Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 52
Filtrar
1.
Circulation ; 148(14): 1113-1126, 2023 10 03.
Artigo em Inglês | MEDLINE | ID: mdl-37782695

RESUMO

The Shock Academic Research Consortium is a multi-stakeholder group, including representatives from the US Food and Drug Administration and other government agencies, industry, and payers, convened to develop pragmatic consensus definitions useful for the evaluation of clinical trials enrolling patients with cardiogenic shock, including trials evaluating mechanical circulatory support devices. Several in-person and virtual meetings were convened between 2020 and 2022 to discuss the need for developing the standardized definitions required for evaluation of mechanical circulatory support devices in clinical trials for cardiogenic shock patients. The expert panel identified key concepts and topics by performing literature reviews, including previous clinical trials, while recognizing current challenges and the need to advance evidence-based practice and statistical analysis to support future clinical trials. For each category, a lead (primary) author was assigned to perform a literature search and draft a proposed definition, which was presented to the subgroup. These definitions were further modified after feedback from the expert panel meetings until a consensus was reached. This manuscript summarizes the expert panel recommendations focused on outcome definitions, including efficacy and safety.


Assuntos
Implante de Prótese de Valva Cardíaca , Coração Auxiliar , Humanos , Choque Cardiogênico/terapia , Choque Cardiogênico/cirurgia , Projetos de Pesquisa
2.
Circulation ; 137(24): 2635-2650, 2018 06 12.
Artigo em Inglês | MEDLINE | ID: mdl-29891620

RESUMO

The Academic Research Consortium (ARC)-2 initiative revisited the clinical and angiographic end point definitions in coronary device trials, proposed in 2007, to make them more suitable for use in clinical trials that include increasingly complex lesion and patient populations and incorporate novel devices such as bioresorbable vascular scaffolds. In addition, recommendations for the incorporation of patient-related outcomes in clinical trials are proposed. Academic Research Consortium-2 is a collaborative effort between academic research organizations in the United States and Europe, device manufacturers, and European, US, and Asian regulatory bodies. Several in-person meetings were held to discuss the changes that have occurred in the device landscape and in clinical trials and regulatory pathways in the last decade. The consensus-based end point definitions in this document are endorsed by the stakeholders of this document and strongly advocated for clinical trial purposes. This Academic Research Consortium-2 document provides further standardization of end point definitions for coronary device trials, incorporating advances in technology and knowledge. Their use will aid interpretation of trial outcomes and comparison among studies, thus facilitating the evaluation of the safety and effectiveness of these devices.


Assuntos
Bioprótese/normas , Implante de Prótese Vascular/normas , Prótese Vascular/normas , Vasos Coronários/cirurgia , Desenho de Prótese/normas , Stents/normas , Estenose da Valva Aórtica , Ensaios Clínicos como Assunto , Consenso , Humanos
3.
Eur Heart J ; 39(23): 2192-2207, 2018 06 14.
Artigo em Inglês | MEDLINE | ID: mdl-29897428

RESUMO

The Academic Research Consortium (ARC)-2 initiative revisited the clinical and angiographic end point definitions in coronary device trials, proposed in 2007, to make them more suitable for use in clinical trials that include increasingly complex lesion and patient populations and incorporate novel devices such as bioresorbable vascular scaffolds. In addition, recommendations for the incorporation of patient-related outcomes in clinical trials are proposed. Academic Research Consortium-2 is a collaborative effort between academic research organizations in the United States and Europe, device manufacturers, and European, US, and Asian regulatory bodies. Several in-person meetings were held to discuss the changes that have occurred in the device landscape and in clinical trials and regulatory pathways in the last decade. The consensus-based end point definitions in this document are endorsed by the stakeholders of this document and strongly advocated for clinical trial purposes. This Academic Research Consortium-2 document provides further standardization of end point definitions for coronary device trials, incorporating advances in technology and knowledge. Their use will aid interpretation of trial outcomes and comparison among studies, thus facilitating the evaluation of the safety and effectiveness of these devices.


Assuntos
Ensaios Clínicos como Assunto , Doença da Artéria Coronariana/terapia , Equipamentos e Provisões , Medidas de Resultados Relatados pelo Paciente , Implantes Absorvíveis , Ásia , Europa (Continente) , Humanos , Avaliação de Resultados em Cuidados de Saúde , Stents , Alicerces Teciduais , Estados Unidos
4.
J Biopharm Stat ; 26(6): 1136-1145, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27540636

RESUMO

Regulatory decisions are made based on the assessment of risk and benefit of medical devices at the time of pre-market approval and subsequently, when post-market risk-benefit balance needs reevaluation. Such assessments depend on scientific evidence obtained from pre-market studies, post-approval studies, post-market surveillance studies, patient perspective information, as well as other real world data such as national and international registries. Such registries provide real world evidence and are playing a more and more important role in enhancing the safety and effectiveness evaluation of medical devices. While these registries provide large quantities of data reflecting real world practice and can potentially reduce the cost of clinical trials, challenges arise concerning (1) data quality adequate for regulatory decision-making, (2) bias introduced at every stage and aspect of study, (3) scientific validity of study designs, and (4) reliability and interpretability of study results. This article will discuss related statistical and regulatory challenges and opportunities with examples encountered in medical device regulatory reviews.


Assuntos
Aprovação de Equipamentos , Regulamentação Governamental , Sistema de Registros , Viés , Confiabilidade dos Dados , Tomada de Decisões , Humanos , Reprodutibilidade dos Testes , Projetos de Pesquisa , Medição de Risco
6.
Cardiovasc Revasc Med ; 60: 95-101, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37778922

RESUMO

BACKGROUND/PURPOSE: There has been increasing emphasis on the development of new technology to mitigate unmet clinical needs in cardiovascular disease. This emphasis results in part from recognition that many devices, although being initially developed in the United States, were studied, and then eventually approved abroad before being returned to the U.S. for clinical application. The FDA (Food and Drug Administration) guidance document on Early Feasibility Studies (EFS) and then the 21st Century Cures Act from 2013 to 2016 focused on these issues. MATERIALS/METHODS: There are multiple components of medical device translational pathways to be considered in continuing to reach the goal of providing early access to safe and effective products to the U.S. POPULATION: This review article documents the various stages from early idea innovation to device design and iteration to clinical testing and then potential approval and application in the wide clinical practice of cardiovascular health care. RESULTS: The CDRH (Centers for Devices and Radiological Health) has focused on key components including EFS, Breakthrough Devices Program, Total Product Life Cycle, the Unique Device Identification Program, the establishment of a Digital Health Center of Excellence, and leveraging Collaborative Communities. Each of these initiatives focuses on improving the Medical Device Development Ecosystem. CONCLUSIONS: Major changes in device translational research have improved the device research climate in the United States. Goals remain including increased training and education for constituencies aspiring to work in the field of device development and regulation as part of a continuous health care learning system.


Assuntos
Doenças Cardiovasculares , Ecossistema , Estados Unidos , Humanos , Aprovação de Equipamentos , Doenças Cardiovasculares/diagnóstico , Doenças Cardiovasculares/terapia , United States Food and Drug Administration , Estudos de Viabilidade
7.
JAMA Cardiol ; 8(8): 744-754, 2023 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-37342056

RESUMO

Importance: Recent studies have produced inconsistent findings regarding the outcomes of the percutaneous microaxial left ventricular assist device (LVAD) during acute myocardial infarction with cardiogenic shock (AMICS). Objective: To compare the percutaneous microaxial LVAD vs alternative treatments among patients presenting with AMICS using observational analyses of administrative data. Design, Setting, and Participants: This comparative effectiveness research study used Medicare fee-for-service claims of patients admitted with AMICS undergoing percutaneous coronary intervention from October 1, 2015, through December 31, 2019. Treatment strategies were compared using (1) inverse probability of treatment weighting to estimate the effect of different baseline treatments in the overall population; (2) instrumental variable analysis to determine the effectiveness of the percutaneous microaxial LVAD among patients whose treatment was influenced by cross-sectional institutional practice patterns; (3) an instrumented difference-in-differences analysis to determine the effectiveness of treatment among patients whose treatment was influenced by longitudinal changes in institutional practice patterns; and (4) a grace period approach to determine the effectiveness of initiating the percutaneous microaxial LVAD within 2 days of percutaneous coronary intervention. Analysis took place between March 2021 and December 2022. Interventions: Percutaneous microaxial LVAD vs alternative treatments (including medical therapy and intra-aortic balloon pump). Main Outcomes and Measures: Thirty-day all-cause mortality and readmissions. Results: Of 23 478 patients, 14 264 (60.8%) were male and the mean (SD) age was 73.9 (9.8) years. In the inverse probability of treatment weighting analysis and grace period approaches, treatment with percutaneous microaxial LVAD was associated with a higher risk-adjusted 30-day mortality (risk difference, 14.9%; 95% CI, 12.9%-17.0%). However, patients receiving the percutaneous microaxial LVAD had a higher frequency of factors associated with severe illness, suggesting possible confounding by measures of illness severity not available in the data. In the instrumental variable analysis, 30-day mortality was also higher with percutaneous microaxial LVAD, but patient and hospital characteristics differed across levels of the instrumental variable, suggesting possible confounding by unmeasured variables (risk difference, 13.5%; 95% CI, 3.9%-23.2%). In the instrumented difference-in-differences analysis, the association between the percutaneous microaxial LVAD and mortality was imprecise, and differences in trends in characteristics between hospitals with different percutaneous microaxial LVAD use suggested potential assumption violations. Conclusions: In observational analyses comparing the percutaneous microaxial LVAD to alternative treatments among patients with AMICS, the percutaneous microaxial LVAD was associated with worse outcomes in some analyses, while in other analyses, the association was too imprecise to draw meaningful conclusions. However, the distribution of patient and institutional characteristics between treatment groups or groups defined by institutional differences in treatment use, including changes in use over time, combined with clinical knowledge of illness severity factors not captured in the data, suggested violations of key assumptions that are needed for valid causal inference with different observational analyses. Randomized clinical trials of mechanical support devices will allow valid comparisons across candidate treatment strategies and help resolve ongoing controversies.


Assuntos
Coração Auxiliar , Infarto do Miocárdio , Humanos , Masculino , Idoso , Estados Unidos/epidemiologia , Feminino , Choque Cardiogênico/etiologia , Choque Cardiogênico/terapia , Choque Cardiogênico/mortalidade , Coração Auxiliar/efeitos adversos , Estudos Transversais , Medicare , Infarto do Miocárdio/complicações , Infarto do Miocárdio/terapia , Infarto do Miocárdio/fisiopatologia
9.
Am J Ther ; 19(4): 248-54, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22668602

RESUMO

Implantable cardiac devices have become the mainstay of the treatment of patients with heart disease. However, data regarding their reliability and, inferentially, safety have been called into question. We reviewed annual reports submitted to the Food and Drug Administration Office of Device Evaluation by device manufacturers from 2003 to 2007. The annual number of implantable cardiac defibrillators (ICDs) and cardiac resynchronization therapy defibrillator (CRT-D) implants, explants, and returned devices were tabulated along with the cumulative (Cum) number of implants for each device. We derived an annual explantation rate (AER) defined as the ratio of the annual number of explants less the number of normal battery depletions/Cum (×1000). From 2003 to 2007, 256,392 CRT-D and 459,300 ICD devices were implanted in the United States. The overall mean (±SD) AERs for ICD and CRT-D devices were, respectively, 49.5 (15.6) per 1000 ICD devices and 82.6 (35.5) per 1000 CRT-D devices. The AER for each device type significantly decreased over the study period (P for trend <0.001) although the AER for CRT-D devices was 38% higher than that for ICD devices (P < 0.001). On average, 20.3% of CRT-D devices and 22.6% of ICD devices were returned to the manufacturer for analysis after explantation. The rates of explanted CRT-D and ICD devices decreased from 2003 to 2007. Notwithstanding this favorable trend, the AER for CRT-D devices was higher than that for ICD devices. Improved methods for tracking individual device histories are needed for more precise estimates of the risk of device explantation for suspected malfunction. The proportion of devices returned to the manufacturer is suboptimal and needs to be improved to better understand the mechanisms of device malfunction.


Assuntos
Dispositivos de Terapia de Ressincronização Cardíaca/normas , Desfibriladores Implantáveis/normas , Vigilância de Produtos Comercializados/métodos , Falha de Equipamento , Humanos , Medição de Risco/métodos , Estados Unidos , United States Food and Drug Administration
10.
J Am Coll Cardiol ; 80(5): 527-544, 2022 08 02.
Artigo em Inglês | MEDLINE | ID: mdl-35902177

RESUMO

A virtual workshop was organized by the Heart Valve Collaboratory to identify areas of expert consensus, areas of disagreement, and evidence gaps related to bioprosthetic aortic valve hemodynamics. Impaired functional performance of bioprosthetic aortic valve replacement is associated with adverse patient outcomes; however, this assessment is complicated by the lack of standardization for labelling, definitions, and measurement techniques, both after surgical and transcatheter valve replacement. Echocardiography remains the standard assessment methodology because of its ease of performance, widespread availability, ability to do serial measurements over time, and correlation with outcomes. Management of a high gradient after replacement requires integration of the patient's clinical status, physical examination, and multimodality imaging in addition to shared patient decisions regarding treatment options. Future priorities that are underway include efforts to standardize prosthesis sizing and labelling for both surgical and transcatheter valves as well as trials to characterize the consequences of adverse hemodynamics.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Ecocardiografia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Hemodinâmica , Humanos , Desenho de Prótese , Falha de Prótese , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
12.
Catheter Cardiovasc Interv ; 76(4): E126-9, 2010 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-20862708

RESUMO

Live case presentations are increasingly common at interventional cardiology conferences. Taking advantage of significant advances in communication technology, broadcasts of procedures can be viewed as an extension of traditional medical education targeted to large groups of practitioners. However, there are important ethical, commercial, and patient safety issues associated with live cases that deserve attention. Use of investigational devices in live case demonstrations is subject to review and approval by FDA's Center for Devices and Radiological Health (CDRH), and the outcomes of patients participating in live cases are considered in the overall clinical study results. This article discusses CDRH's regulatory view of live case presentations with a focus on patient safety, clinical trial integrity, and concerns regarding improper medical device promotion.


Assuntos
Cardiologia/legislação & jurisprudência , Aprovação de Equipamentos/legislação & jurisprudência , Aprovação de Equipamentos/normas , Educação Médica/legislação & jurisprudência , Consulta Remota/legislação & jurisprudência , Consulta Remota/normas , Cardiologia/normas , Educação Médica/ética , Educação Médica/normas , Humanos , Terapias em Estudo/normas , Estados Unidos
13.
Am J Ther ; 17(1): 2-7, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20038828

RESUMO

The quality of clinical data submitted by manufacturers to support Food and Drug Administration cardiovascular device premarket approval (PMA) applications varies widely and formal quality assessment has not been previously performed. This study evaluated all original cardiovascular device PMAs with Food and Drug Administration decisions between January 1, 2000, and December 31, 2007, to assess the quality of clinical investigations submitted by manufacturers. Effectiveness and safety end points were judged high quality if they were clearly defined and associated with a specific time point for analysis. Subject accounting was high quality if 90% or greater of the original cohort was accounted for at study conclusion. In total, 88 cardiovascular device PMAs (77.3% permanent implants), 132 clinical studies, 37,328 study subjects (age 61.0 +/- 14.5 years, 33.9% women, 86.3% white), and 29,408 device recipients were analyzed. All PMAs contained clinical data. Primary effectiveness end points, primary safety end points, and subject accounting were deemed high quality in 81.8%, 60.2%, and 77.3% of pivotal studies, respectively. Key cardiovascular comorbidities (coronary artery disease 51.1%, diabetes 36.6%, hypertension 35.2%, heart failure 37.5%, tobacco use 31.8%) and race (14.8%) were infrequently reported, and studies rarely included patients younger than 18 years of age (10.2% of studies). Poorly defined safety and effectiveness end points, poor patient accounting, and incomplete collection of important patient comorbidities make device safety and effectiveness assessments more challenging. Women, pediatric, and nonwhite populations are underrepresented in premarket cardiovascular clinical trials. Manufacturers, regulators, and the clinical community should collaborate to address these study shortcomings to ensure that patients are treated with reliable, safe, and clinically useful medical devices.


Assuntos
Doenças Cardiovasculares/terapia , Ensaios Clínicos como Assunto/normas , Aprovação de Equipamentos , Adolescente , Adulto , Fatores Etários , Idoso , Viés , Ensaios Clínicos como Assunto/métodos , Determinação de Ponto Final , Segurança de Equipamentos , Equipamentos e Provisões , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Seleção de Pacientes , Estados Unidos , United States Food and Drug Administration , Adulto Jovem
14.
J Am Coll Cardiol ; 76(23): 2786-2794, 2020 12 08.
Artigo em Inglês | MEDLINE | ID: mdl-33272373

RESUMO

The development of technology to treat unmet clinical patient needs in the United States has been an important focus for the U.S. Food and Drug Administration and the 2016 Congressional 21st Century Cures Act. In response, a program of early feasibility studies (EFS) has been developed. One of the important issues has been the outmigration of the development and testing of medical devices from the United States. The EFS committee has developed and implemented processes to address issues to develop strategies for early treatment of these patient groups. Initial implementation of the U.S. Food and Drug Administration EFS program has been successful, but residual significant problems have hindered the opportunity to take full advantage of the program. These include delays in gaining Institutional Review Board approval, timeliness of budget and contractual negotiations, and lack of access to and enrollment of study subjects. This paper reviews improvements that have been made to the U.S. EFS ecosystem and outlines potential approaches to address remaining impediments to program success.


Assuntos
Aprovação de Equipamentos , Coração Auxiliar , Estudos de Viabilidade , Humanos , Estados Unidos
15.
J Vasc Surg ; 50(6): 1474-6, 2009 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-19897334

RESUMO

The article by Conte et al.(1) on behalf of the Society for Vascular Surgery (SVS) in this issue of the Journal of Vascular Surgery provides guidelines for improving the consistency and interpretability of clinical trials intended to evaluate treatment options for patients with critical limb ischemia (CLI). This article identifies a number of key challenges with conducting and comparing CLI trials, including the wide spectrum of clinical presentations that CLI encompasses, the use of disparate eligibility criteria and endpoint measurements, and logistical and economic considerations that can limit study initiation and completion. The authors propose definitions for a number of performance goals derived from historical surgical literature as a means of reducing the negative impact of these factors. The current editorial reviews aspects of this proposal from the perspective of the authors in terms of their understanding of the statutory obligations of the U.S. Food and Drug Administration (FDA) to regulate the marketing of cardiovascular devices based on valid scientific evidence.


Assuntos
Cateterismo Periférico/instrumentação , Ensaios Clínicos Controlados como Assunto , Aprovação de Equipamentos , Extremidades/irrigação sanguínea , Isquemia/terapia , United States Food and Drug Administration , Procedimentos Cirúrgicos Vasculares/instrumentação , Comitês Consultivos , Cateterismo Periférico/efeitos adversos , Estado Terminal , Desenho de Equipamento , Segurança de Equipamentos , Medicina Baseada em Evidências , Humanos , Isquemia/cirurgia , Guias de Prática Clínica como Assunto , Projetos de Pesquisa , Medição de Risco , Fatores de Risco , Sociedades Médicas , Resultado do Tratamento , Estados Unidos , Procedimentos Cirúrgicos Vasculares/efeitos adversos
16.
Circ Cardiovasc Qual Outcomes ; 12(6): e005420, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-31189406

RESUMO

Background Survival and health status (eg, symptoms and quality of life) are key outcomes in clinical trials of heart failure treatment. However, health status can only be recorded on survivors, potentially biasing treatment effect estimates when there is differential survival across treatment groups. Joint modeling of survival and health status can address this bias. Methods and Results We analyzed patient-level data from the PARTNER 1B trial (Placement of Aortic Transcatheter Valves) of transcatheter aortic valve replacement versus standard care. Health status was quantified with the Kansas City Cardiomyopathy Questionnaire (KCCQ) at randomization, 1, 6, and 12 months. We compared hazard ratios for survival and mean differences in KCCQ scores at 12 months using several models: the original growth curve model for KCCQ scores (ignoring death), separate Bayesian models for survival and KCCQ scores, and a Bayesian joint longitudinal-survival model fit to either 12 or 30 months of survival follow-up. The benefit of transcatheter aortic valve replacement on 12-month KCCQ scores was greatest in the joint-model fit to all survival data (mean difference, 33.7 points; 95% credible intervals [CrI], 24.2-42.4), followed by the joint-model fit to 12 months of survival follow-up (32.3 points; 95% CrI, 22.5-41.5), a Bayesian model without integrating death (30.4 points; 95% CrI, 21.4-39.3), and the original growth curve model (26.0 points; 95% CI, 18.7-33.3). At 12 months, the survival benefit of transcatheter aortic valve replacement was also greater in the joint model (hazard ratio, 0.50; 95% CrI, 0.32-0.73) than in the nonjoint Bayesian model (0.54; 95% CrI, 0.37-0.75) or the original Kaplan-Meier estimate (0.55; 95% CI, 0.40-0.74). Conclusions In patients with severe symptomatic aortic stenosis and prohibitive surgical risk, the estimated benefits of transcatheter aortic valve replacement on survival and health status compared with standard care were greater in joint Bayesian models than other approaches.


Assuntos
Estenose da Valva Aórtica/cirurgia , Nível de Saúde , Medidas de Resultados Relatados pelo Paciente , Qualidade de Vida , Ensaios Clínicos Controlados Aleatórios como Assunto , Projetos de Pesquisa , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/mortalidade , Teorema de Bayes , Determinação de Ponto Final , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Recuperação de Função Fisiológica , Índice de Gravidade de Doença , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
17.
JACC Heart Fail ; 7(11): 913-921, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31401097

RESUMO

The development of treatments for heart failure (HF) is challenged by burdensome clinical trials. Reducing the need for extensive data collection and increasing opportunities for data compatibility between trials may improve efficiency and reduce resource burden. The Heart Failure Collaboratory (HFC) multi-stakeholder consortium sought to create a lean case report form (CRF) for use in HF clinical trials evaluating cardiac devices. The HFC convened patients, clinicians, clinical researchers, the U.S. Food and Drug Administration (FDA), payers, industry partners, and statisticians to create a consensus core CRF. Eight recent clinical trial CRFs for the treatment of HF from 6 industry partners were analyzed. All CRF elements were systematically reviewed. Those elements deemed critical for data collection in HF clinical trials were used to construct the final, harmonized CRF. The original CRFs included 176 distinct data items covering demographics, vital signs, physical examination, medical history, laboratory and imaging testing, device therapy, medications, functional and quality of life assessment, and outcome events. The resulting, minimally inclusive CRF device contains 75 baseline data items and 6 events, with separate modular additions that can be used depending on the additional detail required for a particular intervention. The consensus electronic form is now freely available for use in clinical trials. Creation of a core CRF is important to improve clinical trial efficiency in HF device development in the United States. This living document intends to reduce clinical trial administrative burden, increase evidence integrity, and improve comparability of clinical data between trials.


Assuntos
Formulários como Assunto , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Prontuários Médicos , Humanos
18.
JACC Cardiovasc Interv ; 11(21): 2220-2225, 2018 11 12.
Artigo em Inglês | MEDLINE | ID: mdl-30409280

RESUMO

Performance of early feasibility studies in the United States can advance the goal of evaluating the safety and effectiveness of new devices aimed at unmet clinical needs and facilitating earlier access for U.S. patients to new technology. Early feasibility studies are an important component of the 21st Century Cures Act, enacted by Congress in 2016. Although regulatory processes have improved since the introduction of the Early Feasibility Studies Program, impediments at the hospital and clinical site level remain. In this paper, the authors review these issues and outline the structure and function of a clinical site consortium designed to address the problems and improve the U.S. clinical trial ecosystem.


Assuntos
Doenças Cardiovasculares/terapia , Aprovação de Equipamentos/legislação & jurisprudência , Política de Saúde/legislação & jurisprudência , Avaliação da Tecnologia Biomédica/legislação & jurisprudência , Doenças Cardiovasculares/diagnóstico , Doenças Cardiovasculares/fisiopatologia , Difusão de Inovações , Estudos de Viabilidade , Regulamentação Governamental , Humanos , Segurança do Paciente/legislação & jurisprudência , Formulação de Políticas , Fatores de Tempo , Estados Unidos , Fluxo de Trabalho
19.
J Am Coll Cardiol ; 71(4): 443-453, 2018 01 30.
Artigo em Inglês | MEDLINE | ID: mdl-29389362

RESUMO

The current heart failure clinical trial environment is strained by increasing complexity and cost, regulatory requirements, competing demands on stakeholders, implementation challenges, and decreasing patient and investigator participation. To begin the process of developing potentially effective strategies and tactics, stakeholders including patients; investigators; academic leaders; pharmaceutical and device industry representatives; society representatives; third-party payers; and government representatives from the U.S. Food and Drug Administration, National Institutes of Health, and Centers for Medicare and Medicaid Services convened in March of 2017. This paper summarizes the discussions, outlines current challenges and actionable opportunities, and makes targeted recommendations to achieve the goals of improving efficiency in clinical trials and speeding the development of effective heart failure therapies, including the formation of an organized Heart Failure Collaboratory.


Assuntos
Insuficiência Cardíaca/terapia , Colaboração Intersetorial , Parcerias Público-Privadas , Ensaios Clínicos como Assunto , Humanos , Estados Unidos
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa