Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
ACS Omega ; 7(42): 37122-37132, 2022 Oct 25.
Artigo em Inglês | MEDLINE | ID: mdl-36312398

RESUMO

Here we report the design and fabrication of an array-based sensor, containing functionalized Carbon Dots, Bodipy's and Naphthalimide probes, that shows high fluorescence emissions and sensitivity in the presence of low amounts of TNT explosive. In particular, we have fabricated the first sensor device based on an optical array for the detection of TNT in real samples by using a smartphone as detector. The possibility to use a common smartphone as detector leads to a prototype that can be also used in a real-life field application. The key benefit lies in the possibility of even a nonspecialist operator in the field to simply collect and send data (photos) to the trained artificial intelligence server for rapid diagnosis but also directly to the bomb disposal unit for expert evaluation. This new array sensor contains seven different fluorescent probes that are able to interact via noncovalent interactions with TNT. The interaction of each probe with TNT has been tested in solution by fluorescence titrations. The solid device has been tested in terms of selectivity and linearity toward TNT concentration. Tests performed with other explosives and other nitrogen-based analytes demonstrate the high selectivity for TNT molecules, thus supporting the reliability of this sensor. In addition, TNT can be detected in the range of 98 ng∼985 µg, with a clear different response of each probe to the different amounts of TNT.

2.
Forensic Sci Int ; 167(2-3): 163-6, 2007 Apr 11.
Artigo em Inglês | MEDLINE | ID: mdl-16887309

RESUMO

A serious problem in questioned document examination is to establish the age of written lines. With respect to paper dating, in the past, Max Frei theory (based only on microscope analysis) claimed that strokes are time-dependent. Therefore, according to this theory, it has been asserted that from the analysis of the strokes depth changes it is possible to try to date the handwritten document (to find out that the document is older than ...). In the present work, we investigate the strokes depth change by a laser profilometer considering not only the time but also microclimatic variations. First, we analyze the stability of stroke characteristics along the time. In particular, we demonstrate that if the document is preserved without change of temperature and humidity, the depth of the strokes has not appreciable changes. In this way, we have the purpose to verify the real possibility of documents dating by means of Max Frei theory. Subsequently, we test how the 3D profile of strokes changes in connection with the microclimatic variations. In particular, we test humidity variations. With this experiment, we show that humidity variations reduce the strokes depth. Moreover, this effect shows a non-linear trend, leaving a hysteresis on the depth. Finally, we show that the analysis of 3D stroke profile is unable to determine the age of documents.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa