Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 163
Filtrar
1.
J Neurosci ; 43(42): 7028-7040, 2023 10 18.
Artigo em Inglês | MEDLINE | ID: mdl-37669861

RESUMO

Parkinson's disease (PD) and progressive supranuclear palsy (PSP) both impair response inhibition, exacerbating impulsivity. Inhibitory control deficits vary across individuals and are linked with worse prognosis, and lack improvement on dopaminergic therapy. Motor and cognitive control are associated with noradrenergic innervation of the cortex, arising from the locus coeruleus (LC) noradrenergic system. Here we test the hypothesis that structural variation of the LC explains response inhibition deficits in PSP and PD. Twenty-four people with idiopathic PD, 14 with PSP-Richardson's syndrome, and 24 age- and sex-matched controls undertook a stop-signal task and ultrahigh field 7T magnetization-transfer-weighted imaging of the LC. Parameters of "race models" of go- versus stop-decisions were estimated using hierarchical Bayesian methods to quantify the cognitive processes of response inhibition. We tested the multivariate relationship between LC integrity and model parameters using partial least squares. Both disorders impaired response inhibition at the group level. PSP caused a distinct pattern of abnormalities in inhibitory control with a paradoxically reduced threshold for go responses, but longer nondecision times, and more lapses of attention. The variation in response inhibition correlated with the variability of LC integrity across participants in both clinical groups. Structural imaging of the LC, coupled with behavioral modeling in parkinsonian disorders, confirms that LC integrity is associated with response inhibition and LC degeneration contributes to neurobehavioral changes. The noradrenergic system is therefore a promising target to treat impulsivity in these conditions. The optimization of noradrenergic treatment is likely to benefit from stratification according to LC integrity.SIGNIFICANCE STATEMENT Response inhibition deficits contribute to clinical symptoms and poor outcomes in people with Parkinson's disease and progressive supranuclear palsy. We used cognitive modeling of performance of a response inhibition task to identify disease-specific mechanisms of abnormal inhibitory control. Response inhibition in both patient groups was associated with the integrity of the noradrenergic locus coeruleus, which we measured in vivo using ultra-high field MRI. We propose that the imaging biomarker of locus coeruleus integrity provides a trans-diagnostic tool to explain individual differences in response inhibition ability beyond the classic nosological borders and diagnostic criteria. Our data suggest a potential new stratified treatment approach for Parkinson's disease and progressive supranuclear palsy.


Assuntos
Doença de Parkinson , Transtornos Parkinsonianos , Paralisia Supranuclear Progressiva , Humanos , Paralisia Supranuclear Progressiva/diagnóstico por imagem , Paralisia Supranuclear Progressiva/psicologia , Doença de Parkinson/complicações , Doença de Parkinson/diagnóstico por imagem , Locus Cerúleo , Teorema de Bayes
2.
Neurobiol Dis ; 190: 106372, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38061397

RESUMO

Gait disturbance is a manifestation of cerebral small vessel disease (CSVD). The posterolateral thalamus (PL), whose blood is mainly supplied by the P2 segment of posterior cerebral artery (P2-PCA), plays pivotal roles in gait regulation. We investigated the influence of the distance between P2-PCA and PL on gait with varying CSVD burden. 71 participants were divided into low and high CSVD burden groups. The distance from P2-PCA to PL was measured using 7 T TOF-MRA and categorized into an immediate or distant PCA-to-thalamus pattern. Functional connectivity (FC) and voxel-based morphometry were assessed to evaluate functional and structural alterations. In the low CSVD burden group, immediate PCA-to-thalamus supply strongly correlates with longer step length and higher wave phase time percent, and exhibited enhanced FCs in left supplementary motor area, right precentral cortex (PreCG.R). While in the high CSVD burden group, no association between PCA-to-thalamus pattern and gait was found, and we observed reduced FC in PreCG.R with immediate PCA-to-thalamus pattern. Higher CSVD burden was associated with decreased gray matter density in bilateral thalamus. However, no significant structural thalamic change was observed between the two types of PCA-to-thalamus patterns in all patients. Our study demonstrated patients with immediate PCA-to-thalamus supply exhibited better gait performance in low CSVD burden populations, which also correlated with enhanced FCs in motor-related cortex, indicating the beneficial effects of the immediate PCA-to-thalamus supply pattern. In the higher burden CSVD populations, the effects of PCA-to-thalamus pattern on gait are void, attributable to the CSVD-related thalamic destruction and impairment of thalamus-related FC.


Assuntos
Doenças de Pequenos Vasos Cerebrais , Artéria Cerebral Posterior , Humanos , Doenças de Pequenos Vasos Cerebrais/diagnóstico por imagem , Substância Cinzenta , Imageamento por Ressonância Magnética , Tálamo/diagnóstico por imagem
3.
Hum Brain Mapp ; 45(3): e26597, 2024 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-38375948

RESUMO

Although functional magnetic resonance imaging (fMRI) is widely applied in the brain, fMRI of the spinal cord is more technically demanding. Proximity to the vertebral column and lungs results in strong spatial inhomogeneity and temporal fluctuations in B0 . Increasing field strength enables higher spatial resolution and improved sensitivity to blood oxygenation level-dependent (BOLD) signal, but amplifies the effects of B0 inhomogeneity. In this work, we present the first task fMRI in the spinal cord at 7 T. Further, we compare the performance of single-shot and multi-shot 2D echo-planar imaging (EPI) protocols, which differ in sensitivity to spatial and temporal B0 inhomogeneity. The cervical spinal cords of 11 healthy volunteers were scanned at 7 T using single-shot 2D EPI at 0.75 mm in-plane resolution and multi-shot 2D EPI at 0.75 and 0.6 mm in-plane resolutions. All protocols used 3 mm slice thickness. For each protocol, the BOLD response to 13 10-s noxious thermal stimuli applied to the right thumb was acquired in a 10-min fMRI run. Image quality, temporal signal to noise ratio (SNR), and BOLD activation (percent signal change and z-stat) at both individual- and group-level were evaluated between the protocols. Temporal SNR was highest in single-shot and multi-shot 0.75 mm protocols. In group-level analyses, activation clusters appeared in all protocols in the ipsilateral dorsal quadrant at the expected C6 neurological level. In individual-level analyses, activation clusters at the expected level were detected in some, but not all subjects and protocols. Single-shot 0.75 mm generally produced the highest mean z-statistic, while multi-shot 0.60 mm produced the best-localized activation clusters and the least geometric distortion. Larger than expected within-subject segmental variation of BOLD activation along the cord was observed. Group-level sensory task fMRI of the cervical spinal cord is feasible at 7 T with single-shot or multi-shot EPI. The best choice of protocol will likely depend on the relative importance of sensitivity to activation versus spatial localization of activation for a given experiment. PRACTITIONER POINTS: First stimulus task fMRI results in the spinal cord at 7 T. Single-shot 0.75 mm 2D EPI produced the highest mean z-statistic. Multi-shot 0.60 mm 2D EPI provided the best-localized activation and least distortion.


Assuntos
Medula Cervical , Imageamento por Ressonância Magnética , Humanos , Imageamento por Ressonância Magnética/métodos , Medula Cervical/diagnóstico por imagem , Imagem Ecoplanar/métodos , Medula Espinal/diagnóstico por imagem , Medula Espinal/patologia , Encéfalo/diagnóstico por imagem , Encéfalo/fisiologia
4.
Magn Reson Med ; 92(2): 869-880, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38469911

RESUMO

PURPOSE: Ultra-high field MRI offers unprecedented detail for noninvasive visualization of the human brain. However, brain imaging is challenging at 7T due to the B 1 + $$ {}_1^{+} $$ field inhomogeneity, which results in signal intensity drops in temporal lobes and a bright region in the brain center. This study aims to evaluate using a metasurface to improve brain imaging at 7T and simplify the investigative workflow. METHODS: Two flexible metasurfaces comprising a periodic structure of copper strips and parallel-plate capacitive elements printed on an ultra-thin substrate were optimized for brain imaging and implemented via PCB. We considered two setups: (1) two metasurfaces located near the temporal lobes and (2) one metasurface placed near the occipital lobe. The effect of metasurface placement on the transmit efficiency and specific absorption rate was evaluated via electromagnetic simulation studies with voxelized models. In addition, their impact on signal-to-noise ratio (SNR) and diagnostic image quality was assessed in vivo for two male and one female volunteers. RESULTS: Placement of metasurfaces near the regions of interest led to an increase in homogeneity of the transmit field by 5% and 10.5% in the right temporal lobe and occipital lobe for a male subject, respectively. SAR efficiency values changed insignificantly, dropping by less than 8% for all investigated setups. In vivo studies also confirmed the numerically predicted improvement in field distribution and receive sensitivity in the desired ROI. CONCLUSION: Optimized metasurfaces enable homogenizing transmit field distribution in the brain at 7T. The proposed lightweight and flexible structure can potentially provide MR examination with higher diagnostic value images.


Assuntos
Encéfalo , Imageamento por Ressonância Magnética , Razão Sinal-Ruído , Humanos , Imageamento por Ressonância Magnética/métodos , Encéfalo/diagnóstico por imagem , Masculino , Feminino , Desenho de Equipamento , Imagens de Fantasmas , Processamento de Imagem Assistida por Computador/métodos , Simulação por Computador , Adulto , Algoritmos
5.
Neuroimage ; 276: 120185, 2023 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-37244320

RESUMO

OBJECTIVE: Blood-oxygen-level-dependent functional MRI allows to investigte neural activities and connectivity. While the non-human primate plays an essential role in neuroscience research, multimodal methods combining functional MRI with other neuroimaging and neuromodulation enable us to understand the brain network at multiple scales. APPROACH: In this study, a tight-fitting helmet-shape receive array with a single transmit loop for anesthetized macaque brain MRI at 7T was fabricated with four openings constructed in the coil housing to accommodate multimodal devices, and the coil performance was quantitatively evaluated and compared to a commercial knee coil. In addition, experiments over three macaques with infrared neural stimulation (INS), focused ultrasound stimulation (FUS), and transcranial direct current stimulation (tDCS) were conducted. MAIN RESULTS: The RF coil showed higher transmit efficiency, comparable homogeneity, improved SNR and enlarged signal coverage over the macaque brain. Infrared neural stimulation was applied to the amygdala in deep brain region, and activations in stimulation sites and connected sites were detected, with the connectivity consistent with anatomical information. Focused ultrasound stimulation was applied to the left visual cortex, and activations were acquired along the ultrasound traveling path, with all time course curves consistent with pre-designed paradigms. The existence of transcranial direct current stimulation electrodes brought no interference to the RF system, as evidenced through high-resolution MPRAGE structure images. SIGNIFICANCE: This pilot study reveals the feasibility for brain investigation at multiple spatiotemporal scales, which may advance our understanding in dynamic brain networks.


Assuntos
Estimulação Transcraniana por Corrente Contínua , Animais , Haplorrinos , Projetos Piloto , Imageamento por Ressonância Magnética , Neuroimagem , Encéfalo/diagnóstico por imagem , Macaca , Desenho de Equipamento , Imagens de Fantasmas , Ondas de Rádio , Razão Sinal-Ruído
6.
Hum Brain Mapp ; 44(2): 825-840, 2023 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-36217746

RESUMO

Whole brain ionic and metabolic imaging has potential as a powerful tool for the characterization of brain diseases. We combined sodium MRI (23 Na MRI) and 1 H-MR Spectroscopic Imaging (1 H-MRSI), assessing changes within epileptogenic networks in comparison with electrophysiologically normal networks as defined by stereotactic EEG (SEEG) recordings analysis. We applied a multi-echo density adapted 3D projection reconstruction pulse sequence at 7 T (23 Na-MRI) and a 3D echo-planar spectroscopic imaging sequence at 3 T (1 H-MRSI) in 19 patients suffering from drug-resistant focal epilepsy who underwent presurgical SEEG. We investigated 23 Na MRI parameters including total sodium concentration (TSC) and the sodium signal fraction associated with the short component of T2 * decay (f), alongside the level of metabolites N-acetyl aspartate (NAA), choline compounds (Cho), and total creatine (tCr). All measures were extracted from spherical regions of interest (ROIs) centered between two adjacent SEEG electrode contacts and z-scored against the same ROI in controls. Group comparison showed a significant increase in f only in the epileptogenic zone (EZ) compared to controls and compared to patients' propagation zone (PZ) and non-involved zone (NIZ). TSC was significantly increased in all patients' regions compared to controls. Conversely, NAA levels were significantly lower in patients compared to controls, and lower in the EZ compared to PZ and NIZ. Multiple regression analyzing the relationship between sodium and metabolites levels revealed significant relations in PZ and in NIZ but not in EZ. Our results are in agreement with the energetic failure hypothesis in epileptic regions associated with widespread tissue reorganization.


Assuntos
Epilepsia , Prótons , Humanos , Imageamento por Ressonância Magnética/métodos , Eletroencefalografia/métodos , Epilepsia/diagnóstico por imagem , Epilepsia/cirurgia , Epilepsia/metabolismo , Sódio/metabolismo
7.
Hum Brain Mapp ; 44(5): 1868-1875, 2023 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-36478470

RESUMO

Visual snow syndrome (VSS) is a neurological disorder characterized by a range of continuous visual disturbances. Little is known about the functional pathological mechanisms underlying VSS and their effect on brain network topology, studied using high-resolution resting-state (RS) 7 T MRI. Forty VSS patients and 60 healthy controls underwent RS MRI. Functional connectivity matrices were calculated, and global efficiency (network integration), modularity (network segregation), local efficiency (LE, connectedness neighbors) and eigenvector centrality (significance node in network) were derived using a dynamic approach (temporal fluctuations during acquisition). Network measures were compared between groups, with regions of significant difference correlated with known aberrant ocular motor VSS metrics (shortened latencies and higher number of inhibitory errors) in VSS patients. Lastly, nodal co-modularity, a binary measure of node pairs belonging to the same module, was studied. VSS patients had lower modularity, supramarginal centrality and LE dynamics of multiple (sub)cortical regions, centered around occipital and parietal lobules. In VSS patients, lateral occipital cortex LE dynamics correlated positively with shortened prosaccade latencies (p = .041, r = .353). In VSS patients, occipital, parietal, and motor nodes belonged more often to the same module and demonstrated lower nodal co-modularity with temporal and frontal regions. This study revealed reduced dynamic variation in modularity and local efficiency strength in the VSS brain, suggesting that brain network dynamics are less variable in terms of segregation and local clustering. Further investigation of these changes could inform our understanding of the pathogenesis of the disorder and potentially lead to treatment strategies.


Assuntos
Encéfalo , Transtornos da Visão , Humanos , Encéfalo/diagnóstico por imagem , Imageamento por Ressonância Magnética , Lobo Occipital , Lobo Parietal
8.
Magn Reson Med ; 89(1): 77-94, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36128895

RESUMO

PURPOSE: To evaluate the benefits and challenges of dynamic parallel transmit (pTx) pulses for fat saturation (FS) and water-excitation (WE), in the context of CEST MRI. METHODS: "Universal" kT -points (for FS) and spiral non-selective (for WE) trajectories were optimized offline for flip angle (FA) homogeneity. Routines to optimize the pulse shape online, based on the subject's fields maps, were implemented (target FA of 110°/0° for FS, 0°/5° for WE at fat/water frequencies). The pulses were inserted in a CEST sequence with a pTx readout. The different fat suppression schemes and their effects on CEST contrasts were compared in 12 volunteers at 7T. RESULTS: With a 25%-shorter pulse duration, pTx FS largely improved the FA homogeneity (root-mean-square-error (RMSE) = 12.3° vs. 53.4° with circularly-polarized mode, at the fat frequency). However, the spectral selectivity was degraded mainly in the cerebellum and close to the sinuses (RMSE = 5.8° vs. 0.2° at the water frequency). Similarly, pTx WE showed a trade-off between FA homogeneity and spectral selectivity compared to pTx non-selective pulses (RMSE = 0.9° and 1.1° at the fat and water frequencies, vs. 4.6° and 0.5°). In the brain, CEST metrics were reduced by up to 31.9% at -3.3 ppm with pTx FS, suggesting a mitigated lipid-induced bias. CONCLUSION: This clinically compatible implementation of dynamic pTx pulses improved the fat suppression homogeneity at 7T taking into account the subject-specific B0 heterogeneities online. This study highlights the lipid-induced biases on the CEST z-spectrum. The results are promising for body applications where B0 heterogeneities and fat are more substantial.


Assuntos
Imageamento por Ressonância Magnética , Água , Humanos , Imageamento por Ressonância Magnética/métodos , Encéfalo/diagnóstico por imagem , Meios de Contraste , Lipídeos , Algoritmos
9.
Magn Reson Med ; 90(2): 770-783, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-36999747

RESUMO

PURPOSE: Optimization of transmit array performance is crucial in ultra-high-field MRI scanners such as 11.7T because of the increased RF losses and RF nonuniformity. This work presents a new workflow to investigate and minimize RF coil losses, and to choose the optimum coil configuration for imaging. METHODS: An 8-channel transceiver loop-array was simulated to analyze its loss mechanism at 499.415 MHz. A folded-end RF shield was developed to limit radiation loss and improve the B 1 + $$ {B}_1^{+} $$ efficiency. The coil element length, and the shield diameter and length were further optimized using electromagnetic (EM) simulations. The generated EM fields were used to perform RF pulse design (RFPD) simulations under realistic constraints. The chosen coil design was constructed to demonstrate performance equivalence in bench and scanner measurements. RESULTS: The use of conventional RF shields at 11.7T resulted in significantly high radiation losses of 18.4%. Folding the ends of the RF shield combined with optimizing the shield diameter and length increased the absorbed power in biological tissue and reduced the radiation loss to 2.4%. The peak B 1 + $$ {B}_1^{+} $$ of the optimal array was 42% more than the reference array. Phantom measurements validated the numerical simulations with a close match of within 4% of the predicted B 1 + $$ {B}_1^{+} $$ . CONCLUSION: A workflow that combines EM and RFPD simulations to numerically optimize transmit arrays was developed. Results have been validated using phantom measurements. Our findings demonstrate the need for optimizing the RF shield in conjunction with array element design to achieve efficient excitation at 11.7T.


Assuntos
Cabeça , Ondas de Rádio , Imageamento por Ressonância Magnética/métodos , Encéfalo/diagnóstico por imagem , Imagens de Fantasmas , Desenho de Equipamento , Neuroimagem
10.
NMR Biomed ; 36(5): e4877, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36400716

RESUMO

Quantitative three-dimensional (3D) imaging of phosphorus (31 P) metabolites is potentially a promising technique with which to assess the progression of liver disease and monitor therapy response. However, 31 P magnetic resonance spectroscopy has a low sensitivity and commonly used 31 P surface coils do not provide full coverage of the liver. This study aimed to overcome these limitations by using a 31 P whole-body transmit coil in combination with a 16-channel 31 P receive array at 7 T. Using this setup, we determined the repeatability of whole-liver 31 P magnetic resonance spectroscopic imaging (31 P MRSI) in healthy subjects and assessed the effects of principal component analysis (PCA)-based denoising on the repeatability parameters. In addition, spatial variations of 31 P metabolites within the liver were analyzed. 3D 31 P MRSI data of the liver were acquired with a nominal voxel size of 20 mm isotropic in 10 healthy volunteers twice on the same day. Data were reconstructed without denoising, and with PCA-based denoising before or after channel combination. From the test-retest data, repeatability parameters for metabolite level quantification were determined for 12 31 P metabolite signals. On average, 31 P MR spectra from 100 ± 25 voxels in the liver were analyzed. Only voxels with contamination from skeletal muscle or the gall bladder were excluded and no voxels were discarded based on (low) signal-to-noise ratio (SNR). Repeatability for most quantified 31 P metabolite levels in the liver was good to excellent, with an intrasubject variability below 10%. PCA-based denoising increased the SNR ~ 3-fold, but did not improve the repeatability for mean liver 31 P metabolite quantification with the fitting constraints used. Significant spatial heterogeneity of various 31 P metabolite levels within the liver was observed, with marked differences for the phosphomonoester and phosphodiester metabolites between the left and right lobe. In conclusion, using a 31 P whole-body transmit coil in combination with a 16-channel 31 P receive array at 7 T allowed 31 P MRSI acquisitions with full liver coverage and good to excellent repeatability.


Assuntos
Imageamento por Ressonância Magnética , Fósforo , Humanos , Fósforo/metabolismo , Análise de Componente Principal , Imageamento por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética/métodos , Fígado/metabolismo , Razão Sinal-Ruído
11.
J Magn Reson Imaging ; 57(3): 661-669, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36173367

RESUMO

The use of 7 Tesla (T) magnetic resonance imaging (MRI) is expanding across neurosurgical and neurologic specialties. However, few neurosurgical-related implants have been tested for safety at 7 T, limiting its use in patients with cranial fixation, shunt placements, and other implants. Implant safety can be determined via the American Society for Testing Materials International (ASTM) guidelines. To assess the current state of neurosurgical implant safety at 7 T, a systematic search was performed using PubMed, MEDLINE, Web of Knowledge, and citation matching. Studies written in English that included at least one neurosurgical implant and at least one safety outcome were included. Data were extracted for implant studied, implant composition, deflection angle, torque, temperature change, and ASTM guidelines followed. PRISMA reporting guidelines for scoping reviews were followed. Overall, 18 studies consisting of 45 unique implants were included. Implants included cranial fixation devices, aneurysm clips, spinal rods, pedicle screws, ventriculoperitoneal (VP) shunts, deep brain stimulation devices, and electroencephalogram (EEG) caps and electrodes. Cranial fixation devices, deep brain stimulation devices, spinal rods, and pedicle screws are likely 7 T MRI compatible based on outcomes reported. Aneurysm clips and EEG devices had variable safety outcomes. The VP shunts studied lost functionality after 7 T MRI exposure. We identified several implants that are likely compatible with 7 T MRI. Given the growth in 7 T imaging and expansion of the technology, neurosurgical implants should be constructed with the aforementioned considerations. Caution must be taken with all implants, especially aneurysm clips, programmable VP shunts, and EEG recording devices. It is also noteworthy that several implant testing reports did not report following ASTM standards. This scoping review seeks to concisely summarize all neurosurgical-related implants that have been tested for safety in 7 T MRI. EVIDENCE LEVEL: 2 TECHNICAL EFFICACY: Stage 2.


Assuntos
Aneurisma , Próteses e Implantes , Humanos , Imageamento por Ressonância Magnética/efeitos adversos , Imageamento por Ressonância Magnética/métodos
12.
Int J Mol Sci ; 24(7)2023 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-37047596

RESUMO

This study aimed to evaluate an intracerebral hemorrhage (ICH) model using quantitative susceptibility mapping (QSM) and chemical exchange saturation transfer (CEST) with preclinical 7T-magnetic resonance imaging (MRI) and determine the potential of amide proton transfer-CEST (APT-CEST) for use as a biomarker for the early detection of ICH. Six Wistar male rats underwent MRI, and another six underwent histopathological examinations on postoperative days 0, 3, and 7. The ICH model was created by injecting bacterial collagenase into the right hemisphere of the brain. QSM and APT-CEST MRI were performed using horizontal 7T-MRI. Histological studies were performed to observe ICH and detect iron deposition at the ICH site. T2-weighted images (T2WI) revealed signal changes associated with hemoglobin degeneration in red blood cells, indicating acute-phase hemorrhage on day 0, late-subacute-phase hemorrhage on day 3, and chronic-phase hemorrhage on day 7. The susceptibility alterations in each phase were detected using QSM. QSM and Berlin blue staining revealed hemosiderin deposition in the chronic phase. APT-CEST revealed high magnetization transfer ratios in the acute phase. Abundant mobile proteins and peptides were observed in early ICH, which were subsequently diluted. APT-CEST imaging may be a reliable noninvasive biomarker for the early diagnosis of ICH.


Assuntos
Amidas , Prótons , Ratos , Animais , Masculino , Amidas/metabolismo , Ratos Wistar , Imageamento por Ressonância Magnética/métodos , Hemorragia Cerebral/diagnóstico por imagem , Biomarcadores
13.
Neuroimage ; 252: 119043, 2022 05 15.
Artigo em Inglês | MEDLINE | ID: mdl-35235838

RESUMO

Deep brain stimulation (DBS) is an increasingly utilized treatment for multiple neurological disorders. Continued improvements in DBS outcome are, in part, related to increasing ability to directly visualize stimulation targets by MRI. However, it is challenging to image DBS targets with conventional MRI techniques due to limited contrast. Fast Gray Matter Acquisition T1 Inversion Recovery (FGATIR) is a commonly used MRI sequence that improves visualization of several key DBS targets by suppressing white matter (WM) signal to better reveal deep-brain gray matter (GM) structures. Due to increased signal level at high field strength, application of FGATIR on 7T MRI may allow higher spatial resolution and better DBS targeting accuracy. However, successful utilization of FGATIR requires meticulous sequence optimization involving multiple parameters to maximize GM signal while suppressing WM. This is further complicated by the transmit RF field (B1+) inhomogeneity on 7T, which can cause severe contrast degradation. In this work, we introduce a systematic approach to optimize FGATIR and to improve visualization of thalamic DBS targets on 7T. FGATIR optimization is cast into a constrained optimization problem whose objective function and constraints are designed to maximize the GM-WM contrast-to-noise ratio (CNR) while accounting for B1+ inhomogeneity. This approach allows a systematic search for optimal parameters across the multi-dimensional parametric space while limiting the negative effect of B1+ variation. Bloch equation simulations were performed to solve the proposed optimization problem and to compare the sequence derived from this method against the sequence optimized without considering B1+ inhomogeneity. The results showed that this approach can improve GM-WM CNR in the presence of B1+ inhomogeneity, especially in some high relative B1+ areas where several key thalamic DBS targets are located. Additionally, in vivo images were acquired on a clinical 7T MRI to further validate this approach. Severe contrast degradation in the thalamus was observed when B1+ effect was not considered in sequence optimization, while the proposed approach yielded improved image contrast in the thalamus with key DBS targets well-defined. These results demonstrated that the proposed method allowed optimization of FGATIR on 7T to better visualize thalamic DBS targets, which may lead to improved DBS targeting accuracy as well as treatment outcome.


Assuntos
Estimulação Encefálica Profunda , Substância Branca , Encéfalo/diagnóstico por imagem , Córtex Cerebral , Estimulação Encefálica Profunda/métodos , Substância Cinzenta/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética/métodos , Substância Branca/diagnóstico por imagem
14.
Magn Reson Med ; 88(3): 1434-1449, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35666836

RESUMO

PURPOSE: To evaluate specific absorption rate (SAR) and temperature distributions resulting from pediatric exposure to a 7T head coil. METHODS: Exposure from a 297-MHz birdcage head transmit coil (CP mode single-channel transmission) was simulated in several child models (ages 3-14, mass 13.9-50.4 kg) and one adult, using time-domain electromagnetic and thermal solvers. Position variability, age-related changes in dielectric properties, and differences in thermoregulation were also considered. RESULTS: Age-adjusted dielectric properties had little effect in this population. Head average SAR (hdSAR) was the limiting factor for all models centered in the coil. The value of hdSAR (normalized to net power) was found to decrease linearly with increasing mass (R2  = 0.86); no equivalent relationship for peak-spatial 10g averaged SAR (psSAR10g ) was identified. Relatively small (< 10%) variability was observed in hdSAR for position shifts of ±25 mm in each orthogonal direction when normalized to net power; accounting for B1+$$ {\mathrm{B}}_1^{+} $$ efficiency can lead to much larger variability. Position sensitivity of psSAR10g was greater, but in most cases hdSAR remained the limiting quantity. For thermal simulations, if blood temperature is fixed (i.e., asserting good thermoregulation), maximum temperatures are compliant with International Electrotechnical Commission limits during 60-min exposure at the SAR limit. Introducing variable blood temperature leads to core temperature changes proportional to whole-body averaged SAR, exceeding guideline limits for all child models. CONCLUSIONS: Children experienced higher SAR than adults for the 297-MHz head transmit coil examined in this work. Thermal simulations suggest that core temperature changes could occur in smaller subjects, although experimental data are needed for validation.


Assuntos
Calefação , Imageamento por Ressonância Magnética , Adolescente , Adulto , Temperatura Corporal , Criança , Pré-Escolar , Simulação por Computador , Humanos , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas , Ondas de Rádio , Temperatura
15.
NMR Biomed ; 35(5): e4656, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-34962689

RESUMO

In this study, the performance of an integrated body-imaging array for 7 T with 32 radiofrequency (RF) channels under consideration of local specific absorption rate (SAR), tissue temperature, and thermal dose limits was evaluated and the imaging performance was compared with a clinical 3 T body coil. Thirty-two transmit elements were placed in three rings between the bore liner and RF shield of the gradient coil. Slice-selective RF pulse optimizations for B1 shimming and spokes were performed for differently oriented slices in the body under consideration of realistic constraints for power and local SAR. To improve the B1+ homogeneity, safety assessments based on temperature and thermal dose were performed to possibly allow for higher input power for the pulse optimization than permissible with SAR limits. The results showed that using two spokes, the 7 T array outperformed the 3 T birdcage in all the considered regions of interest. However, a significantly higher SAR or lower duty cycle at 7 T is necessary in some cases to achieve similar B1+ homogeneity as at 3 T. The homogeneity in up to 50 cm-long coronal slices can particularly benefit from the high RF shim performance provided by the 32 RF channels. The thermal dose approach increases the allowable input power and the corresponding local SAR, in one example up to 100 W/kg, without limiting the exposure time necessary for an MR examination. In conclusion, the integrated antenna array at 7 T enables a clinical workflow for body imaging and comparable imaging performance to a conventional 3 T clinical body coil.


Assuntos
Imageamento por Ressonância Magnética , Ondas de Rádio , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas , Temperatura
16.
Mult Scler ; 28(11): 1773-1782, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35603749

RESUMO

BACKGROUND: Gait in people with multiple sclerosis (PwMS) is affected even when no changes can be observed on clinical examination. A sensitive measure of gait deterioration is stability; however, its correlation with motor tract damage has not yet been established. OBJECTIVE: To compare stability between PwMS and healthy controls (HCs) and determine associations between stability and diffusion magnetic resonance image (MRI) measures of axonal damage in selected sensorimotor tracts. METHODS: Twenty-five PwMS (Expanded Disability Status Scale (EDSS) < 2.5) and 15 HCs walked on a treadmill. Stability from sacrum (LDESAC), shoulder (LDESHO) and cervical (LDECER) was calculated using the local divergence exponent (LDE). Participants underwent a 7T-MRI brain scan to obtain fibre-specific measures of axonal loss within the corticospinal tract (CST), interhemispheric sensorimotor tract (IHST) and cerebellothalamic tract (CTT). Correlation analyses between LDE and fibre density (FD) within tracts, fibre cross-section (FC) and FD modulated by FC (FDC) were conducted. Between-groups LDE differences were analysed using analysis of variance (ANOVA). RESULTS: Correlations between all stability measures with CSTFD, between CSTFDC with LDESAC and LDECER, and LDECER with IHSTFD and IHSTFDC were significant yet moderate (R < -0.4). Stability was significantly different between groups. CONCLUSIONS: Poorer gait stability is associated with corticospinal tract (CST) axonal loss in PwMS with no-to-low disability and is a sensitive indicator of neurodegeneration.


Assuntos
Esclerose Múltipla , Teste de Esforço/métodos , Marcha , Humanos , Esclerose Múltipla/patologia , Tratos Piramidais/diagnóstico por imagem , Tratos Piramidais/patologia , Caminhada
17.
Muscle Nerve ; 66(2): 206-211, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35621349

RESUMO

INTRODUCTION/AIMS: Magnetic resonance imaging (MRI) of peripheral nerves can provide image-based anatomical information and quantitative measurement. The aim of this pilot study was to investigate the feasibility of high-resolution anatomical and quantitative MRI assessment of sciatic nerve fascicles in patients with Charcot-Marie-Tooth (CMT) 1A using 7T field strength. METHODS: Six patients with CMT1A underwent imaging on a high-gradient 7T MRI scanner using a 28-channel knee coil. Two high-resolution axial images were simultaneously acquired using a quantitative double-echo in steady-state (DESS) sequence. By comparing the two DESS echoes, T2 and apparent diffusion coefficient (ADC) maps were calculated. The cross-sectional areas and mean T2 and ADC were measured in individual fascicles of the tibial and fibular (peroneal) portions of the sciatic nerve at its bifurcation and 10 mm distally. Disease severity was measured using Charcot-Marie-Tooth Examination Score (CMTES) version 2 and compared to imaging findings. RESULTS: We demonstrated the feasibility of 7T MRI of the proximal sciatic nerve in patients with CMT1A. Using the higher field, it was possible to measure individual bundles in the tibial and fibular divisions of the sciatic nerve. There was no apparent correlation between diffusion measures and disease severity in this small cohort. DISCUSSION: This pilot study indicated that high-resolution MRI that allows for combined anatomical and quantitative imaging in one scan is feasible at 7T field strengths and can be used to investigate the microstructure of individual nerve fascicles.


Assuntos
Doença de Charcot-Marie-Tooth , Doença de Charcot-Marie-Tooth/diagnóstico por imagem , Doença de Charcot-Marie-Tooth/patologia , Estudos de Viabilidade , Humanos , Imageamento por Ressonância Magnética/métodos , Projetos Piloto , Nervo Isquiático/diagnóstico por imagem , Nervo Isquiático/patologia
18.
Neuroradiology ; 64(12): 2217-2226, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35754063

RESUMO

PURPOSE: To assess the ability of 7 T MRI to detect hippocampal DWI lesions in the acute phase of TGA compared to 1.5 T/3 T MRI. METHODS: Patients with a clinical diagnosis consistent with TGA and a 1.5/3 T MRI underwent an additional 7 T MRI when the 7 T system was available for clinical use, thus serving as their own controls. RESULTS: Thirteen TGA patients with a median age of 68.5 years (range 46-77 years) were included and imaged at 1.5/3 T (median 17 h after onset of symptoms, range 3-23 h) and 7 T (median 23 h after onset, range 15-46 h). The 7 T MRIs were performed a median of 15 h after the 1.5/3 T MRIs (range 1-28 h). At 1.5/3 T, six patients (46%) were found to have at least one hippocampal DWI-lesions supporting the TGA diagnosis, which increased to 11 patients (85%) when examined at 7 T (p = 0.03). At 1.5/3 T, nine hippocampal DWI lesions were detected, which increased to 19 at 7 T, giving an increased detection rate of 111% (p = 0.002). Both neuroradiologists found the hippocampal DWI lesions at 7 T to have higher conspicuity and be easier to categorize as true findings compared to 1.5/3 T. CONCLUSION: Seven-Tesla MRI showed both a statistically significant increase in the total number of detected hippocampal DWI lesions and the proportion of patients with at least one hippocampal DWI lesion supporting the TGA diagnosis compared to 1.5/3 T. Clinical use of 7 T will increase the number of patients having their TGA diagnosis supported by MRI, which can be especially useful in patients with negative 1.5/3 T MRI and low clinical certainty.


Assuntos
Amnésia Global Transitória , Humanos , Pessoa de Meia-Idade , Idoso , Amnésia Global Transitória/diagnóstico por imagem , Amnésia Global Transitória/patologia , Imagem de Difusão por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética , Hipocampo/diagnóstico por imagem , Hipocampo/patologia , Difusão
19.
Sensors (Basel) ; 22(11)2022 May 26.
Artigo em Inglês | MEDLINE | ID: mdl-35684654

RESUMO

The core body temperature tends to decrease under general anesthesia. Consequently, monitoring the core body temperature during procedures involving general anesthesia is essential to ensure patient safety. In veterinary medicine, rectal temperature is used as an indicator of the core body temperature, owing to the accuracy and convenience of this approach. Some previous studies involving craniotomy reported differences between the brain and core temperatures under general anesthesia. However, noninvasive imaging techniques are required to ascertain this because invasive brain temperature measurements can cause unintended temperature changes by inserting the temperature sensors into the brain or by performing the surgical operations. In this study, we employed in vivo magnetic resonance thermometry to observe the brain temperatures of patients under general anesthesia using the proton resonance frequency shift method. The rectal temperature was also recorded using a fiber optic thermometer during the MR thermometry to compare with the brain temperature changes. When the rectal temperature decreased by 1.4 ± 0.5 °C (mean ± standard deviation), the brain temperature (white matter) decreased by 4.8 ± 0.5 °C. Furthermore, a difference in the temperature reduction of the different types of brain tissue was observed; the reduction in the temperature of white matter exceeded that of gray matter mainly due to the distribution of blood vessels in the gray matter. We also analyzed and interpreted the core temperature changes with the body conditioning scores of subjects to see how the body weight affected the temperature changes.


Assuntos
Temperatura Corporal , Termometria , Anestesia Geral , Animais , Encéfalo/diagnóstico por imagem , Cães , Humanos , Espectroscopia de Ressonância Magnética , Termometria/métodos
20.
Sensors (Basel) ; 22(4)2022 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-35214409

RESUMO

Magnetic resonance imaging (MRI) systems must undergo quantitative evaluation through daily and periodic performance assessments. In general, the reference or standard radiofrequency (RF) coils for these performance assessments of 1.5 to 7.0 T MRI systems have been low-pass-type birdcage (LP-BC) RF coils. However, LP-BC RF coils are inappropriate for use as reference RF coils because of their relatively lower magnetic field (B1-field) sensitivity than other types of BC RF coils, especially in ultrahigh-field (UHF) MRI systems above 3.0 T. Herein, we propose a hybrid-type BC (Hybrid-BC) RF coil as a reference RF coil with improved B1-field sensitivity in UHF MRI system and applied it to an 11.7 T MRI system. An electromagnetic field (EM-field) analysis on the Hybrid-BC RF coil was performed to provide the proper dimensions for its use as a reference RF coil. Commercial finite difference time-domain program was used in EM-field simulation, and home-made analysis programs were used in analysis. The optimal specifications of the proposed Hybrid-BC RF coils for them to qualify as reference RF coils are proposed based on their B1+-field sensitivity under unnormalized conditions, as well as by considering their B1+-field uniformity and RF safety under normalized conditions.


Assuntos
Campos Eletromagnéticos , Ondas de Rádio , Simulação por Computador , Desenho de Equipamento , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa