RESUMO
OBJECTIVES: To explore the influencing factors of bone cement leakage in the paravertebral vein after vertebroplasty for the treatment of osteoporotic vertebral compression fractures (OVCFs) and to determine the correlation between the puncture-side bone cement/vertebral body volume ratio and bone cement leakage in the paravertebral vein. METHODS: This was a retrospective analysis of 495 patients (585 vertebral bodies) with OVCFs treated from August 2018 to May 2021 in our hospital. The patients' postoperative CT data were imported into Mimics software, and the three-dimensional(3D) reconstruction function was used to calculate the bone cement volume (BCV), puncture-side bone cement volume (PSBCV), and vertebral body volume (VBV); the bone cement/vertebral body volume ratio (BCV/VCV%) and puncture-side bone cement/vertebral body volume ratio (PSBCV/VCV%) were additionally calculated. Sex, Age, Body mass index(BMI), Bone density, BCV, PSBCV, VBV, BCV/VCV%, and PSBCV/VCV were compared between the leakage group and the non-leakage group. Logistic regression analysis was used to assess the correlations between the factors that statistically significantly differed between the two groups and the presence of leakage in the paravertebral veins. A receiver operating characteristic (ROC) curve was used to determine the diagnostic value of the PSBCV/VCV% and to obtain the optional cut-off value. RESULTS: A total of 102 males and 393 females with an average age of 72.89 (52 ~ 93) years were included in our study. There were 57 cases of cement leakage (59 vertebral bodies) in the paravertebral vein. There were 438 patients (526 vertebral bodies) without paravertebral cement leakage. Univariate analysis showed that the differences in sex, bone density, PSBCV, and PSBCV/VCV% between the two groups were statistically significant (P < 0.05). Logistic regression analysis showed that there were correlations between sex, bone density, and PSBCV/VCV% and the presence of paravertebral cement leakage (P < 0.05). The ROC curve showed that the area under the curve of the PSBCV/VCV% for the diagnosis of cement leakage in the paravertebral vein was greater than 0.65, and P < 0.05, indicating a diagnostic value. The best cut-off point for the diagnosis of paravertebral cement leakage with the PSBCV/VCV% was 13.68%, with a sensitivity of 84.7% and specificity of 37.8%. CONCLUSION: Sex, bone density, and PSBCV/VCV% are risk factors for cement leakage in the paravertebral veins after vertebroplasty for the treatment of OVCFs; the PSBCV/VCV% is strongly associated with paravertebral venous leakage, and the optimal PSBCV/VCV% is 13.68%. When the PSBCV/VCV% exceeds the optimal value, the risk of cement leakage in the paravertebral vein becomes significantly increased.
Assuntos
Fraturas por Compressão , Fraturas por Osteoporose , Fraturas da Coluna Vertebral , Vertebroplastia , Idoso , Cimentos Ósseos/efeitos adversos , Feminino , Fraturas por Compressão/complicações , Fraturas por Compressão/diagnóstico por imagem , Fraturas por Compressão/cirurgia , Humanos , Masculino , Fraturas por Osteoporose/cirurgia , Punções/efeitos adversos , Estudos Retrospectivos , Fraturas da Coluna Vertebral/induzido quimicamente , Fraturas da Coluna Vertebral/diagnóstico por imagem , Fraturas da Coluna Vertebral/cirurgia , Resultado do Tratamento , Corpo Vertebral , Vertebroplastia/efeitos adversosRESUMO
OBJECTIVE: To evaluate the accuracy and safety of a combined 3D printed guide template (combined template) to assist iliosacral (IS) screw placement for sacral fracture and dislocation. METHODS: A total of 37 patients, 24 men and 13 women, age from 22 to 68 years old, diagnosed with a sacral fracture and dislocation were involved in this study for retrospective analysis from January 2016 to February 2018. There were 19 patients in the template group (42 screws) and 18 patients in the conventional group (31 screws). In the combined template group, IS screw placement was assisted by a combined 3D printed template; in the conventional group, the IS screws were placed freehand under fluoroscopy. The accuracy of the IS screw placement was evaluated by comparing the screw angle and the location of the screw entry point between the actual and the simulated screw in the combined template group. The safety of the IS screw placement was evaluated by comparing the quality of the reduction, the grading of the screws, the operation time, and radiation exposure times between groups. RESULTS: A total of 73 pedicle screws were placed in 37 patients: 42 screws (30 S1, 12 S2) in the combined template group and 31 screws (23 S1, 8 S2) in the conventional group. In the conventional group, 1 patient developed symptoms of L5 nerve stimulation. In the combined template group, the average operative time of each screw was 25.01 ± 2.90 min, with average radiation exposure times of 12.05 ± 4.00. In the conventional group, the average operative time of each screw was 46.24 ± 9.59 min, with an average radiation exposure time of 56.10 ± 6.75. There were significant differences in operation and radiation exposure times between groups. The rate of screw perforation was lower in the combined template group (2 of 42 screws, 0 at grade III and 2 at grade II) than in the conventional group (5 of 38 screws, 2 at grade III and 3 at grade III). In the combined template group, the mean distance between the entry points of the actual and simulated screws was 1.4 ± 0.9 mm, with a mean angle of deviation of 2.1° ± 1.6°. All patients were followed up once every 3 months and were followed for 3 to 12 months. CONCLUSION: Using the combined template to assist with the insertion of IS screws delivered good accuracy, less fluoroscopy and shorter operation time, and avoided neurovascular injury as a result of screw malposition.
Assuntos
Parafusos Ósseos , Fixação Interna de Fraturas/métodos , Fraturas Ósseas/cirurgia , Ílio/cirurgia , Impressão Tridimensional , Sacro/cirurgia , Adulto , Idoso , Feminino , Humanos , Luxações Articulares/cirurgia , Masculino , Pessoa de Meia-Idade , Modelagem Computacional Específica para o Paciente , Estudos Retrospectivos , Sacro/lesõesRESUMO
OBJECTIVE: To construct a novel non-viral vector loaded with growth and differentiation factor-5 (GDF-5) plasmid using chitosan, hyaluronic acid, and chondroitin sulfate for osteoarthritis (OA) gene therapy. METHODS: Nano-microspheres (NMPs) were prepared by mixing chitosan, hyaluronic acid, and chondroitin sulfate. GDF-5 plasmid was encapsulated in the NMPs through electrostatic adsorption. The basic characteristics of the NMPs were observed, and then they were co-cultured with chondrocytes to observe their effects on extracellular matrix (ECM) protein expression. Finally, NMPs loaded with GDF-5 were injected into the articular cavities of rabbits to observe their therapeutic effects on OA in vivo. RESULTS: NMPs exhibited good physicochemical properties and low cytotoxicity. Their average diameter was (0.61±0.20) µm, and encapsulation efficiency was (38.19±0.36)%. According to Cell Counting Kit-8 (CCK-8) assay, relative cell viability was 75%-99% when the total weight of NMPs was less than 560 µg. Transfection efficiency was (62.0±2.1)% in a liposome group, and (60.0±1.8)% in the NMP group. There was no significant difference between the two groups (P>0.05). Immunohistochemical staining results suggested that NMPs can successfully transfect chondrocytes and stimulate ECM protein expression in vitro. Compared with the control groups, the NMP group significantly promoted the expression of chondrocyte ECM in vivo (P<0.05), as shown by analysis of the biochemical composition of chondrocyte ECM. When NMPs were injected into OA model rabbits, the expression of ECM proteins in chondrocytes was significantly promoted and the progression of OA was slowed down. CONCLUSIONS: Based on these data, we think that these NMPs with excellent physicochemical and biological properties could be promising non-viral vectors for OA gene therapy.