abbreviated MRI-BH for detecting malignant IPMN were 0.959 for reviewer 1, 0.962 for reviewer 2, and 0.956 for reviewer 3. The sensitivity of reviewers 1, 2, and 3 was 97.1% for all, and the specificity was 85.5%, 86.0%, and 85.0%, respectively. Regarding mural nodule detection (N = 22), abbreviated MRI-BH demonstrated a sensitivity of 95.5% and a specificity of 88.3% for reviewer 1, a sensitivity of 86.4% and a specificity of 92.0% for reviewer 2, and a sensitivity of 86.4% and a specificity of 89.2% for reviewer 3. There were no significant differences between AUC of abbreviated MRI-BH and that of full-sequence MRI in the three reviewers (P > 0.05). DATA CONCLUSION: Abbreviated MRI-BH showed good diagnostic performance for detecting malignant IPMNs by using a predetermined scoring system. LEVEL OF EVIDENCE: 3 TECHNICAL EFFICACY STAGE: 2.


Assuntos
Neoplasias Intraductais Pancreáticas , Suspensão da Respiração , Colangiopancreatografia por Ressonância Magnética , Humanos , Imageamento por Ressonância Magnética , Estudos Retrospectivos
10.
Eur Radiol ; 31(10): 7834-7844, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33768290

RESUMO

OBJECTIVES: To investigate whether 2-[18F]fluoro-2-deoxy-D-glucose ([18F]FDG) positron emission tomography/magnetic resonance imaging (PET/MRI) can improve the diagnostic performance of TNM staging and help in making an accurate decision regarding resectability in patients with recurrent gastric cancer compared to multi-detector computed tomography (MDCT). METHODS: Fifty patients with histologically (n = 31) or clinically (n = 19) confirmed recurrent gastric cancer underwent both MDCT and [18F]FDG PET/MRI. Two radiologists independently assessed TNM staging using MDCT with and without [18F]FDG PET/MRI and scored resectability using a 5-point confidence scale. Diagnostic performance as assessed by radiologists was compared using McNemar's test and receiver operating characteristic curve analysis. RESULTS: Of the 50 patients, pathologic T and N staging was available in seven and six patients, respectively. Diagnostic accuracies for T and N staging were not significantly different between MDCT with and without [18F]FDG PET/MRI for both reviewers (p > 0.05). However, for M staging, diagnostic accuracy was significantly improved when 18F-FDG PET/MRI was added to MDCT alone (68.0% [34/50] to 90.0% [45/50] for reviewer 1 [p = 0.001] and 66.0% [33/50] to 96.0% [46/50] for reviewer 2 [p < 0.001]). Regarding the resectability of recurrent gastric cancers, the addition of [18F]FDG PET/MRI increased the area under the curve values for both reviewers (from 0.860 to 0.989 for reviewer 1 and from 0.778 to 0.898 for reviewer 2), with a statistical significance for reviewer 2 (p = 0.002). CONCLUSION: Compared to MDCT alone, MDCT plus [18F]FDG PET/MRI can improve the diagnostic accuracy for evaluating preoperative M staging as well as resectability for recurrent gastric cancers. KEY POINTS: • [18F]FDG PET/MRI can improve diagnostic accuracy for preoperative M staging in patients with recurrent gastric cancers. • [18F]FDG PET/MRI can improve diagnostic accuracy for determining resectability in patients with recurrent gastric cancers. • [18F]FDG PET/MRI can provide critical clues for management options for recurrent gastric cancers.


Assuntos
Fluordesoxiglucose F18 , Neoplasias Gástricas , Humanos , Imageamento por Ressonância Magnética , Tomografia Computadorizada Multidetectores , Recidiva Local de Neoplasia/diagnóstico por imagem , Estadiamento de Neoplasias , Tomografia por Emissão de Pósitrons , Compostos Radiofarmacêuticos , Neoplasias Gástricas/diagnóstico por imagem , Neoplasias Gástricas/patologia , Neoplasias Gástricas/cirurgia
11.
Eur Radiol ; 31(3): 1432-1442, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32880698

RESUMO

OBJECTIVES: To determine the prognostic value of CT-based splenic volume measurement in patients with compensated chronic liver disease (cCLD) from chronic hepatitis B (CHB). METHODS: A total of 584 patients having multiphasic liver CT scans between January and December 2011 were retrospectively reviewed. Spleen volume was measured using a semi-automated three-dimensional volumetric software program. Electronic medical records and national registry data were reviewed to determine the diagnosis of hepatocellular carcinoma (HCC), hepatic decompensation, or death. The cumulative incidence (CI) of the development of decompensation, HCC occurrence, and overall survival (OS) were estimated by the Kaplan-Meier method. The Cox proportional hazard regression model was used to evaluate prognostic factors. The optimal cutoff spleen volume to predict each outcome was obtained using a minimal p value approach method. RESULTS: After a median follow-up of 92 months, 114 patients developed HCC with a 7-year CI of 17.2%. A larger spleen volume was a significant predictor of HCC occurrence (HR = 2.13, p = 0.009). Decompensation occurred in 30 patients with a 7-year CI of 5.0%, and a larger spleen volume was also significantly associated with the development of decompensation (HR = 4.66, p = 0.005). Twenty-three patients died, and their estimated 7-year OS was 96.4%. A larger spleen volume also significantly affected OS (HR = 6.15, p = 0.007). The optimal cutoff spleen volume was set at 532 mL for HCC occurrence, 656.9 mL for the development of decompensation, and 741.1 mL for OS. CONCLUSIONS: A larger spleen volume was significantly associated with HCC occurrence, development of decompensation, and poor OS in patients with cCLD from CHB. KEY POINTS: • Spleen volume could be easily acquired from routine multiphasic liver CT scan using a semi-automated 3D volumetric software program with excellent inter-observer agreement. • A larger spleen volume was significantly associated with a higher rate of hepatocellular carcinoma occurrence, the development of decompensation, and poor overall survival in patients with compensated chronic liver disease from chronic hepatitis B.


Assuntos
Carcinoma Hepatocelular , Hepatite B Crônica , Hepatite B , Neoplasias Hepáticas , Viroses , Carcinoma Hepatocelular/diagnóstico por imagem , Hepatite B/complicações , Hepatite B/diagnóstico por imagem , Hepatite B Crônica/complicações , Hepatite B Crônica/diagnóstico por imagem , Humanos , Cirrose Hepática , Neoplasias Hepáticas/diagnóstico por imagem , Prognóstico , Estudos Retrospectivos , Baço/diagnóstico por imagem , Tomografia , Tomografia Computadorizada por Raios X
12.
Eur Radiol ; 31(10): 7734-7745, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33787974

RESUMO

OBJECTIVES: To investigate an additional value of [68Ga]Ga-DOTA-TOC PET/CT for characterizing suspected pancreatic neuroendocrine neoplasms (NENs) in a large study cohort. METHODS: This retrospective study included 167 patients who underwent [68Ga]Ga-DOTA-TOC PET/CT for suspected pancreatic NENs detected by contrast-enhanced CT (n = 153) and/or MRI (n = 85). Two board-certified radiologists independently reviewed CT and/or MRI as well as [68Ga]Ga-DOTA-TOC PET/CT and scored the probability of NEN on a 5-point scale. Radiologists' diagnostic performances with and without [68Ga]Ga-DOTA-TOC PET/CT were compared using pathologic findings as the standard of reference. RESULTS: All 167 patients were pathologically diagnosed with NENs (n = 131) or non-NENs (n = 36) by surgery (n = 93) or biopsy (n = 74). The non-NEN group included focal pancreatitis (n = 7), gastrointestinal stromal tumor (n = 6), serous cystadenoma (n = 5), metastatic renal cell carcinoma (n = 4), intrapancreatic accessory spleen (n = 4), ductal adenocarcinoma (n = 3), solid pseudopapillary neoplasm (n = 2), intraductal papillary mucinous carcinoma (n = 1), adenosquamous carcinoma (n = 1), schwannoma (n = 1), paraganglioma (n = 1), and solitary fibrous tumor (n = 1). Radiologists' diagnostic performance significantly improved after the addition of [68Ga]Ga-DOTA-TOC PET/CT (AUC of CT: 0.737 vs. 0.886 for reviewer 1 [p = 0.0004]; 0.709 vs. 0.859 for reviewer 2 [p = 0.0002], AUC of MRI: 0.748 vs. 0.872 for reviewer 1 [p = 0.023]; 0.670 vs. 0.854 for reviewer 2 [p = 0.001]). [68Ga]Ga-DOTA-TOC PET/CT significantly improved sensitivity (CT: 87.4% vs. 96.6% for reviewer 1 [p = 0.001]; 74.8% vs. 92.5% for reviewer 2 [p = 0.0001], MRI: 86.9% vs. 98.4% for reviewer 1 [p = 0.016]; 70.5% vs. 91.8% for reviewer 2 [p = 0.002]). CONCLUSIONS: [68Ga]Ga-DOTA-TOC PET/CT provided an additional value over conventional CT or MRI for the characterization of suspected pancreatic NENs. KEY POINTS: • [68Ga]Ga-DOTA-TOC PET/CT could provide additional value over conventional CT and/or MRI for the exact characterization of suspected pancreatic NENs by increasing AUC values and sensitivity. • Diagnostic improvement was significant, especially in NENs showing an atypical enhancement pattern. • The inter-observer agreement was improved when [68Ga]Ga-DOTA-TOC PET/CT was added to CT and/or MRI.


Assuntos
Carcinoma de Células Renais , Neoplasias Renais , Tumores Neuroendócrinos , Compostos Organometálicos , Neoplasias Pancreáticas , Radioisótopos de Gálio , Humanos , Imageamento por Ressonância Magnética , Tumores Neuroendócrinos/diagnóstico por imagem , Octreotida , Neoplasias Pancreáticas/diagnóstico por imagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Tomografia por Emissão de Pósitrons , Estudos Retrospectivos
13.
Eur Radiol ; 31(5): 3394-3404, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33140171

RESUMO

OBJECTIVES: To investigate the utility of MR findings and texture analysis for predicting the malignant potential of pancreatic intraductal papillary mucinous neoplasms (IPMNs). METHODS: Two hundred forty-eight patients with surgically confirmed IPMNs (106 malignant [invasive carcinoma/high-grade dysplasia] and 142 benign [low/intermediate-grade dysplasia]) and who underwent magnetic resonance imaging (MRI) with MR cholangiopancreatography (MRCP) were included. Two reviewers independently analyzed MR findings as proposed by the 2017 international consensus guidelines. Texture analysis of MRCP was also performed. A multivariate logistic regression analysis was used to identify predictors for malignant IPMNs. Diagnostic performance was also analyzed using receiver operating curve analysis. RESULTS: Among MR findings, enhancing mural nodule size ≥ 5 mm, main pancreatic duct (MPD) ≥ 10 mm or MPD of 5 to 9 mm, and abrupt change of MPD were significant predictors for malignant IPMNs (p < 0.05). Among texture variables, significant predictors were effective diameter, surface area, sphericity, compactness, entropy, and gray-level co-occurrence matrix entropy (p < 0.05). At multivariate analysis, enhancing mural nodule ≥ 5 mm (odds ratios (ORs), 6.697 and 6.968, for reviewers 1 and 2, respectively), MPD ≥ 10 mm or MPD of 5 to 9 mm (ORs, 4.098 and 4.215, and 2.517 and 3.055, respectively), larger entropy (ORs, 1.485 and 1.515), and smaller compactness (ORs, 0.981 and 0.977) were significant predictors for malignant IPMNs (p < 0.05). When adding texture variable to MR findings, diagnostic performance for predicting malignant IPMNs improved from 0.80 and 0.78 to 0.85 and 0.85 in both reviewers (p < 0.05), respectively. CONCLUSIONS: MRCP-derived texture features are useful for predicting malignant IPMNs, and the addition of texture analysis to MR features may improve diagnostic performance for predicting malignant IPMNs. KEY POINTS: • Among the MR imaging findings, an enhancing mural nodule size ≥ 5 mm and dilated main pancreatic ducts are independent predictors for malignant IPMNs. • Greater entropy and smaller compactness on MR texture analysis are independent predictors for malignant IPMNs. • The addition of MR texture analysis improved the diagnostic performance for predicting malignant IPMNs from 0.80 and 0.78 to 0.85 and 0.85, respectively.


Assuntos
Carcinoma Ductal Pancreático , Neoplasias Intraductais Pancreáticas , Neoplasias Pancreáticas , Carcinoma Ductal Pancreático/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética , Pâncreas , Ductos Pancreáticos/diagnóstico por imagem , Neoplasias Intraductais Pancreáticas/diagnóstico por imagem , Neoplasias Pancreáticas/diagnóstico por imagem , Estudos Retrospectivos
14.
Eur Radiol ; 31(4): 2461-2471, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33026503

RESUMO

OBJECTIVES: Post-hepatectomy liver failure (PHLF) can occur as a major complication after hepatic resection (HR) in patients with hepatocellular carcinoma (HCC) and negatively affects the prognosis. We aimed to retrospectively assess whether the spleen volume (SV) measured from preoperative CT images would be associated with the development of PHLF and overall survival (OS) after HR in patients with HCC. METHODS: We enrolled 317 consecutive patients with very early/early stage HCC who underwent a preoperative CT and HR between January 2010 and December 2016. The SV was obtained from preoperative CT images using semi-automated volumetric software and was divided by body surface area to yield SVBSA. Receiver operating characteristic (ROC) curves and logistic regression analyses were performed to identify factors affecting the development of PHLF. The Cox proportional hazard model was used to identify prognostic factors for OS. RESULTS: PHLF was observed in 72 patients (22.7% [72/317]). SVBSA was associated with the development of PHLF (odds ratio, 2.321; 95% CI, 1.347-4.001; p = 0.002) with the area under the ROC curve of 0.663 using the cutoff value of 107.5 cm3 (p < 0.001). SVBSA was also an influencing factor for OS (hazard ratio, 3.935; 95% CI 1.520-10.184; p = 0.005), with the optimal cutoff of 146 cm3. The 5-year OS rate was higher in 245 patients with a SVBSA ≤ 146 cm3 than in 72 patients with a SVBSA > 146 cm3 (95.0% vs. 78.7%, p < 0.001). CONCLUSIONS: In patients with HCC, a larger SVBSA was associated with a higher rate of PHLF and worse OS after HR. The SVBSA may be useful in selecting good surgical candidates. KEY POINTS: • A significantly higher spleen volume divided by body surface area was observed in patients who experienced post-hepatectomy liver failure than in patients who did not (148 cm3 vs. 112 cm3, p < 0.001). • The area under the receiver operating characteristic curve of spleen volume divided by body surface area to predict the development of post-hepatectomy liver failure was 0.663 (p < 0.001). • Spleen volume divided by body surface area was a significant influencing factor for overall survival (hazard ratio, 3.935; 95% CI, 1.520-10.184; p < 0.001), with the optimal cutoff of 146 cm3.


Assuntos
Carcinoma Hepatocelular , Falência Hepática , Neoplasias Hepáticas , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/cirurgia , Hepatectomia , Humanos , Falência Hepática/diagnóstico por imagem , Falência Hepática/etiologia , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/cirurgia , Estudos Retrospectivos , Baço/diagnóstico por imagem
15.
Radiology ; 296(3): 554-561, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32692297

RESUMO

Background The Liver Imaging Reporting and Data System Treatment Response (LR-TR) algorithm is used to assess the response of hepatocellular carcinoma (HCC) to local-regional therapy (LRT) based on enhancement patterns. The potential value of adding MRI ancillary features (AFs) needs to be investigated. Purpose To evaluate the potential application of MRI AFs in category adjustment to detect pathologic tumor viability in comparison with the LR-TR algorithm in CT and gadoxetic acid-enhanced MRI. Materials and Methods This retrospective study included patients with HCCs treated with LRT followed by surgical resection or liver transplantation between January 2014 and December 2017 who underwent both post-LRT CT and gadoxetic acid-enhanced MRI. For each treated observation, treatment response (TR) categories were assigned based on a consensus reading of three radiologists according to the LR-TR algorithm in CT and MRI and according to the MRI-modified TR algorithm in which MRI AFs were allowed for category adjustment. The diagnostic performances of CT LR-TR viable, MRI LR-TR viable, and MRI-modified TR viable categories were compared intraindividually with the McNemar test, with pathologic tumor viability used as a reference standard. Results A total of 138 patients (119 men; mean age, 58 years ± 9 [standard deviation]) with 138 treated observations (108 pathologically viable) were evaluated. The sensitivity and specificity of CT LR-TR viable and MRI LR-TR viable categories for predicting tumor viability were 73% (79 of 108 lesions; 95% confidence interval [CI]: 64%, 81%) versus 76% (82 of 108 lesions; 95% CI: 67%, 84%) and 90% (27 of 30 lesions; 95% CI: 74%, 98%) versus 83% (25 of 30 lesions; 95% CI: 65%, 94%), respectively, without differences between CT and MRI (P = .65 and P = .63, respectively). MRI-modified TR viable category had higher sensitivity (84% [91 of 108 lesions; 95% CI: 76%, 91%]) than CT or MRI LR-TR viable category (P = .002 and P = .01, respectively), without difference in specificity (80% [24 of 30 lesions]; 95% CI: 61%, 92%) (P = .38 and P > .99, respectively). Conclusion The application of MRI ancillary features to the Liver Imaging Reporting and Data System Treatment Response algorithm resulted in higher sensitivity and no change in specificity compared with CT or MRI enhancement patterns alone in the prediction of pathologic tumor viability in patients with hepatocellular carcinoma. © RSNA, 2020 Online supplemental material is available for this article. See also the editorial by Do and Mendiratta-Lala in this issue.


Assuntos
Carcinoma Hepatocelular , Fígado , Imageamento por Ressonância Magnética , Tomografia Computadorizada por Raios X , Idoso , Algoritmos , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/epidemiologia , Carcinoma Hepatocelular/patologia , Carcinoma Hepatocelular/cirurgia , Feminino , Hepatectomia , Humanos , Fígado/diagnóstico por imagem , Fígado/patologia , Fígado/cirurgia , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/epidemiologia , Neoplasias Hepáticas/patologia , Neoplasias Hepáticas/cirurgia , Transplante de Fígado , Masculino , Pessoa de Meia-Idade , Sistemas de Informação em Radiologia , Estudos Retrospectivos
16.
Liver Int ; 40(5): 1189-1200, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-32056353

RESUMO

BACKGROUND & AIMS: A recent study showed that serum tumour marker-based MoRAL score (11×√protein induced by vitamin K absence-II [PIVKA] +2×√alpha-foetoprotein [AFP]) can reflect both tumour burden and aggressiveness of hepatocellular carcinoma (HCC). This study aimed to evaluate whether baseline MoRAL score could predict tumour recurrence after radiofrequency ablation (RFA) for very-early/early-stage HCC. METHODS: A total of 576 HCC patients who underwent RFA as initial treatment were enrolled from two tertiary referral hospitals (256 in development cohort and 320 in validation cohort). The primary endpoint was recurrence-free survival (RFS) and the secondary endpoints included cumulative risks of intrahepatic distant recurrence (IDR) and extrahepatic metastasis (EM). RESULTS: In the development cohort, MoRAL score was an independent prognostic factor of RFS (P = .02). The optimal cutoff MoRAL score for predicting RFS was 68. Patients with high MoRAL score (>68) showed significantly shorter RFS than did those with low MoRAL score (hazard ratio [HR] = 2.04, P < .001). The 5-year RFS rates were 32.3% and 53.2% in high- and low-MoRAL groups respectively. Risks of both IDR (HR = 1.76, P = .003) and EM (HR = 8.25, P = .006) were also significantly higher in high MoRAL group. These results were reproduced in the validation cohort: RFS (HR = 1.81, P < .001; 5-year RFS rates = 27.7% vs 53.6%) was significantly shorter and risks of IDR (HR = 1.59, P = .003) and EM (HR = 6.19, P = .004) were significantly higher in high MoRAL group. CONCLUSION: A high MoRAL score of >68 was significant a predictive factor of tumour recurrence after RFA for very-early/early-stage HCC. Moreover, it might be warranted to evaluate EM in patients with high baseline MoRAL scores.


Assuntos
Carcinoma Hepatocelular , Ablação por Cateter , Neoplasias Hepáticas , Ablação por Radiofrequência , Biomarcadores Tumorais , Carcinoma Hepatocelular/cirurgia , Ablação por Cateter/efeitos adversos , Humanos , Neoplasias Hepáticas/cirurgia , Recidiva Local de Neoplasia , Ablação por Radiofrequência/efeitos adversos , Estudos Retrospectivos , Resultado do Tratamento
17.
Eur Radiol ; 30(3): 1634-1643, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31781931

RESUMO

OBJECTIVES: To investigate whether multiparametric magnetic resonance imaging (MRI) and 18F-fluorodeoxyglucose positron emission tomography (PET) can be helpful in differentiating gastrointestinal stromal tumors (GISTs) from non-GISTs and high-risk GISTs from low-risk GISTs. METHODS: This retrospective study included 56 patients with pathologically confirmed GISTs (n = 39), leiomyoma (n = 8), schwannoma (n = 5), heterotopic pancreas (n = 3), and glomus tumor (n = 1) who underwent MRI and/or PET examinations. Two radiologists reviewed MRI regarding location, shape, contour, growth pattern, margin, signal intensity (SI) on T1- (T1WI) and T2-weighted images (T2WI), degree and pattern of enhancement, hemorrhage, and necrosis. Mean apparent diffusion coefficient (ADC) and maximum standardized uptake value (SUVmax) were measured. Imaging features were compared among non-GISTs, low-risk GISTs, and high-risk GISTs using uni- and multivariate statistical analyses. RESULTS: Size, longitudinal location, shape, contour, growth pattern, SI on T1- and T2WI, enhancement pattern, hemorrhage, necrosis, ADC, and SUVmax were significantly different among non-GISTs, low-risk GISTs, and high-risk GISTs (p < 0.05). On multivariate analysis, SI on T2WI (hazard ratio [HR], 66.0; p = 0.002) was the only independent variable for differentiating GISTs from non-GISTs whereas enhancement pattern (HR, 56.0; p = 0.041), ADC (HR, 0.997; p = 0.01), and SUVmax (HR, 2.08; p = 0.027) were significant features for differentiating between high-risk and low-risk GISTs. CONCLUSIONS: Several qualitative and quantitative MRI and PET features including ADC and SUVmax values are significantly different among non-GISTs, low-risk GISTs, and high-risk GISTs. Multiparametric information obtained from MRI with or without PET can be useful for differentiation of gastric subepithelial tumors as well as for determining patients' management and prognosis. KEY POINTS: • Several qualitative MRI features are helpful in distinguishing gastrointestinal stromal tumors (GISTs) from non-GISTs as well as high-risk GISTs from low-risk GISTs. • Apparent diffusion coefficient value on diffusion-weighted imaging can be useful in distinguishing GISTs from non-GISTs as well as high-risk GISTs from low-risk GISTs. • PET has the potential to distinguish between high-risk and low-risk GISTs.


Assuntos
Fluordesoxiglucose F18/farmacologia , Tumores do Estroma Gastrointestinal/diagnóstico , Imageamento por Ressonância Magnética Multiparamétrica/métodos , Tomografia por Emissão de Pósitrons/métodos , Neoplasias Gástricas/diagnóstico , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Tumores do Estroma Gastrointestinal/patologia , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Compostos Radiofarmacêuticos/farmacologia , Estudos Retrospectivos
18.
Eur Radiol ; 30(9): 4762-4771, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32333148

RESUMO

OBJECTIVES: To compare diagnostic performances of current guidelines for the diagnosis of HCC in LT candidates using gadoxetic acid-enhanced liver MRI (Gd-EOB-MRI). METHODS: Eighty-one patients (119 HCCs and 35 non-HCCs) who underwent preoperative Gd-EOB-MRI and subsequent LT were included. Per-lesion imaging diagnoses of HCCs were made using four different guidelines (American Association for the Study of Liver Disease (AASLD), European Association for the Study of the Liver (EASL), Asian Pacific Association for the Study of the Liver (APASL), and Korean Liver Cancer Association-National Cancer Center (KLCA-NCC) guidelines, and patient allocation was determined according to Milan criteria (MC). Comparisons of per-lesion sensitivity, specificity, and accuracy of patient allocation between guidelines were performed using logistic regression with generalized estimating equations. RESULTS: For diagnosis of HCC, AASLD guideline showed highest specificity (97.4%), followed by EASL and KLCA-NCC guidelines (92.1% and 92.1%, p > 0.99 and = 0.15, respectively, in comparison to AASLD), while the specificity of APASL guideline was significantly lower than that of AASLD guideline (78.9% vs. 97.4%, p = 0.006). APASL and KLCA-NCC guidelines (75.9% and 65.6%) showed significantly higher sensitivities than AASLD/EASL guidelines (34.5% and 38.8%, respectively; all ps < 0.001). For organ allocation, KLCA-NCC guideline showed higher accuracy in selecting unsuitable candidates (with non-HCC malignancies or beyond MC HCCs) than EASL guideline (68.4% vs. 31.8%; p = 0.001). CONCLUSION: For the diagnosis of HCCs using Gd-EOB-MRI, AASLD guideline provided the highest specificity, followed by EASL, KLCA-NCC, and APASL guidelines with statistically significant difference with only APASL guideline. KLCA-NCC guideline provided the most accurate selection of unsuitable LT candidates. KEY POINTS: • AASLD/LI-RADS showed the highest specificity, followed by EASL and KLCA-NCC guidelines. • APASL and KLCA-NCC guidelines allowed more sensitive diagnoses of HCCs. • KLCA-NCC more accurately classified patients not appropriate transplantation candidates than EASL.


Assuntos
Carcinoma Hepatocelular/diagnóstico por imagem , Meios de Contraste , Gadolínio DTPA , Neoplasias Hepáticas/diagnóstico por imagem , Transplante de Fígado , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Carcinoma Hepatocelular/patologia , Feminino , Humanos , Neoplasias Hepáticas/patologia , Masculino , Pessoa de Meia-Idade , Guias de Prática Clínica como Assunto , Estudos Retrospectivos , Sensibilidade e Especificidade
19.
Eur Radiol ; 30(5): 2890-2901, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-32025835

RESUMO

OBJECTIVES: To identify MRI features that are helpful for the differentiation of gallbladder neuroendocrine tumors (GB-NETs) from gallbladder adenocarcinomas (GB-ADCs) and to evaluate their prognostic values. METHODS: Between January 2008 and December 2018, we retrospectively enrolled patients who underwent MRI for GB malignancy. Two radiologists independently assessed the MRI findings and reached a consensus. Significant MRI features, which distinguish GB-NETs from GB-ADCs, were identified. Cox regression analyses were performed to find MRI features that were prognostic for overall survival. RESULTS: There were 63 patients with GB-NETs (n = 21) and GB-ADCs (n = 42). Compared with GB-ADCs, GB-NETs more frequently demonstrated the following MRI features: well-defined margins, intact overlying mucosa, and thick rim contrast enhancement and/or diffusion restriction (ps < 0.001). Liver metastases were more common and demonstrated thick rim contrast enhancement and diffusion restriction in GB-NETs (ps < 0.001). Lymph node (LN) metastasis showed thick rim diffusion restriction more often in GB-NETs than in GB-ADCs (p = 0.009). On quantitative analysis, the sizes of the GB mass and metastatic LNs in GB-NETs were larger than those in GB-ADCs (p = 0.002 and p = 0.010, respectively). The ratio of apparent diffusion coefficient values between the lesion and the spleen was lower in the GB mass, liver metastases, and LN metastases of GB-NETs than those of GB-ADCs (p < 0.001, p = 0.017, and p < 0.001, respectively). Survival analysis revealed that a large metastatic LN (hazard ratio 1.737; 95% confidence interval, 1.112-2.712) was the only poor prognostic factor (p = 0.015). CONCLUSION: Several MRI features aided in differentiating between GB-NETs and GB-ADCs. A large metastatic LN was associated with poor survival. KEY POINTS: • Compared with gallbladder adenocarcinomas (GB-ADCs), neuroendocrine tumors (GB-NETs) and their metastases to the liver and lymph nodes more frequently demonstrated a thick rim appearance on contrast-enhanced MRI and diffusion-weighted images. • The ratio of apparent diffusion coefficient values between the lesion and the spleen was significantly lower for the primary mass, liver metastases, and lymph node metastases of GB-NETs than for those of GB-ADCs. • A large metastatic lymph node was the only poor prognostic factor for overall survival in patients with GB-NETs and GB-ADCs.


Assuntos
Adenocarcinoma/diagnóstico por imagem , Neoplasias da Vesícula Biliar/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Tumores Neuroendócrinos/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Diagnóstico Diferencial , Feminino , Vesícula Biliar/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Reprodutibilidade dos Testes , Estudos Retrospectivos
20.
Ultrasonography ; 43(2): 88-97, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38310870

RESUMO

PURPOSE: The utility of contrast-enhanced ultrasound (CEUS)-guided liver biopsy in patients with treated hepatocellular carcinoma (HCC) was evaluated. METHODS: This study prospectively enrolled 36 patients (mean age±standard deviation [SD], 65.3±9.2 years; 31 men) who underwent CEUS-guided biopsy for treated HCC between September 2020 and April 2022, constituting the CEUS group. An additional 60 patients (mean age±SD, 60.7±12.3 years; 50 men) who underwent B-mode image-guided biopsy for treated HCC between January 2017 and December 2018 were retrospectively enrolled in the B-mode, or control, group. Biopsy success rates were compared between CEUS and B-mode groups using the chi-square test. RESULTS: The biopsy success rate in the CEUS group was 88.9% (32 of 36 patients), which was significantly higher than the 70.0% (42 of 60 patients) observed in the B-mode group (P=0.044). No significant difference was found between CEUS and B-mode groups in the size of the lesions targeted for biopsy (mean±SD, 3.8±2.3 cm vs. 3.7±3.3 cm, respectively; P=0.332). For both the whole tumor and the viable tumor, conspicuity scores were significantly higher on CEUS than on grayscale ultrasound in the CEUS group (whole tumor: 2.7±0.5 vs. 1.8±0.9, P<0.001; viable tumor: 2.6±0.7 vs. 1.4±0.8, P<0.001). Relative to non-diagnostic results, diagnostic results more frequently exhibited a late mild washout pattern (87.5% [28 of 32] vs. 25.0% [1 of 4], P=0.004). No significant difference in the arterial enhancement pattern was noted between these subgroups (P=0.415). CONCLUSION: By increasing the viable-tumor conspicuity, CEUS-guided biopsy is useful for confirmative histopathologic diagnosis in patients with treated HCC.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa