Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
J Vasc Surg ; 67(2): 637-644.e30, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-29389426

RESUMO

OBJECTIVE: The current state of evaluating patients with peripheral artery disease and more specifically of evaluating medical devices used for peripheral vascular intervention (PVI) remains challenging because of the heterogeneity of the disease process, the multiple physician specialties that perform PVI, the multitude of devices available to treat peripheral artery disease, and the lack of consensus about the best treatment approaches. Because PVI core data elements are not standardized across clinical care, clinical trials, and registries, aggregation of data across different data sources and physician specialties is currently not feasible. METHODS: Under the auspices of the U.S. Food and Drug Administration's Medical Device Epidemiology Network initiative-and its PASSION (Predictable and Sustainable Implementation of the National Registries) program, in conjunction with other efforts to align clinical data standards-the Registry Assessment of Peripheral Interventional Devices (RAPID) workgroup was convened. RAPID is a collaborative, multidisciplinary effort to develop a consensus lexicon and to promote interoperability across clinical care, clinical trials, and national and international registries of PVI. RESULTS: The current manuscript presents the initial work from RAPID to standardize clinical data elements and definitions, to establish a framework within electronic health records and health information technology procedural reporting systems, and to implement an informatics-based approach to promote the conduct of pragmatic clinical trials and registry efforts in PVI. CONCLUSIONS: Ultimately, we hope this work will facilitate and improve device evaluation and surveillance for patients, clinicians, health outcomes researchers, industry, policymakers, and regulators.


Assuntos
Prótese Vascular , Aprovação de Equipamentos/normas , Procedimentos Endovasculares/instrumentação , Doença Arterial Periférica/terapia , Sistema de Registros/normas , Stents , United States Food and Drug Administration/normas , Procedimentos Cirúrgicos Vasculares/instrumentação , Mineração de Dados/normas , Registros Eletrônicos de Saúde/normas , Procedimentos Endovasculares/efeitos adversos , Humanos , Cooperação Internacional , Informática Médica/normas , Doença Arterial Periférica/diagnóstico , Doença Arterial Periférica/fisiopatologia , Vigilância de Produtos Comercializados/normas , Desenho de Prótese , Ensaios Clínicos Controlados Aleatórios como Assunto/normas , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Estados Unidos/epidemiologia , Procedimentos Cirúrgicos Vasculares/efeitos adversos , Fluxo de Trabalho
2.
Circ J ; 82(2): 316-322, 2018 01 25.
Artigo em Inglês | MEDLINE | ID: mdl-29367497

RESUMO

BACKGROUND: The current state of evaluating patients with peripheral artery disease and more specifically of evaluating medical devices used for peripheral vascular intervention (PVI) remains challenging because of the heterogeneity of the disease process, the multiple physician specialties that perform PVI, the multitude of devices available to treat peripheral artery disease, and the lack of consensus about the best treatment approaches. Because PVI core data elements are not standardized across clinical care, clinical trials, and registries, aggregation of data across different data sources and physician specialties is currently not feasible.Methods and Results:Under the auspices of the U.S. Food and Drug Administration's Medical Device Epidemiology Network initiative-and its PASSION (Predictable and Sustainable Implementation of the National Registries) program, in conjunction with other efforts to align clinical data standards-the Registry Assessment of Peripheral Interventional Devices (RAPID) workgroup was convened. RAPID is a collaborative, multidisciplinary effort to develop a consensus lexicon and to promote interoperability across clinical care, clinical trials, and national and international registries of PVI. The current manuscript presents the initial work from RAPID to standardize clinical data elements and definitions, to establish a framework within electronic health records and health information technology procedural reporting systems, and to implement an informatics-based approach to promote the conduct of pragmatic clinical trials and registry efforts in PVI. CONCLUSIONS: Ultimately, we hope this work will facilitate and improve device evaluation and surveillance for patients, clinicians, health outcomes researchers, industry, policymakers, and regulators.


Assuntos
Equipamentos e Provisões/normas , Doença Arterial Periférica , Sistema de Registros/normas , Monitoramento Epidemiológico , Humanos , Doença Arterial Periférica/diagnóstico , Doença Arterial Periférica/terapia , Padrões de Referência
3.
J Vasc Surg ; 54(2): 394-401, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21658885

RESUMO

BACKGROUND: A novel self-expanding drug-eluting stent was designed to slowly release everolimus to prevent restenosis following peripheral arterial intervention. The purpose of the first-in-human Superficial Femoral Artery Treatment with Drug-Eluting Stents (STRIDES) trial was to evaluate the safety and efficacy of this device for the treatment of symptomatic superficial femoral and proximal popliteal arterial occlusive disease. METHODS AND RESULTS: One hundred four patients were enrolled at 11 European investigative centers in a prospective, nonrandomized, single-arm trial. The patients had severe symptomatic vascular disease, including a significant proportion of patients with critical limb ischemia (17%), diabetes (39%), and single-vessel outflow (26%). The mean lesion length was 9.0 ± 4.3 cm. Ninety-nine percent of patients were available for 12-month follow-up, including duplex imaging in 90% and arteriography in 83%. Clinical improvement, defined as a sustained decrease in Rutherford-Becker clinical category, was achieved in 80% of patients. Primary patency (freedom from ≥50% in-stent restenosis) was 94 ± 2.3% and 68 ± 4.6% at 6 and 12 months, respectively. Plain radiographic examination of 122 implanted devices at 12 months revealed no evidence for stent fracture. CONCLUSIONS: The everolimus-eluting self-expanding nitinol stent can be successfully implanted in patients with severe peripheral arterial disease with favorable outcomes and clinical improvements observed in the majority of patients.


Assuntos
Angioplastia/instrumentação , Fármacos Cardiovasculares/administração & dosagem , Stents Farmacológicos , Artéria Femoral , Doença Arterial Periférica/terapia , Artéria Poplítea , Sirolimo/análogos & derivados , Idoso , Angioplastia/efeitos adversos , Índice Tornozelo-Braço , Constrição Patológica , Europa (Continente) , Everolimo , Feminino , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/fisiopatologia , Humanos , Estimativa de Kaplan-Meier , Salvamento de Membro , Masculino , Pessoa de Meia-Idade , Doença Arterial Periférica/diagnóstico , Doença Arterial Periférica/fisiopatologia , Artéria Poplítea/diagnóstico por imagem , Artéria Poplítea/fisiopatologia , Estudos Prospectivos , Desenho de Prótese , Radiografia , Índice de Gravidade de Doença , Sirolimo/administração & dosagem , Fatores de Tempo , Resultado do Tratamento , Ultrassonografia Doppler Dupla , Grau de Desobstrução Vascular
4.
Am J Cardiol ; 99(10): 1403-8, 2007 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-17493469

RESUMO

The ZoMaxx Coronary Stent System elutes the antiproliferative agent zotarolimus via a biocompatible phosphorylcholine polymer loaded onto a novel, thin, stainless steel stent platform containing an 0.0007-inch inner layer of tantalum that enhances fluoroscopic radiopacity. The objective of this single-arm prospective clinical trial was to assess the safety and performance of the ZoMaxx stent for the treatment of coronary artery stenosis. Forty consecutive patients with ischemic coronary occlusive disease due to single de novo obstructive lesions of native coronary arteries were treated with 3 x 18 mm ZoMaxx stents at the Dante Pazzanese de Cardiologie in Saõ Paulo, Brazil, between April and July 2005. Independent core laboratories analyzed quantitative coronary angiography and intravascular ultrasound results immediately after stent implantation, and after 4 months. The lesion, procedure, and device-deployment success rates were all 100% (40 of 40). There were no major adverse cardiac events during the study. Follow-up quantitative coronary angiography at 4 months revealed in-stent and in-segment late lumen losses of 0.20 +/- 0.35 and 0.17 +/- 0.35 mm, respectively. Follow-up intravascular ultrasound at 4 months revealed 6.5 +/- 6.2% neointimal volume obstruction. There were no instances of late acquired stent incomplete apposition or stent thrombosis. In conclusion, the ZoMaxx Coronary Stent can be safely implanted for the treatment of de novo coronary artery stenosis. The inhibition of neointima formation as measured by follow-up angiography and IVUS after 4 months suggests therapeutic potential for the reduction of restenosis.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Fármacos Cardiovasculares/uso terapêutico , Estenose Coronária/terapia , Fosforilcolina/uso terapêutico , Sirolimo/análogos & derivados , Stents , Idoso , Implante de Prótese Vascular , Angiografia Coronária , Circulação Coronária , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/etiologia , Estenose Coronária/diagnóstico por imagem , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Desenho de Prótese , Projetos de Pesquisa , Sirolimo/química , Sirolimo/farmacologia , Sirolimo/uso terapêutico , Resultado do Tratamento , Túnica Íntima/diagnóstico por imagem , Túnica Íntima/fisiopatologia , Ultrassonografia de Intervenção
5.
Am. j. cardiol ; 99(10): 1403-1408, May 2007. ilus
Artigo em Inglês | SES-SP, SES SP - Instituto Dante Pazzanese de Cardiologia, SES-SP | ID: biblio-1059491

RESUMO

The ZoMaxx Coronary Stent System elutes the antiproliferative agent zotarolimus via a biocompatible phosphorylcholine polymer loaded onto a novel, thin, stainless steel stent platform containing an 0.0007-inch inner layer of tantalum that enhances fluoroscopic radiopacity. The objective of this single-arm prospective clinical trial was to assess the safety and performance of the ZoMaxx stent for the treatment of coronary artery stenosis. Forty consecutive patients with ischemic coronary occlusive disease due to single de novo obstructive lesions of native coronary arteries were treated with 3 x 18 mm ZoMaxx stents at the Dante Pazzanese de Cardiologie in Saõ Paulo, Brazil, between April and July 2005. Independent core laboratories analyzed quantitative coronary angiography and intravascular ultrasound results immediately after stent implantation, and after 4 months. The lesion, procedure, and device-deployment success rates were all 100% (40 of 40). There were no major adverse cardiac events during the study. Follow-up quantitative coronary angiography at 4 months revealed in-stent and in-segment late lumen losses of 0.20 +/- 0.35 and 0.17 +/- 0.35 mm, respectively. Follow-up intravascular ultrasound at 4 months revealed 6.5 +/- 6.2% neointimal volume obstruction. There were no instances of late acquired stent incomplete apposition or stent thrombosis. In conclusion, the ZoMaxx Coronary Stent can be safely implanted for the treatment of de novo coronary artery stenosis. The inhibition of neointima formation as measured by follow-up angiography and IVUS after 4 months suggests therapeutic potential for the reduction of restenosis.


Assuntos
Angiografia Coronária , Angioplastia Coronária com Balão/instrumentação , Cardiotônicos/uso terapêutico , Circulação Coronária , Desenho de Prótese , Fosforilcolina/uso terapêutico , Implante de Prótese Vascular , Projetos de Pesquisa Epidemiológica , Reestenose Coronária , Reestenose Coronária/etiologia , Sirolimo/análogos & derivados , Sirolimo/farmacologia , Sirolimo/química , Sirolimo/uso terapêutico , Stents , Túnica Íntima , Túnica Íntima/fisiopatologia
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa