Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Expert Opin Drug Deliv ; 19(7): 815-832, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35738312

RESUMO

INTRODUCTION: Triple-negative breast cancer (TNBC) is a subtype of severely aggressive breast cancer that lacks the expression of oestrogen receptor (ER), progesterone receptor and human epidermal growth factor receptor 2 (HER2) and is highly metastatic and related to a poor prognosis. Current standard treatments are still limited to systemic chemotherapy, radiotherapy, and surgical resection. More effective treatments are urgently needed. AREAS COVERED: The immunogenicity of TNBC has provided opportunities for the development of targeted immunotherapy. In this review, we focus on the recent development in antibody-based drug modalities, including angiogenesis inhibitors, immune checkpoint inhibitors, antibody-drug conjugates, immunoconjugates, T cell-redirecting bispecific antibodies and CAR-T cells, and their mechanisms of action in TNBC. EXPERT OPINION: At present, the treatment of TNBC is still a major challenge that needs to be addressed. Novel immunotherapies are promising opportunities for improving the management of this aggressive disease.


Assuntos
Imunoconjugados , Neoplasias de Mama Triplo Negativas , Inibidores da Angiogênese , Humanos , Imunoconjugados/uso terapêutico , Imunoterapia , Neoplasias de Mama Triplo Negativas/tratamento farmacológico , Neoplasias de Mama Triplo Negativas/metabolismo
2.
Artigo em Inglês | MEDLINE | ID: mdl-33370238

RESUMO

The ultrasound (US) imaging technique has been applied to scoliosis assessment, and the proxy Cobb angle can be acquired on the US coronal images. The spinous process angle (SPA) is a valuable parameter to indicate 3-D deformity of spine. However, the SPA cannot be measured on US images since the spinous process (SP) is merged in the soft tissue layer and impossible to be identified on the coronal view directly. A new method based on the gradient vector flow (GVF) snake model was proposed to automatically locate SP position on the US transverse images, and the density-based spatial clustering of application with noise (DBSCAN) was used to remove the outliers out of the detected location results. With marking the SP points on the US coronal image, the SP curve was interpolated and the SPA was measured. The algorithm was evaluated on 50 subjects with various severity of scoliosis, and two raters measured the SPA on both US images and radiographs manually. The mean absolute differences (MADs) of SPAs obtained from the two modalities were 3.4° ± 2.4° and 3.6° ± 2.8° for the two raters, respectively, which were less than the clinical acceptance error (5°), and the results reported a good linear correlation ( ) between the US method and radiography. It indicates that the proposed method can be a promising approach for SPA measurement using the US imaging technique.


Assuntos
Escoliose , Coluna Vertebral , Algoritmos , Humanos , Radiografia , Escoliose/diagnóstico por imagem , Coluna Vertebral/diagnóstico por imagem , Ultrassonografia
3.
Artigo em Inglês | MEDLINE | ID: mdl-34106851

RESUMO

Three-dimensional (3-D) freehand ultrasound (US) imaging has been applied to the investigation of spine deformity. However, it is a challenge for the current 3-D imaging reconstruction algorithms to achieve a balance between image quality and computation time. The objectives of this article are to implement a new fast reconstruction algorithm that can fulfill the request of immediate demonstration and processing for high-quality 3-D spine imaging, and to evaluate the reliability and accuracy of scoliotic curvature measurement when using the algorithm. The fast dot-projection (FDP) algorithm was applied for voxel-based nearest neighbor (VNN), multiple plane interpolation (MPI), and pixel nearest neighbor (PNN) protocols to reduce the reconstruction time. The 3-D image volume was reconstructed from the datasets acquired from scoliotic subjects. The computational cost, image characteristics, and statistical analyses of curve measurements were compared and evaluated among different reconstruction protocols. The results illustrated that the 3-D spine images using the FDP-MPI4 algorithm showed higher brightness (20%), contrast (14%), and signal-to-noise ratio (SNR) (26%) than FDP-VNN. The measurement performed by trainee rater exhibited significant improvement in measurement reliability and accuracy using FDP-MPI4 in comparison with FDP-VNN ( ), and the intraclass correlation coefficient (ICC) of interrater measurement increased from 0.88 to 0.96. The FDP-PNN method could acquire and reconstruct spine images simultaneously and present the results in 1-2 min, which showed the potential to provide the approximate real-time visualization for fast screening.


Assuntos
Algoritmos , Imageamento Tridimensional , Humanos , Processamento de Imagem Assistida por Computador , Imagens de Fantasmas , Reprodutibilidade dos Testes , Coluna Vertebral/diagnóstico por imagem , Ultrassonografia
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa