Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Eur J Pediatr ; 182(1): 343-352, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36352243

RESUMO

Unnecessary radiation exposure (URE) during radiographic examination is an issue among infants in neonatal intensive care units (NICUs). The causes of URE have not been fully explored. This study investigated the incidence and identified the causes of URE in infants during diagnostic radiography in a NICU. This was a retrospective cohort study. We retrieved and analysed requests and radiographs taken at a tertiary NICU between September and November 2018. URE was defined as the rate of discordance between requests and images taken (DisBRI) and unnecessary radiation exposure in irrelevant regions (UREIR) during radiography. We compared the rates of URE between very low-birth-weight (VLBW, birth weight < 1500 g) infants and non-VLBW infants. A total of 306 radiographs from 88 infants were taken. The means ± standard deviations (SDs) of gestational age and birth weight were 35.7 ± 3.6 weeks and 2471 ± 816 g, respectively. Each infant underwent an average of 3.5 radiographs. The DisBRI rate was 1.3% and was mostly related to poor adherence to requests. The UREIR rates in thoraco-abdominal babygrams were 89.6% for the head, 14.8% for the elbows and 18.4% for the knee and were mainly related to improper positioning of and collimation in infants while performing radiography. The UREIR rates for the head, knee and ankle were higher in VLBW infants than in non-VLBW infants (94.6% vs. 85.6%, 27.0% vs. 11.5% and 5.4% vs. 0.7%, respectively, p < 0.05). CONCLUSIONS: URE during diagnostic radiography is common in sick infants and is mainly related to improper positioning and collimation during examinations. Adherence to protocols when performing radiographic examination or using ultrasonography may be a solution to reduce URE in infants in NICUs. WHAT IS KNOWN: • The risk of unnecessary radiation exposure (URE) during radiography has been a common and important issue in sick infants in neonatal intensive care units (NICUs). • The new point-of-care ultrasound (POCUS) technique decreases the need for chest films and prevents radiation exposure in neonates. WHAT IS NEW: • In the NICU, URE is still a common issue in critically ill infants during radiographic examinations. The causes of URE during diagnostic radiography are mainly due to improper positioning and collimation during examinations. • The incidence of URE in irrelevant regions is higher in very low-birth-weight (VLBW) infants than in non-VLBW infants.


Assuntos
Unidades de Terapia Intensiva Neonatal , Exposição à Radiação , Recém-Nascido , Lactente , Humanos , Peso ao Nascer , Estudos Retrospectivos , Recém-Nascido de muito Baixo Peso , Radiografia , Exposição à Radiação/efeitos adversos
2.
J Matern Fetal Neonatal Med ; 29(6): 991-7, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25781498

RESUMO

OBJECTIVE: Radiography after fetal or perinatal death has become a routine part of post-mortem diagnostics. However, only a selected subset of these babygrams or fetal post-mortem skeletal surveys (FPSSs) provides useful information. We investigated the indication for a FPSS. METHODS: Inclusion consisted of the routinely made FPSS (2002-2012) in our university hospital in cases of fetal or perinatal death up to 7 days after birth. We categorized the diagnostic value of the FPSS as no, minor, major or pathognomonic. Regression analysis was used to determine the selection criteria for a useful FPSS. RESULTS: Three hundred and thirty-seven FPSS were included. Three hundred and five (91%) FPSS showed no or minor skeletal malformations. Fourteen (4.2%) FPSS had major skeletal malformations. In 18 (5.3%) cases the diagnosis was based on the pathognomonic skeletal malformations on the FPSS. Two cases were false positive after major birth trauma. The presence of multiple skeletal malformations on prenatal ultrasound or at post-mortem external inspection was highly indicative of a diagnostic FPSS (p < 0.001). CONCLUSION: The majority of the babygrams/FPSS has no contribution to the diagnostic process. Multiple skeletal malformations on prenatal ultrasound or post-mortem external inspection are indicative for a diagnostic FPSS, and this should be the main selection criterion.


Assuntos
Autopsia/estatística & dados numéricos , Feto/diagnóstico por imagem , Esqueleto/diagnóstico por imagem , Feminino , Humanos , Recém-Nascido , Masculino , Radiografia , Estudos Retrospectivos
3.
J Indian Assoc Pediatr Surg ; 13(2): 77-8, 2008 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20011474

RESUMO

This report is to present and discuss an extremely rare association of situs inversus with duodenal atresia in an 11-day-old male neonate born full term and weighing 1.9 kg. The baby presented with recurrent bilious vomiting. Babygram revealed situs inversus and duodenal obstruction. Echocardiography showed dextrocardia with a small ASD. Exploration confirmed a duodenal diaphragm with a central perforation between the third and fourth part of the duodenum and situs inversus. The literature search revealed 20 cases reported so far.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa