Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 59
Filtrar
1.
Anal Bioanal Chem ; 415(11): 2071-2080, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36808275

RESUMO

An electrochemical sensor based on a screen-printed carbon electrode (SPCE) modified with porphyrin-functionalized magnetic graphene oxide (TCPP-MGO) was developed for the sensitive and selective determination of malondialdehyde (MDA), an important biomarker of oxidative damage, in serum samples. The coupling of TCPP with MGO allows the exploitation of the magnetic properties of the material for separation, preconcentration, and manipulation of analyte, which is selectively captured onto the TCPP-MGO surface. The electron-transfer capability in the SPCE was improved through derivatization of MDA with diaminonaphthalene (DAN) (MDA-DAN). TCPP-MGO-SPCEs have been employed to monitor the differential pulse voltammetry (DVP) levels of the whole material, which is related to the amount of the captured analyte. Under optimum conditions, the nanocomposite-based sensing system has proved to be suitable for the monitoring of MDA, presenting a wide linear range (0.01-100 µM) with a correlation coefficient of 0.9996. The practical limit of quantification (P-LOQ) of the analyte was 0.010 µM, and the relative standard deviation (RSD) was 6.87% for 30 µM MDA concentration. Finally, the developed electrochemical sensor has demonstrated to be adequate for bioanalytical applications, presenting an excellent analytical performance for the routine monitoring of MDA in serum samples.


Assuntos
Grafite , Óxido de Magnésio , Malondialdeído , Grafite/química , Carbono/química , Eletrodos , Fenômenos Magnéticos , Técnicas Eletroquímicas
2.
Environ Sci Technol ; 56(13): 9527-9535, 2022 07 05.
Artigo em Inglês | MEDLINE | ID: mdl-35700386

RESUMO

The extensive use of graphene materials in real-world applications has increased their potential release into the environment. To evaluate their possible health and ecological risks, there is a need for analytical methods that can quantify these materials at very low concentrations in environmental media such as water. In this work, a simple, reproducible, and sensitive method to detect graphene oxide (GO) in water samples using the surface-enhanced Raman spectroscopy (SERS) technique is presented. The Raman signal of graphene is enhanced when deposited on a substrate of gold nanoparticles (AuNPs), thus enabling its determination at low concentrations with no need for any preconcentration step. The practical limit of quantification achieved with the proposed method was 0.1 ng mL-1, which is lower than the predicted concentrations for graphene in effluent water reported to date. The optimized procedure has been successively applied to the determination of ultratraces of GO in water samples.


Assuntos
Grafite , Nanopartículas Metálicas , Ouro/química , Grafite/química , Nanopartículas Metálicas/química , Análise Espectral Raman/métodos , Água
3.
Int J Mol Sci ; 23(11)2022 Jun 02.
Artigo em Inglês | MEDLINE | ID: mdl-35682910

RESUMO

Unlike humans, some animals have evolved a physiological ability to deposit porphyrins, which are pigments produced during heme synthesis in cells, in the skin and associated integument such as hair. Given the inert nature and easiness of collection of hair, animals that present porphyrin-based pigmentation constitute unique models for porphyrin analysis in biological samples. Here we present the development of a simple, rapid, and efficient analytical method for four natural porphyrins (uroporphyrin I, coproporphyrin I, coproporphyrin III and protoporphyrin IX) in the Southern flying squirrel Glaucomys volans, a mammal with hair that fluoresces and that we suspected has porphyrin-based pigmentation. The method is based on capillary liquid chromatography-mass spectrometry (CLC-MS), after an extraction procedure with formic acid and acetonitrile. The resulting limits of detection (LOD) and quantification (LOQ) were 0.006-0.199 and 0.021-0.665 µg mL-1, respectively. This approach enabled us to quantify porphyrins in flying squirrel hairs at concentrations of 3.6-353.2 µg g-1 with 86.4-98.6% extraction yields. This method provides higher simplicity, precision, selectivity, and sensitivity than other methods used to date, presenting the potential to become the standard technique for porphyrin analysis.


Assuntos
Porfirinas , Animais , Cromatografia Líquida de Alta Pressão/métodos , Cromatografia Líquida , Cabelo/química , Mamíferos , Espectrometria de Massas , Porfirinas/química
4.
Molecules ; 27(9)2022 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-35566264

RESUMO

A rapid and sensitive technique for frauds determination in vanilla flavors was developed. The method comprises separation by liquid chromatography followed by an electrochemical detection using a homemade screen-printed carbon electrode modified with aluminium-doped zirconia nanoparticles (Al-ZrO2-NPs/SPCE). The prepared nanomaterials (Al-ZrO2-NPs) were characterized by using X-ray diffraction (XRD), transmission electron microscopy (TEM) and energy dispersive X-ray (EDX). This method allows for the determination of six phenolic compounds of vanilla flavors, namely, vanillin, p-hydroxybenzoic acid, p-hydroxybenzaldehyde, vanillyl alcohol, vanillic acid and ethyl vanillin in a linear range between 0.5 and 25 µg g-1, with relative standard deviation values from 2.89 to 4.76%. Meanwhile, the limits of detection and quantification were in the range of 0.10 to 0.14 µg g-1 and 0.33 to 0.48 µg g-1, respectively. In addition, the Al-ZrO2-NPs/SPCE method displayed a good reproducibility, high sensitivity, and good selectivity towards the determination of the vanilla phenolic compounds, making it suitable for the determination of vanilla phenolic compounds in vanilla real extracts products.


Assuntos
Nanopartículas , Vanilla , Alumínio , Cromatografia Líquida/métodos , Técnicas Eletroquímicas , Eletrodos , Aromatizantes/análise , Nanopartículas/análise , Fenóis/química , Reprodutibilidade dos Testes , Vanilla/química , Zircônio
5.
Molecules ; 26(9)2021 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-34063259

RESUMO

In this study, we combine magnetic solid phase extraction (MSPE), with the screen-printed carbon electrode (SPCE) modified by a molecular imprinted polymer (MIP) for sensitive and selective extraction and electrochemical determination of Rhodamine B in food samples. A magnetic solid phase extraction (MSPE) was carried out using magnetic poly(styrene-co-divinylbenzene) (PS-DVB) and magnetic nanoparticles (MNPs) synthetized on the surface of multiwalled carbon nanotubes (MWCNTs). An MIP was prepared on the surface of MWCNTs in the presence of titanium oxide nanoparticles (TiO2NPs) modifying the SPCE for the rapid electrochemical detection of Rhodamine B. The MIPs synthesis was optimized by varying the activated titanium oxide (TiO2) and multiwalled carbon nanotubes (MWCNTs) amounts. The MSPE and electrochemical detection conditions were optimized as well. The present method exhibited good selectivity, high sensitivity, and good reproducibility towards the determination of Rhodamine B, making it a suitable method for the determination of Rhodamine B in food samples.


Assuntos
Análise de Alimentos/métodos , Nanotubos de Carbono/química , Polímeros/química , Rodaminas/análise , Adsorção , Técnicas Eletroquímicas , Eletrodos , Concentração de Íons de Hidrogênio , Limite de Detecção , Magnetismo , Microscopia Eletrônica de Varredura , Impressão Molecular , Polímeros Molecularmente Impressos , Poliestirenos/química , Reprodutibilidade dos Testes , Espalhamento de Radiação , Sensibilidade e Especificidade , Extração em Fase Sólida/métodos , Análise Espectral Raman , Titânio/química
6.
Cell Mol Life Sci ; 76(2): 397-404, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30413834

RESUMO

Hormones have not been found in concentrations of orders of magnitude higher than nanograms per milliliter. Here, we report urine concentrations of a catecholamine (norepinephrine) ranging from 0.05 to 0.5 g/l, and concentrations of its metabolite DL-3,4-dihydroxyphenyl glycol (DOPEG) ranging from 1.0 to 44.5 g/l, in wild male red deer Cervus elaphus hispanicus after LC-MS analyses. The dark ventral patch of male red deer, a recently described sexually selected signal, contains high amounts of DOPEG (0.9-266.9 mg/l) stuck in the hairs, while DOPEG is not present in non-darkened hair. The formation of this dark patch is explained by the chemical structure of DOPEG, which is a catecholamine-derived o-diphenol susceptible to be oxidized by air and form allomelanins, nitrogen-free pigments similar to cutaneous melanins; by its high concentration in urine; and by the urine spraying behavior of red deer by which urine is spread through the ventral body area. Accordingly, the size of the dark ventral patch was positively correlated with the concentration of DOPEG in urine, which was in turn correlated with DOPEG absorbed in ventral hair. These findings represent catecholamine concentrations about one million higher than those previously reported for any hormone in an organism. This may have favored the evolution of the dark ventral patch of red deer by transferring information on the fighting capacity to rivals and mates. Physiological limits for hormone production in animals are thus considerably higher than previously thought. These results also unveil a novel mechanism of pigmentation based on the self-application of urine over the fur.


Assuntos
Catecolaminas/metabolismo , Cabelo/metabolismo , Pigmentação/fisiologia , Animais , Catecolaminas/urina , Cromatografia Líquida de Alta Pressão , Cervos , Cabelo/química , Masculino , Espectrometria de Massas , Melaninas/metabolismo , Metoxi-Hidroxifenilglicol/análogos & derivados , Metoxi-Hidroxifenilglicol/urina
7.
Electrophoresis ; 40(18-19): 2336-2341, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31116440

RESUMO

A new CE method with fluorescence detection is reported on the determination of ofloxacin in milk samples using graphene quantum dots (GQDs) for sensitivity enhancement. Injection of GQDs prior the standards/sample is crucial to increase the antibiotic fluorescence response. Clean-up and preconcentration steps allowed for a good linear correlation in a concentration range between 50 and 1000 ng/mL for the ofloxacin, detection and quantification limits being 10.7 and 35.5 ng/mL, respectively. Optimal CE conditions for the seven-fluoroquinolone separation method were assessed in terms of buffer type, pH, and voltage. The selective interaction of GQDs with ofloxacin as model analyte was subsequently studied finding a significant sensitivity improvement; therefore, the analytes would be detected at low concentrations by means of a commercial CE device equipped with a multi-wavelength photoluminescence detector. Due to the different maximum emission wavelengths of the target compounds and the limitations shown by the single-wavelength photoluminescence detector coupled to the CE system, we demonstrated the usefulness of the GQD-assisted sensitivity-enhanced CE method to determine ofloxacin in milk samples. This work opens an interesting possibility of using GQDs in separation techniques combined with photoluminescence detectors for lowering sensitivity levels typically provided by the mere device.


Assuntos
Eletroforese Capilar/métodos , Grafite/química , Ofloxacino/análise , Pontos Quânticos/química , Espectrometria de Fluorescência/métodos , Animais , Resíduos de Drogas/análise , Resíduos de Drogas/isolamento & purificação , Limite de Detecção , Modelos Lineares , Leite/química , Ofloxacino/isolamento & purificação , Reprodutibilidade dos Testes
8.
J Exp Biol ; 222(Pt 11)2019 06 10.
Artigo em Inglês | MEDLINE | ID: mdl-31097603

RESUMO

Pigments are largely responsible for the appearance of organisms. Most biological pigments derive from the metabolism of shikimic acid (melanins), mevalonic acid (carotenoids) or levulinic acid (porphyrins), which thus generate the observed diversity of external phenotypes. Starlings are generally dark birds despite iridescence in feathers, but 10% of species have evolved plumage pigmentation comprising bright colors that are known to be produced only by carotenoids. However, using micro-Raman spectroscopy, we have discovered that the bright yellow plumage coloration of one of these species, the Afrotropical golden-breasted starling Cosmopsarus regius, is not produced by carotenoids, but by vitamin A (all-trans-retinol). This is the first organism reported to deposit significant amounts of vitamin A in its integument and use it as a body pigment. Phylogenetic reconstructions reveal that the retinol-based pigmentation of the golden-breasted starling has independently appeared in the starling family from dark ancestors. Our study thus unveils a unique evolution of a new class of external pigments consisting of retinoids.


Assuntos
Pigmentação , Estorninhos/fisiologia , Vitamina A/metabolismo , Animais , Evolução Biológica , Plumas/química , Filogenia , Análise Espectral Raman
9.
Electrophoresis ; 2018 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-29676811

RESUMO

Poly(styrene-co-divinylbenzene)-coated magnetic multiwalled carbon nanotube composite synthesized by in-situ high temperature combination and precipitation polymerization of styrene-co-divinylbenzene has been employed as a magnetic sorbent for the solid phase extraction of antidepressants in human urine samples. Fluoxetine, venlafaxine, citalopram and sertraline were, afterwards, separated and determined by capillary electrophoresis with diode array detection. The presence of magnetic multiwalled carbon nanotubes in native poly(styrene-co-divinylbenzene) not only simplified sample treatment but also enhanced the adsorption efficiencies, obtaining extraction recoveries higher than 89.5% for all analytes. Moreover, this composite can be re-used at least ten times without loss of efficiency and limits of detection ranging from 0.014 to 0.041 µg/mL were calculated. Additionally, precision values ranging from 0.08 to 7.50% and from 0.21 to 3.05% were obtained for the responses and for the migration times of the analytes, respectively.

10.
Electrophoresis ; 39(12): 1437-1442, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29579360

RESUMO

It is described a simple, rapid and efficient methodology to characterise and separate gold nanoprisms and nanooctahedra by capillary electrophoresis. This technique is suitable to distinguish between morphologies and it can be used as a powerful separation tool after a customised synthesis of both structures. This synthesis was carried out by amending two parameters, temperature and pH, and a sharp decrease was found in nanotriangles when temperature was increased from 70 up to 95°C. However, when the synthesis was performed at a given temperature, an increase in pH did not promote an important change in isolation of any structure until pH = 9.5, critical in the final morphology of the nanoparticle. Gold nanoprisms and nanooctahedra were successfully separated by capillary electrophoresis according to differences in charge-to-mass ratio of the morphologies. Final particle morphology was confirmed by transmission electron microscopy analysis. Under optimal working conditions, a mixture containing both shapes of gold nanoparticles was initially injected and two major peaks were obtained for each structure. Capillary electrophoresis allowed to study pH and temperature influence on both morphologies. It was inferred that the ratio between triangles and octahedra decreased to a great extent when increasing both temperature and pH.


Assuntos
Eletroforese Capilar , Ouro , Nanopartículas Metálicas/análise , Eletroforese Capilar/métodos , Nanopartículas Metálicas/química , Nanotecnologia/métodos
11.
Electrophoresis ; 39(13): 1628-1633, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29508413

RESUMO

A capillary electrophoresis method was developed for the determination of coumarin (COUM), ethyl vanillin (EVA), p-hydroxybenzaldehyde (PHB), p-hydroxybenzoic acid (PHBA), vanillin (VAN), vanillic acid (VANA) and vanillic alcohol (VOH) in vanilla products. The measured concentrations are compared to values obtained by liquid chromatography (LC) method. Analytical results, method precision, and accuracy data are presented and limits of detection for the method ranged from 2 to 5 µg/mL. The results obtained are used in monitoring the composition of vanilla flavorings, as well as for confirmation of natural or non-natural origin of vanilla in samples using four selected food samples containing this flavor.


Assuntos
Eletroforese Capilar , Aromatizantes/análise , Vanilla/química , Benzaldeídos/análise , Cromatografia Líquida de Alta Pressão , Cumarínicos/análise , Eletroforese Capilar/métodos , Qualidade dos Alimentos , Parabenos/análise
12.
Anal Bioanal Chem ; 409(21): 5125-5132, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28714042

RESUMO

A rapid and reliable method based on magnetic solid-phase extraction (MSPE) and ultra-high performance liquid chromatography (UHPLC-FLD) analysis was developed and validated for the quantitative determination of seven polycyclic aromatic hydrocarbons (PAHs) in water samples. Hybrid composites made up of magnetic nanoparticles (MNPs) and carbon nanotubes (CNTs) were tested as adsorbent materials. The main factors influencing the extraction yields were optimized, namely the amount and type of adsorbent in the adsorption, and the solvent, the type of energy and the time in the desorption step. The selected composite was made up of Fe3O4 and multiwalled (MW)-CNTs. The desorption was carried out with sonication probe and tetrahydrofuran (THF); this solvent makes the method directly compatible with the chromatographic mobile phase and it reduces the analysis time. Under the optimized conditions, the LODs and LOQs achieved were in the range of 0.025-0.73 and 0.04-2.4 ng mL-1, respectively. The calibration curves were linear (R 2 ≥ 0.9936) over the concentration ranges from 1 to 500 ng mL-1. The recoveries of PAHs were from 76.4 ± 1.7 up to 106.5 ± 3.5%. The method was applied to synthetic and real (tap, dam, river and mineral) water samples with different characteristics to evaluate the performance under real conditions.

13.
Anal Methods ; 16(13): 1870-1879, 2024 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-38465391

RESUMO

This paper presents a study on the application of magnetic biochars derived from three distinct biomass sources: almond (AMBC), walnut (WMBC), and peanut (PMBC) shells for magnetic solid-phase extraction (MSPE) of naproxen, a non-steroidal anti-inflammatory drug, from human saliva prior to LC-MS analysis. The three magnetic biochars were synthesized and characterized through IR, XRD, SEM, and EDX analyses. This work explored the factors influencing extraction efficiency using these three bioadsorbents through experimental design. The results obtained revealed that magnetic biochar derived from almond shells demonstrated outstanding performance in terms of naproxen extraction, achieving an impressive yield of 100.2%. This remarkable efficiency was achieved by optimizing parameters, including a 12-minute extraction time, a 3.5 mL elution volume, a 10 mg adsorbent mass, and a 4-minute elution time. Consequently, this study established almond shell as a low-cost, environmentally friendly, and efficient magnetic biochar for extracting naproxen from human saliva. This superior performance was made possible due to the abundant lignocellulosic potential inherent in almond shell structures, surpassing that of the other two biochars. The combination of magnetic extraction with LC-MS demonstrates good linearity, with an R2 value equal to 0.9987. The limits of detection (LOD) and quantification (LOQ) are 0.013 and 0.047 µg L-1, respectively.


Assuntos
Carvão Vegetal , Naproxeno , Saliva , Humanos , Naproxeno/química , Biomassa , Extração em Fase Sólida/métodos , Fenômenos Magnéticos
14.
Anal Chem ; 85(10): 4858-62, 2013 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-23611663

RESUMO

In this technical note, an interface for coupling commercially available capillary electrophoresis (CE) equipment to an evaporative light scattering detector (ELSD) is described. The nebulization process was identified as the most critical parameter for performing the reliable coupling between both pieces of equipment. Therefore, appropriate modifications in the nebulization chamber and in the conventional nebulizer were brought to make ELSD fully compatible with CE. The impact of the customized interface on CE separation and detection was evaluated in terms of resolution and sensitivity. ELSD can be considered as an attractive alternative to other CE detection systems (e.g., UV-vis, fluorescence, electrochemical detection, or even MS detection), particularly those in which derivatization is needed. This advantage is due to the versatility and the quasi-universality of ELSD. Thus, sensitive and fast separations of several compounds were performed using this CE-ELSD customized arrangement, which opens up an interesting analytical potential for the determination of compounds not presenting sensitive UV-vis chormophore, fluorophore, or electroactive groups. Carbohydrates were selected in this work to demonstrate the applicability of CE-ELSD coupling.

15.
Electrophoresis ; 34(18): 2623-31, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23857376

RESUMO

An improved and efficient method for the determination of underivatized amino acids based on the use of CE coupled to evaporative light scattering detector (ELSD), involving carbon nanotubes, was successfully developed. Carboxyled single-walled carbon nanotubes were used for the first time to perform the clean-up of the analyzed samples, which were afterwards analyzed by CE-ELSD. White tea samples were used to demonstrate the usefulness of the CE-ELSD coupled methodology. A suitable interface, based on a triple tube design sprayer, was developed and successfully used for coupling both instruments. Parameters affecting the separation and determination, including the elimination of interferences, were studied and properly optimized. Under the optimized conditions good resolution was achieved for the separation of seven amino acids. The precision of the method, expressed as RSD, was found within the 3.5-5.3% range. The LOD obtained for the proposed method were in the 1.2-2.1 pg range and the LOQ, were in the 2.0-11.5 pg range, with injection pressure of 5 KPa for 20 s (15.3 nL). This method is simple, rapid, and selective compared with other conventional techniques.


Assuntos
Aminoácidos/análise , Eletroforese Capilar/métodos , Nanotubos de Carbono/química , Chá/química , Aminoácidos/química , Luz , Limite de Detecção , Modelos Lineares , Reprodutibilidade dos Testes , Espalhamento de Radiação
16.
Nanomaterials (Basel) ; 13(22)2023 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-37999311

RESUMO

A method was developed for the determination of total titanium in food and food supplements by inductively coupled plasma mass spectrometry (ICP-MS) after microwave-assisted acid digestion of samples. Five food supplements, including one certified reference material, and 15 food products were used for method development. Key factors affecting the analytical results, such as the composition of the acid mixture for sample digestion and the bias from spectral interferences on the different titanium isotopes, were investigated. Resolution of interferences was achieved by ICP-MS/MS with ammonia adduct formation and viable conditions for control laboratories equipped with standard quadrupole instruments were identified. The method was successfully validated and enables rapid screening of samples subject to confirmatory analysis for the presence of TiO2 particles. For the latter, single-particle ICP-MS (spICP-MS) analysis after chemical extraction of the particles was used. The two methods establish a viable analytical strategy for assessing the absence of titania particles in food products on the EU market following the E 171 ban as a food additive.

17.
Chemosphere ; 333: 138847, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37187374

RESUMO

In this work, it is studied the photolysis, electrolysis, and photo-electrolysis of a mixture of pharmaceutics (sulfadiazine, naproxen, diclofenac, ketoprofen and ibuprofen) contained in two very different types of real water matrices (obtained from surface and porewater reservoirs), trying to clarify the role of the matrix on the degradation of the pollutants. To do this, a new metrological approach was also developed for screening of pharmaceuticals in waters by capillary liquid chromatography mass spectrometry (CLC-MS). This allows the detection at concentrations lower than 10 ng mL-1. Results obtained in the degradation tests demonstrate that inorganic composition of the water matrix directly influences on the efficiency of the drugs removal by the different EAOPs and better degradation results were obtained for experiments carried out with surface water. The most recalcitrant drug studied was ibuprofen for all processes evaluated, while diclofenac and ketoprofen were found to be the easiest drugs for being degraded. Photo-electrolysis was found to be more efficient than photolysis and electrolysis, and the increase in the current density was found to attain a slight improvement in the removal although with an associated huge increase in the energy consumption. The main reaction pathways for each drug and technology were also proposed.


Assuntos
Cetoprofeno , Poluentes Químicos da Água , Diclofenaco/química , Cetoprofeno/análise , Ibuprofeno/análise , Água/química , Poluentes Químicos da Água/análise , Preparações Farmacêuticas
18.
Anal Bioanal Chem ; 404(5): 1529-38, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22832671

RESUMO

A magnetic material based on N-methylimidazolium ionic liquid and Fe(3)O(4) magnetic nanoparticles incorporated in a silica matrix has been used to extract and preconcentrate sulfonylurea herbicides, such as thifensulfuron methyl (TSM), metsulfuron methyl (MSM), triasulfuron (TS), tribenuron methyl (TBM) and primisulfuron methyl (PSM) from polluted water samples, prior to their analysis by capillary liquid chromatography with a diode array detector (DAD). Under the optimum conditions, this method allows the determination of TSM, MSM, TS, TBM and PSM in a linear range between 5 and 100 ng mL(-1), with relative standard deviation values lower than 5.3% (n = 10), in all cases. Detection limits ranging between 1.13 and 2.95 ng mL(-1) were achieved. The usefulness of the proposed method was demonstrated by the analysis of river water samples, obtaining recoveries higher than 91%.


Assuntos
Herbicidas/isolamento & purificação , Líquidos Iônicos/química , Nanopartículas de Magnetita/química , Extração em Fase Sólida/métodos , Compostos de Sulfonilureia/isolamento & purificação , Poluentes Químicos da Água/isolamento & purificação , Adsorção , Cromatografia Líquida/métodos , Imidazóis/química , Limite de Detecção , Rios/química , Dióxido de Silício/química
19.
Crit Rev Anal Chem ; 52(5): 1094-1111, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-33427485

RESUMO

An overview on the increasing role of capillary electrophoresis in characterization and direct analysis of nanomaterials is herein presented. The niche of electrophoretic approaches in nanometrology is so relevant that nonmetallic, metal, metal oxide nanoparticles, and quantum dots have been analyzed to be targeted via capillary electrophoresis with conventional detection systems or coupling arrangements aimed at increasing selectivity and sensitivity toward either pristine or conjugated nanoparticles. Moreover, parameters altering intrinsic properties of nanoparticles may be optimized to gather the desired results and identify nanomaterials according to their size, shape, or associations with binding agents. The usefulness and quickness of capillary electrophoresis for quantifying or screening ultrasmall-sized particles enables this technique to set an example for analysis of standards or previously synthesized nanostructures in research or routine laboratories. Abundant evidence of the suitability of electrophoretic approaches for characterization and direct determination of nanomaterials in actual samples has been provided in this review, together with a discussion about hyphenation with state-of-the art detectors and comparison between capillary electrophoresis with other separation approaches. This permits scientific community to be optimistic in the short term.


Assuntos
Nanopartículas Metálicas , Nanoestruturas , Eletroforese Capilar/métodos , Nanopartículas Metálicas/química , Nanoestruturas/química
20.
Talanta ; 226: 122106, 2021 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-33676662

RESUMO

A simple and rapid microextraction procedure is reported on the use of ionic liquid (IL) in combination with magnetic multiwalled carbon nanotubes (MMWCNTs). The procedure is based on temperature-controlled IL dispersive liquid phase microextraction (DLPME) and MMWCNTs, for selective preconcentration of N-methylcarbamate pesticides in water samples, followed by their hydrolysis in alkaline buffer, prior to being analyzed by capillary electrophoresis. The extraction procedure uses small volume of organic solvents, and there is no need for centrifugation. In the experimental approach the IL was quickly disrupted by an ultrasonic probe, heated with the temperature controlled at 90 °C and dispersed in water samples in a homogenous form. At this stage, N-methylcarbamate pesticides migrate into the IL. Then the solution was cooled and small amounts of MMWCNTs were dispersed into the sample solutions to adsorb the ionic liquid containing the analytes and phase separation was completed. The ionic liquid allowed the microextraction of the analytes and a small volume of dichloromethane (DCM) was used for elution. MMWCNTs favored the adsorption of the ionic liquid with the analytes and improved the final recovery with respect to the use of simple magnetic nanoparticles as a sorbent material. Under the optimum conditions, limit of quantifications (LOQ) were achieved in the 5.6-9.3 ng mL-1 range, with recoveries between 85.0% and 102.4%.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa