1.
Ann Surg Oncol ; 30(13): 8735-8742, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37661223

RESUMO

OBJECTIVE: This study investigates the performance of the DiffMag handheld probe (nonlinear magnetometry), to be used for sentinel lymph node detection. Furthermore, the performance of DiffMag is compared with a gamma probe and a first-order magnetometer (Sentimag®, linear magnetometry). METHODS: The performance of all three probes was evaluated based on longitudinal distance, transverse distance, and resolving power for two tracer volumes. A phantom was developed to investigate the performance of the probes for a clinically relevant situation in the floor of the mouth (FOM). RESULTS: Considering the longitudinal distance, both DiffMag handheld and Sentimag® probe had comparable performance, while the gamma probe was able to detect at least a factor of 10 deeper. Transverse distances of 13, 11, and 51 mm were measured for the small tracer volume by the DiffMag handheld, Sentimag®, and the gamma probe, respectively. For the large tracer volume this was 21, 18, and 55 mm, respectively. The full width at half maximum, at 7 mm probe height from the phantom surface, was 14, 12, and 18 mm for the small tracer volume and 15, 18, and 25 mm for the large tracer volume with the DiffMag handheld, Sentimag®, and gamma probe, respectively. CONCLUSIONS: With a high resolving power but limited longitudinal distance, the DiffMag handheld probe seems suitable for detecting SLNs which are in close proximity to the primary tumor. In this study, comparable results were shown using linear magnetometry. The gamma probe reached 10 times deeper, but has a lower resolving power compared with the DiffMag handheld probe.


Assuntos
Nanopartículas de Magnetita , Linfonodo Sentinela , Humanos , Linfonodo Sentinela/patologia , Biópsia de Linfonodo Sentinela/métodos , Magnetometria , Fenômenos Magnéticos , Linfonodos/patologia
2.
Eur J Nucl Med Mol Imaging ; 50(12): 3572-3575, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37421427

RESUMO

INTRODUCTION: For the implementation of suitable radiation safety measures in [177Lu]Lu-PSMA-617 therapy, additional insight into excretion kinetics is important. This study evaluates this kinetics in prostate cancer patients via direct urine measurements. METHODS: Both the short-term (up to 24 h, n = 28 cycles) and long-term kinetics (up to 7 weeks, n = 35 samples) were evaluated by collection of urine samples. Samples were measured on a scintillation counter to determine excretion kinetics. RESULTS: The mean excretion half-time during the first 20 h was 4.9 h. Kinetics was significantly different for patients with kidney function below or above eGFR 65 ml/min. Calculated skin equivalent dose in case of urinary contamination was between 50 and 145 mSv when it was caused between 0 and 8 h p.i.. Measurable amounts of 177Lu were found in urine samples up to 18 days p.i.. CONCLUSION: Excretion kinetics of [177Lu]Lu-PSMA-617 is especially relevant during the first 24 h, when accurate radiation safety measures are important to prevent skin contamination. Measures for accurate waste management are relevant up to 18 days.


Assuntos
Neoplasias de Próstata Resistentes à Castração , Neoplasias da Próstata , Masculino , Humanos , Compostos Radiofarmacêuticos/uso terapêutico , Antígeno Prostático Específico , Neoplasias da Próstata/radioterapia , Neoplasias da Próstata/tratamento farmacológico , Dipeptídeos/uso terapêutico , Compostos Heterocíclicos com 1 Anel/uso terapêutico , Neoplasias de Próstata Resistentes à Castração/tratamento farmacológico , Lutécio/uso terapêutico
3.
Eur J Nucl Med Mol Imaging ; 49(2): 460-469, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34218300

RESUMO

INTRODUCTION: While [177Lu]Lu-PSMA radioligand therapy is currently only applied in end-stage metastatic castrate-resistant prostate cancer (mCRPC) patients, also low-volume hormone-sensitive metastatic prostate cancer (mHSPC) patients can benefit from it. However, there are toxicity concerns related to the sink effect in low-volume disease. This prospective study aims to determine the kinetics of [177Lu]Lu-PSMA in mHSPC patients, analyzing the doses to organs at risk (salivary glands, kidneys, liver, and bone marrow) and tumor lesions < 1 cm diameter. METHODS: Ten mHSPC patients underwent two cycles of [177Lu]Lu-PSMA therapy. Three-bed position SPECT/CT was performed at 5 time points after each therapy. Organ dosimetry and lesion dosimetry were performed using commercial software and a manual approach, respectively. Correlation between absorbed index lesion dose and treatment response (PSA drop of > 50% at the end of the study) was calculated and given as Spearman's r and p-values. RESULTS: Kinetics of [177Lu]Lu-PSMA in mHSPC patients are comparable to those in mCRPC patients. Lesion absorbed dose was high (3.25 ± 3.19 Gy/GBq) compared to organ absorbed dose (salivary glands: 0.39 ± 0.17 Gy/GBq, kidneys: 0.49 ± 0.11 Gy/GBq, liver: 0.09 ± 0.01 Gy/GBq, bone marrow: 0.017 ± 0.008 Gy/GBq). A statistically significant correlation was found between treatment response and absorbed index lesion dose (p = 0.047). CONCLUSIONS: We successfully performed small lesion dosimetry and showed that the tumor sink effect in mHSPC patients is of less concern than was expected. Tumor-to-organ ratio of absorbed dose was high and tumor uptake correlates with PSA response. Additional treatment cycles are legitimate in terms of organ toxicity and could lead to better tumor response.


Assuntos
Lutécio , Antígeno Prostático Específico , Neoplasias da Próstata , Compostos Radiofarmacêuticos , Hormônios/metabolismo , Humanos , Lutécio/efeitos adversos , Lutécio/farmacocinética , Lutécio/uso terapêutico , Masculino , Órgãos em Risco/diagnóstico por imagem , Órgãos em Risco/efeitos da radiação , Estudos Prospectivos , Antígeno Prostático Específico/efeitos adversos , Antígeno Prostático Específico/sangue , Antígeno Prostático Específico/farmacocinética , Antígeno Prostático Específico/uso terapêutico , Neoplasias da Próstata/sangue , Neoplasias da Próstata/metabolismo , Neoplasias da Próstata/radioterapia , Neoplasias da Próstata/secundário , Doses de Radiação , Compostos Radiofarmacêuticos/efeitos adversos , Compostos Radiofarmacêuticos/farmacocinética , Compostos Radiofarmacêuticos/uso terapêutico , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único , Resultado do Tratamento
4.
Eur J Nucl Med Mol Imaging ; 49(4): 1101-1112, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34623453

RESUMO

INTRODUCTION: Patient eligibility for [177Lu]Lu-PSMA therapy remains a challenge, with only 40-60% response rate when patient selection is done based on the lesion uptake (SUV) on [68Ga]Ga-PSMA-PET/CT. Prediction of absorbed dose based on this pre-treatment scan could improve patient selection and help to individualize treatment by maximizing the absorbed dose to target lesions while adhering to the threshold doses for the organs at risk (kidneys, salivary glands, and liver). METHODS: Ten patients with low-volume hormone-sensitive prostate cancer received a pre-therapeutic [68Ga]Ga-PSMA-11 PET/CT, followed by 3 GBq [177Lu]Lu-PSMA-617 therapy. Intra-therapeutically, SPECT/CT was acquired at 1, 24, 48, 72, and 168 h. Absorbed dose in organs and lesions (n = 22) was determined according to the MIRD scheme. Absorbed dose prediction based on [68Ga]Ga-PSMA-PET/CT was performed using tracer uptake at 1 h post-injection and the mean tissue effective half-life on SPECT. Predicted PET/actual SPECT absorbed dose ratios were determined for each target volume. RESULTS: PET/SPECT absorbed dose ratio was 1.01 ± 0.21, 1.10 ± 0.15, 1.20 ± 0.34, and 1.11 ± 0.29 for kidneys (using a 2.2 scaling factor), liver, submandibular, and parotid glands, respectively. While a large inter-patient variation in lesion kinetics was observed, PET/SPECT absorbed dose ratio was 1.3 ± 0.7 (range: 0.4-2.7, correlation coefficient r = 0.69, p < 0.01). CONCLUSION: A single time point [68Ga]Ga-PSMA-PET scan can be used to predict the absorbed dose of [177Lu]Lu-PSMA therapy to organs, and (to a limited extent) to lesions. This strategy facilitates in treatment management and could increase the personalization of [177Lu]Lu-PSMA therapy.


Assuntos
Radioisótopos de Gálio , Neoplasias de Próstata Resistentes à Castração , Dipeptídeos , Compostos Heterocíclicos com 1 Anel , Humanos , Lutécio , Masculino , Órgãos em Risco/patologia , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Tomografia por Emissão de Pósitrons , Antígeno Prostático Específico , Neoplasias de Próstata Resistentes à Castração/patologia , Compostos Radiofarmacêuticos/uso terapêutico
5.
Nucl Med Commun ; 44(4): 270-275, 2023 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-36597884

RESUMO

PURPOSE: For prostate-specific membrane antigen-directed radioligand therapy (PSMA-RLT), [ 177 Lu]Lu-PSMA-617 and [ 177 Lu]Lu-PSMA-I&T are the currently preferred compounds. Recent preclinical studies suggested ~30x higher kidney absorbed dose for [ 177 Lu]Lu-PSMA-I&T compared to [ 177 Lu]Lu-PSMA-617, which may lead to an increased risk of kidney toxicity. We performed two single-centre, prospective dosimetry studies with either [ 177 Lu]Lu-PSMA-617 or [ 177 Lu]Lu-PSMA-I&T, using an identical dosimetry protocol. We evaluated the absorbed doses of both 177 Lu-labelled radioligands in human kidneys. METHODS: 3D SPECT/computed tomography (CT) imaging of the kidneys was performed after PSMA-RLT in cancer patients with PSMA-positive disease and an adequate glomerular filtration rate (≥50 mL/min). Ten metastatic hormone-sensitive prostate cancer patients (mHSPC) were treated with [ 177 Lu]Lu-PSMA-617 and 10 advanced salivary gland cancer (SGC) patients were treated with [ 177 Lu]Lu-PSMA-I&T. SPECT/CT imaging was performed at five timepoints (1 h, 24 h, 48 h, 72 h, and 168 h post-injection). In mHSPC patients, SPECT/CT imaging was performed after cycles 1 and 2 (cumulative activity: 9 GBq) and in SGC patients only after cycle 1 (activity: 7.4 GBq). Kidney absorbed dose was calculated using organ-based dosimetry. RESULTS: The median kidney absorbed dose was 0.49 Gy/GBq (range: 0.34-0.66) and 0.73 Gy/GBq (range: 0.42-1.31) for [ 177 Lu]Lu-PSMA-617 and [ 177 Lu]Lu-PSMA-I&T, respectively (independent samples t test; P = 0.010). CONCLUSION: This study shows that the kidney absorbed dose for [ 177 Lu]Lu-PSMA-617 and [ 177 Lu]Lu-PSMA-I&T differs, with a ~1.5x higher median kidney absorbed dose for [ 177 Lu]Lu-PSMA-I&T. This difference in the clinical setting is considerably smaller than observed in preclinical studies and may not hamper treatments with [ 177 Lu]Lu-PSMA-I&T.


Assuntos
Rim , Neoplasias da Próstata , Masculino , Humanos , Estudos Prospectivos , Doses de Radiação
6.
EJNMMI Res ; 13(1): 6, 2023 Jan 24.
Artigo em Inglês | MEDLINE | ID: mdl-36692682

RESUMO

BACKGROUND: Dosimetry in [177Lu]Lu-PSMA therapy is a valuable tool to assess treatment efficacy and toxicity. This study aims to develop a clinically implementable protocol to determine the absorbed dose in organs and tumor lesions after [177Lu]Lu-PSMA-617 therapy, by reducing the imaging time points and utilizing population-based kinetics with a single scan, with evaluation of its influence on the uncertainty in absorbed dose. METHODS: Ten patients with metastatic hormone-sensitive prostate cancer received two cycles of [177Lu]Lu-PSMA-617. Post-treatment imaging was performed at 1 h, 24 h, 48 h, 72 h and 168 h, consisting of three-bed positions SPECT/CT and a whole-body planar scan. Five-time point SPECT dosimetry was performed for lesions and organs with physiological uptake (kidneys, liver and salivary glands) and used as the reference standard. Absorbed dose values for various simplified protocols were compared to the reference standard. RESULTS: Accurate lesion dosimetry is possible using one-time point SPECT imaging at 168 h, with an increase in uncertainty (20% vs. 14% for the reference standard). By including a second time point, uncertainty was comparable to the reference standard (13%). Organ dosimetry can be performed using a single SPECT at 24 h or 48 h. Dosimetry based on planar scans did not provide accurate dose estimations. CONCLUSION: Accurate lesion dosimetry in [177Lu]Lu-PSMA therapy can be performed using a one- or two-time point protocol, making dosimetry assessments more suitable for routine clinical implementation, although dosimetry based om multiple time points is more accurate. Clinical trial registration This study was approved by the Medical Review Ethics Committee Region Arnhem-Nijmegen on January 23, 2018 and was registered on clinicaltrials.gov (NCT03828838).

SELEÇÃO DE REFERÊNCIAS