Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Radiography (Lond) ; 28(2): 276-282, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-34702663

RESUMO

INTRODUCTION: The topic of healthcare human resource planning for diagnostic radiographers has received limited research attention to date. This research is concerned with developing a framework that can be used to determine diagnostic radiographer staffing requirements at a unit- or department level (i.e. at the micro-level). METHODS: An inductive approach is applied to formulate requirement specifications that inform the development of the framework. A number of verification and validation activities are performed, including theoretical verification and a case study application. RESULTS: The diagnostic radiographer staffing framework consists of seven steps that comprise a workload-based approach to determining the number of full time equivalent diagnostic radiographers that are required for each modality, or group of modalities. Both clinical and non-clinical activities are considered, and guidance is provided on calculating staffing requirements to cover leave allowances. A number of potential approaches to determining activity times are also discussed. CONCLUSION: The framework represents a holistic approach to determining the required number of diagnostic radiographers at a practice-level, that is designed to remain relevant as technological advances are made in the field of diagnostic radiography. IMPLICATIONS FOR PRACTICE: By providing a practical guideline, with accompanying examples, the framework is expected to hold value for individuals involved in the management of diagnostic radiography practices. The framework proposes an approach to a topic that affects every radiography practice in operation yet has received limited attention in literature to date.


Assuntos
Pessoal Técnico de Saúde , Carga de Trabalho , Humanos , Radiografia , Recursos Humanos
2.
Ann Oncol ; 22(9): 2086-2093, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21343383

RESUMO

BACKGROUND: A pilot study (NCT00316563) to determine if delta-9-tetrahydrocannabinol (THC) can improve taste and smell (chemosensory) perception as well as appetite, caloric intake, and quality of life (QOL) for cancer patients with chemosensory alterations. PATIENTS AND METHODS: Adult advanced cancer patients, with poor appetite and chemosensory alterations, were recruited from two sites and randomized in a double-blinded manner to receive either THC (2.5 mg, Marinol(®); Solvay Pharma Inc., n = 24) or placebo oral capsules (n = 22) twice daily for 18 days. Twenty-one patients completed the trial. At baseline and posttreatment, patients completed a panel of patient-reported outcomes: Taste and Smell Survey, 3-day food record, appetite and macronutrient preference assessments, QOL questionnaire, and an interview. RESULTS: THC and placebo groups were comparable at baseline. Compared with placebo, THC-treated patients reported improved (P = 0.026) and enhanced (P < 0.001) chemosensory perception and food 'tasted better' (P = 0.04). Premeal appetite (P = 0.05) and proportion of calories consumed as protein increased compared with placebo (P = 0.008). THC-treated patients reported increased quality of sleep (P = 0.025) and relaxation (P = 0.045). QOL scores and total caloric intake were improved in both THC and placebo groups. CONCLUSIONS: THC may be useful in the palliation of chemosensory alterations and to improve food enjoyment for cancer patients.


Assuntos
Dronabinol/uso terapêutico , Neoplasias/tratamento farmacológico , Neoplasias/fisiopatologia , Percepção Olfatória/efeitos dos fármacos , Cuidados Paliativos/métodos , Percepção Gustatória/efeitos dos fármacos , Idoso , Método Duplo-Cego , Dronabinol/efeitos adversos , Feminino , Humanos , Masculino , Projetos Piloto , Placebos , Qualidade de Vida
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa