Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Nat Neurosci ; 9(11): 1362-3, 2006 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-17013380

RESUMO

We examined the contribution of 5-HT1A autoreceptors (with [11C]WAY100635 positron emission tomography) to amygdala reactivity (with blood oxygenation level-dependent functional magnetic resonance imaging) in 20 healthy adult volunteers. We found a significant inverse relationship wherein 5-HT1A autoreceptor density predicted a notable 30-44% of the variability in amygdala reactivity. Our data suggest a potential molecular mechanism by which a reduced capacity for negative feedback regulation of 5-HT release is associated with increased amygdala reactivity.


Assuntos
Tonsila do Cerebelo/fisiologia , Homeostase/fisiologia , Receptor 5-HT1A de Serotonina/fisiologia , Adulto , Depressão/metabolismo , Retroalimentação/fisiologia , Humanos , Imageamento por Ressonância Magnética , Oxigênio/sangue , Piperazinas/farmacologia , Tomografia por Emissão de Pósitrons , Piridinas/farmacologia , Receptor 5-HT1A de Serotonina/efeitos dos fármacos , Antagonistas da Serotonina/farmacologia
2.
Neuroimage ; 40(1): 213-6, 2008 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-18178484

RESUMO

A quality control method is described for verifying that the coordinate systems of a PET and MR image from the same subject have the same relative left-right orientation. Such ambiguities can arise, for example, at the coordinating center receiving data from many institutions in large multisite studies. In this study, image registration was performed on the PET/MR image pair. The MR image was then reflected (left/right reversed) and the image registration was performed again. A comparison of the values of the cost function describing the accuracy of the registration was used to identify the correct relative orientation. In 122 studies using data with known orientations, 100% accuracy of the method was observed.


Assuntos
Processamento de Imagem Assistida por Computador/estatística & dados numéricos , Imageamento por Ressonância Magnética/estatística & dados numéricos , Tomografia por Emissão de Pósitrons/estatística & dados numéricos , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Compostos de Anilina , Interpretação Estatística de Dados , Feminino , Fluordesoxiglucose F18 , Lateralidade Funcional/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade , Controle de Qualidade , Compostos Radiofarmacêuticos , Tiazóis
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa