Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
J Ultrasound Med ; 41(7): 1781-1789, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34724241

RESUMO

OBJECTIVES: Subharmonic aided pressure estimation (SHAPE) has been shown effective for noninvasively measuring hydrostatic fluid pressures in a variety of clinical applications. The objective of this study was to explore potential improvements in SHAPE sensitivity using monodisperse microbubbles. METHODS: Populations of monodisperse microbubbles were created using a commercially available microfluidics device (Solstice Pharmaceuticals). Size distributions were assessed using a Coulter Counter and stability of the distribution following fabrication was evaluated over 24 hours. Attenuation of the microbubble populations from 1 to 10 MHz was then quantified using single element transducers to identify each formulation's resonance frequency. Frequency spectra over increasing driving amplitudes were investigated to determine the nonlinear phases of subharmonic signal generation. SHAPE sensitivity was evaluated in a hydrostatic pressure-controlled water bath using a Logiq E10 scanner (GE Healthcare). RESULTS: Monodisperse lipid microbubble suspensions ranging from 2.4 to 5.3 µm in diameter were successfully created and they showed no discernable change in size distribution over 24 hours following activation. Calculated resonance frequencies ranged from 2.1 to 6.3 MHz and showed excellent correlation with microbubble diameter (R2 > 0.99). When investigating microbubble frequency response, subharmonic signal occurrence was shown to begin at 150 kPa peak negative pressure, grow up to 225 kPa, and saturate at approximately 250 kPa. Using the Logiq E10, monodisperse bubbles demonstrated a SHAPE sensitivity of -0.17 dB/mmHg, which was nearly twice the sensitivity of the commercial polydisperse microbubble currently being used in clinical trials. CONCLUSIONS: Monodisperse microbubbles have the potential to greatly improve the sensitivity of SHAPE for the noninvasive measurement of hydrostatic pressures.


Assuntos
Meios de Contraste , Microbolhas , Determinação da Pressão Arterial , Humanos , Transdutores , Ultrassonografia
2.
Macromol Biosci ; 20(6): e2000084, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32346989

RESUMO

In this study, the neoplastic drug frequently used in the treatment of lung cancer, carboplatin is loaded to microbubbles via a microfluidic platform. In order to increase the drug loading capacity of microbubbles, carboplatin is encapsulated into alginate polymer layer. The phospholipid microbubbles (MBs) are synthesized by MicroSphere Creator, which is connected with T-junction and micromixer for the treatment with CaCl2 solution to provide gelation of the alginate coated phospholipid microbubbles (AMBs). The carboplatin loaded alginate coated phospholipid microbubbles (CAMBs) result in 12.2 ± 0.21 µm mean size, obtained by mixing with 0.05% CaCl2 using T-junction. The cytotoxic activities of the synthesized MBs, AMBs, and CAMBs are also investigated with the 3-(4,5-Dimethyl-2-thiazolyl)-2,5-diphenyl-2H-tetrazolium bromide) (MTT) and live/dead fluorescent dying assays in the A549 and BEAS-2B cell lines. The one-step microfluidic coating of lipid microbubbles with natural alginate polymer appears to be a promising strategy for enhanced drug reservoir properties.


Assuntos
Adenocarcinoma de Pulmão/tratamento farmacológico , Alginatos , Antineoplásicos , Portadores de Fármacos , Dispositivos Lab-On-A-Chip , Neoplasias Pulmonares/tratamento farmacológico , Microbolhas , Fosfolipídeos , Células A549 , Adenocarcinoma de Pulmão/metabolismo , Adenocarcinoma de Pulmão/patologia , Alginatos/química , Alginatos/farmacocinética , Alginatos/farmacologia , Antineoplásicos/química , Antineoplásicos/farmacocinética , Antineoplásicos/farmacologia , Portadores de Fármacos/química , Portadores de Fármacos/farmacocinética , Portadores de Fármacos/farmacologia , Humanos , Neoplasias Pulmonares/metabolismo , Neoplasias Pulmonares/patologia , Fosfolipídeos/química , Fosfolipídeos/farmacocinética , Fosfolipídeos/farmacologia
3.
Sci Rep ; 7(1): 12746, 2017 10 06.
Artigo em Inglês | MEDLINE | ID: mdl-28986558

RESUMO

B-lines are ultrasound-imaging artifacts, which correlate with several lung-pathologies. However, their understanding and characterization is still largely incomplete. To further study B-lines, lung-phantoms were developed by trapping a layer of microbubbles in tissue-mimicking gel. To simulate the alveolar size reduction typical of various pathologies, 170 and 80 µm bubbles were used for phantom-type 1 and 2, respectively. A normal alveolar diameter is approximately 280 µm. A LA332 linear-array connected to the ULA-OP platform was used for imaging. Standard ultrasound (US) imaging at 4.5 MHz was performed. Subsequently, a multi-frequency approach was used where images were sequentially generated using orthogonal sub-bands centered at different frequencies (3, 4, 5, and 6 MHz). Results show that B-lines appear predominantly with phantom-type 2. Moreover, the multi-frequency approach revealed that the B-lines originate from a specific portion of the US spectrum. These results can give rise to significant clinical applications since, if further confirmed by extensive in-vivo studies, the native frequency of B-lines could provide a quantitative-measure of the state of the lung.


Assuntos
Pulmão/diagnóstico por imagem , Análise Espectral , Ultrassonografia , Microbolhas , Imagens de Fantasmas , Gravação em Vídeo
4.
Lab Chip ; 13(23): 4503-6, 2013 Dec 07.
Artigo em Inglês | MEDLINE | ID: mdl-24141306

RESUMO

The so-called "Kelvin water dropper" is a simple experiment demonstrating the spontaneous appearance of induced free charge in droplets emitted through a tube. As Lord Kelvin explained, water droplets spontaneously acquire a net charge during detachment from a faucet due to the presence of electrical fields in their surroundings created by any metallic object. In his experiment, two streams of droplets are allowed to drip from separate nozzles into separate buckets, which are, at the same time, interconnected through the dripping needles. In this paper, we build a microfluidic water dropper and demonstrate that the droplets get charged and break up due to electrohydrodynamic instabilities. A comparison with recent simulations shows the dependence of the acquired charge in the droplets on different parameters of the system. The phenomenon opens a door to cheap and accessible transformation of pneumatic pressure into electrical energy and to an enhanced control in microfluidic and biophysical manipulation of capsules, cells and droplets via self-induced charging of the elements.

5.
Lab Chip ; 11(12): 2023-9, 2011 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-21431188

RESUMO

A new regime of operation of PDMS-based flow-focusing microfluidic devices is presented. We show that monodisperse microbubbles with diameters below one-tenth of the channel width (here w = 50 µm) can be produced in low viscosity liquids thanks to a strong pressure gradient in the entrance region of the channel. In this new regime bubbles are generated at the tip of a long and stable gas ligament whose diameter, which can be varied by tuning appropriately the gas and liquid flow rates, is substantially smaller than the channel width. Through this procedure the volume of the bubbles formed at the tip of the gas ligament can be varied by more than two orders of magnitude. The experimental results for the bubble diameter d(b) as function of the control parameters are accounted for by a scaling theory, which predicts d(b)/w ∝ (µ(g)/µ(l))(1/12)(Q(g)/Q(l))(5/12), where µ(g) and µ(l) indicate, respectively, the gas and liquid viscosities and Q(g) and Q(l) are the gas and liquid flow rates. As a particularly important application of our results we produce monodisperse bubbles with the appropriate diameter for therapeutic applications (d(b) ≃ 5 µm) and a production rate exceeding 10(5) Hz.


Assuntos
Microbolhas , Técnicas Analíticas Microfluídicas/instrumentação , Meios de Contraste , Gases , Técnicas Analíticas Microfluídicas/métodos , Tamanho da Partícula , Viscosidade
6.
Phys Rev Lett ; 100(3): 034504, 2008 Jan 25.
Artigo em Inglês | MEDLINE | ID: mdl-18232987

RESUMO

The formation of bubbles by flow focusing of a gas and a liquid in a rectangular channel is shown to depend strongly on the channel aspect ratio. Bubble breakup consists in a slow linear 2D collapse of the gas thread, ending in a fast 3D pinch-off. The 2D collapse is predicted to be stable against perturbations of the gas-liquid interface, whereas the 3D pinch-off is unstable, causing bubble polydispersity. During 3D pinch-off, a scaling w_(m) approximately tau(1/3) between the neck width w_(m) and the time tau before breakup indicates that breakup is driven by the inertia of both gas and liquid, not by capillarity.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa