RESUMO
OBJECTIVES: This study aimed to report a large, single-center experience of percutaneous arterial duct (AD) closure using Amplatzer Duct Occluder II Additional Sizes device (ADO II-AS)(St. Jude Medical Corp, St. Paul, MN, USA). BACKGROUND: Transcatheter closure of AD remains challenging in low body weight patients and those who have a persisting shunt following a previous attempt at interventional closure. Recent technical advances in device design may address these issues. METHODS: From May 2011 to April 2016, 109 patients underwent attempted percutaneous closure of AD with ADO II-AS at our Institution. Mean age and weight were 4.8 ± 8.1 years (range 0-48) and 21.4 ± 20.6 kg (range 3-93), respectively. Fifteen patients (13.8%) were ≤6 kg (age 3.5 ± 2.0 months; weight 4.7 ± 1.1 kg). Arterial duct morphology was type A in 62 (57%), type B in 1 (1%), type C in 32 (29%), type D in 7 (6%) and type E in 6 patients (6%), respectively. Arterial approach was used to negotiate and deploy the occluding device in 103 patients (94.5%). RESULTS: AD diameter was 2.2 ± 0.6 (range 1.5-4.5) resulting in QP/QS of 1.9 ± 0.7 (range 1-3.3). Mean pulmonary artery pressure and PA/aortic pressure ratio were 19.3 ± 5.0 mm Hg (range 12-38) and 0.34 ± 0.14 (range 0.14-0.95), respectively. Successful device deployment was achieved in 107 patients (98.2%). Neither procedural morbidity nor mortality was recorded. Immediate, 24h and mid-term (30 ± 17 months) complete occlusion was recorded in 71%, 98.1%, and 100% of patients, respectively. CONCLUSION: In our experience, trans-catheter closure of AD of different sizes and morphologies using ADO II-AS is highly feasible, safe and effective also in challenging anatomic/clinical settings. © 2016 Wiley Periodicals, Inc.
Assuntos
Cateterismo Cardíaco/instrumentação , Permeabilidade do Canal Arterial/terapia , Dispositivo para Oclusão Septal , Adolescente , Adulto , Aortografia , Cateterismo Cardíaco/efeitos adversos , Criança , Pré-Escolar , Permeabilidade do Canal Arterial/diagnóstico por imagem , Permeabilidade do Canal Arterial/fisiopatologia , Feminino , Humanos , Lactente , Recém-Nascido , Itália , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Fatores de Tempo , Resultado do Tratamento , Adulto JovemRESUMO
AIMS: Congenital heart diseases (CHDs) often show a complex 3D anatomy that must be well understood to assess the pathophysiological consequences and to guide therapy. Three-dimensional imaging technologies have the potential to enhance the physician's comprehension of such spatially complex anatomies. Unfortunately, due to the new introduction in clinical practice, there is no evidence on the current applications. We conducted a survey to examine how 3D technologies are currently used among CHD European centres. METHODS: Data were collected using an online self-administered survey via SurveyMonkey. The questionnaire was sent via e-mail and the responses were collected between January and June 2022. RESULTS: Ninety-eight centres correctly completed the survey. Of these, 22 regularly perform 3D rotational angiography, 43 have the availability to print in-silico models, and 22 have the possibility to visualize holographic imaging/virtual reality. The costs were mostly covered by the hospital or the department of financial resources. CONCLUSION: From our survey, it emerges that these technologies are quite spread across Europe, despite not being part of a routine practice. In addition, there are still not enough data supporting the improvement of clinical management for CHD patients. For this reason, further studies are needed to develop clinical recommendations for the use of 3D imaging technologies in medical practice.