RESUMO
The soluble fraction of atmospheric transition metals is particularly associated with health effects such as reactive oxygen species compared to total metals. However, direct measurements of the soluble fraction are restricted to sampling and detection units in sequence burdened with a compromise between time resolution and system bulkiness. Here, we propose the concept of aerosol-into-liquid capture and detection, which allowed one-step particle capture and detection via the Janus-membrane electrode at the gas-liquid interface, enabling active enrichment and enhanced mass transport of metal ions. The integrated aerodynamic/electrochemical system was capable of capturing airborne particles with a cutoff size down to 50 nm and detecting Pb(II) with a limit of detection of 95.7 ng. The proposed concept can pave the way for cost-effective and miniaturized systems, for the capture and detection of airborne soluble metals in air quality monitoring, especially for abrupt air pollution events with high airborne metal concentrations (e.g., wildfires and fireworks).
RESUMO
Wildfires are increasing in frequency, intensity, and extent globally due to climate change and they can alter forest composition, structure, and function. The destruction and subsequent regrowth of young vegetation can modify the ecosystem evapotranspiration and downstream water availability. However, the response of forest recovery on hydrology is not well known with even the sign of evapotranspiration and water yield changes following forest fires being uncertain across the globe. Here, we quantify the effects of forest regrowth after catastrophic wildfires on evapotranspiration and runoff in the world's tallest angiosperm forest (Eucalyptus regnans) in Australia. We combine eddy covariance measurements including pre- and post-fire periods, mechanistic ecohydrological modeling and then extend the analysis spatially to multiple fires in eucalypt-dominated forests in south-eastern Australia by utilizing remote sensing. We find a fast recovery of evapotranspiration which reaches and exceeds pre-fire values within 2 years after the bushfire, a result confirmed by eddy covariance data, remote sensing, and modeling. Such a fast evapotranspiration recovery is likely generalizable to tall eucalypt forests in south-eastern Australia as shown by remote sensing. Once climate variability is discounted, ecohydrological modeling shows evapotranspiration rates from the recovering forest which reach peak values of +20% evapotranspiration 3 years post-fire. As a result, modeled runoff decreases substantially. Contrary to previous research, we find that the increase in modeled evapotranspiration is largely caused by the aerodynamic effects of a much shorter forest height leading to higher surface temperature, higher humidity gradients and therefore increased transpiration. However, increases in evapotranspiration as well as decreases in runoff caused by the young forest are constrained by energy and water limitations. Our result of an increase in evapotranspiration due to aerodynamic warming in a shorter forest after wildfires could occur in many parts of the world experiencing forest disturbances.
Assuntos
Incêndios , Incêndios Florestais , Ecossistema , Água , FlorestasRESUMO
BACKGROUND: SPEAK OUT! has been shown to enhance various aspects of voice such as intensity, prosody, voice quality and perception of voice. However, their impacts on expiration and communication effectiveness have not yet been evaluated. This study aimed to evaluate the effectiveness of the Hybrid SPEAK OUT! method on aerodynamic measurements and patient-reported outcome measures (PROMs) in individuals with Parkinson's disease (PD). METHODS: This study included 157 participants with PD who underwent an intensive 8-week multidisciplinary treatment program. The Hybrid SPEAK OUT! method consisted of three sessions per week, including two group sessions and one individual treatment session. Voice-related aerodynamic measures included maximum phonation time (MPT), vocal cord function using the S/Z ratio, and expiratory flow measures including peak expiratory flow (PEF) and peak cough flow (PCF). Two PROMs were included: the Hebrew version of the voice handicap index-10 and communication effectiveness questionnaire. RESULTS: The results of 111 participants were analysed. MPT duration increased, PEF and PCF increased, and better scores were found in PROMs. CONCLUSION: These findings would appear to support the effectiveness of the Hybrid SPEAK OUT! methods improving function, activity and participation in individuals with PD. However, further research is needed. WHAT THIS PAPER ADDS: What is already known on the subject Prior research has demonstrated the effectiveness of behavioral therapies, including the SPEAK OUT! program, in managing speech symptoms in individuals with Parkinson's disease (PD). These therapies have shown improvements in voice intensity, fundamental frequency, voice quality, and voice perception. However, the impact on aerodynamic measures, expiratory flow, and patient-reported outcome measures has not been extensively studied. What this paper adds to existing knowledge This study adds to the existing knowledge by demonstrating that a Hybrid SPEAK OUT! approach, can lead to improvements in aerodynamic measures, including maximum phonation time (MPT), expiratory and cough peak flow. In terms of motor learning, we found that two non-speech exhalation-related tasks that were not directly trained improved following the intensive speech training protocol. Furthermore, it shows positive changes in patient-reported outcome measures, with reduced voice-related disability and improved communication efficiency. What are the potential or actual clinical implications of this work? The findings of this study have important clinical implications for the management of speech symptoms in individuals with PD. The Hybrid SPEAK OUT! program, which combines group and individual sessions, can effectively improve voice, aerodynamic measurements and patient-reported outcome measures (PROMs), ultimately enhancing the overall quality of life for patients. These findings support the effectiveness of the Hybrid SPEAK OUT! methods for improving function, activity, and participation in individuals with PD.
RESUMO
The modulation of the leaf energy budget components to maintain optimal leaf temperature are fundamental aspects of plant functioning and survival. Better understanding these aspects becomes increasingly important under a drying and warming climate when cooling through evapotranspiration (E) is suppressed. Combining novel measurements and theoretical estimates, we obtained unusually comprehensive twig-scale leaf energy budgets under extreme field conditions in droughted (suppressed E) and non-droughted (enhanced E) plots of a semi-arid pine forest. Under the same high mid-summer radiative load, leaf cooling shifted from relying on nearly equal contributions of sensible (H) and latent (LE) energy fluxes in non-droughted trees to relying almost exclusively on H in droughted ones, with no change in leaf temperature. Relying on our detailed leaf energy budget, we could demonstrate that this is due to a 2× reduction in leaf aerodynamic resistance. This capability for LE-to-H shift in leaves of mature Aleppo pine trees under droughted field conditions without increasing leaf temperature is likely a critical factor in the resilience and relatively high productivity of this important Mediterranean tree species under drying conditions.
Assuntos
Clima , Secas , Estações do Ano , Temperatura , Árvores , Folhas de PlantaRESUMO
Concentrated collection of aerosol particles on a substrate is essential for their chemical analysis using various microscopy and laser spectroscopic techniques. An impaction-based aerosol concentration system was developed for focused collection of particles using a multi-stage nozzle that consists of a succession of multiple smooth converging stages. Converging sections of the nozzle were designed to focus and concentrate a particle diameter range of 900-2500 nm into a relatively narrower particle beam to obtain particulate deposits with spot diameters of 0.5-1.56 mm. A slightly diverging section before the last contractions was included to allow for better focusing of particles at the lower end of the collectable diameter range. The characterization of this multi-stage nozzle and the impaction-based aerosol concentration system was accomplished both numerically and experimentally. The numerical and experimental trends in collection efficiency and spot diameters agreed well qualitatively; however, the quantitative agreement between numerical and experimental results for wall losses was poor, particularly for larger particle diameters. The resulting concentrated particulate deposit, a spot sample, was analysed using Raman spectroscopy to probe the effect of spot size on analytical sensitivity of measurement. The method's sensitivity was compared against other conventional techniques, such as filtration and aerosol focused impaction, implementing condensational growth. Impaction encompassing the multi-stage focusing nozzle is the only method that can ensure high sensitivity at Reynolds numbers greater than 2000, that can be supported by small pumps which renders such method suitable for portable instrumentation.
RESUMO
Rationale: Ecological studies have shown air pollution associations with coronavirus disease (COVID-19) outcomes. However, few cohort studies have been conducted. Objectives: To conduct a cohort study investigating the association between air pollution and COVID-19 severity using individual-level data from the electronic medical record. Methods: This cohort included all individuals who received diagnoses of COVID-19 from Kaiser Permanente Southern California between March 1 and August 31, 2020. One-year and 1-month averaged ambient air pollutant (particulate matter ⩽2.5 µm in aerodynamic diameter [PM2.5], NO2, and O3) exposures before COVID-19 diagnosis were estimated on the basis of residential address history. Outcomes included COVID-19-related hospitalizations, intensive respiratory support (IRS), and ICU admissions within 30 days and mortality within 60 days after COVID-19 diagnosis. Covariates included socioeconomic characteristics and comorbidities. Measurements and Main Results: Among 74,915 individuals (mean age, 42.5 years; 54% women; 66% Hispanic), rates of hospitalization, IRS, ICU admission, and mortality were 6.3%, 2.4%, 1.5%, and 1.5%, respectively. Using multipollutant models adjusted for covariates, 1-year PM2.5 and 1-month NO2 average exposures were associated with COVID-19 severity. The odds ratios associated with a 1-SD increase in 1-year PM2.5 (SD, 1.5 µg/m3) were 1.24 (95% confidence interval [CI], 1.16-1.32) for COVID-19-related hospitalization, 1.33 (95% CI, 1.20-1.47) for IRS, and 1.32 (95% CI, 1.16-1.51) for ICU admission; the corresponding odds ratios associated with 1-month NO2 (SD, 3.3 ppb) were 1.12 (95% CI, 1.06-1.17) for hospitalization, 1.18 (95% CI, 1.10-1.27) for IRS, and 1.21 (95% CI, 1.11-1.33) for ICU admission. The hazard ratios for mortality were 1.14 (95% CI, 1.02-1.27) for 1-year PM2.5 and 1.07 (95% CI, 0.98-1.16) for 1-month NO2. No significant interactions with age, sex or ethnicity were observed. Conclusions: Ambient PM2.5 and NO2 exposures may affect COVID-19 severity and mortality.
Assuntos
Poluentes Atmosféricos , Poluição do Ar , COVID-19 , Poluentes Ambientais , Adulto , Poluentes Atmosféricos/efeitos adversos , Poluentes Atmosféricos/análise , Poluição do Ar/efeitos adversos , Poluição do Ar/análise , Teste para COVID-19 , California/epidemiologia , Estudos de Coortes , Exposição Ambiental/efeitos adversos , Exposição Ambiental/análise , Feminino , Humanos , Masculino , Dióxido de Nitrogênio , Material Particulado/efeitos adversos , Material Particulado/análiseRESUMO
This paper presents experimental investigations on aerodynamic performance of a ducted coaxial-rotor system to evaluate its potential application as a small unmanned aerial vehicle (SUAV). Aimed at determining the influence of design parameters (rotor spacing, tip clearance and rotor position within the duct) on hover performance, a variety of systematic measurements for several correlative configurations (single/coaxial rotor with or without a duct) in terms of thrust and torque, as well as power, were conducted in an attempt to identify a better aerodynamic configuration. The experimental results for the coaxial-rotor system indicated that varying rotor spacing affected the thrust-sharing proportion between the two rotors, but this had no significant effect on the propulsive efficiency. The optimal H/R ratio was identified as being 0.40, due to a larger thrust and stronger stability in the case of identical rotation speeds. As for the ducted single-rotor configuration, the tip clearance played a dominant role in improving its thrust performance, especially for smaller gaps (뫲0.015R), while the rotor position made subordinate contributions. The maximum performance was obtained with the rotor located at the P5 position (0.31Cd from the duct lip), which resulted in an enhancement of approximately 20% in power loading over the isolated single rotor. When the coaxial rotors were surrounded within the duct, the system thrust for a given power degraded with the increasing rotor spacing, which was mainly attributed to the upper rotor suffering from heavier leakage losses. And hence, the ducted coaxial-rotor system with S1 spacing had the best propulsion efficiency and hover performance with a figure of merit of 0.61.
RESUMO
Particle mass and particulate size are two important parameters used to characterize the aerosol. Currently, there are a few methods for measuring particle mass concentration and particle size. However, the existing methods have their own shortcomings. In this article, we describe a novel laser scattering instrument that measures mass concentration and particle size in real time over a wide concentration range. This instrument combines laser scattering and time-of-flight aerodynamics in one optical device. There are two innovations in this paper: (1) Two APD detectors are used to receive scattered light. One receives forward-scattered light and the other receives side-scattered light. The advantage is that the sensitivity of the detector is increased greatly, and the ratio of forward and side scattering is used to further obtain the size and shape information of the particles. (2) In order to measure the high concentrations of aerosol, a high-speed ADC and FPGA is combined to achieve an anti-overlap algorithm objective. It has been verified by experiments that the anti-overlapping algorithm can effectively improve the applicability of the aerodynamic particle size spectrometer under high concentration conditions.
RESUMO
This article proposes a new type of three-component optic fiber balance based on Fabry-Perot displacement measurement technology based on the structure of the pulse wind tunnel balance. This paper systematically introduces the force measurement principle and design process of a three-component optic fiber balance and conducts relevant simulation analysis and experimental verification. The simulation results show that the Fabry-Perot sensor can achieve significant sensitivity to cavity length changes, and when used in existing balance structures, sensitivity gains can be achieved by changing the probe height without the need to modify the original structure of the balance. Finally, the feasibility of the design method was verified through calibration experiments: the optic fiber balance has high sensitivity and good linearity compared to simulation sensitivity, the error is less than 6%, and the calibration accuracy of each component is better than 0.13%, which is better than the existing traditional strain balance (0.37%). The pulse wind tunnel force measurement test has a short test time and a large model mass, and the balance needs to have a large stiffness to meet the short-term force measurement requirements. The introduction of more sensitive optic fiber balance force measurement technology is expected to solve the contradiction between the stiffness and sensitivity of force measurement systems.
RESUMO
We established an experimental apparatus by combining polarized light scattering and angle-resolved light scattering measurement technology to rapidly identify the shape of an individual aerosol particle. The experimental data of scattered light of Oleic acid, rod-shaped Silicon dioxide, and other particles with typical shape characteristics were analyzed statistically. To better study the relationship between the shape of particles and the properties of scattered light, the partial least squares discriminant analysis (PLS-DA) method was used to analyze the scattered light of aerosol samples based on the size screening of particles, and the shape recognition and classification method of the individual aerosol particle was established based on the analysis of the spectral data after nonlinear processing and grouping by particle size with the area under the receiver operating characteristic curve (AUC) as reference. The experimental results show that the proposed classification method has a good discrimination ability for spherical, rod-shaped, and other non-spherical particles, which can provide more information for atmospheric aerosol measurement, and has application value for traceability and exposure hazard assessment of aerosol particles.
Assuntos
Tamanho da Partícula , Nefelometria e Turbidimetria , AerossóisRESUMO
Film cooling is a major cooling technique used in modern gas turbines and air engines. The geometry of film-cooling holes is the fundamental aspect affecting the cooling performance. In this paper, a new cooling configuration called the double-expansion film-cooling hole has been put forward, which yields better performance than the widely used shaped holes and is easy to manufacture. The double-expansion holes at inclination angles of α=30∘, 45∘, and 60∘ are optimized using the genetic algorithm and the Kriging surrogate model, which is trained by CFD data randomly sampled using the Latin hypercube method. The numerically optimized double-expansion holes at different inclination angles were experimentally evaluated and compared with the optimized single-expansion laid-back fan-shaped holes, and the optimized double-expansion hole at α=30∘ was manually modified based on experiment results. Compared with the optimal single-expansion holes, the area-averaged cooling effectiveness of the double-expansion holes was increased by 34.5% at α=30∘, by 27.8% at α=45∘, and basically the same at α=60∘, showing the benefit of the double-expansion concept. The loss mechanism of film cooling was also analyzed in the perspective of the entropy generation rate, showing the optimal double-expansion holes have 21% less loss compared to a baseline narrow single-expansion hole. It was also found that CFD sometimes predicts a different trend from the experiment in optimization, and the experimental validation is necessary.
RESUMO
IgA nephropathy (IgAN) is characterized by deposition of galactose-deficient IgA1 (Gd-IgA1) in glomerular mesangium associated with mucosal immune disorders. Since environmental pollution has been associated with the progression of chronic kidney disease in the general population, we specifically investigated the influence of exposure to fine particulate matter less than 2.5 µm in diameter (PM2.5) on IgAN progression. Patients with biopsy-proven primary IgAN were recruited from seven Chinese kidney centers. PM2.5 exposure from 1998 to 2016 was derived from satellite aerosol optical depth data and a total of 1,979 patients with IgAN, including 994 males were enrolled. The PM2.5 exposure levels for patients from different provinces varied but, in general, the PM2.5 exposure levels among patients from the north were higher than those among patients from the south. The severity of PM2.5 exposure in different regions was correlated with regional kidney failure burden. In addition, each 10 µg/m3 increase in annual average concentration of PM2.5 exposure before study entry (Hazard Ratio, 1.14; 95% confidence interval, 1.06-1.22) or time-varying PM2.5 exposure after study entry (1.10; 1.01-1.18) were associated with increased kidney failure risk after adjustment for age, gender, estimated glomerular filtration rate, urine protein, uric acid, hemoglobin, mean arterial pressure, Oxford classification, glucocorticoid and renin-angiotensin system blocker therapy. The associations were robust when the time period, risk factors of cardiovascular diseases or city size were further adjusted on the basis of the above model. Thus, our results suggest that PM2.5 is an independent risk factor for kidney failure in patients with IgAN, but these findings will require validation in more diverse populations and other geographic regions.
Assuntos
Poluição do Ar , Glomerulonefrite por IGA , Insuficiência Renal , Masculino , Humanos , Glomerulonefrite por IGA/epidemiologia , Material Particulado/efeitos adversos , Imunoglobulina A , Poluição do Ar/efeitos adversosRESUMO
Biofilms are communities of bacterial cells encased in a self-produced polymeric matrix and exhibit high tolerance towards environmental stress. Despite the plethora of research on biofilms, most biofilm models are produced using mono-interface culture in static flow conditions, and knowledge of the effects of interfaces and mechanical forces on biofilm development remains fragmentary. This study elucidated the effects of air-liquid (ALI) or liquid-liquid (LLI) interfaces and mechanical shear forces induced by airflow and hydrodynamic flow on biofilm growing using a custom-designed dual-channel microfluidic platform. Results from this study showed that comparing biofilms developed under continuous nutrient supply and shear stresses free condition to those developed with limited nutrient supply, ALI biofilms were four times thicker, 60% less permeable, and 100 times more resistant to antibiotics, while LLI biofilms were two times thicker, 20% less permeable, and 100 times more resistant to antibiotics. Subjecting the biofilms to mechanical shear stresses affected the biofilm structure across the biofilm thickness significantly, resulting in generally thinner and denser biofilm compared to their controlled biofilm cultured in the absence of shear stresses, and the ALI and LLI biofilm's morphology was vastly different. Biofilms developed under hydrodynamic shear stress also showed increased antibiotic resistance. These findings highlight the importance of investigating biofilm growth and its mechanisms in realistic environmental conditions and demonstrate a feasible approach to undertake this study using a novel platform.
Assuntos
Hidrodinâmica , Pseudomonas aeruginosa , Antibacterianos/farmacologia , Biofilmes , Estresse MecânicoRESUMO
The fast spreading of the SARS-CoV-2 virus led to a significant increase in the demand for personal protective equipment (PPE). Healthcare professionals, mainly dentists, work near the patients, increasing their risk of infection. This paper investigates the effectiveness of an air-curtain sealing effect in a newly designed visor developed to reduce the risk of contracting a respiratory infection. This PPE was developed by computational fluid dynamics (CFD) modeling. CFD results show that the aerodynamic sealing in this PPE device effectively protects the user's face by 43% from a contaminated environment. The experiments considered two different tests: one using a tracer gas (CO2 ) to simulate a gaseous contaminant inside and outside the PPE face shield and a second test using smoke to simulate aerosol transport and evaluate the PPE efficiency. The particle concentration within the aerodynamically sealed PPE was evaluated and compared with the protection efficiency of other PPE. Results show similar protection levels for particles in the 1-5 µm range between the prototype and a KN95 respirator. The combined use of this novel PPE with aerodynamic sealing and a physical mask (KN95 or surgical) produced protection efficiency values within the range of 57%-70% for particles greater than 0.5 µm. This study reveals the potential of using an air curtain combined with a face shield to reduce the risks from contaminated environments.
Assuntos
Poluição do Ar em Ambientes Fechados , COVID-19 , COVID-19/prevenção & controle , Dióxido de Carbono , Humanos , Aerossóis e Gotículas Respiratórios , SARS-CoV-2 , FumaçaRESUMO
In this work, consideration is given to an aerodynamic concept to boost the filtration in face masks of airborne hygroscopic particles such as those caused by an infected person when coughs or sneezes. Nowadays, increasing the filtration efficiency of face masks implies either increasing the number of crisscrossing fiber layers or decreasing the equivalent hydraulic diameter of the pore, however, both measures are in clear detriment of its breathability. Here, a novel strategy is proposed in which the filtration of an airborne particle is boosted by increasing its diameter. We called properly this concept as the aerodynamic barrier layer. In this concept, a traditional crisscrossing fiber layer is replaced by a parallel rearranged of the fibers in the direction of the flow. This rearrangement will promote central lift forces which will push the particles toward the center of the channel where after clustering they will coalesce resulting in a bigger particle that can be now easily captured by a conventional fiber crisscrossing layer. Utilizing a simplified geometrical model, an expression for the required length of the aerodynamic barrier layer was derived. It is shown that an aerodynamic barrier layer with a length of only a few millimeters can aerodynamically focus water droplets around 1 µm-diameter and the penetration of airborne particles can be reduced up to 55%.
Assuntos
Filtração/instrumentação , Máscaras , Material Particulado/isolamento & purificação , Desenho de Equipamento , Tamanho da PartículaRESUMO
Quadrotor unmanned aerial vehicles (UAVs) are widely used as flexible and mobile access points and information carriers for the future Internet of Things (IoT). This work studies a quadrotor UAV-assisted IoT network, where the UAV helps to collect sensing data from a group of IoT users. Our goal is to optimize the UAV's overall energy consumption required to complete the sensing task. Firstly, we propose a more accurate and mathematically tractable model to characterize the UAV's real-time energy consumption, which accounts for the UAV's dynamics, brushless direct current (BLDC) motor dynamics and aerodynamics. Then, we can show that the UAV's circular flight based on the proposed energy-consumption model consumes less energy than that of hover flight. Therefore, a fly-circle-communicate (FCC) trajectory design algorithm, adopting Dubins curves for circular flight, is proposed and derived to save energy and increase flight duration. Employing the FCC strategy, the UAV moves to each IoT user and implements a circular flight in the sequence solved by the travelling-salesman-problem (TSP) algorithm. Finally, we evaluate the efficiency of the proposed algorithm in a mobile sensing network by comparing the proposed algorithm with the conventional hover-communicate (HC) algorithm in terms of energy consumption. Numerical results show that the FCC algorithm reduces energy consumption by 1-10% compared to the HC algorithm, and also improves the UAV's flight duration and the sensing network's service range.
RESUMO
High porous particles with specific aerodynamic properties were processed by the spray freeze-drying (SFD) method. Comprehensive knowledge about all aspects of the SFD method is required for particle engineering of various pharmaceutical products with good flow properties. In this review, different types of the SFD method, the most frequently employed excipients, properties of particles prepared by this method, and most recent approaches concerning SFD are summarized. Generally, this technique can prepare spherical-shaped particles with a highly porous interior structure, responsible for the very low density of powders. Increasing the solubility of spray freeze-dried formulations achieves the desired efficacy. Also, due to the high efficiency of SFD, by determining the different features of this method and optimizing the process by model-based studies, desirable results for various inhaled products can be achieved and significant progress can be made in the field of pulmonary drug delivery.
Assuntos
Química Farmacêutica , Administração por Inalação , Química Farmacêutica/métodos , Liofilização/métodos , Tamanho da Partícula , Pós/químicaRESUMO
Strong viscous interaction and multiple flow regimes exist when vehicles fly at high altitude and high Mach number conditions. The Navier-Stokes(NS) solver is no longer applicable in the above situation. Instead, the direct simulation Monte Carlo (DSMC) method or Boltzmann model equation solvers are usually needed. However, they are computationally more expensive than the NS solver. Therefore, it is of great engineering value to establish the aerodynamic prediction model of vehicles at high altitude and high Mach number conditions. In this paper, the hypersonic aerodynamic characteristics of an X38-like vehicle in typical conditions from 70 km to 110 km are simulated using the unified gas kinetic scheme (UGKS), which is applicable for all flow regimes. The contributions of pressure and viscous stress on the force coefficients are analyzed. The viscous interaction parameters, Mach number, and angle of attack are used as independent variables, and the difference between the force coefficients calculated by UGKS and the Euler solver is used as a dependent variable to establish a nonlinear viscous interaction model between them in the range of 70-110 km. The evaluation of the model is completed using the correlation coefficient and the relative orthogonal distance. The conventional viscous interaction effect and rarefied effect are both taken into account in the model. The model can be used to quickly obtain the hypersonic aerodynamic characteristics of X38-like vehicle in a wide range, which is meaningful for engineering design.
RESUMO
To investigate nitrous acid (HONO) levels and potential HONO sources above crop rotation fields. The HONO fluxes were measured by the aerodynamic gradient (AG) method from 14 December 2019 to 2 January 2020 over an agricultural field in the Huaihe River Basin. The ambient HONO levels were measured at two different heights (0.15 and 1.5 m), showing a typical diurnal cycle with low daytime levels and high nighttime levels. The upward HONO fluxes were mostly observed during the day, whereas deposition dominated at night. The diurnal variation of HONO flux followed solar radiation, with a noontime maximum of 0.2 nmol/(m2âsec). The average upward HONO flux of 0.06 ± 0.17 nmol/(m2âsec) indicated that the agricultural field was a net source for atmospheric HONO. The higher HONO/NO2 ratio and NO2-to-HONO conversion rate close to the surface suggested that nocturnal HONO was formed and released near the ground. The unknown HONO source was derived from the daytime HONO budget analysis, with an average strength of 0.31 ppbV/hr at noontime. The surface HONO flux, which was highly correlated with the photolysis frequency J(NO2) (R2 = 0.925) and the product of J(NO2) × NO2 (R2 = 0.840), accounted for â¼23% of unknown daytime HONO source. The significant correlation between HONO fluxes and J(NO2) suggests a light-driven HONO formation mechanism responsible for the surface HONO flux during daytime.
Assuntos
Dióxido de Nitrogênio , Rios , China , Dióxido de Nitrogênio/análise , Ácido Nitroso/análise , FotóliseRESUMO
Aerosols are readily transported on airstreams through building sanitary plumbing and sewer systems, and those containing microbial pathogens (known as bioaerosols) are recognized as contributors to infection spread within buildings. When a defect occurs in the sanitary plumbing system that affects the system integrity, a cross-transmission route is created that can enable the emission of bioaerosols from the system into the building. These emission occurrences are characterized as short-burst events (typically <1 min in duration) which make them difficult to detect and predict. The characterization of these emission events is the focus of this research. Two methods were used to characterize bioaerosol emission events in a full-scale test rig: (a) an Aerodynamic Particle Sizer (APS) for particle size distribution and concentrations; and (b) a slit-to-agar sampler to enumerate the ingress of a viable tracer microorganism (Pseudomonas putida). The APS data confirmed that most particles (>99.5%) were <5 µm and were therefore considered aerosols. Particles generated within the sanitary plumbing system as a result of a toilet flush leads to emissions into the building during system defect conditions with an equivalence of someone talking loudly for over 6 and a half minutes. There were no particles detected of a size >11 µm anywhere in the system. Particle count was influenced by toilet flush volume, but it was not possible to determine if there was any direct influence from airflow rate since both particle and biological data showed no correlation with upward airflow rates and velocities. Typical emissions resulting from a 6 L toilet flush were in the range of 280-400 particles per second at a concentration of typically 9-12 number per cm3 and a total particle count in the region of 3000 to 4000 particles, whereas the peak emissions from a 1.2 L toilet flush were 60-80 particles per second at a concentration of 2.4-3 number per cm3 and a total particle count in the region of 886 to 1045 particles. The reduction in particles is in direct proportion to the reduction in toilet flush volume. The slit-to-agar sampler was able to provide viable time course CFU data and confirmed the origin of the particles to be the tracer microorganism flushed into the system. The time course data also have characteristics consistent with the unsteady nature of a toilet flush.