Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
J Cardiovasc Electrophysiol ; 33(12): 2517-2527, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36104929

RESUMO

INTRODUCTION: Approaches applying higher energy levels for shorter periods (high power short duration, HPSD) to improve lesion formation for atrial fibrillation (AF) ablation have been introduced. This single-center study aimed to compare the efficacy, safety, and lesion formation using the novel DiamondTemp (DT) catheter or an ablation index (AI)-guided HPSD ablation protocol using a force-sensing catheter with surround-flow irrigation. METHODS: One hundred thirteen consecutive patients undergoing radiofrequency-guided catheter ablation (RFCA) for AF were included. Forty-five patients treated with the DT catheter (50 W, 9 s), were compared to 68 consecutive patients undergoing AI-guided ablation (AI anterior 550; AI posterior 400) adherent to a 50 W HPSD protocol. Procedural data and AF recurrence were evaluated. RESULTS: Acute procedural success was achieved in all patients (n = 113, 100%). DT-guided AF ablation was associated with a longer mean procedure duration (99.10 ± 28.30 min vs. 78.24 ± 25.55, p < .001) and more RF applications (75.24 ± 30.76 min vs. 61.27 ± 14.06, p = .019). RF duration (792.13 ± 311.23 s vs. 1035.54 ± 287.24 s, p < .001) and fluoroscopy dose (183.81 ± 178.13 vs. 295.80 ± 247.54 yGym2 , p = .013) were lower in the DT group. AI-guided HPSD was associated with a higher AF-free survival rate without reaching statistical significance (p = .088). Especially patients with PERS AF (p = .009) as well as patients with additional atrial arrhythmia substrate (p = .002) benefited from an AI-guided ablation strategy. CONCLUSION: Temperature- and AI- controlled HPSD RFCA using 50 W was safe and effective. AI-guided HPSD ablation seems to be associated with shorter procedure durations and fewer RF applications. Particularly in advanced AF, freedom from AF-recurrence may be improved using an AI-guided HPSD approach.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Ablação por Radiofrequência , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/etiologia , Veias Pulmonares/cirurgia , Temperatura , Resultado do Tratamento , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Recidiva
2.
Indian Pacing Electrophysiol J ; 22(4): 200-206, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35642824

RESUMO

BACKGROUND: Ablation index (AI)-guided ablation for posterior wall isolation (PWI) using high-power, short-duration remains untested. We sought to evaluate the acute outcomes of AI-guided 50 W ablation vs. conventional ablation, and investigate the differences in relationship between contact force (CF), time and AI in both groups. METHODS: Consecutive patients undergoing first-time AI-guided ablation with PWI using either 50 W or 35-40 W ablation were enrolled. Acute procedural metrics and individual lesion level ablation data were compared between groups. RESULTS: 40 patients (50 W: n = 20, 35-40 W: n = 20) with atrial fibrillation were included. Total procedure time was significantly reduced with 50 W (120 vs. 143 mins, p = 0.004) and there was a trend toward decreased ablation time (22 vs. 28 mins, p = 0.052). First pass and acute success of PWI were comparable between the 50 W and 35-40 W groups (10 vs. 8 patients, p = 0.525 and 20 vs. 19 patients, p = 1.000, respectively). Individual lesion analysis of all 959 RF applications (50 W: n = 458, 35-40 W: n = 501) demonstrated that 50 W ablation led to lower ablation time per lesion (10.4 vs. 13.0s, p < 0.001), and increased AI (471 vs. 461, p < 0.001) and impedance drop (7.4 vs. 6.9ohms, p = 0.007). Excessive ablations (AI>600 for roof line; AI>500 elsewhere) were more frequently observed in the 50 W group (9.0% vs. 4.6%, p = 0.007). CF had very good discriminative capability for excessive ablation in both groups. At 50 W, limiting the CF to <10 g reduced the number of excessive ablations on the floor line and within the posterior box to 12% and 4%,respectively. Recurrence of atrial arrhythmias at 12 months were comparable between the groups. CONCLUSION: AI-guided 50 W RF ablation reduces the ablation time of individual lesions and total procedure time without compromising first pass and acute success rates of PWI or 12-month outcomes compared to conventional powers.

3.
Europace ; 23(6): 878-886, 2021 06 07.
Artigo em Inglês | MEDLINE | ID: mdl-33693677

RESUMO

AIMS: The safety of Ablation Index (AI)-guided 50 W ablation for atrial fibrillation (AF) remains uncertain, and mid-term clinical outcomes have not been described. The interplay between AI and its components at 50 W has not been reported. METHODS AND RESULTS: Eighty-eight consecutive AF patients (44% paroxysmal) underwent AI-guided 50 W ablation. Procedural and 12-month clinical outcomes were compared with 93 consecutive controls (65% paroxysmal) who underwent AI-guided ablation using 35-40 W. Posterior wall isolation (PWI) was performed in 44 (50%) and 23 (25%) patients in the 50 and 35-40 W groups, respectively, P < 0.001. The last 10 patients from each group underwent analysis of individual lesions (n = 1230) to explore relationships between different powers and the AI components. Pulmonary vein isolation was successful in all patients. Posterior wall isolation was successful in 41/44 (93.2%) and 22/23 (95.7%) in the 50 and 35-40 W groups, respectively (P = 0.685). Radiofrequency times (20 vs. 26 min, P < 0.001) and total procedure times (130 vs. 156 min, P = 0.002) were significantly lower in the 50 W group. No complication or steam pop was seen in either group. Twelve-month freedom from arrhythmia was similar (80.2% vs. 82.8%, P = 0.918). A higher proportion of lesions in the 50 W group were associated with impedance drop >7 Ω (54.6% vs. 45.5%, P < 0.001). Excessive ablation (AI >600 anteriorly, >500 posteriorly) was more frequent in the 50 W group (9.7% vs. 4.3%, P < 0.001). CONCLUSION: Ablation Index-guided 50 W AF ablation is as safe and effective as lower powers and results in reduced ablation and procedure times. Radiofrequency lesions are more likely to be therapeutic, but there is a higher risk of delivering excessive ablation.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Benchmarking , Ablação por Cateter/efeitos adversos , Humanos , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
4.
Toxicol Rep ; 9: 323-336, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35284242

RESUMO

A ninety-day oral toxicity study of saponified Capsicum annum fruit extract with 50% (w/w) capsanthin (SCFE-50 C) was performed by oral gavage administration to male and female Sprague-Dawley (SD) rats at doses of 0, 500, 1000 and 2000 mg/kg BW/day for a period of ninety consecutive days. To assess the reversal of toxicity, the treatment phase was followed with a twenty-eight-day recovery period. The treatment with SCFE-50 C in both male and female SD rats showed no mortality, and no treatment-related toxicologically significant changes were observed in any groups. No significant differences between treated and control groups were found in feed consumption, body weight gain, individual organ weights, ocular examination, clinical chemistry or blood biochemistry. The necroscopy and histopathology examination did not reveal any clinically significant changes in male and female rats from the 2000 mg/kg BW/day group. According to this study, the no observable adverse effect level (NOAEL) for saponified Capsicum annum fruit extract with 50% (w/w) capsanthin (SCFE-50 C) administered by oral gavage for 90-days is > 2000 mg/kg BW/day in SD rats.

5.
J Food Sci Technol ; 48(3): 296-304, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23572750

RESUMO

Lemon juices clarified with enzymatic treatment with and without cation exchange resin treatment were concentrated to 60(o) Brix in a vacuum evaporator and converted into powders by foam mat drying technique. Powders obtained from cation exchange resin treated juice were better in quality with respect to acidity, glucose, fructose, sugars, and ascorbic acid contents as compared to those prepared form non treated juice. Further, during 9 months storage, the powders suffered slight loss of acidity, and increase in reducing sugars i.e. glucose and fructose and considerable loss (31-55%) in vitamin C contents. Storage conditions did not bring about any significant change in the ash and hesperidin content of the product. But some losses were registered in the total phenols (23.69%) and sensory quality (from 7.72 to 7.26) of the powders. Further, the powders prepared from cation exchange resin treated juice and those pulverized with cane sugar suffered overall lesser changes in most of the quality parameters during 9 months of storage, thus indicating that, the treatment of lemon juice with cation exchange resin is beneficial for better initial product quality and pulverization of prepared powder with cane sugar is beneficial in reducing the hygroscopicity and retention of quality in a better way.

6.
Anal Sci ; 36(6): 769-773, 2020 Jun 10.
Artigo em Inglês | MEDLINE | ID: mdl-31932521

RESUMO

Xylitol separation from a polyol mixture of the byproducts from bioethanol production processes was performed by liquid chromatography using short columns packed with lanthanide ion-loaded ion-exchange resins. Xylitol was successfully separated with sufficiently high resolution using adsorbents with medium rare-earth metal ions, such as Nd3+ and Sm3+. The adsorbents' specific nature is explained by the so-called "gadolinium break," which is known as a discontinuous behavior of thermodynamic parameters in complexation of the lanthanide series. From the observed behavior, the optimum lanthanide ions could be chosen to prepare appropriate adsorbents for ligand-exchange chromatography of given polyol mixtures.

7.
Anal Chim Acta ; 787: 78-86, 2013 Jul 17.
Artigo em Inglês | MEDLINE | ID: mdl-23830424

RESUMO

Chelex-100, Dowex 50W-x8 and Dowex MAC-3 exchange resins were investigated for separation and pre-concentration of trace amounts of Cd, Cr, Cu, Fe, Mn, Pb, Ti and Zn in alcohols with respect to retention and desorption characteristics. Dowex 50W-x8 was found to be the best sorbent with percentages recoveries >95%. In addition, Chelex-100 appeared to be suitable for the pre-concentration of Cu, Fe and Zn, whereas Dowex MAC-3 was selective for Cu and Fe. Therefore, Dowex 50W-x8 was used for further investigations. The relative standard deviations <4% (n=20), limits of detection and quantification were 0.1-1.2 µg L(-1) and 0.3-1.5 µg L(-1), respectively. The SPE method was validated against a certified reference material and the results were in agreement with certified values. The accuracy of the optimized method was verified by the recovery test in the spiked alcohol samples. The accuracy and spike recovery test for different metal ions were in the range 98-102% and 95-105%, respectively. The optimized method was applied to the separation and pre-concentration of metal ions in different commercial alcohol samples.


Assuntos
Álcoois/análise , Resinas de Troca de Cátion/química , Espectrofotometria Atômica/métodos , Oligoelementos/análise , 2-Propanol/análise , 2-Propanol/química , Álcoois/química , Butanóis/análise , Butanóis/química , Etanol/análise , Etanol/química , Metanol/análise , Metanol/química , Oligoelementos/química
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa