RESUMO
AIMS: Catheter ablation (CA) of ventricular tachycardia (VT) has become an important tool to improve clinical outcomes in patients with appropriate transvenous implantable cardioverter defibrillator (ICD) shocks. The aim of our analysis was to test whether VT ablation (VTA) impacts long-term clinical outcomes even in subcutaneous ICD (S-ICD) carriers. METHODS AND RESULTS: International Subcutaneous Implantable Cardioverter Defibrillator (iSUSI) registry patients who experienced either an ICD shock or a hospitalization for monomorphic VT were included in this analysis. Based on an eventual VTA after the index event, patients were divided into VTA+ vs. VTA- cohorts. Primary outcome of the study was the occurrence of a combination of device-related appropriate shocks, monomorphic VTs, and cardiovascular mortality. Secondary outcomes were addressed individually. Among n = 1661 iSUSI patients, n = 211 were included: n = 177 experiencing ICD shocks and n = 34 hospitalized for VT. No significant differences in baseline characteristics were observed. Both the crude and the yearly event rate of the primary outcome (5/59 and 3.8% yearly event rate VTA+ vs. 41/152 and 16.4% yearly event rate in the VTA-; log-rank: P value = 0.0013) and the cardiovascular mortality (1/59 and 0.7% yearly event rate VTA+ vs. 13/152 and 4.7% yearly event rate VTA-; log-rank P = 0.043) were significantly lower in the VTA + cohort. At multivariate analysis, VTA was the only variable remaining associated with a lower incidence of the primary outcome [adjusted hazard ratio 0.262 (0.100-0.681), P = 0.006]. CONCLUSION: In a real-world registry of S-ICD carriers, the combined study endpoint of arrhythmic events and cardiovascular mortality was lower in the patient cohort undergoing VTA at long-term follow-up. CLINICALTRIALS.GOV IDENTIFIER: NCT0473876.
Assuntos
Ablação por Cateter , Desfibriladores Implantáveis , Taquicardia Ventricular , Humanos , Arritmias Cardíacas/etiologia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Cardioversão Elétrica/efeitos adversos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirurgia , Resultado do TratamentoRESUMO
INTRODUCTION: Regardless of the catheter ablation (CA) for atrial fibrillation (AF) strategy, the role of early recurrences during the blanking period (BP) is still unclear. Our aim was to evaluate atrial tachyarrhythmias (ATAs) recurrences during the BP after CA with the laser-balloon (LB) technique. METHODS: Consecutive patients undergoing LBCA were enrolled. Primary outcome of the study was the overall crude ATA recurrence rate during the BP. ATA recurrences after the BP and in-hospital readmissions during the BP were deemed secondary outcomes. RESULTS: Two hundred and twenty-four patients underwent CA with the LB. Median age was 63.0 (55.5-69.5) years and 74.1% were males. 28.6% were persistent AF patients, and 34.8% of patients were followed up with a loop recorder. 15.6% of patients experienced at least an ATA recurrence during the BP. Male sex, chronic heart failure, persistent AF, and recurrences during the BP were found to be associated with long-term ATA recurrences. Recurrences during the BP remained associated with the outcome of interest at multivariate analysis (hazard ratio [HR] = 12.393, 95% confidence interval [95% CI] = 3.699-41.865, p < .001). An association over time was found between early and late recurrences, with 73.7%, 45.5%, and 10.8% of patients presenting with recurrences at 1-, 2-, and 3-month follow-up being free from recurrences after the BP, respectively. 8.0% of patients were readmitted during the BP: 4.5% for AF electrical cardioversion, and 1.8% for CA of other atrial arrhythmias; no redo CA was performed. CONCLUSION: After adjusting for confounders, ATA recurrences during the BP represent the most significant predictor of ATA recurrences after the BP, regardless of AF pattern.
Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Masculino , Pessoa de Meia-Idade , Feminino , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Resultado do Tratamento , Fatores de Tempo , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Recidiva , Veias Pulmonares/cirurgia , LasersRESUMO
INTRODUCTION: The prediction of ventricular tachyarrhythmias among patients with implantable cardioverter defibrillators is difficult with available clinical tools. We sought to assess whether in patients with heart failure (HF) and reduced ejection fraction with defibrillators, physiological sensor-based HF status, as summarized by the HeartLogic index, could predict appropriate device therapies. METHODS: Five hundred and sixty-eight consecutive HF patients with defibrillators (n = 158, 28%) or cardiac resynchronization therapy-defibrillators (n = 410, 72%) were included in this prospective observational multicenter analysis. The association of both HeartLogic index and its physiological components with defibrillator shocks and overall appropriate therapies was assessed in regression and time-dependent Cox models. RESULTS: Over a follow-up of 25 (15-35) months, 122 (21%) patients received an appropriate device therapy (shock, n = 74, 13%), while the HeartLogic index crossed the threshold value (alert, HeartLogic ≥ 16) 1200 times (0.71 alerts/patient-year) in 370 (65%) subjects. The occurrence of ≥1 HeartLogic alert was significantly associated with both appropriate shocks (Hazard ratios [HR]: 2.44, 95% confidence interval [CI]: 1.49-3.97, p = .003), and any appropriate defibrillator therapies. In multivariable time-dependent Cox models, weekly IN-alert state was the strongest predictor of appropriate defibrillator shocks (HR: 2.94, 95% CI: 1.73-5.01, p < .001) and overall therapies. Compared with stable patients, patients with appropriate shocks had significantly higher values of HeartLogic index, third heart sound amplitude, and resting heart rate 30-60 days before device therapy. CONCLUSION: The HeartLogic index is an independent dynamic predictor of appropriate defibrillator therapies. The combined index and its individual physiological components change before the arrhythmic event occurs.
Assuntos
Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Insuficiência Cardíaca , Taquicardia Ventricular , Disfunção Ventricular Esquerda , Humanos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/terapia , Taquicardia Ventricular/complicações , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/complicações , Terapia de Ressincronização Cardíaca/efeitos adversos , Disfunção Ventricular Esquerda/terapiaRESUMO
AIMS: In patients with prolonged atrioventricular (AV) conduction and pacemaker (PM) indication due to sinus node disease (SND) or intermittent AV-block who do not need continuous ventricular pacing (VP), it may be difficult to determine which strategy to adopt. Currently, the standard of care is to minimize unnecessary VP by specific VP avoidance (VPA) algorithms. The superiority of this strategy over standard DDD or DDD rate-responsive (DDD/DDDR) in improving clinical outcomes is controversial, probably owing to the prolongation of the atrialventricular conduction (PR interval) caused by the algorithms. Conduction system pacing (CSP) may offer the most physiological-VP approach, providing appropriate AV conduction and preventing pacing-induced dyssynchrony. METHODS AND RESULTS: PhysioVP-AF is a prospective, controlled, randomized, single-blind trial designed to determine whether atrial-synchronized conduction system pacing (DDD-CSP) is superior to standard DDD-VPA pacing in terms of 3-year reduction of persistent-AF occurrence. Cardiovascular hospitalization, quality-of-life, and safety will be evaluated. Patients with indication for permanent DDD pacing for SND or intermittent AV-block and prolonged AV conduction (PR interval > 180â ms) will be randomized (1:1 ratio) to DDD-VPA (VPA-algorithms ON, septal/apex position) or to DDD-CSP (His bundle or left bundle branch area pacing, AV-delay setting to control PR interval, VPA-algorithms OFF). Approximately 400 patients will be randomized in 24 months in 13 Italian centres. CONCLUSION: The PhysioVP-AF study will provide an essential contribution to patient management with prolonged AV conduction and PM indication for sinus nodal disease or paroxysmal 2nd-degree AV-block by determining whether CSP combined with a controlled PR interval is superior to standard management that minimizes unnecessary VP in terms of reducing clinical outcomes.
Assuntos
Fibrilação Atrial , Bloqueio Atrioventricular , Marca-Passo Artificial , Humanos , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/terapia , Estimulação Cardíaca Artificial/efeitos adversos , Estimulação Cardíaca Artificial/métodos , Estudos Prospectivos , Método Simples-Cego , Síndrome do Nó Sinusal/complicações , Síndrome do Nó Sinusal/diagnóstico , Síndrome do Nó Sinusal/terapiaRESUMO
AIMS: Infections resulting from cardiac implantable electronic device (CIED) implantation are severely impacting on patients' and on health care systems. The use of TYRXTM absorbable antibiotic-eluting envelope has proven to decrease major CIED infections within 12 months of CIED surgery. The aim is to evaluate the impact of the envelope use on infection-related clinical events in a real-world contemporary patient population. METHODS AND RESULTS: Data on patients undergoing CIED surgery were collected prospectively by participating centers of the One Hospital ClinicalService project. Patients were divided into two groups according to whether TYRXTM absorbable antibiotic-eluting envelope was used or not. Out of 1819 patients, 872 (47.9%) were implanted with an absorbable antibiotic-eluting envelope and included in the Envelope group and 947 (52.1%) patients who did not receive an envelope were included in the Control group. Compared to control, patients in the Envelope group had higher thrombo-embolic or hemorrhagic risk, higher BMI, lower LVEF and more comorbidities. During a mean follow-up of 1.4 years, the incidence of infection-related events was significantly higher in the control compared to the Envelope group (2.4% vs. 0.8%, P = 0.007). The five-year cumulative incidence of infection-related events was 8.1% in the control and 2.1% in the Envelope group (HR: 0.34, 95%CI: 0.14-0.80, P = 0.010). CONCLUSION: In our analysis, the use of an absorbable antibiotic-eluting envelope in the general CIED population was associated with a lower risk of systemic and pocket infection.
Assuntos
Desfibriladores Implantáveis , Cardiopatias , Marca-Passo Artificial , Infecções Relacionadas à Prótese , Humanos , Desfibriladores Implantáveis/efeitos adversos , Marca-Passo Artificial/efeitos adversos , Antibacterianos/uso terapêutico , Causalidade , Cardiopatias/complicações , Infecções Relacionadas à Prótese/diagnóstico , Infecções Relacionadas à Prótese/epidemiologia , Infecções Relacionadas à Prótese/prevenção & controleRESUMO
AIMS: The safety and efficacy of leadless intracardiac-permanent pacemaker (L-PM) have been demonstrated in multiple clinical trials, but data on comparisons with conventional transvenous-permanent pacemaker (T-PM) collected in a consecutive, prospective fashion are limited. The aim of this analysis was to compare the rate and the nature of device-related complications between patients undergoing L-PM vs. T-PM implantation. METHODS AND RESULTS: Prospective, multicentre, observational project enrolling consecutive patients who underwent L-PM or T-PM implantation. The rate and nature of device-related complications were analysed and compared between the two groups. Individual 1:1 propensity matching of baseline characteristics was performed. A total of 2669 (n = 665 L-PM) patients were included and followed for a median of 39 months, L-PM patients were on average older and had more co-morbidities. The risk of device-related complications at 12 months was significantly lower in the L-PM group (0.5% vs. 1.9%, P = 0.009). Propensity matching yielded 442 matched pairs. In the matched cohort, L-PM patients trended toward having a lower risk of overall device-related complications (P = 0.129), had a similar risk of early complications (≤30 days) (P = 1.000), and had a significantly lower risk of late complications (>30 days) (P = 0.031). All complications observed in L-PM group were early. Most (75.0%) of complications observed in T-PM group were lead- or pocket-related. CONCLUSION: In this analysis, the risk of device-related complications associated with L-PM implantation tended to be lower than that of T-PM. Specifically, the risk of early complications was similar in two types of PMs, while the risk of late complications was significantly lower for L-PM than T-PM.
Assuntos
Arritmias Cardíacas , Marca-Passo Artificial , Humanos , Resultado do Tratamento , Desenho de Equipamento , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/terapia , Arritmias Cardíacas/etiologia , Marca-Passo Artificial/efeitos adversos , Fatores de TempoRESUMO
AIMS: Patients with atrial fibrillation frequently experience sleep disorder breathing, and both conditions are highly prevalent in presence of heart failure (HF). We explored the association between the combination of an HF and a sleep apnoea (SA) index and the incidence of atrial high-rate events (AHRE) in patients with implantable defibrillators (ICDs). METHODS AND RESULTS: Data were prospectively collected from 411 consecutive HF patients with ICD. The IN-alert HF state was measured by the multi-sensor HeartLogic Index (>16), and the ICD-measured Respiratory Disturbance Index (RDI) was computed to identify severe SA. The endpoints were as follows: daily AHRE burden of ≥5 min, ≥6 h, and ≥23 h. During a median follow-up of 26 months, the time IN-alert HF state was 13% of the total observation period. The RDI value was ≥30 episodes/h (severe SA) during 58% of the observation period. An AHRE burden of ≥5 min/day was documented in 139 (34%) patients, ≥6 h/day in 89 (22%) patients, and ≥23 h/day in 68 (17%) patients. The IN-alert HF state was independently associated with AHRE regardless of the daily burden threshold: hazard ratios from 2.17 for ≥5 min/day to 3.43 for ≥23 h/day (P < 0.01). An RDI ≥ 30 episodes/h was associated only with AHRE burden ≥5 min/day [hazard ratio 1.55 (95% confidence interval: 1.11-2.16), P = 0.001]. The combination of IN-alert HF state and RDI ≥ 30 episodes/h accounted for only 6% of the follow-up period and was associated with high rates of AHRE occurrence (from 28 events/100 patient-years for AHRE burden ≥5 min/day to 22 events/100 patient-years for AHRE burden ≥23 h/day). CONCLUSIONS: In HF patients, the occurrence of AHRE is independently associated with the ICD-measured IN-alert HF state and RDI ≥ 30 episodes/h. The coexistence of these two conditions occurs rarely but is associated with a very high rate of AHRE occurrence. CLINICAL TRIAL REGISTRATION: URL: http://clinicaltrials.gov/Identifier: NCT02275637.
Assuntos
Fibrilação Atrial , Desfibriladores Implantáveis , Insuficiência Cardíaca , Síndromes da Apneia do Sono , Humanos , Desfibriladores Implantáveis/efeitos adversos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/terapia , Medição de Risco , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/epidemiologia , Insuficiência Cardíaca/terapiaRESUMO
AIMS: A previous randomized study demonstrated that the subcutaneous implantable cardioverter defibrillator (S-ICD) was noninferior to transvenous ICD with respect to device-related complications and inappropriate shocks. However, that was performed prior to the widespread adoption of pulse generator implantation in the intermuscular (IM) space instead of the traditional subcutaneous (SC) pocket. The aim of this analysis was to compare survival from device-related complications and inappropriate shocks between patients who underwent S-ICD implantation with the generator positioned in an IM position in comparison with an SC pocket. METHODS AND RESULTS: We analysed 1577 consecutive patients who had undergone S-ICD implantation from 2013 to 2021 and were followed up until December 2021. Subcutaneous patients (n = 290) were propensity matched with patients of the IM group (n = 290), and their outcomes were compared. : During a median follow-up of 28 months, device-related complications were reported in 28 (4.8%) patients and inappropriate shocks were reported in 37 (6.4%) patients. The risk of complication was lower in the matched IM group than in the SC group [hazard ratio 0.41, 95% confidence interval (CI) 0.17-0.99, P = 0.041], as well as the composite of complications and inappropriate shocks (hazard ratio 0.50, 95% CI 0.30-0.86, P = 0.013). The risk of appropriate shocks was similar between groups (hazard ratio 0.90, 95% CI 0.50-1.61, P = 0.721). There was no significant interaction between generator positioning and variables such as gender, age, body mass index, and ejection fraction. CONCLUSION: Our data showed the superiority of the IM S-ICD generator positioning in reducing device-related complications and inappropriate shocks. CLINICAL TRIAL REGISTRATION: Clinical Trial Registration: ClinicalTrials.gov; NCT02275637.
Assuntos
Desfibriladores Implantáveis , Humanos , Desfibriladores Implantáveis/efeitos adversos , Estudos de Casos e Controles , Morte Súbita Cardíaca/etiologia , Estudos Retrospectivos , Resultado do TratamentoRESUMO
AIMS: The HeartLogic Index combines data from multiple implantable cardioverter defibrillators (ICDs) sensors and has been shown to accurately stratify patients at risk of heart failure (HF) events. We evaluated and compared the performance of this algorithm during sinus rhythm and during long-lasting atrial fibrillation (AF). METHODS AND RESULTS: HeartLogic was activated in 568 ICD patients from 26 centres. We found periods of ≥30 consecutive days with an atrial high-rate episode (AHRE) burden <1â h/day and periods with an AHRE burden ≥20â h/day. We then identified patients who met both criteria during the follow-up (AHRE group, n = 53), to allow pairwise comparison of periods. For control purposes, we identified patients with an AHRE burden <1â h throughout their follow-up and implemented 2:1 propensity score matching vs. the AHRE group (matched non-AHRE group, n = 106). In the AHRE group, the rate of alerts was 1.2 [95% confidence interval (CI): 1.0-1.5]/patient-year during periods with an AHRE burden <1â h/day and 2.0 (95% CI: 1.5-2.6)/patient-year during periods with an AHRE-burden ≥20â h/day (P = 0.004). The rate of HF hospitalizations was 0.34 (95% CI: 0.15-0.69)/patient-year during IN-alert periods and 0.06 (95% CI: 0.02-0.14)/patient-year during OUT-of-alert periods (P < 0.001). The IN/OUT-of-alert state incidence rate ratio of HF hospitalizations was 8.59 (95% CI: 1.67-55.31) during periods with an AHRE burden <1â h/day and 2.70 (95% CI: 1.01-28.33) during periods with an AHRE burden ≥20â h/day. In the matched non-AHRE group, the rate of HF hospitalizations was 0.29 (95% CI: 0.12-0.60)/patient-year during IN-alert periods and 0.04 (95% CI: 0.02-0.08)/patient-year during OUT-of-alert periods (P < 0.001). The incidence rate ratio was 7.11 (95% CI: 2.19-22.44). CONCLUSION: Patients received more alerts during periods of AF. The ability of the algorithm to identify increased risk of HF events was confirmed during AF, despite a lower IN/OUT-of-alert incidence rate ratio in comparison with non-AF periods and non-AF patients. CLINICAL TRIAL REGISTRATION: http://clinicaltrials.gov/Identifier: NCT02275637.
Assuntos
Fibrilação Atrial , Desfibriladores Implantáveis , Insuficiência Cardíaca , Humanos , Algoritmos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/terapia , Átrios do Coração , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/epidemiologia , Insuficiência Cardíaca/terapiaRESUMO
AIMS: The implantable cardioverter-defibrillator (ICD) is a life-saving therapy in patients with hypertrophic cardiomyopathy (HCM) at risk of sudden cardiac death. Implantable cardioverter-defibrillator complications are of concern. The subcutaneous ICD (S-ICD) does not use transvenous leads and is expected to reduce complications. However, it does not provide bradycardia and anti-tachycardia pacing (ATP). The aim of this study was to compare appropriate and inappropriate ICD interventions, complications, disease-related adverse events and mortality between HCM patients implanted with a S- or transvenous (TV)-ICD. METHODS AND RESULTS: Consecutive HCM patients implanted with a S- (n = 216) or TV-ICD (n = 211) were enrolled. Propensity-adjusted cumulative Kaplan-Meier curves and multivariate Cox proportional hazard ratios were used to compare 5-year event-free survival and the risk of events. The S-ICD patients had lower 5-year risk of appropriate (HR: 0.32; 95%CI: 0.15-0.65; P = 0.002) and inappropriate (HR: 0.44; 95%CI: 0.20-0.95; P = 0.038) ICD interventions, driven by a high incidence of ATP therapy in the TV-ICD group. The S- and TV-ICD patients experienced similar 5-year rate of device-related complications, albeit the risk of major lead-related complications was lower in S-ICD patients (HR: 0.17; 95%CI: 0.038-0.79; P = 0.023). The TV- and S-ICD patients displayed similar risk of disease-related complications (HR: 0.64; 95%CI: 0.27-1.52; P = 0.309) and mortality (HR: 0.74; 95%CI: 0.29-1.87; P = 0.521). CONCLUSION: Hypertrophic cardiomyopathy patients implanted with a S-ICD had lower 5-year risk of appropriate and inappropriate ICD therapies as well as of major lead-related complications as compared to those implanted with a TV-ICD. Long-term comparative follow-up studies will clarify whether the lower incidence of major lead-related complications will translate into a morbidity or survival benefit.
Assuntos
Cardiomiopatia Hipertrófica , Desfibriladores Implantáveis , Humanos , Cardiomiopatia Hipertrófica/complicações , Cardiomiopatia Hipertrófica/terapia , Bradicardia , Progressão da Doença , Trifosfato de AdenosinaRESUMO
AIMS: Subcutaneous implantable cardioverter-defibrillator (S-ICD) therapy is expanding rapidly. However, there are few data on the S-ICD extraction procedure and subsequent patient management. The aim of this analysis was to describe the procedure, management, and outcome of S-ICD extractions in clinical practice. METHODS AND RESULTS: We enrolled consecutive patients who required complete S-ICD extraction at 66 Italian centres. From 2013 to 2022, 2718 patients undergoing de novo implantation of an S-ICD were enrolled. Of these, 71 required complete S-ICD system extraction (17 owing to infection). The S-ICD system was successfully extracted in all patients, and no complications were reported; the median procedure duration was 40 (25th-75th percentile: 20-55) min. Simple manual traction was sufficient to remove the lead in 59 (84%) patients, in whom lead-dwelling time was shorter [20 (9-32) months vs. 30 (22-41) months; P = 0.032]. Hospitalization time was short in the case of both non-infectious [2 (1-2) days] and infectious indications [3 (1-6) days]. In the case of infection, no patients required post-extraction intravenous antibiotics, the median duration of any antibiotic therapy was 10 (10-14) days, and the re-implantation was performed during the same procedure in 29% of cases. No complications arose over a median of 21 months. CONCLUSION: The S-ICD extraction was safe and easy to perform, with no complications. Simple traction of the lead was successful in most patients, but specific tools could be needed for systems implanted for a longer time. The peri- and post-procedural management of S-ICD extraction was free from complications and not burdensome for patients and healthcare system. CLINICAL TRIAL REGISTRATION: URL: http://clinicaltrials.gov/Identifier: NCT02275637.
Assuntos
Desfibriladores Implantáveis , Humanos , Administração Intravenosa , Antibacterianos , Hospitalização , Resultado do TratamentoRESUMO
BACKGROUND: Conduction system pacing (CSP), including His-bundle pacing (HBP) and left bundle branch area pacing (LBBAP), have been proposed as alternatives to biventricular pacing (BVP) in patients scheduled for ablate and pace (A&P) strategy. The aim of this study was to compare the clinical outcomes, including the rate and nature of device-related complications, between BVP and CSP in a cohort of patients undergoing A&P. METHODS: Prospective, multicenter, observational study, enrolling consecutive patients undergoing A&P. The risk of device-related complications and of heart failure (HF) hospitalization was prospectively assessed. RESULTS: A total of 373 patients (75.3 ± 8.7 years, 53.9% male, 68.9% with NYHA class ≥III) were enrolled: 263 with BVP, 68 with HBP, and 42 with LBBAP. Baseline characteristics of the three groups were similar. Compared to BVP and HBP, LBBAP was associated with the shortest mean procedural and fluoroscopy times and with the lowest acute capture thresholds (all p < .05). At 12-month follow-up LBBAP maintained the lowest capture thresholds and showed the longest estimated residual battery longevity (all p < .05). At 12-months follow-up the three study groups showed a similar risk of device-related complications (5.7%, 4.4%, and 2.4% for BVP, HBP, and LBBAP, respectively; p = .650), and of HF hospitalization (2.7%, 1.5%, and 2.4% for BVP, HBP, and LBBAP, respectively; p = .850). CONCLUSIONS: In the setting of A&P, CSP is a feasible pacing modality, with a midterm safety profile comparable to BVP. LBBAP offers the advantage of reducing procedural times and obtaining lower and stable capture thresholds, with a positive impact on the device longevity.
Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Humanos , Masculino , Feminino , Estudos Prospectivos , Sistema de Condução Cardíaco , Doença do Sistema de Condução Cardíaco , Fontes de Energia Elétrica , Insuficiência Cardíaca/terapia , Fascículo Atrioventricular , Resultado do Tratamento , Eletrocardiografia , Estimulação Cardíaca ArtificialRESUMO
INTRODUCTION: Left ventricular (LV) lead optimal positioning is one of the most important determinants of cardiac resynchronization therapy (CRT) success. LV quadripolar active fixation (QAF) leads have been designed to ensure stable LV pacing in the target area and reduce the likelihood of phrenic nerve stimulation (PNS). The aim of this analysis is to compare performances, safety, and clinical outcomes of QAF with those of quadripolar passive fixation leads (QPL) and bipolar active fixation (BAF) leads in a real-world cohort of CRT patients. METHODS AND RESULTS: This retrospective analysis compared the procedure and follow-up data of 117 QAF included in the One Hospital ClinicalService project from nine Italian hospitals with two historical cohorts of 261 BAF and 124 QPL. QAF enabled basal pacing more frequently than QPL (24.1% vs. 6.5%, p < .001) but not differently from BAF (p = .981). At implant, mean QAF LV myocardial threshold (LVMT) was 1.21 ± 0.8 V at 0.4 ms, not different from that of BAF (p = .346) and QPL (p = .333). At a median follow-up of 22 months, LVMT was 1.37 ± 0.90 V (p = .036 vs. implant). Acute LV lead dislodgment occurrence was low in all cohorts: 1 (0.9%) in QAF, 4 in BAF (1.5%), and none (0.0%) in QPL. During follow-up, total LV-related complication rate was lower in QAF (0.5/100 patient-years) than in BAF (4.2/100 patient-years, p = .014) and QPL (3.6/100 patient-years, p = .055). QAF, BAF, and QPL annual rate of heart failure hospitalization were respectively 6.1/100 patient-years, 2.5/100 patient-years (p = .081), and 3.6/100 patient-years (p = .346). CRT responders' rate in QAF was 69.9%, with no difference in comparison to BAF (p = .998) and QPL (p = .509). During follow-up, mean left ventricular ejection fraction (LVEF) of QAF increased from 31.8 ± 10.1% to 40.3 ± 10.7% (p < .001). The average degree of echocardiographic response (ΔLVEF) did not differ between QAF and other cohorts; however, LVEF CRT responder's distribution of QAF differs from those of BAF (p = .003) and QPL (p = .022), due to a higher percentage of super-responders. CONCLUSIONS: QAF with short interelectrode spacing resulted in non-inferior clinical outcomes and CRT responders' rate in comparison to BAF and QPL, while reducing complication rate during follow-up and increasing the possibilities of electronic repositioning to manage PNS or to optimize resynchronization therapy.
Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Terapia de Ressincronização Cardíaca/efeitos adversos , Terapia de Ressincronização Cardíaca/métodos , Dispositivos de Terapia de Ressincronização Cardíaca , Seguimentos , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Humanos , Estudos Retrospectivos , Volume Sistólico , Resultado do Tratamento , Função Ventricular EsquerdaRESUMO
INTRODUCTION: In patients with symptomatic permanent atrial fibrillation (PEAF) and narrow QRS, atrio-ventricular junction ablation (AVJA) plus cardiac resynchronization therapy (CRT) is superior to medical therapy in reducing heart failure (HF) hospitalization and all-cause mortality. To compare the mortality of a population of patients with HF, reduced EF (rEF), and PEAF treated with AVJA plus CRT with that of a contemporary cohort of patients in sinus rhythm (SR) with similar baseline characteristics. METHODS AND RESULTS: In this prospective, multicentre, observational study, all-cause mortality in a group of consecutive patients undergoing AVJA and implantable cardioverter-defibrillator (ICD) combined with CRT implantation for HFrEF, narrow QRS, and PEAF with uncontrolled ventricular rate was compared with that of a contemporary cohort of patients in SR undergoing ICD implantation (not combined with CRT) for HFrEF and narrow QRS. Individual 1:1 propensity matching of baseline characteristics was performed. A total of 824 patients were enrolled. Propensity matching yielded 107 matched pairs. After a median follow-up of 52 months, all-cause mortality was similar in patients treated with AVJA plus CRT and in the control group (p = .434). In AVJA plus CRT patients, mortality was significantly lower than in control group patients with a history of paroxysmal/persistent AF (n = 45, p = .020), and similar to that of patients without a history of AF (n = 62, p = .459). CONCLUSIONS: After adjustment for patient characteristics, the long-term prognosis of patients with HFrEF, narrow QRS, and PEAF who underwent AVJA plus CRT was similar to that of a population of patients in SR with similar characteristics.
Assuntos
Fibrilação Atrial , Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Disfunção Ventricular Esquerda , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/etiologia , Estudos Prospectivos , Volume Sistólico , Resultado do Tratamento , Disfunção Ventricular Esquerda/terapiaRESUMO
Cardiac simulation has moved from early life-saving pacemakers meant only to prevent asystole to current devices capable of physiologic stimulation for the treatment of heart rhythm and heart failure, that are also intended for remote patient and disease-progression monitoring. The actual vision of contemporary pacing aims to correct the electrophysiologic roots of mechanical inefficiency regardless of underlying structural heart diseases. The awareness of the residual cardiac dyssynchrony related to customary cardiac pacing has changed the concept of what truly represents "physiologic pacing". On a different perspective, leadless stimulation to abolish CIED surgery and prevent lead-related complications is becoming a priority both for young device recipients and for frail, elderly patients. Careful clinical evaluation attempts to bridge decision-making to patient-tailored therapy.
Assuntos
Insuficiência Cardíaca , Marca-Passo Artificial , Idoso , Desenho de Equipamento , Previsões , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , HumanosRESUMO
Background: we sought to review the evolution in the diagnosis and treatment of Arrhythmogenic Cardiomyopathy (ACM), a clinically multifaceted entity beyond the observation of ventricular arrhythmias, and the outcome of therapies aiming at sudden death prevention in a single center experience. Methods: retrospective analysis of the data of consecutive patients with an implanted cardioverter-defibrillator (ICD) and a confirmed diagnosis of ACM according to the proposed Padua Criteria, who were referred to our center from January 1992 to October 2021. Results: we enrolled 72 patients (66% males, mean age at implant 46 ± 16 years), 63.9% implanted for primary prevention. At the time of ICD implant, 29 (40.3%) patients had a right ventricular involvement, 24 (33.3%) had a dominant LV involvement and 19 (26.4%) had a biventricular involvement. After a median follow-up of 6,1 years [IQR: 2.5-9.9], 34 patients (47.2%) had 919 sustained episodes of ventricular arrhythmias (VA). 27 patients (37.5%) had 314 episodes of life-threatening arrhythmias (LT-VA), defined as sustained ventricular tachycardia ≥ 200 beats/min. Considering only the patients with an ICD capable of delivering ATP, 80.4% of VA and 65% of LT-VA were successfully terminated with ATP. 16 (22.2%) patients had an inappropriate ICD activation, mostly caused by atrial fibrillation, while in 9 patients (12.5%) there was a complication needing reintervention (in 3 cases there was a loss of ventricular sensing dictating lead revision). During the follow-up 11 (15.3%) patients died, most of them due to heart failure, and 8 (11.1%) underwent heart transplantation. Conclusions: ACM is increasingly diagnosed owing to heightened suspicion at ECG examination and to improved imaging technology and availability, though the diagnostic workflow is particularly challenging in the earliest disease stages. ICD therapy is the cornerstone of sudden death prevention, albeit its efficacy is not based on controlled studies, and VT ablation/medical therapy are complementary to this strategy. The high burden of ATP-terminated VA makes shock-only devices debatable. The progressive nature of ACM leads to severe biventricular enlargement and refractory heart failure, which pose significant treatment issues when a predominant RV dysfunction occurs owing to the reduced possibility for mechanical circulatory assistance.
RESUMO
Nuclear imaging techniques like single-photon emission computed tomography (SPECT) and radionuclide angiography have wide applications in patients receiving a cardiac implantable electrical device (CIED), who cannot usually undergo cardiac magnetic resonance. Our aim was to provide an update of single-photon imaging clinical applications, with a specific focus on CIED recipients. SPECT imaging is commonly used in CIED patients to assess myocardial perfusion, but it can also be used to evaluate myocardial viability, which is an important predictor of LV function improvement by cardiac resynchronization therapy (CRT). Radionuclide angiography has shown higher temporal resolution and reproducibility than SPECT in the evaluation of cardiac function and dyssynchrony. Left ventricular dyssynchrony as assessed by radionuclide angiography with phase analysis may be reliably used for CRT patient selection and evaluation of CRT response. SPECT imaging with meta-iodo-benzyl-guanidine allows for cardiac sympathetic innervation examination, which may be used for prognostic stratification of heart failure patients and prediction of ventricular tachyarrhythmias. Finally, promising results in CIED infection diagnosis have been shown by SPECT with radiolabeled autologous white blood cells.
Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Imagem de Perfusão do Miocárdio , Disfunção Ventricular Esquerda , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/terapia , Humanos , Imagem de Perfusão do Miocárdio/métodos , Reprodutibilidade dos Testes , Tomografia Computadorizada de Emissão de Fóton Único/métodosRESUMO
Cardiac implantable electronic device (CIED) infection represents a dramatic event with a high mortality rate (>3x) despite antibiotic therapy and device extraction; therefore, the real winning strategy in this situation could be represented by prevention. Antibiotic prophylaxis and antibiotic-releasing envelope are effective in improving patient outcome; however, healthcare costs related to CIED infections remain high over the years. In this review we would keep the attention on a pre-surgical checklist to reduce the risk of CIED infections. In fact, checklist is an effective instrument for medical care quality improvement mainly used in surgery, but not very commonly in cath-lab and electrophysiology procedures. All steps of this checklist are of proven effectiveness in reducing the risk of CIED infections but, up till now, they are not considered together in a pre-surgical approach.
Assuntos
Lista de Checagem , Desfibriladores Implantáveis , Marca-Passo Artificial , Infecções Relacionadas à Prótese/prevenção & controle , Antibioticoprofilaxia , Humanos , Período Pré-OperatórioRESUMO
Congenital complete atrioventricular block (CCAVB) is usually due to failure of atrioventricular nodal conduction with preservation of the His-Purkinje system. Most patients with CCAVB ultimately require pacemaker therapy to restore physiologic heart rates, dealing with the detrimental effects of chronic right ventricular (RV) pacing on cardiac structure and function. The ideal stimulation pattern aims to mimic the normal conduction to restore electromechanical coupling, preventing the harmful effects of lack of atrioventricular and inter-intraventricular synchrony. This can be done through conduction system pacing. Using His bundle pacing (HBP) for cardiac resynchronization therapy in two complete congenital atrioventricular block patients, we have reported better exercise tolerance and echocardiographic improvements related to reversible left ventricular dysfunction that can be corrected by restoration of the normal activation pathway via the His-Purkinje network.
Assuntos
Bloqueio Atrioventricular , Terapia de Ressincronização Cardíaca , Bloqueio Atrioventricular/terapia , Fascículo Atrioventricular , Doença do Sistema de Condução Cardíaco , Estimulação Cardíaca Artificial , Eletrocardiografia , Bloqueio Cardíaco/congênito , Humanos , Resultado do TratamentoRESUMO
INTRODUCTION: The PRAETORIAN score (PS) was developed to assess the implant position and predict defibrillation success of the subcutaneous implantable cardioverter defibrillators (S-ICD). The main critique moved to the routine use of PS has been its postprocedural timing, that limits its usefulness on procedure guidance. The aim of this proof-of-concept study was to assess the feasibility of an intraprocedural use of PS. METHODS: Forty consecutive patients undergoing S-ICD implantation were enrolled. Intraprocedural PS (IP-PS) obtained with fluoroscopy before closure of the pocket and postprocedural PS (PP-PS) obtained with two-views chest X-ray were compared. Intraprocedural data and PS were compared with the historic cohorts of the involved institutions. RESULTS: When assessing IP-PS and PP-PS, a complete overall agreement was observed (100%, 1.00-κ; p < .001). When assessing a per-step agreement, a very high-degree of concordance in evaluating Step 1 of the PS was observed (95%, 0.81-κ; p < .001). A complete agreement in Step 2-3 (100%, 1.00-κ; p < .001) of the PS was reported. In comparison with our historical cohort, procedural time in the IP-PS cohort did not increase (45 [41-52] vs. 45 [39-49] min; p = .351) while the expected increase in fluoroscopy time resulted scarce (15 [10-15] s). CONCLUSION: An IP-PS can be reliably obtained using fluoroscopy guidance during S-ICD implantation, without a significant increase in procedural duration and may serve as guidance for implanting physicians, to avoid postprocedural S-ICD repositioning, leading to patient discomfort and significantly enhancing infective risks. IP-PS showed a very high agreement with the PP-PS obtained from two-views chest X-ray.