Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Molecules ; 25(4)2020 Feb 18.
Artigo em Inglês | MEDLINE | ID: mdl-32085411

RESUMO

In this study, a novel monolithic capillary column based on a NH2-MIL-53(Al) metal-organic framework (MOF) incorporated in poly (3-acrylamidophenylboronic acid/methacrylic acid-co-ethylene glycol dimethacrylate) (poly (AAPBA/MAA-co-EGDMA)) was prepared using an in situ polymerization method. The characteristics of the MOF-polymer monolithic column were investigated by scanning electron microscopy, Fourier-transform infrared spectroscopy, X-ray photoelectron spectroscopy, X-ray diffractometry, Brunauer-Emmett-Teller analysis, and thermogravimetric analysis. The prepared MOF-polymer monolithic column showed good permeability, high extraction efficiency, chemical stability, and good reproducibility. The MOF-polymer monolithic column was used for in-tube solid-phase microextraction (SPME) to efficiently adsorb trace sulfonamides from food samples. A novel method combining MOF-polymer-monolithic-column-based SPME with ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) was successfully developed. The linear range was from 0.015 to 25.0 µg/L, with low limits of detection of 1.3-4.7 ng/L and relative standard deviations (RSDs) of < 6.1%. Eight trace sulfonamides in fish and chicken samples were determined, with recoveries of the eight analytes ranging from 85.7% to 113% and acceptable RSDs of < 7.3%. These results demonstrate that the novel MOF-polymer-monolithic-column-based SPME coupled with UHPLC-MS/MS is a highly sensitive, practical, and convenient method for monitoring trace sulfonamides in food samples previously extracted with an adequate solvent.


Assuntos
Análise de Alimentos , Polímeros/química , Microextração em Fase Sólida , Sulfonamidas/análise , Espectrometria de Massas em Tandem , Adsorção , Animais , Calibragem , Galinhas , Cromatografia Líquida de Alta Pressão , Peixes , Concentração de Íons de Hidrogênio , Estruturas Metalorgânicas , Reologia , Espectroscopia de Infravermelho com Transformada de Fourier , Temperatura , Difração de Raios X
2.
Molecules ; 24(23)2019 Nov 23.
Artigo em Inglês | MEDLINE | ID: mdl-31771216

RESUMO

In this work, we successfully developed a novel and sensitive gas sensor for the determination of trace acetophenone based on its cataluminescence (CTL) emission on the surface of nano-praseodymium oxide (nano-Pr6O11). The effects of working conditions such as temperature, flow rate, and detecting wavelength on the CTL sensing were investigated in detail. Under the optimized conditions, the sensor exhibited linear response to the acetophenone in the range of 15-280 mg/m3 (2.8-52 ppm), with a correlation coefficient (R2) of 0.9968 and a limit of detection (S/N = 3) of 4 mg/m3 (0.7 ppm). The selectivity of the sensor was also investigated, no or weak response to other compounds, such as alcohols (methanol, ethanol, n-propanol, iso-propanol, n-butanol), aldehyde (formaldehyde and acetaldehyde), benzenes (toluene, o-xylene, m-xylene, p-xylene), n-pentane, ethyl acetate, ammonia, carbon monoxide, carbon dioxide. Finally, the present sensor was applied to the determination of acetophenone in human exhaled breath samples. The results showed that the sensor has promising application in clinical breath analysis.


Assuntos
Acetofenonas/análise , Neoplasias da Mama/diagnóstico , Óxidos/síntese química , Praseodímio/química , Técnicas Biossensoriais , Neoplasias da Mama/química , Testes Respiratórios , Catálise , Feminino , Humanos , Luminescência , Nanopartículas/química , Óxidos/química , Propriedades de Superfície
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa