Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 65
Filtrar
1.
Alzheimers Dement ; 2024 Jun 14.
Artigo em Inglês | MEDLINE | ID: mdl-38877668

RESUMO

INTRODUCTION: The entorhinal cortex (EC) and perirhinal cortex (PC) are vulnerable to Alzheimer's disease. A triggering factor may be the interaction of vascular dysfunction and tau pathology. METHODS: We imaged post mortem human tissue at 100 µm3 with 7 T magnetic resonance imaging and manually labeled individual blood vessels (mean = 270 slices/case). Vessel density was quantified and compared per EC subfield, between EC and PC, and in relation to tau and TAR DNA-binding protein 43 (TDP-43) semiquantitative scores. RESULTS: PC was more vascularized than EC and vessel densities were higher in posterior EC subfields. Tau and TDP-43 strongly correlated with vasculature density and subregions with severe tau at the preclinical stage had significantly greater vessel density than those with low tau burden. DISCUSSION: These data impact cerebrovascular maps, quantification of subfield vasculature, and correlation of vasculature and pathology at early stages. The ordered association of vessel density, and tau or TDP-43 pathology, may be exploited in a predictive context. HIGHLIGHTS: Vessel density correlates with phosphorylated tau (p-tau) burden in entorhinal and perirhinal cortices. Perirhinal area 35 and posterior entorhinal cortex showed greatest p-tau burden but also the highest vessel density in the preclinical phase of Alzheimer's disease. We combined an ex vivo magnetic resonance imaging model and histopathology to demonstrate the 3D reconstruction of intracortical vessels and its spatial relationship to the pathology.

2.
Hum Brain Mapp ; 43(13): 4128-4144, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35575438

RESUMO

Children with perinatally acquired HIV (CPHIV) have poor cognitive outcomes despite early combination antiretroviral therapy (cART). While CPHIV-related brain alterations can be investigated separately using proton magnetic resonance spectroscopy (1 H-MRS), structural magnetic resonance imaging (sMRI), diffusion tensor imaging (DTI), and functional MRI (fMRI), a set of multimodal MRI measures characteristic of children on cART has not been previously identified. We used the embedded feature selection of a logistic elastic-net (EN) regularization to select neuroimaging measures that distinguish CPHIV from controls and measured their classification performance via the area under the receiver operating characteristic curve (AUC) using repeated cross validation. We also wished to establish whether combining MRI modalities improved the models. In single modality analysis, sMRI volumes performed best followed by DTI, whereas individual EN models on spectroscopic, gyrification, and cortical thickness measures showed no class discrimination capability. Adding DTI and 1 H-MRS in basal measures to sMRI volumes produced the highest classification performance validation accuracy = 85 % AUC = 0.80 . The best multimodal MRI set consisted of 22 DTI and sMRI volume features, which included reduced volumes of the bilateral globus pallidus and amygdala, as well as increased mean diffusivity (MD) and radial diffusivity (RD) in the right corticospinal tract in cART-treated CPHIV. Consistent with previous studies of CPHIV, select subcortical volumes obtained from sMRI provide reasonable discrimination between CPHIV and controls. This may give insight into neuroimaging measures that are relevant in understanding the effects of HIV on the brain, thereby providing a starting point for evaluating their link with cognitive performance in CPHIV.


Assuntos
Imagem de Tensor de Difusão , Infecções por HIV , Encéfalo , Criança , Imagem de Tensor de Difusão/métodos , Infecções por HIV/diagnóstico por imagem , Infecções por HIV/tratamento farmacológico , Infecções por HIV/patologia , Humanos , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética , Neuroimagem
3.
Magn Reson Med ; 88(1): 211-223, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35344618

RESUMO

PURPOSE: Although 3D EPI is more susceptible to motion artifacts than 2D EPI, it presents some benefits for functional MRI, including the absence of spin-history artifacts, greater potential for parallel imaging acceleration, and better functional sensitivity in high-resolution imaging. Here we present a self-navigated 3D-EPI sequence suitable for prospective motion-corrected functional MRI without additional hardware or pulses. METHODS: For each volume acquisition, the first 24 of the 52 partitions being acquired are accumulated to a new feedback block that was added to the image reconstruction pipeline. After zero-filling the remaining partitions, the feedback block constructs a volumetric self-navigator (vSNav), co-registers it to the reference vSNav acquired during the first volume acquisition, and sends motion estimates to the sequence. The sequence then updates its FOV and acquires subsequent partitions with the adjusted FOV, until the next update is received. The sequence was validated without and with intentional motion in phantom and in vivo on a 3T Skyra. RESULTS: For phantom scans, the FOV was updated 0.704 s after acquisition of the vSNav partitions, and for in vivo scans after 0.768 s. Both phantom and in vivo data demonstrated stable motion estimates in the absence of motion. For in vivo acquisitions, prospective head-pose estimates using the vSNav's and retrospective estimates with FLIRT (FMRIB's Linear Image Registration Tool) agreed to within 0.23 mm (< 10% of the slice thickness) and 0.14° in all directions. CONCLUSION: Depending when motion occurs during a volume acquisition, the proposed method fully corrects the FOV and recovers image quality within one volume acquisition.


Assuntos
Artefatos , Encéfalo , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Movimento (Física) , Estudos Prospectivos , Estudos Retrospectivos
4.
Alcohol Clin Exp Res ; 45(9): 1762-1774, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34342017

RESUMO

BACKGROUND: Prenatal alcohol exposure (PAE) is associated with smaller regional and global brain volumes. In rats, gestational choline supplementation mitigates adverse developmental effects of ethanol exposure. Our recent randomized, double-blind, placebo-controlled maternal choline supplementation trial showed improved somatic and functional outcomes in infants at 6.5 and 12 months postpartum. Here, we examined whether maternal choline supplementation protected the newborn brain from PAE-related volume reductions and, if so, whether these volume changes were associated with improved infant recognition memory. METHODS: Fifty-two infants born to heavy-drinking women who had participated in a choline supplementation trial during pregnancy underwent structural magnetic resonance imaging with a multi-echo FLASH protocol on a 3T Siemens Allegra MRI (median age = 2.8 weeks postpartum). Subcortical regions were manually segmented. Recognition memory was assessed at 12 months on the Fagan Test of Infant Intelligence (FTII). We examined the effects of choline on regional brain volumes, whether choline-related volume increases were associated with higher FTII scores, and the degree to which the regional volume increases mediated the effects of choline on the FTII. RESULTS: Usable MRI data were acquired in 50 infants (choline: n = 27; placebo: n = 23). Normalized volumes were larger in six of 12 regions in the choline than placebo arm (t ≥ 2.05, p ≤ 0.05) and were correlated with the degree of maternal choline adherence (ß ≥ 0.28, p ≤ 0.04). Larger right putamen and corpus callosum were related to higher FTII scores (r = 0.36, p = 0.02) with a trend toward partial mediation of the choline effect on recognition memory. CONCLUSIONS: High-dose choline supplementation during pregnancy mitigated PAE-related regional volume reductions, with larger volumes associated with improved 12-month recognition memory. These results provide the first evidence that choline may be neuroprotective against PAE-related brain structural deficits in humans.


Assuntos
Encéfalo/efeitos dos fármacos , Colina/uso terapêutico , Suplementos Nutricionais , Etanol/efeitos adversos , Fármacos Neuroprotetores/uso terapêutico , Adulto , Encéfalo/diagnóstico por imagem , Método Duplo-Cego , Feminino , Transtornos do Espectro Alcoólico Fetal , Humanos , Lactente , Recém-Nascido , Testes de Inteligência , Imageamento por Ressonância Magnética , Adesão à Medicação , Memória/efeitos dos fármacos , Gravidez , Estudos Prospectivos , Adulto Jovem
5.
Magn Reson Med ; 81(4): 2600-2613, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30506877

RESUMO

PURPOSE: CEST MRI allows for indirect detection of molecules with exchangeable protons, measured as a reduction in water signal because of continuous transfer of saturated protons. CEST requires saturation pulses on the order of a second, as well as repeated acquisitions at different offset frequencies. The resulting extended scan time makes CEST susceptible to subject motion, which introduces field inhomogeneity, shifting offset frequencies and causing distortions in CEST spectra that resemble true CEST effects. This is a particular problem for molecules that resonate close to water, such as hydroxyl group in glycogen. To address this, a technique for real-time measurement and correction of motion and field inhomogeneity is proposed. METHODS: A CEST sequence was modified to include double volumetric navigators (DvNavs) for real-time simultaneous motion and shim correction. Phantom tests were conducted to investigate the effects of motion and shim changes on CEST quantification and to validate the accuracy of DvNav motion and shim estimates. To evaluate DvNav shim and motion correction in vivo, acquisitions including 5 experimental conditions were performed in the calf muscle of 2 volunteers. RESULTS: Phantom data show that DvNav-CEST accurately estimates frequency and linear gradient changes because of motion and corrects resulting image distortions. In addition, DvNav-CEST improves CEST quantification in vivo in the presence of motion. CONCLUSION: The proposed technique allows for real-time simultaneous motion and shim correction with no additional scanning time, enabling accurate CEST quantification even in the presence of motion and field inhomogeneity.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética , Movimento (Física) , Músculo Esquelético/patologia , Adulto , Algoritmos , Artefatos , Voluntários Saudáveis , Humanos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional , Modelos Lineares , Masculino , Imagens de Fantasmas , Reprodutibilidade dos Testes
6.
Alcohol Clin Exp Res ; 41(5): 965-975, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28247416

RESUMO

BACKGROUND: Magnetic resonance imaging (MRI) studies have consistently demonstrated disproportionately smaller corpus callosa in individuals with a history of prenatal alcohol exposure (PAE) but have not previously examined the feasibility of detecting this effect in infants. Tissue segmentation of the newborn brain is challenging because analysis techniques developed for the adult brain are not directly transferable, and segmentation for cerebral morphometry is difficult in neonates, due to the latter's incomplete myelination. This study is the first to use volumetric structural MRI to investigate PAE effects in newborns using manual tracing and to examine the cross-sectional area of the corpus callosum (CC). METHODS: Forty-three nonsedated infants born to 32 Cape Coloured heavy drinkers and 11 controls recruited prospectively during pregnancy were scanned using a custom-designed birdcage coil for infants, which increases signal-to-noise ratio almost 2-fold compared to the standard head coil. Alcohol use was ascertained prospectively during pregnancy, and fetal alcohol spectrum disorders diagnosis was conducted by expert dysmorphologists. Data were acquired using a multi-echo FLASH protocol adapted for newborns, and a knowledge-based procedure was used to hand-segment the neonatal brains. RESULTS: CC was disproportionately smaller in alcohol-exposed neonates than controls after controlling for intracranial volume. By contrast, CC area was unrelated to infant sex, gestational age, age at scan, or maternal smoking, marijuana, or methamphetamine use during pregnancy. CONCLUSIONS: Given that midline craniofacial anomalies have been recognized as a hallmark of fetal alcohol syndrome in humans and animal models since this syndrome was first identified, the CC deficit identified here in newborns may support early identification of a range of midline structural impairments. Smaller CC during the newborn period may provide an early indicator of fetal alcohol-related cognitive deficits that have been linked to this critically important brain structure in childhood and adolescence.


Assuntos
Consumo de Bebidas Alcoólicas/efeitos adversos , Corpo Caloso/diagnóstico por imagem , Imageamento por Ressonância Magnética , Efeitos Tardios da Exposição Pré-Natal/diagnóstico por imagem , Adulto , Consumo de Bebidas Alcoólicas/epidemiologia , Feminino , Humanos , Recém-Nascido , Estudos Longitudinais , Masculino , Gravidez , Efeitos Tardios da Exposição Pré-Natal/epidemiologia , África do Sul/epidemiologia , Adulto Jovem
7.
Neuroimage ; 126: 60-71, 2016 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-26584865

RESUMO

Diffusion tensor imaging (DTI) requires a set of diffusion weighted measurements in order to acquire enough information to characterize local structure. The MRI scanner automatically performs a shimming process by acquiring a field map before the start of a DTI scan. Changes in B0, which can occur throughout the DTI acquisition due to several factors (including heating of the iron shim coils or subject motion), cause significant signal distortions that result in warped diffusion tensor (DT) parameter estimates. In this work we introduce a novel technique to simultaneously measure, report and correct in real time subject motion and changes in B0 field homogeneity, both in and through the imaging plane. This is achieved using double volumetric navigators (DvNav), i.e. a pair of 3D EPI acquisitions, interleaved with the DTI pulse sequence. Changes in the B0 field are evaluated in terms of zero-order (frequency) and first-order (linear gradients) shim. The ability of the DvNav to accurately estimate the shim parameters was first validated in a water phantom. Two healthy subjects were scanned both in the presence and absence of motion using standard, motion corrected (single navigator, vNav), and DvNav DTI sequences. The difference in performance between the proposed 3D EPI field maps and the standard 3D gradient echo field maps of the MRI scanner was also evaluated in a phantom and two healthy subjects. The DvNav sequence was shown to accurately measure and correct changes in B0 following manual adjustments of the scanner's central frequency and the linear shim gradients. Compared to other methods, the DvNav produced DTI results that showed greater spatial overlap with anatomical references, particularly in scans with subject motion. This is largely due to the ability of the DvNav system to correct shim changes and subject motion between each volume acquisition, thus reducing shear distortion.


Assuntos
Encéfalo/anatomia & histologia , Imagem de Tensor de Difusão/métodos , Imagem Ecoplanar/métodos , Adulto , Imagem de Tensor de Difusão/normas , Imagem Ecoplanar/normas , Humanos , Masculino , Movimento
8.
Neuroimage ; 127: 11-22, 2016 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-26654788

RESUMO

Recent work has demonstrated that subject motion produces systematic biases in the metrics computed by widely used morphometry software packages, even when the motion is too small to produce noticeable image artifacts. In the common situation where the control population exhibits different behaviors in the scanner when compared to the experimental population, these systematic measurement biases may produce significant confounds for between-group analyses, leading to erroneous conclusions about group differences. While previous work has shown that prospective motion correction can improve perceived image quality, here we demonstrate that, in healthy subjects performing a variety of directed motions, the use of the volumetric navigator (vNav) prospective motion correction system significantly reduces the motion-induced bias and variance in morphometry.


Assuntos
Artefatos , Encéfalo , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética , Neuroimagem/métodos , Adulto , Algoritmos , Feminino , Movimentos da Cabeça , Humanos , Masculino , Movimento (Física) , Adulto Jovem
9.
Magn Reson Med ; 76(5): 1420-1430, 2016 11.
Artigo em Inglês | MEDLINE | ID: mdl-26567122

RESUMO

PURPOSE: The aim of this study was to improve robustness to motion in a vessel-encoded angiography sequence used for patient scans. The sequence is particularly sensitive to motion between imaging segments, which causes ghosting and blurring that propagates to the final angiogram. METHODS: Volumetric echo planar imaging (EPI) navigators acquired in 275 ms were inserted after the imaging readout in a vessel-encoded pseudo-continuous arterial spin labeling (VEPCASL) sequence. The effects of movement between segments on the images were tested with phantom experiments. Deliberate motion experiments with healthy volunteers were performed to compare prospective motion correction (PMC) with reacquisition versus no correction. RESULTS: In scans without motion, the addition of the EPI navigator to the sequence did not affect the quality of the angiograms in comparison with the original sequence. PMC and reacquisition improved the visibility of vessels in the angiograms compared with the scans without correction. The reacquisition strategy was shown to be important for complete correction of imaging artifacts. CONCLUSION: We have demonstrated an effective method to correct motion in vessel-encoded angiography. For reacquisition of 15 segments, the technique requires approximately 30 s of additional scanning (∼25%). Magn Reson Med 76:1420-1430, 2016. © 2015 International Society for Magnetic Resonance in Medicine.


Assuntos
Artefatos , Técnicas de Imagem de Sincronização Cardíaca/métodos , Artérias Carótidas/diagnóstico por imagem , Angiografia Cerebral/métodos , Aumento da Imagem/métodos , Imageamento Tridimensional/métodos , Angiografia por Ressonância Magnética/métodos , Algoritmos , Imagem Ecoplanar/métodos , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Movimento (Física) , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Marcadores de Spin , Técnica de Subtração
10.
NMR Biomed ; 29(3): 248-55, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26663075

RESUMO

Mescher-Garwood (MEGA) editing with spin echo full intensity acquired localization (MEGA-SPECIAL, MSpc) is a technique to acquire γ-aminobutyric acid (GABA) without macromolecule (MM) contamination at a TE of 68 ms. However, due to the requirement of multiple shot-localization, it is often susceptible to subject motion and B0 inhomogeneity. A method is presented for real-time shim and motion correction (ShMoCo) using volumetric navigators to correct for motion and motion-related B0 inhomogeneity during MSpc acquisition. A phantom experiment demonstrates that ShMoCo restores the GABA peak and improves spectral quality in the presence of motion and zero- and first-order shim changes. The ShMoCo scans were validated in three subjects who performed up-down and left-right head rotations. Qualitative assessment of these scans indicates effective reduction of subtraction artefacts and well edited GABA peaks, while quantitative analysis indicates superior fitting and spectral quality relative to scans with no correction. Copyright © 2015 John Wiley & Sons, Ltd.


Assuntos
Espectroscopia de Ressonância Magnética/métodos , Marcadores de Spin , Ácido gama-Aminobutírico/metabolismo , Humanos , Imagens de Fantasmas
11.
MAGMA ; 29(6): 863-874, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27393351

RESUMO

OBJECTIVE: Measuring the pure form of GABA has become increasingly important because of its association with behaviour and certain pathologies. The aim of this study was to assess the reproducibility of GABA measurements using a shim and motion navigated MEGA-SPECIAL sequence with LCModel, jMRUI and GANNET software. MATERIALS AND METHODS: Motion and shim navigated MEGA-SPECIAL scans were acquired in 20 healthy subjects. Two acquisitions were performed for each of two regions: the anterior cingulate (ACC) and medial-parietal (PAR) cortices. Absolute GABA concentration ([Formula: see text]) and GABA-to-Creatine ratio (GABA/Cr) were quantified using the three software packages. RESULTS: Using the within-subject coefficient of variation (CVws) as an index, reproducibility for both GABAH20 and GABA/Cr ranged from 13 to 22 % in the ACC and 13 to 18 % in PAR using the three software packages. CONCLUSION: Based on CVws, GABA concentrations in both the ACC and PAR are reproducible using a shim and motion navigated MEGA-SPECIAL sequence with any of the three software packages, thus demonstrating the ability to quantify the pure form of GABA using these software in studies relating GABA to pathology and healthy behaviour.


Assuntos
Giro do Cíngulo/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Substâncias Macromoleculares/química , Ácido gama-Aminobutírico/química , Adulto , Algoritmos , Encéfalo/diagnóstico por imagem , Mapeamento Encefálico , Feminino , Voluntários Saudáveis , Humanos , Espectroscopia de Ressonância Magnética , Masculino , Movimento (Física) , Reprodutibilidade dos Testes , Processamento de Sinais Assistido por Computador , Software , Adulto Jovem
12.
Neuroimage ; 107: 107-115, 2015 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-25498430

RESUMO

Imaging biomarkers derived from magnetic resonance imaging (MRI) data are used to quantify normal development, disease, and the effects of disease-modifying therapies. However, motion during image acquisition introduces image artifacts that, in turn, affect derived markers. A systematic effect can be problematic since factors of interest like age, disease, and treatment are often correlated with both a structural change and the amount of head motion in the scanner, confounding the ability to distinguish biology from artifact. Here we evaluate the effect of head motion during image acquisition on morphometric estimates of structures in the human brain using several popular image analysis software packages (FreeSurfer 5.3, VBM8 SPM, and FSL Siena 5.0.7). Within-session repeated T1-weighted MRIs were collected on 12 healthy volunteers while performing different motion tasks, including two still scans. We show that volume and thickness estimates of the cortical gray matter are biased by head motion with an average apparent volume loss of roughly 0.7%/mm/min of subject motion. Effects vary across regions and remain significant after excluding scans that fail a rigorous quality check. In view of these results, the interpretation of reported morphometric effects of movement disorders or other conditions with increased motion tendency may need to be revisited: effects may be overestimated when not controlling for head motion. Furthermore, drug studies with hypnotic, sedative, tranquilizing, or neuromuscular-blocking substances may contain spurious "effects" of reduced atrophy or brain growth simply because they affect motion distinct from true effects of the disease or therapeutic process.


Assuntos
Substância Cinzenta/anatomia & histologia , Movimentos da Cabeça/fisiologia , Imageamento por Ressonância Magnética/métodos , Adulto , Algoritmos , Artefatos , Biomarcadores , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Processamento de Imagem Assistida por Computador , Modelos Lineares , Controle de Qualidade
13.
J Magn Reson Imaging ; 41(5): 1353-64, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-24935904

RESUMO

PURPOSE: To evaluate the patterns of head motion in scans of young children and to examine the influence of corrective techniques, both qualitatively and quantitatively. We investigate changes that both retrospective (with and without diffusion table reorientation) and prospective (implemented with a short navigator sequence) motion correction induce in the resulting diffusion tensor measures. MATERIALS AND METHODS: Eighteen pediatric subjects (aged 5-6 years) were scanned using 1) a twice-refocused, 2D diffusion pulse sequence, 2) a prospectively motion-corrected, navigated diffusion sequence with reacquisition of a maximum of five corrupted diffusion volumes, and 3) a T1 -weighted structural image. Mean fractional anisotropy (FA) values in white and gray matter regions, as well as tractography in the brainstem and projection fibers, were evaluated to assess differences arising from retrospective (via FLIRT in FSL) and prospective motion correction. In addition to human scans, a stationary phantom was also used for further evaluation. RESULTS: In several white and gray matter regions retrospective correction led to significantly (P < 0.05) reduced FA means and altered distributions compared to the navigated sequence. Spurious tractographic changes in the retrospectively corrected data were also observed in subject data, as well as in phantom and simulated data. CONCLUSION: Due to the heterogeneity of brain structures and the comparatively low resolution (∼2 mm) of diffusion data using 2D single shot sequencing, retrospective motion correction is susceptible to distortion from partial voluming. These changes often negatively bias diffusion tensor imaging parameters. Prospective motion correction was shown to produce smaller changes.


Assuntos
Artefatos , Encéfalo/anatomia & histologia , Imagem de Tensor de Difusão/métodos , Movimentos da Cabeça , Aumento da Imagem/métodos , Imageamento Tridimensional/métodos , Algoritmos , Criança , Pré-Escolar , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Movimento (Física) , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Técnica de Subtração
14.
Neuroimage ; 93 Pt 2: 252-9, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23702414

RESUMO

Recent advancements in radio frequency coils, field strength and sophisticated pulse sequences have propelled modern brain mapping and have made validation to biological standards - histology and pathology - possible. The medial temporal lobe has long been established as a pivotal brain region for connectivity, function and unique structure in the human brain, and reveals disconnection in mild Alzheimer's disease. Specific brain mapping of mesocortical areas affected with neurofibrillary tangle pathology early in disease progression provides not only an accurate description for location of these areas but also supplies spherical coordinates that allow comparison between other ex vivo cases and larger in vivo datasets. We have identified several cytoarchitectonic features in the medial temporal lobe with high resolution ex vivo MRI, including gray matter structures such as the entorhinal layer II 'islands', perirhinal layer II-III columns, presubicular 'clouds', granule cell layer of the dentate gyrus as well as lamina of the hippocampus. Localization of Brodmann areas 28 and 35 (entorhinal and perirhinal, respectively) demonstrates MRI based area boundaries validated with multiple methods and histological stains. Based on our findings, both myelin and Nissl staining relate to contrast in ex vivo MRI. Precise brain mapping serves to create modern atlases for cortical areas, allowing accurate localization with important applications to detecting early disease processes.


Assuntos
Mapeamento Encefálico , Imageamento por Ressonância Magnética , Lobo Temporal/anatomia & histologia , Humanos
15.
Neuroimage ; 88: 22-31, 2014 03.
Artigo em Inglês | MEDLINE | ID: mdl-24201013

RESUMO

The full potential of magnetic resonance spectroscopic imaging (MRSI) is often limited by localization artifacts, motion-related artifacts, scanner instabilities, and long measurement times. Localized adiabatic selective refocusing (LASER) provides accurate B1-insensitive spatial excitation even at high magnetic fields. Spiral encoding accelerates MRSI acquisition, and thus, enables 3D-coverage without compromising spatial resolution. Real-time position- and shim/frequency-tracking using MR navigators correct motion- and scanner instability-related artifacts. Each of these three advanced MRI techniques provides superior MRSI data compared to commonly used methods. In this work, we integrated in a single pulse sequence these three promising approaches. Real-time correction of motion, shim, and frequency-drifts using volumetric dual-contrast echo planar imaging-based navigators were implemented in an MRSI sequence that uses low-power gradient modulated short-echo time LASER localization and time efficient spiral readouts, in order to provide fast and robust 3D-MRSI in the human brain at 3T. The proposed sequence was demonstrated to be insensitive to motion- and scanner drift-related degradations of MRSI data in both phantoms and volunteers. Motion and scanner drift artifacts were eliminated and excellent spectral quality was recovered in the presence of strong movement. Our results confirm the expected benefits of combining a spiral 3D-LASER-MRSI sequence with real-time correction. The new sequence provides accurate, fast, and robust 3D metabolic imaging of the human brain at 3T. This will further facilitate the use of 3D-MRSI for neuroscience and clinical applications.


Assuntos
Encéfalo/diagnóstico por imagem , Encéfalo/metabolismo , Imageamento Tridimensional/métodos , Espectroscopia de Ressonância Magnética/métodos , Adulto , Feminino , Humanos , Imageamento Tridimensional/normas , Espectroscopia de Ressonância Magnética/normas , Masculino , Imagens de Fantasmas
16.
Neuroimage ; 90: 60-73, 2014 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-24345388

RESUMO

The Magnetization-Prepared 2 Rapid Acquisition Gradient Echo (MP2RAGE) method achieves spatially uniform contrast across the entire brain between gray matter and surrounding white matter tissue and cerebrospinal fluid by rapidly acquiring data at two points during an inversion recovery, and then combining the two volumes so as to cancel out sources of intensity and contrast bias, making it useful for neuroimaging studies at ultrahigh field strengths (≥7T). To quantify the effectiveness of the MP2RAGE method for quantitative morphometric neuroimaging, we performed tissue segmentation and cerebral cortical surface reconstruction of the MP2RAGE data and compared the results with those generated from conventional multi-echo MPRAGE (MEMPRAGE) data across a group of healthy subjects. To do so, we developed a preprocessing scheme for the MP2RAGE image data to allow for automatic cortical segmentation and surface reconstruction using FreeSurfer and analysis methods to compare the positioning of the surface meshes. Using image volumes with 1mm isotropic voxels we found a scan-rescan reproducibility of cortical thickness estimates to be 0.15 mm (or 6%) for the MEMPRAGE data and a slightly lower reproducibility of 0.19 mm (or 8%) for the MP2RAGE data. We also found that the thickness estimates were systematically smaller in the MP2RAGE data, and that both the interior and exterior cortical boundaries estimated from the MP2RAGE data were consistently positioned within the corresponding boundaries estimated from the MEMPRAGE data. Therefore several measureable differences exist in the appearance of cortical gray matter and its effect on automatic segmentation methods that must be considered when choosing an acquisition or segmentation method for studies requiring cortical surface reconstructions. We propose potential extensions to the MP2RAGE method that may help to reduce or eliminate these discrepancies.


Assuntos
Mapeamento Encefálico/métodos , Encéfalo/anatomia & histologia , Processamento de Imagem Assistida por Computador/métodos , Humanos , Imageamento por Ressonância Magnética
17.
Neuroimage ; 103: 290-302, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25255945

RESUMO

Gamma-aminobutyric acid (GABA) and glutamate (Glu) are the major neurotransmitters in the brain. They are crucial for the functioning of healthy brain and their alteration is a major mechanism in the pathophysiology of many neuro-psychiatric disorders. Magnetic resonance spectroscopy (MRS) is the only way to measure GABA and Glu non-invasively in vivo. GABA detection is particularly challenging and requires special MRS techniques. The most popular is MEscher-GArwood (MEGA) difference editing with single-voxel Point RESolved Spectroscopy (PRESS) localization. This technique has three major limitations: a) MEGA editing is a subtraction technique, hence is very sensitive to scanner instabilities and motion artifacts. b) PRESS is prone to localization errors at high fields (≥3T) that compromise accurate quantification. c) Single-voxel spectroscopy can (similar to a biopsy) only probe steady GABA and Glu levels in a single location at a time. To mitigate these problems, we implemented a 3D MEGA-editing MRS imaging sequence with the following three features: a) Real-time motion correction, dynamic shim updates, and selective reacquisition to eliminate subtraction artifacts due to scanner instabilities and subject motion. b) Localization by Adiabatic SElective Refocusing (LASER) to improve the localization accuracy and signal-to-noise ratio. c) K-space encoding via a weighted stack of spirals provides 3D metabolic mapping with flexible scan times. Simulations, phantom and in vivo experiments prove that our MEGA-LASER sequence enables 3D mapping of GABA+ and Glx (Glutamate+Gluatmine), by providing 1.66 times larger signal for the 3.02ppm multiplet of GABA+ compared to MEGA-PRESS, leading to clinically feasible scan times for 3D brain imaging. Hence, our sequence allows accurate and robust 3D-mapping of brain GABA+ and Glx levels to be performed at clinical 3T MR scanners for use in neuroscience and clinical applications.


Assuntos
Encéfalo/metabolismo , Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Processamento de Sinais Assistido por Computador , Ácido gama-Aminobutírico/análise , Adulto , Artefatos , Química Encefálica/fisiologia , Feminino , Humanos , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética , Masculino
18.
Hippocampus ; 24(11): 1267-86, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25154857

RESUMO

H.M., Henry Molaison, was one of the world's most famous amnesic patients. His amnesia was caused by an experimental brain operation, bilateral medial temporal lobe resection, carried out in 1953 to relieve intractable epilepsy. He died on December 2, 2008, and that night we conducted a wide variety of in situ MRI scans in a 3 T scanner at the Massachusetts General Hospital (Mass General) Athinoula A. Martinos Center for Biomedical Imaging. For the in situ experiments, we acquired a full set of standard clinical scans, 1 mm isotropic anatomical scans, and multiple averages of 440 µm isotropic anatomical scans. The next morning, H.M.'s body was transported to the Mass General Morgue for autopsy. The photographs taken at that time provided the first documentation of H.M.'s lesions in his physical brain. After tissue fixation, we obtained ex vivo structural data at ultra-high resolution using 3 T and 7 T magnets. For the ex vivo acquisitions, the highest resolution images were 210 µm isotropic. Based on the MRI data, the anatomical areas removed during H.M.'s experimental operation were the medial temporopolar cortex, piriform cortex, virtually all of the entorhinal cortex, most of the perirhinal cortex and subiculum, the amygdala (except parts of the dorsal-most nuclei-central and medial), anterior half of the hippocampus, and the dentate gyrus (posterior head and body). The posterior parahippocampal gyrus and medial temporal stem were partially damaged. Spared medial temporal lobe tissue included the dorsal-most amygdala, the hippocampal-amygdalo-transition-area, ∼2 cm of the tail of the hippocampus, a small part of perirhinal cortex, a small portion of medial hippocampal tissue, and ∼2 cm of posterior parahippocampal gyrus. H.M.'s impact on the field of memory has been remarkable, and his contributions to neuroscience continue with a unique dataset that includes in vivo, in situ, and ex vivo high-resolution MRI.


Assuntos
Amnésia/patologia , Encéfalo/patologia , Amnésia/história , Autopsia , Epilepsia/história , Epilepsia/patologia , Epilepsia/cirurgia , História do Século XX , Humanos , Imageamento por Ressonância Magnética , Masculino , Memória
19.
J Magn Reson Imaging ; 40(4): 958-65, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24924772

RESUMO

PURPOSE: To evaluate B0 shim and motion navigated single voxel spectroscopy in children. Assess the repeatability of metabolite concentrations in three regions: medial frontal grey matter, peritrigonal white matter, and basal ganglia. Determine the extent of intra- and interacquisition movement in this population. METHODS: Linewidth and signal to noise ratio were calculated to assess spectral quality of 186 spectra at 3 Tesla. Repeatability was assessed on 31 repeat scans. Navigator images were used to assess localization errors, while navigator motion and shim logs were used to demonstrate the efficacy of correction needed during the scans. RESULTS: Average linewidths ± standard deviations of N-acetyl aspartate are 3.8 ± 0.6 Hz, 4.4 ± 0.5 Hz, and 4.7 ± 0.8 Hz in each region, respectively. Scan-to-scan measurement variance in metabolite concentrations closely resembled the expected variance. A total of 73% and 32% of children moved before and during the acquisition, causing a voxel shift of more than 10% of the voxel volume, 1.5 mm. The predominant movement directions were sliding out of the coil and nodding (up-down rotation). First-order B0 corrections were significant (>10 µT/m) in 18 % of acquisitions. CONCLUSION: Prospective motion and B0 correction provides high quality repeatable spectra. The study found that most children moved between acquisitions and a substantial number moved during acquisitions.


Assuntos
Algoritmos , Artefatos , Encéfalo/metabolismo , Espectroscopia de Ressonância Magnética/métodos , Movimento , Pré-Escolar , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
20.
Metab Brain Dis ; 29(2): 323-32, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24488204

RESUMO

Single voxel spectroscopy (SVS) can generate useful information regarding metabolite concentrations provided that the MR signal can be averaged over several minutes during which the subject remains stationary. This requirement can be particularly challenging for children who cannot otherwise be scanned without sedation. To address this problem we developed an EPI volume navigated (vNav) SVS PRESS sequence, which applies real-time head pose (location and orientation), frequency, and first-order B0 shim adjustments. A water-independent preprocessing algorithm removes residual frequency and phase shifts resulting from within-TR movements. We compare results and performance of the standard and vNav PRESS sequences in a sample of 9- to 10-year-olds from a South African cohort of children with fetal alcohol spectrum disorders (FASD) and healthy controls. Magnetic resonance spectroscopy (MRS) data in the deep cerebellar nuclei were initially acquired with the standard PRESS sequence. The children were re-scanned 1 year later with the vNav PRESS sequence. Good quality data were acquired in 73% using the vNav PRESS sequence, compared to only 50% for the standard PRESS sequence. Additionally, tighter linewidths and smaller variances in the measured concentrations were observed. These findings confirm previous reports demonstrating the efficacy of our innovative vNav sequence with healthy volunteers and young children with HIV and expand its application to a school-aged population with FASD-disorders often associated with attention problems and hyperactivity. This study provides the most direct evidence to date regarding degree to which these new methods can improve data quality in research studies employing MRS.


Assuntos
Transtornos do Espectro Alcoólico Fetal/diagnóstico , Transtornos do Espectro Alcoólico Fetal/metabolismo , Espectroscopia de Ressonância Magnética/métodos , Estatística como Assunto/métodos , Estudantes , Criança , Feminino , Transtornos do Espectro Alcoólico Fetal/psicologia , Humanos , Estudos Longitudinais , Masculino , Gravidez , Estudantes/psicologia
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa