Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 68
Filtrar
1.
Rev Cardiovasc Med ; 25(1): 30, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-39077659

RESUMO

Background: Off-pump coronary artery bypass grafting (OPCAB) is an alternative to on-pump coronary artery bypass grafting (CABG) with cardiopulmonary bypass (CPB). During OPCAB, the temporary use of an intracoronary shunt and inotropic medication or catecholamines should keep the central hemodynamics constant. Nevertheless, the need for conversion to on-pump CABG often occurs unexpectedly, most likely due to circulation instability. Circulation instability can appear first in peripheral body parts; therefore, peripheral microcirculation might serve as a predictor for the upcoming conversion to on-pump CABG. We investigated the impact of coronary artery ligation and shunt insertion during OPCAB on cutaneous microcirculation (cLDP) with Laser Doppler Perfusion Technology and transcutaneous oxygen partial pressure ( tcpO 2 ). Methods: In a pig model of OPCAB, peripheral circulation was evaluated after cLDP (N = 17) and tcpO 2 (N = 6) monitoring. Systolic, diastolic, and mean arterial pressure were also observed to prove the independence of perfusion measurement results from hemodynamic parameters. Results: Ligation time during cLDP and tcpO 2 monitoring were 101 ± 49 s and 83 ± 33 s, respectively. Shunt time was 11 ± 3 min during cLDP and 13 ± 2 min during tcpO 2 measurement. Ligation of the left anterior descending coronary artery (LAD) reduced cLDP significantly to 88 ± 14% (p = 0.007) and tcpO 2 to 71 ± 25% (p = 0.038). Inserting a temporary shunt into the LAD significantly improved cLDP (p = 0.006) and tcpO 2 (p = 0.015) compared to ligation. cLDP was restored to 99%, and tcpO 2 was restored to 91% of the baseline level before ligation. All hemodynamic parameters remained stable and did not change significantly during OPCAB. Conclusions: Although hemodynamic parameters stayed constant, peripheral microcirculation was influenced markedly during OPCAB. Inserting a temporary shut into the LAD leads to a complete normalization of peripheral microcirculation, regarding evaluation by cLDP and tcpO 2 .

2.
Artif Organs ; 48(1): 16-27, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37822301

RESUMO

BACKGROUND: The management of concomitant valvular lesions in patients undergoing left ventricular assist device (LVAD) implantation remains a topic of debate. This systematic review and meta-analysis aimed to evaluate the existing evidence on postoperative outcomes following LVAD implantation, with and without concomitant MV surgery. METHODS: A systematic database search was conducted as per PRISMA guidelines, of original articles comparing LVAD alone to LVAD plus concomitant MV surgery up to February 2023. The primary outcomes assessed were overall mortality and early mortality, while secondary outcomes included stroke, need for right ventricular assist device (RVAD) implantation, postoperative mitral valve regurgitation, major bleeding, and renal dysfunction. RESULTS: The meta-analysis included 10 studies comprising 32 184 patients. It revealed that concomitant MV surgery during LVAD implantation did not significantly affect overall mortality (OR:0.83; 95% CI: 0.53 to 1.29; p = 0.40), early mortality (OR:1.17; 95% CI: 0.63 to 2.17; p = 0.63), stroke, need for RVAD implantation, postoperative mitral valve regurgitation, major bleeding, or renal dysfunction. These findings suggest that concomitant MV surgery appears not to confer additional benefits in terms of these clinical outcomes. CONCLUSION: Based on the available evidence, concomitant MV surgery during LVAD implantation does not appear to have a significant impact on postoperative outcomes. However, decision-making regarding MV surgery should be individualized, considering patient-specific factors and characteristics. Further research with prospective studies focusing on specific patient populations and newer LVAD devices is warranted to provide more robust evidence and guide clinical practice in the management of valvular lesions in LVAD recipients.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Nefropatias , Insuficiência da Valva Mitral , Acidente Vascular Cerebral , Humanos , Insuficiência da Valva Mitral/complicações , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Coração Auxiliar/efeitos adversos , Estudos Prospectivos , Resultado do Tratamento , Hemorragia/complicações , Nefropatias/complicações , Estudos Retrospectivos
3.
Artif Organs ; 48(4): 356-364, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38010063

RESUMO

BACKGROUND: Infective endocarditis (IE) poses a significant health risk, especially in patients with prosthetic heart valves. Despite advances in treatment, mortality rates remain high. This study aims to investigate the antibacterial properties of a copper titanium dioxide (4× Cu-TiO2) coating on cardiovascular implants against Staphylococcus aureus, a common causative agent of IE. METHODS: Titanium oxide carriers functionalized with copper ions were employed as an antibacterial coating for heart and vascular prostheses. The coating's antibacterial efficacy was assessed using S. aureus ATCC 29213. Microscopic evaluations were conducted on both biological and artificial materials. Antibacterial activity was qualitatively assessed via a modified disc diffusion method and quantitatively measured through colony counts in NaCl suspensions. RESULTS: The coating process was successfully applied to all tested cardiovascular prosthetic materials. Qualitative assessments of antibacterial effectiveness revealed an absence of bacterial growth in the area directly beneath the coated valve. Quantitative evaluations showed a significant reduction in bacterial colonization on coated mechanical valves, with 2.95 × 104 CFU per valve, compared to 1.91 × 105 CFU in control valves. CONCLUSIONS: The 4× Cu-TiO2 coating demonstrated promising antibacterial properties against S. aureus, suggesting its potential as an effective strategy for reducing the risk of bacterial colonization of cardiovascular implants. Further studies are needed to assess the longevity of the coating and its efficacy against other pathogens.


Assuntos
Endocardite Bacteriana , Endocardite , Próteses Valvulares Cardíacas , Humanos , Cobre , Staphylococcus aureus , Projetos Piloto , Materiais Revestidos Biocompatíveis , Antibacterianos/farmacologia , Antibacterianos/uso terapêutico , Próteses e Implantes , Endocardite Bacteriana/prevenção & controle , Titânio
4.
Thorac Cardiovasc Surg ; 72(2): 134-141, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37506731

RESUMO

BACKGROUND: Computational fluid dynamics (CFD) simulations model blood flow in aortic pathologies. The aim of our study was to understand the local hemodynamic environment at the site of rupture in distal stent graft-induced new entry (dSINE) after frozen elephant trunk with a clinically time efficient steady-flow simulation versus transient simulations. METHODS: Steady-state simulations were performed for dSINE, prior and after its development and prior to aortic rupture. To account for potential turbulences due geometric changes at the dSINE location, Reynolds-averaged Navier-Stokes equations with the realizable k-ε model for turbulences were applied. Transient simulations were performed for comparison. Hemodynamic parameters were assessed at various locations of the aorta. RESULTS: Post-dSINE, jet-like flow due to luminal narrowing was observed which increased prior to rupture and resulted in focal neighbored regions of high and low wall shear stress (WSS). Prior to rupture, aortic diameter at the rupture site increased lowering WSS at the entire aortic circumference. Concurrently, WSS and turbulence increased locally above the entry tear at the inner aortic curvature. Turbulent kinetic energy and WSS elevation in the downstream aorta demonstrated enhanced stress on the native aorta. Results of steady-state simulations were in good qualitative agreement with transient simulations. CONCLUSION: Steady-flow CFD simulations feasible at clinical time scales prior to aortic rupture reveal a hostile hemodynamic environment at the dSINE rupture site in agreement with lengthy transient simulations. Consequently, our developed approach may be of value in treatment planning where a fast assessment of the local hemodynamic environment is essential.


Assuntos
Ruptura Aórtica , Humanos , Ruptura Aórtica/diagnóstico por imagem , Ruptura Aórtica/etiologia , Ruptura Aórtica/cirurgia , Modelos Cardiovasculares , Resultado do Tratamento , Hemodinâmica , Simulação por Computador , Stents , Estresse Mecânico , Hidrodinâmica
5.
Artif Organs ; 47(3): 481-489, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36219511

RESUMO

BACKGROUND: Bioengineered transplantable heart-lung scaffolds could be potentially lifesaving in a large number of congenital and acquired cardiothoracic disorders including terminal heart-lung disease. METHODS: We decellularized heart-lung organ-blocks from rats (n = 10) by coronary and tracheal perfusion with ionic detergents in a modified Langendorff circuit. RESULTS: In the present project, we were able to achieve complete decellularization of the heart-lung organ-block. Decellularized heart-lung organ-blocks lacked intracellular components but maintained structure of the cellular walls with collagen and elastic fibers. CONCLUSIONS: We present a novel model of combined perfusion and decellularization of heart-lung organ-blocks. This model is the first step on the pathway to creating bioengineered transplantable heart-lung scaffolds. We believe that further development of this technology could provide a life-saving conduit, significantly reducing the risks of heart-lung failure surgery and improving postoperative quality of life.


Assuntos
Engenharia Tecidual , Alicerces Teciduais , Ratos , Animais , Alicerces Teciduais/química , Qualidade de Vida , Matriz Extracelular/química , Pulmão , Perfusão
6.
Artif Organs ; 47(8): 1250-1261, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37086154

RESUMO

BACKGROUND: Left ventricular assist devices (LVADs) represent an important therapeutic option for patients progressing to end-stage heart failure. LVAD has previously been shown to have a promising role in improving mitral regurgitation (MR). Nevertheless, the prognostic value of preoperative uncorrected MR in this population remains unclear. METHODS: A systematic database search with meta-analysis was conducted of comparative original articles of patients with preoperative mild MR (Grade 0-I) versus moderate-severe MR (Grade II-III) undergoing LVAD implantation, in EMBASE, MEDLINE, Cochrane database, and Google Scholar, from inception to June 2022. Primary outcomes were overall and operative mortality. Secondary outcomes were neurological dysfunction, gastrointestinal bleeding, right heart failure, LVAD thrombosis, and driveline infection. RESULTS: Our search yielded 2228 relevant studies. A total of 19 studies met the inclusion criteria with a total of 11 873 patients. LVAD caused a statistically significant decrease of 35.9% in the number of patients with moderate-severe MR (grade II-III) postoperatively. No significant difference was observed in terms of overall mortality, operative mortality, GI bleeding, LVAD thrombosis, and driveline infection rates between mild and moderate-severe MR. An increased rate of right heart failure was seen among patients with moderate-severe MR, while lower rates of neurological events were also observed. CONCLUSION: LVAD improves the haemodynamics of the left ventricle, to promote resolution of MR. Nevertheless, the severity of preoperative mitral regurgitation in patients undergoing LVAD deployment does not seem to affect mortality.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Insuficiência da Valva Mitral , Humanos , Insuficiência da Valva Mitral/complicações , Insuficiência da Valva Mitral/cirurgia , Prognóstico , Coração Auxiliar/efeitos adversos , Resultado do Tratamento , Estudos Retrospectivos , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/cirurgia
7.
Artif Organs ; 47(2): 273-289, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36461903

RESUMO

BACKGROUND: Left ventricular assist devices (LVAD) represent an important therapeutic option for patients progressing to end-stage heart failure. Women have been historically underrepresented in LVAD studies, and have been reported to have worse outcomes despite technological optimisation. We aimed to systematically explore the evidence on sex disparities in the use and outcomes of LVAD implantation. METHODS: A systematic database search with meta-analysis was conducted of comparative original articles of men versus women undergoing LVAD implantation, in EMBASE, MEDLINE, Cochrane database and Google Scholar, from inception to July 2022. Primary outcomes were stroke (haemorrhagic and ischaemic) and early/overall mortality. Secondary outcomes were LVAD thrombosis, right VAD implantation, major bleeding, kidney dysfunction, and device/driveline infection. RESULTS: Our search yielded 137 relevant studies, including 22 meeting the inclusion criteria with a total of 53 227 patients (24.2% women). Overall mortality was higher in women (odds ratio [OR] 1.35, 95% confidence interval [CI] 1.05-1.62, p = 0.02), as was overall stroke (OR 1.32, 95%CI 1.06-1.66, p = 0.01), including ischemic (OR 1.80, 95%CI 1.22-2.64, p = 0.003) and haemorrhagic (OR 1.72, 95%CI 1.09-2.70, p = 0.02). Women had more frequent right VAD implantation (OR 2.11, 95%CI 1.24-3.57, p = 0.006) and major bleeding (OR 1.40, 95%CI 1.06-1.85, p = 0.02). Kidney dysfunction, LVAD thrombosis, and device/driveline infections were comparable between sexes. CONCLUSIONS: Our analysis suggests that women face a greater risk of adverse events and mortality post-LVAD implantation. Although the mechanisms remain unclear, the difference in outcomes is thought to be multifactorial. Further research, that includes comprehensive pre-operative characteristics and post-operative outcomes, is encouraged.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Acidente Vascular Cerebral , Procedimentos Cirúrgicos Torácicos , Masculino , Humanos , Feminino , Coração Auxiliar/efeitos adversos , Insuficiência Cardíaca/cirurgia , Insuficiência Cardíaca/complicações , Acidente Vascular Cerebral/etiologia , Hemorragia/etiologia , Estudos Retrospectivos , Resultado do Tratamento
8.
Medicina (Kaunas) ; 59(6)2023 Jun 11.
Artigo em Inglês | MEDLINE | ID: mdl-37374330

RESUMO

Background and Objectives: Sutureless aortic valve prostheses have presented favorable hemodynamic performance while facilitating minimally invasive access approaches. As the population ages, the number of patients at risk for aortic valve reoperation constantly increases. The aim of the present study is to present our single-center experience in sutureless aortic valve replacement (SU-AVR) in reoperations. Materials and Methods: The data of 18 consecutive patients who underwent SU-AVR in a reoperation between May 2020 and January 2023 were retrospectively analyzed. Results: The mean age of the patients was 67.9 ± 11.1 years; patients showed a moderate-risk profile with a median logistic EuroSCORE II of 7.8 (IQR of 3.8-32.0) %. The implantation of the Perceval S prosthesis was technically successful in all patients. The mean cardiopulmonary bypass time was 103.3 ± 50.0 min, and the cross-clamp time was 69.1 ± 38.8 min. No patients required a permanent pacemaker implantation. The postoperative gradient was 7.3 ± 2.4 mmHg, and no cases of paravalvular leakage were observed. There was one case of intraprocedural death, while the thirty-day mortality was 11%. Conclusions: Sutureless bioprosthetic valves tend to simplify the surgical procedure of a redo AVR. By maximizing the effective orifice area, sutureless valves may present an important advantage, being a safe and effective alternative not only to traditional surgical prostheses but also to transcatheter valve-in-valve approaches in select cases.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Humanos , Pessoa de Meia-Idade , Idoso , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Estudos Retrospectivos , Resultado do Tratamento , Desenho de Prótese
9.
Br J Surg ; 109(11): 1053-1062, 2022 10 14.
Artigo em Inglês | MEDLINE | ID: mdl-35945894

RESUMO

BACKGROUND: Machine learning is a set of models and methods that can automatically detect patterns in vast amounts of data, extract information, and use it to perform decision-making under uncertain conditions. The potential of machine learning is significant, and breast surgeons must strive to be informed with up-to-date knowledge and its applications. METHODS: A systematic database search of Embase, MEDLINE, the Cochrane database, and Google Scholar, from inception to December 2021, was conducted of original articles that explored the use of machine learning and/or artificial intelligence in breast surgery in EMBASE, MEDLINE, Cochrane database and Google Scholar. RESULTS: The search yielded 477 articles, of which 14 studies were included in this review, featuring 73 847 patients. Four main areas of machine learning application were identified: predictive modelling of surgical outcomes; breast imaging-based context; screening and triaging of patients with breast cancer; and as network utility for detection. There is evident value of machine learning in preoperative planning and in providing information for surgery both in a cancer and an aesthetic context. Machine learning outperformed traditional statistical modelling in all studies for predicting mortality, morbidity, and quality of life outcomes. Machine learning patterns and associations could support planning, anatomical visualization, and surgical navigation. CONCLUSION: Machine learning demonstrated promising applications for improving breast surgery outcomes and patient-centred care. Neveretheless, there remain important limitations and ethical concerns relating to implementing artificial intelligence into everyday surgical practices.


Assuntos
Inteligência Artificial , Neoplasias da Mama , Neoplasias da Mama/cirurgia , Bases de Dados Factuais , Feminino , Humanos , Aprendizado de Máquina , Qualidade de Vida
10.
Artif Organs ; 46(8): 1689-1694, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35377470

RESUMO

BACKGROUND: With the rapid development of mechanical circulatory support technologies, patients presenting with cardiogenic shock have gained access to various treatment opportunities which were not until recently available. The Impella® pump (Abiomed, Danvers, USA) is a minimally invasive device which provides excellent left ventricular unloading and full circulatory support. The aim of the study was to review our center's experience with Impella® and to analyze the major adverse events associated with the device. METHODS: From January 2020 to January 2022, a total of 32 patients underwent Impella® implantation at our center for various indications. RESULTS: The mean age at surgery was 60.3 ± 12.4 years and 9.4% were female. All patients presented with acute cardiogenic shock in INTERMACS Class I (53.1%) and INTERMACS Class II (46.9%). Twenty-six patients (81.25%) out of the whole cohort have been mobilized on Impella® support. Seventeen patients (53.1%) have been weaned from the Impella® support and 10 patients (31.3%) have been bridged to durable LVAD. The median time on Impella® was 7 days (IQR 5.0-11.0). 30-day mortality was 37.5%, with 56.25% survival until hospital discharge. Only one patient developed vascular complications consisting of arm hypoperfusion. There were no cases of stroke on Impella® support. CONCLUSION: The Impella® axial-flow pump seems an appropriate therapeutic option for patients with acute cardiogenic shock requiring partial or full hemodynamic support. It also provides sufficient left ventricular unloading to allow full mobilization and neurological assessment of the patients. Furthermore, Impella® offers a high rate of myocardial recovery.


Assuntos
Coração Auxiliar , Choque Cardiogênico , Feminino , Coração Auxiliar/efeitos adversos , Humanos , Masculino , Sistema de Registros , Estudos Retrospectivos , Choque Cardiogênico/etiologia , Choque Cardiogênico/cirurgia , Resultado do Tratamento
11.
Artif Organs ; 46(5): 953-963, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-34931335

RESUMO

BACKGROUND: Mitral valve regurgitation (MR) is a common finding in patients with end-stage heart failure. The aim of the study was to analyze the impact of preoperative moderate-to-severe MR on postoperative outcomes and survival after durable left-ventricular assist device (LVAD) implantation. METHODS: From August 2010 to May 2021, 246 patients underwent a durable LVAD implantation. We stratified the patients into two groups: Group A (n = 109) presented with MR 0-I°, and Group B presented with MR II-III° (n = 137). MR II-III° was defined according to the current recommendations (i.e., vena contracta ≥ 7 mm, regurgitation volume ≥ 30 ml or effective regurgitation orifice area ≥ 20 mm2 ). RESULTS: Significantly more patients in Group B suffered from pulmonary hypertension and presented with chronic obstructive lung disease. We observed significantly higher rates of tricuspid regurgitation (TR) II-III° in Group B (76.1%) versus Group A (14.8%) (p < 0.001) and TR III° in Group B (30.4%) versus Group A (3.7%) (p < 0.001). There was no difference in the incidence of right heart failure between the groups. Within our cohort, the in-hospital, 1-year, 3-year, and 5-year mortality was 22.4%, 32.1%, 50.7%, and 64.4%, respectively. Group B showed significantly worse overall survival (p = 0.05). Patients with preoperative TR II-III° had a significantly worse survival than those with TR 0-I° (p = 0.048). In patients presenting with MR II-III°, we discovered that TR III° seems to predict both in-hospital and mid-term mortality. CONCLUSION: MR II-III° negatively affects the outcomes in patients requiring LVAD implantation. Persisting MR II-III° is an independent predictor of mortality. Patients with concomitant preoperative TR II-III° are at increased risk of developing postoperative major adverse events. Addressing the MR might be considered for these patients.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Insuficiência da Valva Mitral , Insuficiência da Valva Tricúspide , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/epidemiologia , Insuficiência Cardíaca/cirurgia , Coração Auxiliar/efeitos adversos , Humanos , Insuficiência da Valva Mitral/complicações , Insuficiência da Valva Mitral/cirurgia , Estudos Retrospectivos , Resultado do Tratamento
12.
Artif Organs ; 46(1): 95-105, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34694644

RESUMO

BACKGROUND: The use of left ventricular assist devices (LVAD) in patients with advance heart failure is still associated with an important risk of immune dysregulation and infections. The aim of this study was to determine whether extracorporeal blood purification using the CytoSorb device benefits patients after LVAD implantation in terms of complications and overall survival. MATERIALS AND METHODS: Between August 2010 and January 2020, 207 consecutive patients underwent LVAD implantation, of whom 72 underwent CytoSorb therapy and 135 did not. Overall survival, major adverse events, and laboratory parameters were compared between 112 propensity score-matched patients (CytoSorb: 72 patients; non-CytoSorb: 40 patients). RESULTS: WBC (p = .033), CRP (p = .001), and IL-6 (p < .001), significantly increased with LVAD implantation, while CytoSorb did not influence this response. In-hospital mortality and overall survival during follow-up were similar with CytoSorb. However, patients treated with CytoSorb were more likely to develop respiratory failure (54.2% vs. 30.0%, p = .024), need mechanical ventilation for longer than 6 days post-implant (50.0% vs. 27.5%, p = .035), and require tracheostomy during hospitalization (31.9% vs. 12.5%, p = .040). No other significant differences were observed with regard to major adverse events during follow-up. CONCLUSIONS: Overall, our results showed that CytoSorb might not convey a significant morbidity or mortality benefit for patients undergoing LVAD implantation.


Assuntos
Insuficiência Cardíaca/terapia , Coração Auxiliar/efeitos adversos , Hemofiltração/instrumentação , Proteína C-Reativa/análise , Feminino , Hemofiltração/métodos , Mortalidade Hospitalar , Humanos , Interleucina-6/sangue , Contagem de Leucócitos , Masculino , Pessoa de Meia-Idade , Respiração Artificial/estatística & dados numéricos , Insuficiência Respiratória , Estudos Retrospectivos , Traqueotomia/estatística & dados numéricos , Resultado do Tratamento
13.
J Card Surg ; 37(1): 258-259, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34318536

RESUMO

Redo mitral valve replacement remains the standard treatment for recurrent mitral valve disease. Most patients referred for a redo surgery in the western world are older and present with multiple comorbidities. With the successful broad implementation of anti-infective treatment, rheumatic mitral valve disease has become highly uncommon. Nonetheless, rheumatic heart disease is still thriving in developing countries causing the most severe mitral valve conditions. The guidelines are there to help us in our decision-making process, but the actual decision has to be made based on each patients' individual criteria.


Assuntos
Doenças das Valvas Cardíacas , Implante de Prótese de Valva Cardíaca , Cardiopatia Reumática , Países em Desenvolvimento , Doenças das Valvas Cardíacas/cirurgia , Humanos , Valva Mitral/cirurgia , Reoperação , Cardiopatia Reumática/cirurgia , Resultado do Tratamento
14.
J Card Surg ; 37(4): 1121-1124, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35076101

RESUMO

Since the development of endoscopic vision in the late 1970s, the implementation of minimally invasive surgical methods has been rapidly progressing throughout a wide range of surgical disciplines, including cardiovascular surgery. The benefits of minimally invasive procedures including a reduction in operative trauma and postoperative morbidity, have been well-documented and compared to open-heart procedures, eventually becoming the preferred modality of treatment by many centers. Due to the cost ineffectiveness of the robotic systems for numerous institutions, new technologies have been developed to provide the advantages of robotic surgical systems at a lower price, thus making them more widely available. In this paper, we aimed to share our first experiences with Artisential® surgeon-powered robotic instruments and review their general advantages compared to conventional and robotic devices.


Assuntos
Procedimentos Cirúrgicos Robóticos , Robótica , Cirurgiões , Endoscopia/métodos , Humanos , Procedimentos Cirúrgicos Minimamente Invasivos , Procedimentos Cirúrgicos Robóticos/métodos , Robótica/métodos
15.
Minim Invasive Ther Allied Technol ; 31(6): 909-916, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34915823

RESUMO

BACKGROUND: We aimed to evaluate the outcomes of transapical and transaortic transcatheter aortic valve replacement (TAVR) in high-risk patients who were not suitable for transfemoral access and had a logistic EuroSCORE-I ≥ 25% and Society of Thoracic Surgeons (STS) score >6%. 'STS/ACC TAVR In-Hospital Mortality Risk App' was evaluated. MATERIAL AND METHODS: Between January 2016 and May 2020, 126 patients at very high risk for aortic valve replacement underwent transapical (n = 121) or transaortic (n = 5) transcatheter aortic valve replacement. TAVR was performed using SAPIEN 3™ or ACURATE TA™ prosthesis. RESULTS: The logistic EuroSCORE-I was 40.6 ± 14.0%, the STS-score 7.9 ± 4.6%, and STS/ACC-score 8.4 ± 3.4%. Valve implantation was successful in all patients. Operative, in-hospital and 30-days mortality, were 0, 7.9, and 13.5%, respectively. Survival was 72% at one year and 48% at four years. Expected/observed in-hospital mortality was 1.0 for the STS-score and 1.06 for the STS/ACC-score. Renal failure, low ejection fraction, and postoperative acute kidney injury, hemorrhage, and vascular complications were identified as independent predictors for 30-day mortality. CONCLUSIONS: Transapical and transaortic TAVR in high-risk patients unsuitable for transfemoral access is still a reasonable alternative in these patients. STS and STS/ACC-score appear to be highly accurate in predicting in-hospital mortality in high-risk patients undergoing TAVR.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Substituição da Valva Aórtica Transcateter , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
16.
Artif Organs ; 45(7): 706-716, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33350481

RESUMO

The use of left ventricular assist devices (LVADs) for advanced heart failure is becoming increasingly common. However, optimal timing and patient selection remain controversial. The aim of this study was to investigate outcomes of LVAD implantation for advanced heart failure in critically ill patients (INTERMACS 1 and 2). Between August 2010 and January 2020, 207 consecutive patients underwent LVAD implantation. Overall survival, major adverse events, and laboratory parameters were compared between patients in INTERMACS 1-2 (n = 107) and INTERMACS 3-5 (n = 100). Preoperative white blood cells, C-reactive protein, procalcitonin, bilirubin, alanine transaminase, and lactate dehydrogenase were all significantly higher in INTERMACS 1-2 when compared to INTERMACS 3-5 (P < .05). During hospitalization following LVAD implantation, patients in INTERMACS 1-2 were more likely to develop major infections (41.1% vs. 23.0%, P = .005), respiratory failure (57.9% vs. 25.0%, P < .001), mild (20.6% vs. 8.0%, P = .010), and moderate (31.8% vs. 7.0%, P < .001) right heart failure, and acute renal dysfunction (56.1% vs. 6.0%, P < .001). During a median follow-up of 2.00 years (interquartile range (IQR) 0.24-3.39 years), they had a higher incidence of thoracic (15.9% vs. 4.0%, P = .005) and gastrointestinal bleeding (21.5% vs. 11.0%, P = .042), as well as right heart failure (18.7% vs. 1%, P < .001). Risk of death was significantly higher in the INTERMACS 1-2 group (hazards ratio (HR) 1.64, 95% CI 1.12-2.40, P = .011). LVAD implantation in critically ill patients is associated with increased morbidity and mortality. Our results suggest that decision for LVAD should be not be delayed until INTERMACS 1 and 2 levels whenever possible.


Assuntos
Estado Terminal/classificação , Insuficiência Cardíaca/classificação , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/terapia , Coração Auxiliar , Injúria Renal Aguda/epidemiologia , Idoso , Feminino , Seguimentos , Hemorragia/epidemiologia , Humanos , Infecções/epidemiologia , Masculino , Pessoa de Meia-Idade , Insuficiência Respiratória/epidemiologia , Estudos Retrospectivos
17.
J Card Surg ; 36(7): 2476-2485, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33797789

RESUMO

INTRODUCTION: Primary cardiac sarcomas (PCSs) are an extremely rare and aggressive type of malignancies that have been described only by a limited number of observational studies. This study aimed to evaluate the currently existing evidence comparing surgical to multimodality treatment of PCS. METHODS: We systematically reviewed Embase, MEDLINE, Cochrane Database, and Google Scholar, from inception to December 2020, for original articles about surgical and multimodality treatment of PCS. The outcomes included were mortality at various time points, resection margin status, and mean estimated survival. The pooled treatment effects were calculated using a random-effects model. RESULTS: Ten studies including a total of 1570 patients met our inclusion criteria. Surgery was associated with significantly lower mortality when compared to conservative treatment at 1, 2, and 3 years, whereas no significant difference was found at 5 years. Furthermore, multimodality treatment showed significantly lower mortality at 1 year when compared to surgery alone, but not at 2 and 5 years. We found no difference in mortality between angiosarcomas and other PCS subtypes. CONCLUSION: Overall, surgery was found to provide a significant mortality advantage to PCS patients up to 3 years following treatment. Multimodality treatment might be of additional benefit, although only within the first year. Prospective randomized studies are needed to further explore these differences in the treatment of PCS.


Assuntos
Neoplasias Cardíacas , Sarcoma , Terapia Combinada , Neoplasias Cardíacas/cirurgia , Humanos , Estudos Prospectivos , Sarcoma/cirurgia
18.
J Card Surg ; 36(9): 3195-3204, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34227147

RESUMO

INTRODUCTION: Redo surgical mitral valve replacement (SMVR) remains the gold standard treatment in patients with a history of mitral valve surgery presenting with recurrent mitral valve pathologies. Whilst this procedure is demanding, it is an inevitable intervention for some indications, such as infective endocarditis, thrombosis, or multivalve procedures. In this study, we aim to evaluate our institutional experience with SMVR on a real-life cohort, identifying the factors that contribute to poor surgical outcomes whilst avoiding selection bias. METHODS: Between March 2012 and November 2020, 58 consecutive high-risk patients underwent a redo SMVR at our institution. The primary endpoints of this study were 30-day and 1-year mortality. The secondary endpoint was the development of any postoperative adverse events. We analyzed and compared the survival in patients undergoing an isolated SMVR and in those that required at least one concomitant procedure. RESULTS: The overall operative, 30-day, and 1-year mortality were 3.4%, 22.4%, and 25.9%, respectively. The mortality in patients undergoing isolated SMVR was significantly lower than in patients requiring concomitant procedures. The multivariable regression model showed that NYHA Class IV, infective endocarditis, and postoperative dialysis were significantly associated with 30-day mortality. Society of Thoracic Surgeons Score, infective endocarditis, concomitant procedures, and mechanical valve implantation appeared to predict long-term mortality. CONCLUSION: This study illustrates that SMVR after prior mitral valve surgery presents a demanding procedure with high operative risk, significant mortality, and morbidity. Whilst this procedure is inevitable for some indications, a careful patient selection and risk stratification provides acceptable surgical results in this cohort.


Assuntos
Implante de Prótese de Valva Cardíaca , Valva Mitral , Humanos , Valva Mitral/cirurgia , Diálise Renal , Reoperação , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento
19.
J Card Surg ; 36(1): 286-289, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33085137

RESUMO

In rare cases of extensive aortic root or mitral valve infective endocarditis (IE), severe calcification of the aortic and mitral valves, or double-valve procedures in patients with small aortic and mitral annuli, surgical reconstruction of the intervalvular fibrous body (IVFB) is required. A high mortality is generally associated with this procedure, and it is frequently avoided by surgeons due to a lack of experience. It is crucial to radically resect all tissues that are severely affected by IE to prevent recurrence in the patient. Our experience with the Commando procedure in patients with extensive double-valve IE involving the IVFB is presented in this article.


Assuntos
Endocardite , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Procedimentos de Cirurgia Plástica , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Endocardite/cirurgia , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia
20.
J Card Surg ; 36(4): 1226-1231, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33491207

RESUMO

INTRODUCTION: Transcatheter aortic valve implantation (TAVI) techniques are increasingly being adopted into clinical routine for various risk groups. Coronary artery disease (CAD) is seen in up to 75% of patients with severe aortic valve stenosis (AS) presenting with typical angina pectoris. Due to high mortality rates and procedural complications in these patients, a hybrid concept of simultaneous transaortic TAVI and off-pump coronary artery bypass (OPCAB) can be a feasible treatment option. METHODS: Between April 2014 and July 2020, 10 consecutive high-risk patients underwent concomitant transaortic TAVI and OPCAB at our institution. All indications were discussed in Heart Team and decisions were made based on patients' comorbidities and complexity of CAD. The study endpoints were 30-day mortality, device success, and development of postoperative adverse events defined by the Valve Academic Research Consorium. RESULTS: The mean age of the patients was 77.9 ± 7.1 years old. All patients presented with multiple comorbidities (mean logistic EuroSCORE 26.5 ± 12.3%, median EuroSCORE II 5.13% [interquartile range 4.2-9.5], mean STS-Score 6.04 ± 1.6%). Five patients (50%) presented with porcelain aorta. No conversion to conventional procedures was needed. 30-day mortality occurred in one patient (10%). Complete revascularization was achieved in seven (70%) of the patients. Device success rate was 100%. No paravalvular leakage was detected. No stroke, myocardial infarction or vascular complications were observed. CONCLUSIONS: A hybrid approach combining transaortic TAVI and OPCAB might be a safe and feasible method of treatment in high-risk patients presenting with severe AS and CAD who are not eligible for conventional surgical or interventional solutions.


Assuntos
Estenose da Valva Aórtica , Ponte de Artéria Coronária sem Circulação Extracorpórea , Doença da Artéria Coronariana , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Doença da Artéria Coronariana/cirurgia , Humanos , Fatores de Risco , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa