Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Respir Care ; 69(8): 924-930, 2024 Jul 24.
Artigo em Inglês | MEDLINE | ID: mdl-38688544

RESUMO

BACKGROUND: The bag-valve-mask (BVM) or manual resuscitator bag is used as a first-line technique to ventilate patients with respiratory failure. Volume-restricted manual resuscitator bags (eg, pediatric bags) have been suggested to minimize overventilation and associated complications. There are studies that both support and caution against the use of a pediatric resuscitator bag to ventilate an adult patient. In this study, we evaluated the ability of pre-hospital clinicians to adequately ventilate an adult manikin with both an adult- and pediatric-size manual resuscitator bag without the assistance of an advanced airway or airway adjunct device. METHODS: This study was conducted at an international conference in 2022. Conference attendees with pre-hospital health care experience were recruited to ventilate an adult manikin using a BVM for 1 min with both an adult and pediatric resuscitator bag, without the use of adjunct airway devices, while 6 ventilatory variables were collected or calculated: tidal volume (VT), breathing frequency, adequate breaths (VT > 150 mL), proportion of adequate breaths, peak inspiratory pressure (PIP), and estimated alveolar ventilation (EAV). RESULTS: A total of 208 participants completed the study. Ventilation with the adult-sized BVM delivered an average VT of 290.4 mL compared to 197.1 mL (P < .001) when using the pediatric BVM. PIP with the adult BVM was higher than with the pediatric BVM (10.6 cm H2O vs 8.6 cm H2O, P < .001). The median EAV with the adult bag (1,138.1 [interquartile range [IQR] 194.0-2,869.9] mL/min) was markedly greater than with the pediatric BVM (67.7 [IQR 0-467.3] mL/min, P < .001). CONCLUSIONS: Both pediatric- and adult-sized BVM provided lower ventilation volumes than those recommended by professional guidelines for an adult. Ventilation with the pediatric BVM was significantly worse than with the adult bag when ventilating a simulated adult subject.


Assuntos
Manequins , Respiração Artificial , Volume de Ventilação Pulmonar , Humanos , Adulto , Respiração Artificial/instrumentação , Respiração Artificial/métodos , Insuficiência Respiratória/terapia , Masculino , Feminino , Desenho de Equipamento , Taxa Respiratória
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa